Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹41.7 LAccepted-AOC | L1 | Accepted-AOC Being lowest | |
| 2 | L2₹44.7 L+₹1.5 L (3.43%)Rejected-Finance | L2 | Rejected-Finance Being not lowest | |
| 3 | L2₹45.4 L+₹2.2 L (5.02%)Rejected-Finance FLAT NO A 402 SHANKAR HEIGHTS NEAR CHETANA SCHOOL HAJI MALANG ROAD KALYAN EAST THANE MUMBAI 421 306 | THANE | MAHARASHTRA | 421306 | L2 | Rejected-Finance Being not lowest | |
| 4 | L4₹45.6 L+₹2.4 L (5.63%)Rejected-Finance | L4 | Rejected-Finance Being not lowest | |
| 5 | L5₹40.4 L−₹2.8 L (6.37%)Rejected-Finance 27 19 F F D BLOCK CHATTARPUR EXTN SOUTH WEST DELHI DELHI 110075 | SOUTH WEST DELHI | DELHI | 110075 | L5 | Rejected-Finance Being not lowest |
Tender Value
Refer Docs
EMD Value
₹1.4 L
Closing Date
19 Nov 2022, 6:00 pmClosed
CWE Ambala
Headquarter Commander Works Engineer Ambala Mansfield Road Ambala Cantt
SPECIAL REPAIRS TO BLDG NO. P-1/161 (SM BK) COMBINATION OF 04 (FOUR) BLDGS INCL ADJECENT TOILET BLOCK CONNECTED WITH CORRIDORS AT PIRU SINGH LINES (EARSTWHILE KE LINES) OF MH UNDER GE (SOUTH) AMBALA CANTT
2022_MES_553293_1
CWE/AMB/SOUTH-04 OF 2022-23
Open Tender
Civil Works
Item Rate
180 days
Ambala Cantt
All as per tender documents
9 documents required · 9 mandatory
₹1,000
GE SOUTH AMBALA CANTT
₹1.4 L
Yes
7 Jan 2023
23 Sept 2022
21 Nov 2022
23 Sept 2022
19 Nov 2022
7 Nov 2022
23 Sept 2022 - 5 Nov 2022
Amount
SCHEDULE A PART I (B/R WORKS) Material and labour for plain cement concrete (1:4:8) type D-2 using 40mm graded mechanically crushed stone aggregates as in foundation filling and mass concrete complete all as specified and directed.
Material and labour for 25mm thick plain cement concrete (1:2:4) type B-1 using 20mm graded mechanically crushed stone aggregates as in flooring, rough finished without using extra cement complete all as specified and directed.
Material and labour for Machine cut kota stone slab flooring 20-22mm thick of stone size not less than 550mmx550mm over and including screed bed or bedding layer of 20 mm thick in CM 1:6, for laying floor finishes cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including cutting,rubbing and polishing (granite finish) complete all as specified and directed.
Material and labour for machine cut kota stone slab 16-18 mm thick laid on verticle surface or skirting, dado, riser to steps, pillars etc. of stone size not less than 550mmx550mm over and including 10mm thick plaster in cement mortar (1:4) on brick work or concrete surfaces and jointed & pointed with grey cement slurry mixed with pigment to match shade of the slab including cutting, waste, rubbing and polishing (Granite finish) complete all as specified and directed.
Material and labour for premium quality, joint free, non skid coloured ceramic tiles (Square/rectangular), area of each tile exceeding 0.18 sqm and not exceeding 0.38 sqm and 7 to 8 mm thick, laid in floor over and including cement screed bed 15mm thick in cement mortar (1:4) and set and jointed in neat cement slurry @ 3.00 kg/Sqm and pointed in white or coloured cement to match the surface complete all as specified and directed.
Material and labour for premium quality, joint free, non skid coloured ceramic tiles (Square/rectangular), area of each tile exceeding 0.18 sqm and not exceeding 0.38 sqm and 7 to 8 mm thick,as in daddo/skirting over and including cement screed bed 10mm thick in cement mortar (1:4) and set and jointed in neat cement slurry @ 3.00 kg/Sqm and pointed in white or coloured cement to match the surface complete all as specified and directed.
Material and labour for premium quality, joint free, non skid coloured ceramic tiles (Square/rectangular), area of each tile exceeding 0.11 sqm and not exceeding 0.18 sqm and 7 to 8 mm thick, laid in floor over and including cement screed bed 15mm thick in cement mortar (1:4) and set and jointed in neat cement slurry @ 3.00 kg/Sqm and pointed in white or coloured cement to match the surface complete all as specified and directed.
Material and labour for premium quality, joint free, printed glazed coloured designer ceramic tiles of size 300 x 450 x 7mm thick on vertical surfaces of walls over and including 10mm thick rough finished plaster in cement mortar (1:4), and set and jointed in neat cement slurry @ 3.00 kg/Sqm and pointed in white or coloured cement to match the surface complete all as specified and directed.
Dismantling floor, hearth, or wall tilling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premise and removal of debries to distance exc 250 mtr but n exc 500 mtr complete all as specified and as directed.
Material and labour for 100 mm thick PCC (1:2:4) type B1 (using 20mm graded stone aggregates) as in flooring, hardstanding, path/paving etc., finished even and smooth with using extra cement complete all as specified and as directed.
Material and labour for heavy duty ceremic parking tiles (Endura tiles) of pattern as approved, 10mm thick, set, jointed and pointed in neat cement slurry with grey cement and pigment to match as in floor, over and including screeding bed or bedding a layer of 15mm thick CM 1:6, complete all as specified and as directed.
Demolition of brickwork or stone/ boulder masonary, built in cement mortar including all quoins, arches, pillars etc, including stacking of servisable bricks and removal of debries to distance exc 250 mtr and n exc 500 mtr complete all as specified and as directed.
Material and labour for brickwork, with old size sub class 'B' bricks, straight or curved on plan to any radius, exceeding 6 metre mean radius built in cement mortar 1:6 complete all as specified and as directed.
Taking down cement or cement lime plaster, of any description, on brick or stone walls etc including raking out joints, hacking for key, scrubbing down with water etc, and removal of debries to distance exc 250 mtr and n exc 500 mtr complete all as specified and as directed.
Material and labour for rendering 15 mm thick on fair faces of brick work or concrete surfaces of wall in cement mortar 1:4, finished even and smooth without extra cement all as specified and as directed.
Material and labour for rendering 15 mm thick on fair faces of brick work or concrete surfaces of wall in cement mortar 1:6, finished even and smooth without extra cement all as specified and as directed.
Material and labour for rendering 10 mm thick on ceiling in cement mortar 1:3, finished even and smooth without extra cement all as specified and as directed.
Taking down chowkats or frames with shutter, area exceeding 1.50 Square metre and not exceeding 4.00 Square metre (without taking off shutters from frame) and removing from site, including cutting holes in wall/concrete for taking out existing hold fasts and making good the disturbed portion of jambs and adjoining surfaces in CM (1:3) and finishing the surfaces to match with existing finish including removal of serviceable/unserviceable material from site complete all as specified and directed.
Taking down chowkats or frames with shutter, area not exceeding 1.50 Square metre (w/o taking off shutters from frames) and removing from site, including cutting holes in wall/concrete for taking out existing hold fasts and making good the disturbed portion of jambs and adjoining surfaces in CM (1:3) and finishing the surfaces to match with existing finish including removal of serviceable/unserviceable material from site complete all as specified and directed.
Supply and fixing of pressed steel frames for doors of size 125x60mm, 1mm thick, with one or more rebates including, hold fasts of 25mm x 4mm MS FI, 25cm long, 6 Nos in each chowkhat, necessary lugs, 4 Nos 100 mm MS butt hinges medium weight, cold rolled, welded for each frame, lock strike plate, including sanding, tarring backs of chowkhats, PCC 1:3:6 type C-0 filling in frame and for holdfast, 2 Nos 12 mm dia tie bars at the bottom of frame and one shop coat of red oxide primer etc complete all as specified and as directed. Note:- Rates quoted are inclusive of hinges, holdfast, lugs, PCC for hold fast and chowkhat filling, tie bars and one coat of red oxide primer.
Supply and fixing 30 mm Flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides etc., sizes of members of shutters as specified in SSR Part-I, Section 8, Clause 8.25, complete all as specified and as directed. Note: Manufacturers test certificate shall be submitted before incorporation.
Material and labour for second class hard wood glazed and skeleton shutters, 30mm thick, open rebated and prepared to receive glass, gauze, etc. devided into squares with plain chamfered or rounded, mitred and rebated sash bars edges of framing plain any numbers; sizes of members of shutters as specified in SSR Part I, Section 8, clause 8.24 (a); supplied and fitted to chowkats all as specified and directed.
Supply and fixing of steel window box type, using ERW hollow 'P' section, factory made, comprising double frame for and including gauged and glazed skeleton shutter, 30mm thick, jointed internally with flat iron 25x3mm complete including hinges, handle, tower bolts, stops, lugs etc. all as shown on drawing No. TD-219 sheet 1/3 to 3/3 of HQ CE Chandigarh Zone as applicable complete all as specified and as directed. Note: (i) For the purpose of measurement and payment double shutter both glazed and gauzed with frame shall be considered as one unit. (ii) Unit rate quoted against this item shall also include the iron mongery and grill 10 mm square bar irrespective of whatever shown on drawings and one shop coat of zinc chromate primer . The pattern of grill shall be all as shown on drawing (iii) Glazing, wire mesh and painting shall be measured and paid for separately. (iv) The drawings may be referred from GE office or from this office during working hours.
Supply and fixing of factory made solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube, suppling & fixing in pening as per specification & drawing complete all as specified and as directed.
Supply and fixing of Factory Made Solid PVC Moulded Door Shutter, 28 to 30mm thick (stiles), with 2, 4, or 6 raised panel design with 2mm thick Moulded PVC Sheet on the front face & 2mm plain colour PVC sheet on back face, supplying & fixing in frame at site as per specification & drawing complete all as specified and as directed.
Supply and fixing of sheet glass, 3mm thick, ordinary quality and glazing with oil putty in squares not exceeding 0.5 sqm. in each pane complete all as specified and directed.
Supply and fixing of stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.18mm and fixed with stainless steel wire staples complete all as specified and as directed.
Material and labour for 200mm long aluminium anodised, barrel tower bolts of extruded section and fixed complete all as specified and as directed.
Material and labour for 150mm long extruded aluminium alloy handles, cast type, anodised complete all as specified and as directed.
Supply and fixing of aluminium alloy anodised, 300mm long, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed complete all as specified and as directed.
Material and labour for floor door stopper of aiuminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor with overall length of cover plate 150mm complete all as specified and as directed.
Supply and fixing of mild steel, 150mm long, ordinary rat tail rod pattern springs for door including roller and roller plate, ISI marked complete all as specified and as directed.
Material and labour for preparation of new wooden surfaces, of any description not otherwise described, over 10 cm width or girth and applying two coats of approved colour synthetic enamel paint, over a coat of pink primer complete all as specified and as directed.
Material and labour for preparation of old steel surfaces, of any description not otherwise described, over 10 cm width or girth and applying one coat of approved colour synthetic enamel paint complete all as specified and as directed.
Material and labour for preparation of new steel surfaces, of any description not otherwise described, over 10 cm width or girth and applying two coats of approved colour synthetic enamel paint complete all as specified and as directed.
Material and labour for preparation of new steel surfaces, of any description not otherwise described, over 10 cm width or girth and applying two coats of approved colour synthetic enamel paint over a coat of red oxide primer complete all as specified and as directed.
Material and labour for PCC (1:3:6) type C2 (using 40mm crushed graded stone aggregates), 75 mm thick, as in plinth protection, finished even and smooth without using extra cement and laid in bays complete all as specified and as directed.
Material and labour for preperation of newly plastered surfaces of walls and applying two coats of oil bound distemper over and including 2.-3mm thick wall putty including alkali resistant primer using roller including necessary saffoldings etc., complete all as specified and as directed.
Material and labour for preperation of new plastered surfaces of walls and applying two coats of cement base paint complete all as specified and as directed.
Material and labour for preperation of old decorated plastered or unplastered surfaces of walls and applying two coats of cement base paint by complete brooming down or steel wire brushing, scraping down smoke, complete all as specified and as directed.
Material and labour for preperation of old decorated plastered or unplastered surfaces of walls/ceiling by steel wire brushing, scraping down smoke soot, moulds, moss and efflorescent salts and treating oil and greasy spots, using roller including necessary saffoldings etc.,and applying two coats of oil bound distemper complete all as specified and as directed.
Demolition of cement concrete (unreinforced) of any description, in any position not otrherwise specifically provided for and removal of debries to distance exc 250 mtr but n exc 500 mtr complete all as specified and as directed.
Demolition of cement concrete (reinforced) of any description, in any position not otrherwise specifically provided for including cutting of reinforcement to facilitate demolition and removal of debries to distance exc 250 mtr but n exc 500 mtr complete all as specified and as directed.
Material and labour for PCC 1:2:4 type B-1 using 20mm graded crushed stone aggregates, as in surface channels, drain and incl scaffolding etc., complete all as specified and directed.
Material and labour for RCC 1:2:4 type B-1 using 20mm graded crushed stone aggregates, as in beam, slab supported on wall, shelves and similar work etc., complete all as specified and directed.
Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) rough finished flat surfaces complete all as specified and directed.
Material and labour for mild steel TMT bars Fe 500/550 D, 10mm dia and over, as in reinforcement, cut to length, bent to shape required including cranking, bending spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed.
Material and labour for mild steel TMT bars Fe 500/550 D, 8mm dia and over, as in stirrups, spaces, binders, cut to length, bent to shape required including cranking, bending spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed.
Material and labour for roof treatment over roofs comprising of following works:- (i) Taking down of all brick tiles with tar felt (if any) and mud phuska in any thickness and removal from site and cleaning the surface with water and wire brushes. (ii) 50mm thick PCC 1:2:4 type B-0 using 12.5mm graded stone aggregates mixed with WPC @2% by weight of cement as in levelling course etc., including roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust,etc. and brushing the surface with neat cement slurry @ 3.0kg of cement per sq. metre. (iii) Applying a coat bitumious primer @ 0.40 ltr/ Sqm of density 0.87 to 0.89 kg/ltr at 25' C temprature and viscosity 70-160 cps. (iv) Laying 3mm thick APP(atactic polypropylene polymer) modified prefabricated, five layer, weight not less than 3.60 kg/Sqm, water proofing membrane, black finish, reinforced with non woven polyster matt over the primer coat with overlap of 100mm at the sides and 150mm at the end, the layer membrane shall be laid using butane gas torch and sealing all joints etc after preparing the surface. (v) Applying two coats of water proofing paint with aluminium finish on top of laid APP surfaces including preparation of surface Notes:-(i) Joint strength in logitudinal and transverse direction at 23'Cat 650/450 N/5 cms (ii) Tear strength in logitudinal and transverse 150'C when tested in accordance with ASTM (d-5147) (iii) The laying of membrane shall be got down through the authorised applicator of manufactures of membrane only.(iv) The contractor will carry out ponding test after application of APP treatment before claiming payment.
Dismantling of plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings and removal from site complete all as specified and as directed.
Supply and fixing of pre-painted galvalume, aluminuim zinc coating, GI based corrugated steel sheet, 0.50mm thick, conforming to IS-15961, of red colour, having tensile strength of 550 MPa, as in roof covering/cladding to wall, fixed with self tapping screws including taking down of old sheets of any descriptions as existing on site complete all as specified and as directed. Note- The sheets shall have super durable polyester quality paint of approved colour, 150 gm/sqm total on both sides, suitable for exterior application conforming to IS-15965.
Supply and fixing for pre-painted galvalume, aluminuim zinc coating, GI based Plain steel sheet, 0.50mm thick, of red colour, having tensile strength of 550 MPa, as in roof covering/cladding to wall, fixed with self tapping screws including taking down of old sheets as existing on site complete all as specified and as directed. Note- The sheets shall have super durable polyester quality paint of approved colour, 150 gm/sqm total on both sides, suitable for exterior application conforming to IS-15965.
Supply and fixing GI Metal Suspended Ceiling System at all heights of Perforated with Fleece 600x600x0.5mm TEGULAR EDGE TILES in global white Powder Coated with 60-70 Micron front coating laid on 24mm wide Tee grid – strong section flanges colour white having stitching on the Main Runner, 600 mm and 600 mm Cross Tees with web height of 26mm. The tiles should have Humidity Resistance (RH) of 100%, with Light Reflection of 62%. The main runner spaced at 600 mm max (centre to centre) securely fixed to the structural soffit . Hangers (GI wire of 4 mm dia) to be fixed by approved roof plug, level adjusters and screws etc at 600x600 intervals.The First/Last suspension system at the end of each main runner should not be greater than 450mm from the adjacent wall. Flush fitting 600mm long cross tees to be interlocked between main runners to form 600 x 600 mm with grid module(24X38X0.3mm).Cut cross tees longer than 600mm require independent support. 600 x 600mm module to be formed by fitting 600mm long flush fitting cross tees centrally between the 600 mm cross tees. Perimeter trim to be wall angles of size 3000x22x22mm, secured to walls at 450mm max (centre to centre), including PVC clips to hod the ceiling tile including taking down of old ceiling of any descriptions as existing and removal from site complete, all as specified and as directed.
Supply and fixing steel tubes, 50mm bore, 'medium grade' galvanised, fixed in walls with all fittings ,as in additional support of ceiling hanging wire, etc., including cutting the holes and making good in existing wall surface, complete all as specified and as directed.
Supply and finxing in replacement, 110mm PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls, complete all as specified and as directed.
Material and labour in replacement, for 110mm PVC (SWR) bends with access door including jointing with solvent cement, complete all as specified and as directed.
Supply and fixing in replacement mild steel powder coated decorative curtain rod, 20mm dia, fixed with decorative brackets, stop roller and funnels at the end for each cut length including taking down of old unseviceable rod, complete all as specified and directed.
Supply and fixing in repair of GI tubing, ISI Marked, 20mm bore, `medium grade, with all fittings and fixed complete to walls and ceilings or laid in floors including necassary cutting/chasing/pinning in wall and making good the disturbed surfaces as per existing whereever required , including taking down of old tubing as existing at site and removal, complete all as specified and as directed.
Supply and fixing in repair of GI tubing, ISI Marked, 15mm bore, `medium grade, with all fittings and fixed complete to walls and ceilings or laid in floors including necassary cutting/chasing/pinning in wall and making good the disturbed surfaces as per existing whereever required , including taking down of old tubing as existing at site and removal, complete all as specified and as directed.
Supply and fixing of water storage tank of 1000 ltr capacity, HDPE triple layer, cylindrical, vertical with closed top and FDA approved, 100% UA stabilized, rust proof, ISI marked, fixed and hoisted in position on staging or roof complete with locking arrangement including over flow pipe, air lock pipe, brass valve 20 mm high pressure with polythene float and flynut, ISI marked, screwed and suitable for iron pipe 20 mm bore including taking down of old tank of any descrption and removal from site complete all as specified and directed. Note:- Tank shall be white and make of tank shall be engraved on the tank.
Supply and fixing in repairs, vitreous china squatting pan of Orissa pattern, size 580mmx440mm, white (Ist quality) with ‘P’ or ’S’ trap of PVC, with front or back inlet and integral foot rests of any pattern including provision of lime concrete bedding for fixing and making good to existing floor surface to match with the existing surface and connection to flush pipe, trap, anti syphonage pipe, etc including taking down and removal of existing unserviceable squatting pan of any description and size complete all as specified and directed.
Supply and fixing in repairs of angle valve, 15mm bore, fancy type, chromium plated, cast copper alloy, screwed down, high pressure, with capstain head, heavy with adjustable wall flange, with crutch or butterfly handle screwed both ends for iron pipe or for unions and fixed and taking down and removal of existing unserviceable angle valves/valves of any description and size complete all as specified and as directed. Note : Weight of angle valve shall not be less than 0.575 Kg.
Supply and fixing in repairs of bib tap, 15mm bore, fancy type long body , chromium plated, ISI marked, cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule or union and fixed and taking down and removal of existing unserviceable tap of any description and size complete all as specified and as directed.Note : Weight of bib tap shall not be less than 0.575 Kg.
Supply and fixing in repair, vitreous china wash hand basin, white colour, flat back, of size 550x440mm, ISI marked, with and including 2 Nos.CI brackets embedded in cement mortar 1:4, PVC waste pipe, 45cms long, fixed to walls, 15mm dia PVC connections and chromium plated waste coupling CP of appropriate size, pillar tap 15mm cast copper alloy CP,including taking down/removal of existing unserviceable wash hand basin of any description and size and making good the disturbed surfaces to match with existing surfaces complete all as specified and directed.
Supply and fixing in repairs of 10 litre capacity, virgin polypropylene cistern, ISI marked, coloured, low level, valveless syohonic action type, 45cm PVC connection with PVC bend/flush pipe complete and making all connections including taking down existing high or low level unserviceable flushing cistern and making good the disturbed surface to match with the existing surface complete all as specified and directed.
Supply and fixing in repair towel Rail 450mm long of PTMT fixed with and including chromium plated brass screws and wooden/plastic cleats complete all as specified and directed.
Supply and fixing in replacement of brass chromium plated shower rose,125mm size, with or without swivel joints, any size. including fixing to steel pipe or union complete all as specified and as directed.
Supply and fixing in repair of pegs set of 06 Nos, powder coated aluminium body, fixed with chromium plated with screws complete all as specified and as directed.
Supply and fixing in repair of PVC connections 15mm size with PTMT nuts of length 450mm with PVC washers on both ends, complete all as specified and as directed.
Material and labour for rough cast plastering over and including 15mm thick rendering in CM 1:3 complete all as specified in Clause14.22 of MES Schedule Part-I and as directed. Note: 1. Rough cast finish shall be provided as under:- After applying under coat of CM 1:3 and while it is still in plactic state the rough cast mixture consisting of crushed stone or fine aggregate (which is generally of size between 4 to 8 mm depending on the texture required) mixed with coarse sand and cement in the ratio of 1:1:1 shall be applied and finished even. The mix of cement and sand shall be made slightly loose/wetter than normal for rendering to ensure that larger aggregates are thoroughly covered. 2. Contractor's quoted rate shall include all above provisions and no extra shall be admissible on this account.
Material and labour for preparation of exposed brick wall surface by cleaning the surface with wire brush to remove all the dirt/loose materials from the bricks and form the joints between the bricks, washing the prepared surfaces with diluted HCL acid (dilution ratio of 1:50) for three times a day for two days and after the acid wash surface should allowed to be air dried for one day, complete all as specified and as directed. Note: Further treatment over the surface so achieved will be carried out only after approved of the same by GE.
Material and labour for carrying out efflorescence treatment to exposed and prepared wall surface in item No 72.00 for the area all as specified and as directed. (a) Prime the prepared surface with one of the following product mixed with cement in 1:1 ratio as bonding agent :- (i) Pidicrete URP of M/s Pidilite, (ii) Sika Latex of M/s Sika, (iii) Nitobond SBR Latex of M/s FOSROC. (b) Immediately after priming the surface PMM (Polymer Modified Mortar) to be applied "BY HAND" while the prime is tacky. PMM should be prepared by mixing one of the following compounds in CM 1:3 as per manufacturer's instructions:- (i) Pidicrete URP of M/s Pidilite, (ii) Sika Latex of M/s Sika, (iii) Nitobond SBR Latex of M/s FOSROC. (c) PMM surface should be allowed to dry for one day. After that it should be painted with two coats of one of the following compound mixed with cement only in ratio of 1(slected compound): 1:5(cement):- (i) Pidicrete URP of M/s Pidilite, (ii) Sika Latex of M/s Sika, (iii) Nitobond SBR Latex of M/s FOSROC. (d) Now apply two coats of one of the following compound over the surface including 15mm thick plaster in CM 1:3 complete as per manufacturer's instructions:- (i) Pidifin 2K of M/s Pidilite, (ii) Brush Coat of M/s Sika, (iii) Brush Bond of M/s FOSROC. Note: Both coats should be perpendicular to each other and gap between two coats shall be minimum 6 hours. (e) Sprinkle loose coarse sand after second coat while surface is tacky. Note: (i) The efflorescence treatment shall be carried out by the manufacturer or his authorised representative only. (ii) The efflorescence treatment shall be carried out after taking down existing plaster redoing external/internal plaster under respective items. (iii) Every stage of work shall be approved by GE, then only next layer shall be executed by the contractor.
Material and labour for preperation of new plastered surfaces of ceilings and applying two coats of white wash complete all as specified and as directed.
SCHEDULE A PART II (E/M WORKS) Taking down carefully any type of point wiring (light, fan, socket or power) complete with fittings such as switches, ceiling roses, pendants, regulators, sockets, tube light fittings with all accessories etc., and/or drawing out from existing conduit/batten and removal of materials from site and making good the disturbed surfaces of wall, floors, ceiling etc to match with the existing surfaces with matching OBD/White wash/Distemper complete all as specified and as directed.
Material and labour for concealed point wiring using approved colour coding as per IS, with multi stranded copper conductor 1.5 sqmm (Nominal area), single core, FRLS-H, 1100 volts, ISI marked, PVC insulated and unsheathed stranded cable drawn through and including non metallic, medium grade PVC concealed conduit not less than 25.00mm to 32.00mm dia and its fittings, including cutting chasing on wall/ceiling, including all tees, bell mouth pieces and fixing accessories such as couplers, saddlers, pipe hooks etc, PVC junction boxes, ISI marked, including 1.5 sqmm single core PVC insulated and unsheathed FRLS-H cable, 1100 volt grade with multi stranded copper conductor green colour as earth continuity conductor upto common earth and connecting to common earth dolly with and including MS flush boxes of 2 to 18 modules with inner and outer cover plates, confirming to IS 5139 of 1969 and IS 14772 of 2000 for fixing modular switch sockets for one light point (For flourescent Tube/ LH, Bldg Security light, Mirror light)/bell point controlled by one one way switch complete all as specified and as directed. Notes :- (i) Switch, socket, ceiling rose, lamp holder, bell, bell push and fan regulators to be measured and paid for separately. The quoted rates are deemed to be included for providing cover plates and MS flush boxes as required at site. (ii) PVC Conduit conforming to IS 9537 part I & III. (iii) All chases will be cut by chase cutter only and surfaces shall be make good as per existing surfaces. (iv) The concealed conduits and MS boxes as fixed against new point wiring, shall be verified by Engineer-in-Charge before making good the surfaces by plastering and other finishes.
Description all as per item No 76.00 here in before but for ceiling fan/ exhaust fan point.
Description all as per item No 76.00 here in before but for socket out let point 5 Amps on same board.
Description all as per item No 76.00 here in before but for socket out let point 5 Amps on independent board.
Description all as per serial item No.76.00 above, but for one socket point 3 pin 16 and 6 Amps (independent) power point, with 2.5 Sqmm PVC, FRLS-H, unsheathed, multistranded cable, 1100 volts grade, ISI marked, including 2.5 Sq mm size, green colour, PVC insulated FRLS-H, continuous copper earth wire and connected to common earth dolly complete all as specified and as directed.
Supply and fixing of switch modular, 6 Amps, one way, one module, flush type, single pole, 230 volt, ISI marked complete all as specified and directed.
Supply and fixing of switch modular, 16 Amps, one way, two module, single pole, 230 volts, ISI marked complete all as specified and directed.
Supply and fixing of socket modular, 2/3 pin, 5/6 amps, one way, two module, single pole, 230 volts complete all as specified and directed.
Supply and fixing of socket outlet, modular, 2/3 pin, 6/16 Amps, one way, two module, single pole, 230 volts, ISI marked complete all as specified and directed.
Supply and fixing ceiling rose surface bakelite 65x50mm, 3 terminal complete all as specified.
Supply and fixing of fan regulator, modular, 120 watt, two module, 230 volts, 50 Hz, AC supply, suitable for ceiling fan any type/make/sweep complete all as specified and as directed.
Supply and fixing lamp holder, PVC/polycarbonate type with back plate suitable for batten fittings,complete all as specified.
Supply and fixing in replacement LED tube light channel for 18-20 watt tube light fitting, 4 ft, aluminium housing body, with and including 18-20 watt LED tube rod , with drivers, 220-240 Volt, 50 Hz connecting up with 2/3 core 1.5 sq mm flexible copper conductor cable from ceiling rose to connector block of light fitting including disconnecting and taking down existing light fitting and removal complete all as specified and directed.
Supply and fixing of surface mounted, mirror light, LED tube light wall mounting light fitting, high efficient PMMA diffuser, aluminium housing in CRCA body suitable for and including 10 watt LED tube, high efficient, AC 220-240 volts,50 Hz, and compact and energy efficient, epoxy powder coated, CRCA sheet, connecting with copper conductor flexible cable of size 0.50 Sqmm from ceiling rose to connector of the light fitting including disconnecting and taking down of existing old unserviceable light fitting of any description and removal from site complete all as specified and directed.
Supply and fixing sheet metal enclosures vertical distribution board VTPN, (MCCB DB) 4 ways, double door , 415 volts with 200 amps rated bus bar IP 54 protection, with shrouded neutral bar and insulated bus bar and earth link, with and including MCCB 4 pole, 125 Amps 25 KA as incomer and MCBs as out going complete with making suitable size of MS cabinet 2 mm thick dully grouted on the wall (flush) with opening arrangement including taking down the existing DB and MCBs any type and making connection with suitable size of lugs and making good the disturbed surface matching with existing surface all as specified and directed. Note:- MCB shall be measured and paid separetely.
Supply and fixing sheet metal enclosures distribution board TPN, (MCB DB) 4 ways, double door , 415 volts with 200 amps rated bus bar IP 54 protection, with shrouded neutral bar and insulated bus bar and earth link, suitable for MCB 4 pole as incomer and MCBs as out going complete with making suitable size of MS cabinet 2 mm thick dully grouted on the wall (flush) with opening arrangement including taking down the existing DB and MCBs any type making connections with suitable size of lugs and making good the disturbed surface matching with existing surface all as specified and directed. Note:- MCB shall be measured and paid separetely.
Supply and fixing sheet metal enclosures distribution board SPN 4 way,double door , IP 43 , as per IS 8623 including 100 amps fully insulated copper bus bar, insulated neutral bar, earth bar, door earthing, reversible doors, PAN assembly for easy installation and also incoming and outgoing connections with suitable size of lugs/thimbles including taking down the existing DB and MCBs any type complete all as specified and directed.
Supply and fixing sheet metal enclosures distribution board SPN 8 way,double door , IP 43 , as per IS 8623 including 100 amps fully insulated copper bus bar, insulated neutral bar, earth bar, door earthing, reversible doors, PAN assembly for easy installation and also incoming and outgoing connections with suitable size of lugs/thimbles including taking down the existing DB and MCBs any type complete all as specified and directed.
Supply and fixing sheet metal enclosures distribution board SPN 12way,double door , IP 43 , as per IS 8623 including 200 amps fully insulated copper bus bar, insulated neutral bar, earth bar, door earthing, reversible doors, PAN assembly for easy installation and also incoming and outgoing connections with suitable size of lugs/thimbles including taking down the existing DB and MCBs any type complete all as specified and directed.
Supply and fixing in replacement MCB SPN 40 -63 Amps rating ,240 volts, 50 Hz, breaking capacity 10 KA complete all as specified and directed.
Supply and fixing in replacement MCB SPN 16-32 Amps rating ,240 volts, 50 Hz, breaking capacity 10 KA complete all as specified and directed.
Supply and fixing in replacement MCB SP single pole, 240 volts, 50 Hz, breaking capacity , 6 to 32 Amps, ISI marked, complete all as specified.
Supply and fixing in replacement MCB SP single pole, 240 volts, 50 Hz, breaking capacity , 40-63Amps, ISI marked, complete all as specified.
Material and labour for sub main wiring with two single core, 4 sqmm, FRLS-H, 1100 volts grade, ISI marked, with multistranded, PVC insulated unsheathed copper conductor cable, drawn in and including rigid non metallic PVC conduit, medium grade, not less than 25 mm dia, ISI marked for housing cables, concealed in wall or ceiling including cutting chasing and making good, with accessories with and including one additional 4 sqmm, PVC insulated, stranded copper conductor, FRLS-H, green colour for earth continuity conductor connected to common earth dolly including taking down old unserviceable sub main wiring of any type and making good the disturbed surface complete all as specified and as directed. Note- Three runs of 4.0 sqmm cable and one run of concealed conduct shall be measured as one unit.
Material and labour for sub main wiring with two single core, 6 sqmm, FRLS-H, 1100 volts grade, ISI marked, with multistranded, PVC insulated unsheathed copper conductor cable, drawn in and including rigid non metallic PVC conduit, medium grade, not less than 25 mm dia, ISI marked for housing cables, concealed in wall or ceiling including cutting chasing and making good, with accessories with and including one additional 6 sqmm, PVC insulated, stranded copper conductor, FRLS-H, green colour for earth continuity conductor connected to common earth dolly including taking down old unserviceable sub main wiring of any type and making good the disturbed surface complete all as specified and as directed. Note- Three runs of 6.0 sqmm cable and one run of concealed conduct shall be measured as one unit.
Disconnecting/dismantling old unserviceable earthing and material and labour for new earthing with galvanised earth plate electrode 600mm x 600mmx 6mm thick surrounded by charcoal and salt, buried directly in ground vertically in a pit of depth not less than 2.25m below ground level with top edge of the earth plate not less than 1.5m below normal ground level, connected to 4.00 mm GI wire earth lead by means of bolts, nuts, checks nut and washers made out of galvanized iron or steel, earth wire and thimbles protected by galvanized steel pipe 15mm dia (light grade) and connected to main switch or main control board all as shown in Electrical Plate No.3 of SSR Part-I & including necessary excavation and earth work in any type of strata, PCC (1:3:6) type C1 in pit, RCC cover slab 50mm thick in 1:2:4 type B-1 using 8mm dia TMT bars @10cm c/c both way with one 8mm dia bar as handle for lifting, 20mm dia GI medium grade watering pipe, funnel, wire wesh, charcoal or coke & salt in alternate layers, etc.all as indicated including testing on completion complete all as specified and directed. Note:- The new earthing shall be provided adjecent to old earthing site on the locations as directed by engineer in charge.
Supply and fixing in replacement of LED security light luminaire 30 watt, 230 volts, 50 Hz, made up of die cast aluminum housing with black epoxy powder coating with cover heat resistant glass, safety input voltage range 170 to 270 Volts, IP66 protection, including service brackets of GI pipe 25mm bore, light grade, of length 0.6 metre, bent to required shape, fixed with MS clamps of size 40 x 6mm flat iron strip, 150mm long and 4 Nos.8mm dia stainless steel bolts and nuts and washers and suitable reducer for connecting to GI pipe as required at site and making all required electrical connections using 3 core copper flexible cable from terminal box to ceiling rose including disconnecting complete all as specified and as directed.
Taking down ceiling fan of any size, any make or type, sealing cable end, dismantling blades for servicing and overhauling including greasing/oiling and replacing warnout bearing, bush, capacitor, locking pin, bolts, nuts, and hanging and refixing ceiling fan at the same location or other location and connecting up including connecting up with and including three core flexible cable 23/ 0.0076 size from ceiling rose to connector of fan complete all as specified and as directed.
Taking down exhaust fans, wall brackets of any size for repairs and servicing and refixing exhaust fan on same or other location and connecting up including including connecting up with and including three core flexible cable 23/ 0.0076 size from ceiling rose to connector of fan complete all as specified and as directed.
Taking down old geyser of capacity 25/50 ltrs including all necessary electrical/water connection and keeping in safe custody in store for reuse/ repairs and re-fixing the same including repalcement of unserviceable PVC connections and water connections , complete all as specified and directed.
Supply and fixing in replacement single pole and neutral sheet metal enclosure with two pin & earth plug and socket comptete with one single pole MCB 20 Amps complete all as specified and directed.
Supply and laying of LT underground cable, XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cable (heavy duty), 1100 volts grade, with stranded aluminium conductor of size 4 core, 25 Sqmm and laying in trenches including disconnecting and taking down of old unserviceable existing cable and removal complete all as specified and as directed. Note: Excavation and earth work shall be measured and paid separately.
Supply and fixing in replacement of light grade, GI tubing, of size 40mm bore, for cable protection and fixed with clamp to pole and wall with nuts and bolts complete all as specified and as directed.
Excavation in trenches not exceeding 1.50 metre wide and not exceeding 1.50 metre in depth and getting out in soft/loose soil for laying of cable complete all as specified and as directed.
Returning filling in, in soil, including spreading leveling watering and well ramming in layers not exceeding 25 cm each complete all as specified and as directed.
Removing excavated spoil/materials to a distance not exceeding 50 metre and depositing where directed at level not exceeding 1.5 above the starting point complete all as specified and as directed.
Material and labour for Sand cushioning to cable with a layer of sand 8 cm deep before laying the cable and 15 cms deep after laying the cable (punned down to 18 cms depth after laying and stretching of cable ) complete all as specified and as directed.Note:- The punned thickness 18cm shall be considered for payment purposes.
Supply and lay bricks, common burnt clay, sub class "B', old size, laid in vertical direction to cable as cable protection complete all as specified and as directed.
Supply and laying or fixing or passing through pipe, 1100 volts grade heavy duty cable with PVC insulated aluminium, stranded conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed twin core 16 sq. mm nominal cross section in service connections including taking down of all cable as existing on site, complete all as specified and directed
Note:- Amount of credit of Rs. 1,45,706.00 for retrieved materials is mentioned in Schedule of Credit Page Nos. 18 & 19R of tender documents in pdf form which will be deducted offline while acceptance of tender.
Parveen Kumar
Gupta Enterprises
M/S JAISANT CONSTRUCTION CO.
KULWANT SINGH
JS CONSTRUCTION COMPANY
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .