Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.8 CrAccepted-AOC | ₹8.8 Cr | L1 | Accepted-AOC Being a lower bidder |
| 2 | L2₹10.0 Cr+₹1.2 Cr (13.8%)Rejected-Finance | ₹10.0 Cr+₹1.2 Cr (13.8%) | L2 | Rejected-Finance Higher than lowest tender |
| 3 | L3₹10.2 Cr+₹1.4 Cr (15.6%)Rejected-Finance 34 KAISER GANJ MANDI DIST MEERUT UP 250002 | MEERUT | UTTAR PRADESH | 250002 | ₹10.2 Cr+₹1.4 Cr (15.6%) | L3 | Rejected-Finance Higher than lowest tender |
| 4 | L4₹10.3 Cr+₹1.5 Cr (17.1%)Rejected-Finance | ₹10.3 Cr+₹1.5 Cr (17.1%) | L4 | Rejected-Finance Higher than lowest tender |
| 5 | L5₹11.7 Cr+₹3.0 Cr (33.7%)Rejected-Finance 183 MG ROAD JUNGLIGHAT PORT BLAIR 744103 | PORT BLAIR | SOUTH ANDAMANS | ANDAMAN NICOBAR ISLANDS | 744103 | ₹11.7 Cr+₹3.0 Cr (33.7%) | L5 | Rejected-Finance Higher than lowest tender |
Tender Value
Refer Docs
EMD Value
₹11.0 L
Closing Date
21 Mar 2025, 6:00 pmClosed
Sh Somesh Kumar IDSE CE
HQ Chief Engineer Kolkata Zone, Military Engineer Service, Ballygunge Maidan Camp Gurusaday Road Kolkata-700019
PROVN OF 8 X OFFRS MD ACCN AT RASPUNJA MIL STN
2024_MES_684622_2
89096/E8
Open Tender
Civil Works
Lump-sum
560 days
Raspunja Kolkata
Please refer Tender documents.
8 documents required · 8 mandatory
₹3,000
GE (Central) Kolkata
₹11.0 L
Yes
26 Jun 2025
21 Feb 2025
28 Mar 2025
21 Feb 2025
21 Mar 2025
7 Mar 2025
Amount
Sch 'A' Part -I (Building Works) Note:- This Sch is not pre-priced by MES and the pre-priced rate indicated as "Rs 0.00" under Col 5 signifies this fact only.
Offrs MD Accn G+2
Offrs MD Accn single storey
Garage
Lumpsum price worked out by the tenderer/ bidder for SITE CLEARENCE, AREA DEVELOPMENT, as listed in Schedule ‘A’ Part-II on Serial Page No. 33
Lumpsum price worked out by the tenderer/ bidder for GARBAGE BIN as listed in Schedule ‘A’ Part-III on Serial Page No. 34
Lumpsum price worked out by the tenderer/ bidder for INTERNAL WATER SUPPLY as listed in Schedule ‘A’ Part-IV on Serial Page No. 35
Lumpsum price worked out by the tenderer/ bidder for INTERNAL ELECTRIC SUPPLY as listed in Schedule ‘A’ Part-V on Serial Page No. 36 to 40
Lumpsum price worked out by the tenderer/ bidder for ROAD/PATH /CULVERT/ PAVED AREA as listed in Schedule ‘A’ Part-VI on Serial Page No. 41 to 44
Lumpsum price worked out by the tenderer/ bidder for AREA DRAINAGE as listed in Schedule ‘A’ Part-VII on Serial Page No.45 & 46
Lumpsum price worked out by the tenderer/ bidder for SEWAGE DISPOSAL as listed in Schedule ‘A’ Part-VIII on Serial Page No. 47 & 48
Lumpsum price worked out by the tenderer/ bidder for FENCING AND STEEL GATE as listed in Schedule ‘A’ Part-IX on Serial Page No. 49 to 51
Lumpsum price worked out by the tenderer/ bidder for RETAINING WALL as listed in Schedule ‘A’ Part-X on Serial Page No. 52 & 53
Lumpsum price worked out by the tenderer/ bidder for EXTERNAL WATER SUPPLY as listed in Schedule ‘A’ Part-XI on Serial Page No. 54& 55
Lumpsum price worked out by the tenderer/ bidder for EXTERNAL ELECTRIC SUPPLY as listed in Schedule ‘A’ Part-XII on Serial Page No. 56 to 58
Sch 'A' Part-XIII (MISC B&R AND E&M ITEMS) Note : This schedule is not pre-priced by MES and the pre-priced rate indicated as "Rs 0.00" under Col. 5 siginifies this fact only.
ROAD/PATH/CULVERT Approved earth from outside MoD land
EXTERNAL WATER SUPPLY Materials and Labour for Construction of brick masonary valve pit chamber of size 1.2 x 1.2 x 1.2 Mtr internal dimension using sub class-'B' bricks in CM (1:6) plastering in cement mortar (1:4) externally & internally extended to 15 cm below ground level including PCC bed 10 cm thick in PCC 1:3:6 Type C2 with MS frame fabricated by angle of size 40 x 40 x 6mm complete with top cover of 3 mm thick MS sheet & locking arrangement and painting with two coats of synthetic enamel over a coat of red oxide primer including demolition of old unserviceable damged valve pit complete all as specifed & directed.
Materials and Labour Cutting / boreing of existing road / path, hardstanding etc and water pipe to protection with iron cover plate for passing cable or water pipe and making good the disturbed road top surfaces with following cement concrete all type, using of suitable depth and finished with speed breaker complete all as specifed & directed by Engineer-in-Charge.
EXTERNAL ELECTRIC SUPPLY Supply & Fixing PVC cable terminal boxes, outdoor type of size 155 mm x 210 mm x 92 mm with MCB SP 6 to 32 Amps including all necessary fittings and connection including one complete all as directed by the Engr-in-Charge.
Suply install commissioning and testing floor mounted outdoor cubical type LT Feeder Pillar Box (CPRI tested and confirming to IEC61439 Part 1&2 ) of size 1800 x 1650 x900 fabricated out of 3.15 mm thick CRCA Sheet and angle iron 50 x 50 x 6 mm frame factory made totally enclosed dust and vermin proof both side hinge opening arrangement on front and back with locking arrangement cable entry and exit from bottom with cable glands and gaskets, Aluminium bus bar fixed on porcelin insulators with internal wiring with suitable size of Aluminium strips to be used for incoming and outgoing connection of all switches/MCCB'S & Bus -bar . of 300 Amp 4 WAY . Bus- bar shall be insulated with colour code sleeves/tapes and to be connected with Aluminium lugs, including two coats of synthetic enameled paint on the surface externally & internally over a coat of red oxide primer paint incl locking arrangements . necessary PCC (1:3 :6) TYPE C2 as in foundation all as directed , comprising of the followings: (LT Feeder pillar box should be powder coated colour)
INCOMER :- (a) 200 Amp MCCB 4 Pole 35 KA - 01 No OUTGOING:- (b) 63 Amp MCCB 4 Pole 16 KA - 03 Nos ( 02 working + 01 spare) (c) MCB TPN 63 Amps including street light timer system with ML2 contactor system. (d) Bus bar 300 Amp 4 way. (e) Digital type Ameter, range 0 to 630 Amp with slector switch and CT. (f ) Digital type Ameter, range 0 to 500 Volt with slector switch and PT. (g) Indicator lamp RYB.
Suply install commissioning and testing floor mounted outdoor cubical type LT Feeder Pillar Box (CPRI tested and confirming to IEC61439 Part 1&2 ) fabricated out of 3.15 mm thick CRCA Sheet and angle iron 50 x 50 x 6 mm frame factory made totally enclosed dust and vermin proof both side hinge opening arrangement on front and back with locking arrangement cable entry and exit from bottom with cable glands and gaskets, Aluminium bus bar 4 Nos fixed on porceling insulators with internal wiring with suitable size of Aluminium strips to be used for incoming MCCB 200 A rating and outgoing connection of all switches / MCCB’s and Bus – Bar of 300 Amp 4 way. Bus- bar shall be insulated with colour code sleeves/tapes and to be connected with Aluminium lugs, including two coats of synthetic enameled paint on the surface externally & internally over a coat of red oxide primer paint incl locking arrangements . necessary PCC (1:3 :6) TYPE C2 as in foundation all as directed , comprising of the followings: (LT Feeder pillar box should be powder coated colour)
INCOMER:- (a) 200 Amp MCCB 4 pole 35 KA - 01 No OUTGOING:- (b) Bus bar 300 Amp 4 way. (c) Digital type Ameter, range 0 to 630 Amp with slector switch and CT. (d) Digital type Ameter, range 0 to 500 Volt with slector switch and PT . (e) Indicator lamp RYB .
Supply & Fix two in one CP bip tap etc completed all as specified and directed.
KAIZEN INDUSTRIES (BID ID -3261501)
M/S N C BANERJEE AND SON (BID ID -3261535)
M/s Gupta Construction (BID ID -3267386)
DNS CONSTRUCTION COMPANY (BID ID -3267873)
SIBAL AND SIBAL (BID ID -3267573)
Bidder Name
Hindustan Traders
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .