Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹31.1 LAccepted-AOC | L1 | Accepted-AOC Accepted being lowest bidder | |
| 2 | L2₹32.6 L+₹1.1 L (3.34%)Rejected-AOC MARYADA 111 SHIKARGARH KANHAIYA NAGAR JODHPUR 342001 | JODHPUR | RAJASTHAN | 342001 | L2 | Rejected-AOC Rejected being higher bidder | |
| 3 | L3₹34.5 L+₹3.0 L (9.58%)Rejected-AOC SARDARPURA 1ST B ROAD NEAR HANUMAN JI KA MANDIR JODHPUR RAJASTHAN 342 003 | JODHPUR | JODHPUR | RAJASTHAN | 342003 | L3 | Rejected-AOC Rejected being higher bidder | |
| 4 | L4₹38.4 L+₹6.9 L (21.8%)Rejected-AOC | L4 | Rejected-AOC Rejected being higher bidder | |
| 5 | L5₹35.4 L+₹3.9 L (12.5%)Rejected-AOC | L5 | Rejected-AOC Rejected being higher bidder |
Tender Value
₹37.2 L
EMD Value
₹74,400
Closing Date
16 Jan 2024, 6:00 pmClosed
GE AF Jodhpur
GE AF Jodhpur
SPL REPAIR TO TOILET BLOCK AND ROOF TREATMENT OF BLDG NO P137 P139 AND P140 UNDER AGE BR I AT AF STN JODHPUR
2023_MES_633832_1
8613/E8
Open Tender
Civil Works - Others
Item Rate
180 days
GE AF Jodhpur
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
GE AF Jodhpur
₹74,400
Yes
6 Feb 2024
21 Dec 2023
18 Jan 2024
21 Dec 2023
16 Jan 2024
4 Jan 2024
Amount
Taking down cement or cement lime plaster work any description from brick or stone wall etc. including raking out of joints, hacking for key, scrubbing down with water etc complete all as specified and as directed .
Demolition of reinforced cement concrete of any description and in any position not otherwise specifically provided for and removing debris outside MD land complete all as specified and directed.
M&L for cutting holes superficial area exc. 150 sq. cm but n exc 400 sq. cm into or through stone walls built in cement mortar or cement lime mortar and walls of cement concrete and making good in cement mortar 1:3 or cement concrete 1:2:4 Type B-1 as required complete all as specified and directed.
Dismantling of stone slabs in roofs, suspended floors, chajjas, landings,wall cladding etc., and thickness, jointed in any mortar in any position complete all as specified and directed.
Taking down chowkats or frames with shutters (without taking off shutters from the frames) exceeding 1.5 sqm but not exceeding 4 sqm each and removing from site complete all as specified and directed.
M&L for dubbing out average 10mm thick on irregular face of walls, chajjas, facia etc and mixed with WPC @ 3% wt of cement (when specifically ordered in writing) in CM 1:4 complete all as specified and directed. Note: Wpc shall be paid seperately in respective item.
M&L for 15mm thick rendering in CM (1:4) on stone masonry surfaces to be finished even & smooth without using extra cement complete all as specified and as directed.
M&L for preparation of new plastered or unplastered surfaces of walls and finishing wall with acrylic smooth exterior paint of required shade with two coats applied @ 1.67 Ltr per 10 sqm over and including priming coat of exterior primer applied @ 2.20Kg/10 sqm complete all as specified and directed.
Material & labour for rendering 10 mm thick on concrete surfaces in ceiling in cement mortar 1:4, surface finished even and smoothwithout using extra cement complete all as specified and as directed.
M&L for preparation of new plastered or unplastered surfaces of ceilling and applying three coat of white wash complete all as specified and as directed.
Material & labour for rendering 15 mm thick on stone masonry surfaces of wall in cement mortar 1:6, surface finished even and smooth without using extra cement complete all as specified and as directed.
M&L for preparation of wall surfaces and applying one coat of white cement base wall care putty 2 mm thick on walls finished even and smooth with sand paper and applying two coats of oil bound distemper complete all as specified and directed.
M&L for preparation of old decorated plastered or unplastered surfaces of ceilling by brooming down or steel wire brushing, scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil & greasy spots including cornices etc and applying one coat of white wash over a coat of white putty in patches as required all as specified and as directed.
M&L for complete removal of old existing treatment of wall surfaces and applying one coat of white cement base wall care putty 2 mm thick on walls finished even and smooth with sand paper and applying two coats of bil bound distemper complete all as specified and directed.
Taking down old existing roof treatment(APP membrane) and removing from site complete all as specified and as directed.
Demolition of cement concrete of any type description and in any position and removing debris outside MD land complete all as specified and directed.
M&L for cutting out cracks to V-section in existing roofs or terracing, cleaning out, wetting, grouting with cement and sand slurry 1:3 complete all as specified and directed.
M&L for brushing neat cement slurry with 3 kg of cement per Sqm complete all as specified.
M&L for 40 mm thick cement concrete 1:2:4 type B-0 (using 12.5 mm graded stone aggregate) as in padding, finishing surface of concrete even and smooth without using extra cement complete all as specified and directed.
M&L 10mm thick plastering in CM 1:3 on green concrete roof surfaces with water proofing compound @ 3% by weight of cement, surface finished even and smooth without using extra cement complete all as specified and directed. Note :- WPC shall be measured and paid separately.
Supply only integral water proofing compound ISI Marked.
M&L for providing cement concrete 1:2:4 Type B0 using 12.5 mm graded aggregate in roof kerbs or mud stops, rounded or chamfered on edges complete all as specified and directed.
Material & labour for preparing new surfaces of roof and applying two coats of Polyurethene (PU) acrylic based Water proofing liquid compound over and including a coat of diluted elastomeric self primer and reinforcement fabric sheet as per manufacturer's instruction to stop leakage/seepage from roof/wall complete all as specified and directed.
M&L for taking up or down steel tubing and connection including cleaning for refixing or removal to store yard of bore 15 mm complete all as specified and directed.
M&L for taking up or down steel tubing and connection including cleaning for refixing or removal to store yard of bore 20 mm complete all as specified and directed.
M&L for refixing old steel tubing and connections in new or old position as in walls ceiling floors etc bore of pipe 15 mm complete all as specified and directed.
M&L for refixing old steel tubing and connections in new or old position as in walls ceiling floors etc bore of pipe 20 mm complete all as specified and directed.
Supply & fixing 15 mm bore, medium grade, galvanised iron pipe, with all fittings & fixed complete to walls & ceiling or laid in floor complete all as specified & directed.
Supply & fixing 20 mm bore, medium grade, galvanised iron pipe, with all fittings & fixed complete to walls & ceiling or laid in floor complete all as specified & directed.
Supply & fixing 25 mm bore, medium grade, galvanised iron pipe, with all fittings & fixed complete to walls & ceiling or laid in floor complete all as specified & directed.
M&L for disconnecting existing tanks of capacity 500 ltr to 1000 Ltr, setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position complete all as specified & directed. (Note : Cleaning repairing etc. measured separately).
Supply & fixing in repairs of 15mm bore bib tap, fancy type long body, brass chromium plated complete all as specified and as directed.
Supply and fixing in repairs two way brass chromium plated fancy type bib cock 15mm bore complete all as specified and directed.
Supply and fixing in repairs 15 mm bore fancy type overhead shower with arm, swivel joint chromium plated screwed down of size 300 mm x 300 mm complete all as specified and directed.
Supply and fixing in repairs of brass chromium plated angle stop valves of 15mm bore screwed for 15mm bore iron pipe or union complete all as specified and directed.
Supply and fixing in repairs of PVC connection 15mm size with PTMT nuts of length 450mm complete all as specified and directed.
Supply and fixing in repairs of fancy type pillar taps brass, chromium plated screwed down high pressure with or without lettered Hot or Cold with long screwed shanks & fly nuts for iron pipe of 15mm bore complete all as specified and directed.
Supply and fixing in repairs brass chromium plated handspray (Health faucet) with flexible pipe length not less than 1.00 m (minimum) fixed for EWC/IWC suitable for 15mm bore pipe complete all as specified and directed.
Supply & fixing factory made Solid PVC Door Frame of size 47mm x 50mm made out of 5 mm thick single side prelame PVC sheet & edges shall be painted to match with prelam sheet reinforced with MS square tube complete all as specified & directed.
Supply & fixing factory made solid prelaminted PVC moulded flush Door Shutter, 28 to 30mm thick (stiles), with 2, 4, or 6 raised panel design wood grain both sides complete all as specified & directed.
Supply & fixing stainless steel barrel tower bolt of size 150mm fixed in positions complete all as specified & directed.
Supply & fixing 300 mm long stainless steel sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet complete all as specified and directed.
Supply & fixing 125mm long mild steel butt hinges, cold rolled, medium weight complete all as specified and as directed.
Supply & fixing stainless steel handles of size 125mm, complete all as specified and directed.
Supply & fixing PVC (SWR) pipes 75 mm dia single socketed, in any length with rubber ring joints fixed to walls/laid in floors complete all as specified and directed.
Supply & fixing PVC (SWR) pipes 110 mm dia single socketed, in any length with rubber ring joints fixed to walls/laid in floors complete all as specified and directed.
Supply & fixing PVC (SWR) pipes 200 mm dia single socketed, in any length with rubber ring joints fixed to walls/laid in floors complete all as specified and directed.
Supply & fixing PVC (SWR) pipe bends 75 mm dia provided with access door complete all as specified and directed.
Supply & fixing PVC (SWR) pipe bends 110 mm dia provided with access door complete all as specified and directed.
Supply & fixing PVC (SWR) vent Cowl 110 mm dia complete all as specified and directed.
Supply and fixing in repairs tublar towel rail 20mm dia chromium plated brass of size 60cm long complete all as specified and directed.
Supply and fixing in repairs of brass Chromium plates fancy type soap dish complete all as specified and directed.
Supply and fixing in repairs chromium plated grating of size 100 mm dia complete all as specified and directed.
Dismantling boarding, any description, fixed any position with nails complete all as specified & directed.
S& F 18 mm solid PVC ply of 1st quality of approved colour and fixed with screw, solvent cement/adhessive complete all as specified and directed.
S& F 18 mm solid PVC ply of 1st quality of both side white colour fixed with screw, solvent cement/adhessive complete all as specified and directed.
S&F continuous (piano) hinges, stainless steel, bright finish or electrogalvanised complete all as specified & directed.
S&F magnetic catcher for wardrobe, cub-boards door etc complete all as specified & directed.
S&F stainless steel handles, fabricated type of size 100 mm (ISI Marked) complete all as specified & directed.
Supply & fixing anodised aluminium snap grid frame work of size 600mm x 600mm for false ceiling fixed with screw suspended Hangers 6 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia 40mm long complete all as specified complete all as specified & directed.
S&F 8 mm thick exposed metal frame ceiling with calcium silicate board of siliceous and calcareous material reinforced with cellulose fibre for fixing in 600 x 600mm grid all as specified and directed. (Frame work for ceiling shall be measured and paid separately).
S&F and fabricate aluminium powder coated frame for doors , windows, ventilators, partion wall (thikness of powder coating is 50 micron) with one or more rebates including joining cleat for fixing and fixing screws etc complete all as specified and directed.
S&F aluminium powder coated window and ventilator shutter side hung type without sashbar of any approved colour (thickness of powder coating not less than 50 micron), aluminium sections weighing 0.55kg/m incl necessary joining cleat glazing clips, rubber neoprene packing, alumimium anodised snap beading, screws, peg stay 150mm long -1 No, hinges type B-21 100mm long -2 Nos, suitable handle - 2 Nos in each door, including hinges, aluminium snap beading screws complete all as specified and directed.
S&F 5 mm thick froasted glass panes and glazing with oil putty or fix in aluminium door / window complete all as specified and directed.
S&F stainless steel wire cloth, 0.36 nominal dia of wire and average width of aperture 1.0 mm and fixed with tinned tacks or galvanised wire staples complete all as specified and directed.
M&L for point wiring for one light/fan/ exhaust fan point controlled by one switch using approved colour coding as per IS (Red , Black and Green for single phase circuits), with multistranded copper conductor 1.5 sq mm nominal cross-sectional area, single core, PVC insulated and unsheathed FRLS cable 1100 Volts grade, ISI-694 marked with valid CML No drawn through and including PVC surface conduit of 20 mm bore with accessories in wall floor etc ISI marked, inciuding PVC insulated multistranded copper conductor 1.5 sq mm nominal cross sectional area single core FRLS cable as earth continuity conductor to common earth and connecting to earth dolly, including making good of disturbed surface of cement plaster, whitewash/ distempered match with original colour complete all as specified and directed.
All as per item No 67 above but for One 3 pin 5 amps socket outlet on independent board.
All as per item No 67 above but for one 3 pin 5 amps socket outlet on the same board with other switches.
All as per item No 67 above but with 2.5 Sq mm copper conductor multistraned pvc insulated and unsheathed cable for independent one 3 pin 15 Amps socket outlet and including 2.5 Sq mm PVC insulated copper conductor unsheathed 1100 V grade IS -694 FRLS cable for continuous earth wire complete.
S&F in repairs switch piano 5 amps flush type single pole one way complete all as specified and directed.
S&F in repairs switch piano 16 amps flush type single pole one way complete all as specified and directed.
S&F in repairs socket outlet flush type 3 pin 5 amps complete all as specified and directed.
S&F in repairs socket outlet 2 in 1, 5 pin 16 amps flush type complete all as specified and directed.
Taking down carefully copper/aluminium point wiring light ,fan, socket or power complete, such as switches, ceiling roses, pendents, regulators, sockets etc.removing materials to store for keeping in safe costudy or for taking credit and making good disturbed surface of walls, floors etc. complete all as specified and directed.
M&L for sub main wiring with two runs of 4.0 Sqmm FRLS cable multistranded copper conductors 1100 volt grade IS- 694 marked drawn through and including non metalic PVC surface conduit pipe medium grade ISI marked along with fittings and all accessories on wall/ ceiling surface and including one run of 4.0 sqmm FRLS cable multistranded copper conductors 1100 volt grade IS- 694 as earth continuity conductor complete all as specified and directed. Note : Two runs of main wire and one run of earth wire & one run of non metalic PVC surface conduit pipe shall be measured and paid as one length.
All as per Item No 76 above but 2 run of 6 Sqmm cable and one run of 6 sqmm cable as earth wire.
All as per Item No 76 but 4 run of 6 Sqmm cable and two run of 6 sqmm cable for earth wire.
Taking down old u/s submain wiring any size any make making good disturbed surface of walls, floors etc. complete all as specified and directed.
S&F in repairs MCB 6 to 32 Amps SP, 240 V, 10 KA 'C' curve, IP 20 complete all as specified and directed.
S&F in repairs MCB 40 to 63 Amps SPN, 240 V, C curve 10 KA, IP 20 complete all as specified and directed.
Supply and fixing in repair stepped type electronic fan regulator flush type on the existing phenolic laminated sheet etc suitable for 240 V complete all as specified and directed.
Supply and fixing in repairs ceiling rose, surface type polycarbonate, isolated body 65 mm 3 terminals (ISI marked) complete all as specified and directed.
S&F MCB DB SPN 8 way 240 volt with double door, IP- 43 protection system with having 200 Amps 2 Nos bus bar for neutral bar and earth bus bar fixed/concealed in wall complete and making good disturbed surfaces of wall, floor etc including necessary connection lugging with copper lugs pin/ring type complete all as specified and directed.
S&F MCB DB SPN 12 way 240 volt with double door, IP - 43 protection system with having 200 Amps 2 Nos bus bar for neutral bar and earth bus bar fixed/concealed in wall complete and making good disturbed surfaces of wall, floor etc including necessary connection lugging with copper lugs pin/ring type complete all as specified and directed.
M&L in repairs for earthing complete with galvanised steel earth electrode 60cmx60cmx6mm buried directly in ground vertically to depth not less than 2.25m below normal ground level with top edge of the earth plate at a depth not less than 1.5m below ground level connected to and including GI earth lead wire 4mm dia, by means of nuts, bolts, check nuts and washer etc, made of GI and connected to test point and earth dolly all as shown in electrical plate No. 3 SSR Part-I 2009 and specified or indicated including excavation and earthwork in any type of soil PCC (1:3:6) Type C1 in chamber, precast RCC 50 mm thick in cement concrete (1:2:4) type B1, reinforced with welded steel wire fabric or XPM (Weight not less than 4.00 Kg/Square metre) with cast iron frame, funnel with wire mesh, 20mm bore medium grade GI watering pipe, lugs, 40 mm bore medium grade GI protection pipe, test point etc. complete all as specified and directed. NOTE :- The rate of above Item includes the cost of earth lead and GI protection pipe up to 7.5 Metres. GI earth lead wire 4mm dia beyond 7.5 Metre shall be measured and paid for separately.
Supply and fix in repairs earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 4 mm dia galvanised iron or steel wire complete all as specified and directed.
Supply and fixing in repairs of LED light fitting 1x 20W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed.
Supply and fixing in repairs LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed.
Supply and fixing ceiling fans five star rated with brushless direct current motor (BLDC) complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep Min air delivery 210 CFM with service value 6.00 BEE complete all as specified and directed.
Taking down old u/s ceiling fans of any make any size complete all as specified and directed. Note:- The old U/S ceiling fan shall be deposited to MES store yard by contractor.
Supply & fix fan down rod of size 600mm long made out of 15mm bore duly powder coated GI pipe long complete all as specified and directed.
Supply & fixing exhaust fan metallic type 300 mm sweep 240 V AC single phase complete with aluminium louvers shutters including flexible three core copper conductor cable of 23/0.0076 up to ceiling rose and grounding 04 Nos full threaded bolts and nuts etc all as specified and directed.
Supply & fixing exhaust fan plastic body 250 mm sweep 240 V AC single phase complete with louvers shutters including flexible three core copper conductor cable of 23/0.0076 up to ceiling rose and grounding 04 Nos full threaded bolts and nuts etc all as specified and directed.
Supply and fixing MCB distribution board (ISI marked) TPN, 4 ways, 415 Volts, 50 Hz, AC, double door, vertical type with detachable gland plate, made out of sheet metal phosphatised and painted with epoxy polyster based powder paints, with 200 Amps rated bus bar and earth bar complete all as specified and directed.
Supply and fixing miniature circuit breaker (MCB) 415V TPN 63 Amps 10KA 'C' curve in the DB complete with connection, testing and commissioning complete all as specified and directed.
Supply & fix in repairs building security light luminaire LED 22 W 600K,IP-65 with asthetically designed sheet aluminium housing and UV stabilised acrylic cover complete with lamp and internal connection including bracket made of 40 mm dia GI pipe light grade 1.5 m length fixed with MS clamp of suitable size grouted on wall with suitable nos of screws/bolts/nuts etc complete all as specified and directed.
S&F in replacement single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20 amps 240V complete all as specified and directed.
Taking down TPN/SPN DB any size and any capacity and making good disturbed surface of walls, floors etc. complete all as specified and directed.
Supply, laying and testing cable XLPE Insulated, screened, PVC bedded, galvanized steel strip or wire armoured,electric power cables (heavy duty) 1100Volts grade with stranded aluminium conductor of size 25 sq mm 4 core complete all as specified and directed.
Excavation in trenches in soft/loose soil not exceeding 1.5 m deep and not exceeding 1.5 mtr wide and getting out including forming bottom surface to required levels/ gradients/ slopes for foundations/laying of cable including taking out existing cable and cable protection cover etc. complete all as specified and directed. Note :- Excavation shall be carried out manually all as directed.
Returning filling in including spreading leveling watering and well rammingin layer not exceeding 25 cm in soft/ loose soil complete all as specified and directed.
Removal of excavated material to distance 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point in soil complete all as specified and directed.
Material & labour for sand cushioning for LT cable with tibba sand one layer of 80mm thickness before laying of cable and other layer of 150 mm thickness after laying of cable and punning down to 180mm to provide a required cover complete all as specified and directed by the Engineer-in-Charge. Note- Punned thickness only shall be measured and paid.
Supplying and laying precast concrete cable cover, class LV, Type 2, flat, size 300mm x 180mmx40mm complete all as specified and directed.
S&F out door type LT Feeder Pillar box (Kiosk) of size not less than (L) 60 cm x (W) 45 cm x (H) 45cm made out of 3.0 mm thick CRCA sheet (CPRI approved) with openable Front door including locking arrangement, with and including Copper Busbar 250 amps rating alonwith MCCB 125 Amps 4 pole 16 KA thermal magnetic adjustable type for incoming and panel fixed on angle iron 40x40x6mm frame of suitable size and embedded in PCC plinth 45x45x60mm made of PCC 1:4:8 type D-1 using 40 mm graded stone aggregate complete all as specified and directed.
Material & labour for earthing complete with galvanised steel earth electrode 60cmx60cmx6mm buried directly in ground vertically to depth not less than 2.25m below normal ground level with top edge of the earth plate at a depth not less than 1.5m below ground level connected to and including GI earth strip 32mm x 6 mm, by means of nuts, bolts, check nuts and washer etc, made of GI and connected to test point and earth dolly all as shown in electrical plate No. 3 SSR Part-I 2009 and specified or indicated including excavation and earthwork in any type of soil PCC (1:3:6) Type C1 in chamber, precast RCC 50 mm thick in cement concrete (1:2:4) type B1, reinforced with welded steel wire fabric or XPM (Weight not less than 4.00 Kg/Square metre) with cast iron frame, funnel with wire mesh, 20mm bore medium grade GI watering pipe, lugs, 40 mm bore medium grade GI protection pipe, test point etc. complete all as specified and directed. NOTE :- The rate of above Item includes the cost of earth lead and GI protection pipe up to 7.5 Metres. GI strip beyond 7.5 Metre shall be measured and paid for separately.
S&F galvanised iron pipe 40mm dia light grade with all fittings complete all as specified and directed.
M/S KAUTILYA GARG
VIKAS CONSTRUCTION CO.
MAA CHAMUNDA CONSTRUCTION & SUPPLIER
psj build solutions and company
Savitri Enterprises
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .