| Sl No | Description | Qty | Unit | RKC BUILDERS L3 | K.M.Joy L2 | KURUVILLA KANJIRAKKATTU REJI L1 |
|---|---|---|---|---|---|---|
| 1.00 | Providing and fixing double scaffolding system for all type of works using 40 mm dia M.S. tube 1.5 m centre to centre, horizontal & vertical joining with cup & lock system including necessary working platform etc. and maintaining it in a serviceable condition for the required duration as approved and removing it there after .The scaffolding system shall be stiffened with bracings, runners,connection with the building etc wherever required for inspection of work at required locations with essential safety features for the workmen etc. complete as per directions and approval of Engineer-in-charge (The elevational area of the scaffolding shall be measured for payment purpose .The payment will be made once irrespective of duration of scaffolding). | 400 | M2 | 460 ₹1,84,000 | 300 ₹1,20,000 Lowest | 350 ₹1,40,000 |
| 2.00 | Providing, fabricating & erecting temporary supports to the structural members like beams, slabs etc. to relieve the load on the members during breaking of damaged concrete, removal guiniting, excavation or any dismantling work as per the instruction of engineer incharge/consultant. These supports shall be provided either in the form of props or trestles fabricated using structural steel(with horizontal and inclined mebers as bracing) as per the requirement or by load bearing jackey and as per the instruction of EIC/Consultant. Item rate is inclusive of the materials, all labour, supervision, tools and tackles and transportation & taking away scrap etc., complete as per specification and as directed by EIC : MS props | 10 | NO | 10,000 ₹1,00,000 | 1,000 ₹10,000 Lowest | 5,000 ₹50,000 |
| 3.00 | Chipping & removing old cement plastered surface including racking out joints & clearing the surface for replastering & disposal of the debris as per directions within a distance of 150 m. | 10 | M2 | 460 ₹4,600 | 70 ₹700 Lowest | 780 ₹7,800 |
| 4.00 | Chipping of unsound/weak concrete material from slabs, beams, columns etc. with manual Chisel and/ or by standard power driven percussion type or of approved make including tapering of all edges, making square shoulders of cavities including cleaning the exposed concrete surface and reinforcement with wire brushes etc. and disposal of debris for all lead and lifts all complete as per direction of Engineer- In-Charge-75mm average thickness | 10 | M2 | 900 ₹9,000 Lowest | 1,000 ₹10,000 | 1,200 ₹12,000 |
| 5.00 | Chipping of unsound/weak concrete material from slabs, beams, columns etc. with manual Chisel and/ or by standard power driven percussion type or of approved make including tapering of all edges, making square shoulders of cavities including cleaning the exposed concrete surface and reinforcement with wire brushes etc. and disposal of debris for all lead and lifts all complete as per direction of Engineer- In-Charge-50mm average thickness | 10 | M2 | 1,000 ₹10,000 | 750 ₹7,500 Lowest | 1,100 ₹11,000 |
| 6.00 | Chipping of unsound/weak concrete material from slabs, beams, columns etc. with manual Chisel and/ or by standard power driven percussion type or of approved make including tapering of all edges, making square shoulders of cavities including cleaning the exposed concrete surface and reinforcement with wire brushes etc. and disposal of debris for all lead and lifts all complete as per direction of Engineer- In-Charge-25mm average thickness | 10 | M2 | 1,200 ₹12,000 | 400 ₹4,000 Lowest | 1,000 ₹10,000 |
| 7.00 | Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in charge.In cement mortar. | 3 | M3 | 1,000 ₹3,000 Lowest | 1,000 ₹3,000 Lowest | 1,400 ₹4,200 |
| 8.00 | Demolishing C.C/ R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of engineer - in- charge. | 8 | M3 | 7,000 ₹56,000 | 1,400 ₹11,200 Lowest | 2,100 ₹16,800 |
| 9.00 | Disposal of building rubbish/ malba /similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 1500 m initial lead, for all leads including all lifts involved. | 40 | M3 | 400 ₹16,000 Lowest | 1,000 ₹40,000 | 500 ₹20,000 |
| 10.00 | Dismantling and removing doors with or without ventilators including removal of shutters, hinges, holdfast and all other fittings and stacking materials as per deptl.instructions | 2 | NO | 2,000 ₹4,000 | 250 ₹500 Lowest | 1,500 ₹3,000 |
Tender Value
Refer Docs
EMD Value
₹65,000
Closing Date
5 Aug 2025, 11:00 amClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
AGM(Mat) C
Contracts Dept. Corporate Materials FACT Udyogamandal
Construction of lift well pit in Bagging Plant at FACT (Cochin Division), Ambalamedu, Kochi, as per tender conditions.
2025_FACT_868245_1
04031/2025-2026/E31793
Open Tender
Civil Works
Item Rate
180 days
FACT CD, Ambalamedu
Please refer Tender documents.
7 documents required · 7 mandatory
₹0
₹65,000
Yes
23 Sept 2025
10 Jul 2025
5 Aug 2025
10 Jul 2025
5 Aug 2025
10 Jul 2025
Amount
Providing and fixing double scaffolding system for all type of works using 40 mm dia M.S. tube 1.5 m centre to centre, horizontal & vertical joining with cup & lock system including necessary working platform etc. and maintaining it in a serviceable condition for the required duration as approved and removing it there after .The scaffolding system shall be stiffened with bracings, runners,connection with the building etc wherever required for inspection of work at required locations with essential safety features for the workmen etc. complete as per directions and approval of Engineer-in-charge (The elevational area of the scaffolding shall be measured for payment purpose .The payment will be made once irrespective of duration of scaffolding).
Providing, fabricating & erecting temporary supports to the structural members like beams, slabs etc. to relieve the load on the members during breaking of damaged concrete, removal guiniting, excavation or any dismantling work as per the instruction of engineer incharge/consultant. These supports shall be provided either in the form of props or trestles fabricated using structural steel(with horizontal and inclined mebers as bracing) as per the requirement or by load bearing jackey and as per the instruction of EIC/Consultant. Item rate is inclusive of the materials, all labour, supervision, tools and tackles and transportation & taking away scrap etc., complete as per specification and as directed by EIC : MS props
Chipping & removing old cement plastered surface including racking out joints & clearing the surface for replastering & disposal of the debris as per directions within a distance of 150 m.
Chipping of unsound/weak concrete material from slabs, beams, columns etc. with manual Chisel and/ or by standard power driven percussion type or of approved make including tapering of all edges, making square shoulders of cavities including cleaning the exposed concrete surface and reinforcement with wire brushes etc. and disposal of debris for all lead and lifts all complete as per direction of Engineer- In-Charge-75mm average thickness
Chipping of unsound/weak concrete material from slabs, beams, columns etc. with manual Chisel and/ or by standard power driven percussion type or of approved make including tapering of all edges, making square shoulders of cavities including cleaning the exposed concrete surface and reinforcement with wire brushes etc. and disposal of debris for all lead and lifts all complete as per direction of Engineer- In-Charge-50mm average thickness
Chipping of unsound/weak concrete material from slabs, beams, columns etc. with manual Chisel and/ or by standard power driven percussion type or of approved make including tapering of all edges, making square shoulders of cavities including cleaning the exposed concrete surface and reinforcement with wire brushes etc. and disposal of debris for all lead and lifts all complete as per direction of Engineer- In-Charge-25mm average thickness
Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in charge.In cement mortar.
Demolishing C.C/ R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of engineer - in- charge.
Disposal of building rubbish/ malba /similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 1500 m initial lead, for all leads including all lifts involved.
Dismantling and removing doors with or without ventilators including removal of shutters, hinges, holdfast and all other fittings and stacking materials as per deptl.instructions
Dismantling and removing windows/ventilators/shelves/cup boards/AC frames etc including removal of shutters, hinges, holdfasts and all other fittings and stacking materials as per deptl.instructions
Dismantling the existing structural carefully without damaging the remaining portions including conveying and stacking at places pointed out & removal of debris if any within a lead of 150 m.
Dismantling AC / GI / Tufflite / Aluminium/Zincalum sheet roofing, side cladding etc and depositing the debris away from plant limit within a distance of 150 m.
Anchoring rebar after placing in position and inserting into the holes drilled and grouted using the grout manufactured by HILTI or equivalent make for beams as directed by the engineer-in-charge. Rate shall include supply of all materials (except reinforcement rods), conveyance, all charges for cleaning the surface, ,drilling holes, fixing rebar, grouting etc, at all levels by Hilti authorized personnel (reinforcement rods will be paid in separate item) with- 16mm dia rebar of 273mm development depth using chemical RE-500 V3
Earth work excavation in all classes of soil including narrickal but excluding hard rock which require blasting including back filling in basement & sides of foundation, depositing on bank within an initial lead of 50 m including breaking clods, watering, ramming and sectioning of spoil bank etc.complete- Up to 1.5 m depth from ground level.
Reinforcement Cleaning: Cleaning reinforcement of total rust by tapping or using wire brush or any other suitable way including from behind and around the reinforcement bars to give it a totally rust free finished steel surface.
Rust Removal: Providing and applying approved alkaline chemical rust remover with paint brush and removing loose particles after 24 hours of its application.
Anticorrosive Treatment to Steel: Providing and applying single coat of zinc rich anti corrosive coating such as nitozinc primer in 40 micron thickness to the exposed reinforcing bars after application of alkaline rust remover on main and lateral links all complete as directed by EIC.
Providing and laying in position specified grade of reinforced cement concrete,excluding cost of centering, shuttering, finishing and reinforcement -All work up to plinth level: 1:1.5:3 (l cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources).
Reinforced cement concrete work in walls (any thickness),including attached pilasters, buttresses, plinth and string courses ,filltes, columns,pillars,piers,abutments,posts and struts,etc.,above plinth level up to floor five level,excluding cost of centering, shuttering, finishing and reinforcement - 1:1.5:3 (l cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources).
Steel reinforcement for R.C.C. work including straightening,cutting, bending, placing in position and binding all complete above plinth level.Thermo Mechanically Treated bars of grade Fe-500D or more.
Providing and applying bond coat on the prepared surface toreceive new polymer mortar/polymermodified concrete, with two componentsepoxy based bonding coat Concresive1414 of BASF/Nitobond EP of Fosroc orequivalent material in one full coat.Laying of reinstatement polymer mortaror micro concrete shall be completedwithin the overlay time of bonding coat.This bond coat act as bonding agentbetween old and new concrete. Item rateinclusive of all materials, labours,supervision, tools, tackles, transportation, fixing etc., complete as per specification and as directed.
Providing and laying of polymer modified single component, alkaline resistant fibre reinforced, duel shrinkage-compensated, thixotropic, cementations patch repair mortar Emaco S48CT of BASF/ Renderoc SP 40 of Fosroc or equivalent material that achieves compressive strength of 35 MPa at 7 days and finishing with trowel carefully compacting the same around the rebars and finishing to bring it in line with existing concrete surface on the beams, slabs. pile caps etc., where the thickness of application is less than 50mm in patches as per specification after applying bonding coat (bonding coat shall be payable separately). Item rate inclusive of all materials, labours, supervision, tools, tackles, etc., complete as per specification and as directed. (a) For Built up thickness of 20 mm (incl.+5mm)
Providing and laying of polymer modified single component, alkaline resistant fibre reinforced, duel shrinkage-compensated, thixotropic, cementations patch repair mortar Emaco S48CT of BASF/ Renderoc SP 40 of Fosroc or equivalent material that achieves compressive strength of 35 MPa at 7 days and finishing with trowel carefully compacting the same around the rebars and finishing to bring it in line with existing concrete surface on the beams, slabs. pile caps etc., where the thickness of application is less than 50mm in patches as per specification after applying bonding coat (bonding coat shall be payable separately). Item rate inclusive of all materials, labours, supervision, tools, tackles, etc., complete as per specification and as directed. (b) For Built up thickness up to 40 mm (incl.+5mm)
Providing and Fixing Shear connectors of 10 mm dia. HYSD steel with two component, styrene & cement free, epoxy-acrylate fixing and anchoring compound (having the chnical parameters mentioned in material specifications) using standard sealant applicator gun after drilling holes of 12mm diameter to minimum depth of 100mm at required locations, inclusive of all material, manpower and equipment. MasterFlow 935 of BASF / Lokfix P25 of Fosroc or equivalent.
Centering and shuttering including strutting, propping etc. and removal of form for :Foundations,footings,bases of columns etc for mass concrete.
Centering and shuttering including strutting, propping etc. and removal of form for :Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.
Centering and shuttering including strutting, propping etc. and removal of form for :Suspended floors,roofs,landings balconies and access platform.
Centering and shuttering including strutting, propping etc. and removal of form for :Lintels, beams, plinth beams, girders, bressumers and cantilevers.
Centering and shuttering including strutting, propping etc. and removal of form for :Columns, Pillars, Piers, Abutments, Posts and Struts.
Polymer Modified Micro- Concrete: Providing and laying of polymer modified micro- concrete like Emaco S46 T of BASF/Renderoc RG (S)of Fosroc/ReCon MC 40 of Conmix or equivalent material blended with washed, saturated surface-dry (SSD), graded, low absorption, high density aggregates of size 8 mm & below up to 30% by weight of micro-concrete and water at 4 lit. per 25 kg bag and pouring into the form work using suitable pumping device for uniform flow of concrete. The side shuttering can be removed after 3 days and the bottom shuttering after 7 days ensuring proper bond between the micro concrete and existing concrete substrate. Item rate inclusive of all materials, labours, supervision, tools, tackles, transportation, curing, etc., complete as per specification and as directed.
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in :Cement mortar 1:4 (1 cement : 4 coarse sand).
Cement plastering with CM 1:4,15 mm thick one coat floated hard and trowelled smooth at all levels including cost of cement
Scrapping old paint and Cleaning all surface by Jet Pressure pump of fresh water, removing all fungus, vegetation, Algae & Opening crack by grinder in 'V' shape up to 3mm, cleaning, 1 coat primer & filling all cracks by crack seal, finishing , Cleaning the surround surface etc. as per manufacturer specification.
Painting one coat of priming coat on plastered surface (interior/exterior) with approved quality cement primer after cleaning the surface including all cost of materials, labour etc.
Painting two coats with ready mixed plastic emulsion paint of approved quality and colour specified over the priming coat already done and paid separately after cleaning the surface well.
Painting with one coat of zinc chromate yellow metal primer and two coats of synthetic enamel paint using approved brand & quality at all heights after cleaning the surface including cost of all paint and materials, labour charges etc.complete as per deptl instructions.
Supplying and fixing anodized Aluminium frame work of extruded sections and approved brand / manufacturer including mitering the joints, fixing the frame work with necessary screws, drilling holes in floors/walls, providing plugs for fixing screws, finishing the sides of packing between frame work and walls with plaster of Paris, cost of timber packing if necessary, Rubber lining for air tightness, providing corner cleats etc.complete as per standard practice for glazed Doors, Windows, Partitions, Ventilators etc.including hinges ,pivots, tower bolts, fixtures etc.complete (All Aluminum works including fittings measured in Kg)
Glazing the Aluminium frame work of windows with 3 mm or nearest thick plain glass panes and anodized Aluminium approved brand beadings, with EPDM / NEOPRINE weather seals, gaskets of EPDM or PVC etc and screws as per standard practice at all levels (Measurement for overall area of doors / windows / ventilators)
Glazing/Panelling the Aluminium frame work of doors/other areas with 5.50 mm glass and 4 mm thick hylam sheets (40% hylam sheet aproximate) and powder coated Aluminium approved brand beadings, with EPDM / NEOPRINE weather seals, gaskets of EPDM or PVC etc and screws as per standard practice at all levels (Measurement for overall area of doors/other area)
Providing and laying double charged vitrified floor tiles with approved brand and of size 600x600mm or nearest available size (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622 and fixing floor tiles with cement based high polymer modified quick-set tile adhesive (Water based) conforming to IS: 15477 in average 3 mm thickness and Grouting the joints of flooring tiles having joints of 3 mm width, using epoxy grout mix of 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg), including filling / grouting and finishing complete as per direction of Engineer-in-charge
Supplying, Conveying, fabrication and erection of structural steel work bolted or welded at all levels as per scope drawing for trusses, purlins, louver brackets, louver runners bracings, stair cases, platforms, hand rails ladder, threaded sag rods, splices, etc. with M.S angles, channels, tees, flats, RSJs, rods, pipes and plates including cutting, welding, cleaning, erecting and painting with two coats of zinc chromate primer (one shop coat and one coat after erection) and two coats of chemical resistant enamel paint of approved quality and colour over the primer including supply of necessary MS bolts and nuts other than holding down bolts.(The structural steel material shall be of M/s. SAIL / RINL / TISCO /JINDAL make) - Required gas and electrodes will be supplied free of cost by FACT at stores
Providing non-asbestos high impact Polypropylene reinforced cement, 5.50 mm minimum thick, corrugated sheets (as per IS: 14871) of suitable colour as approved by Engineer-in-charge, roofing up to any pitch and fixing with polymer coated J, or L hooks, bolts and nuts 8 mm dia. G.I. plain and bitumen washers or with self drilling fastener and EPDM washers etc. complete (excluding the cost of purlins, rafters and trusses), including cutting sheets to size and shape wherever required
Providing corrugated serrated adjustble ridges or hips in Non- asbestos fibre cement high impact polypropylene reinforced roofing with suitable fixing accessories or self drilling fastener and EPDM washer , etc. complete as per instructions.
Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion at all levels.110mm diameter pipe.
Supplying. Conveying, fabricating and fixing MS inserts plate, angle inserts, MS inserts of all types fabricated out of MS plates, angles, channels, flats, rods, fabricated pieces, etc. embedding in RCC/ masonry works at all levels including all charges for cutting, welding of lugs, fixing to lines and levels and hot dip galvanized conforming to IS 4759 and further coated with one coat of yellow zinc chromate primer and two coats of anticorrosive bitumen black paint etc complete as directed by the Engineer-in-Charge
Waterproofing of Roof :- (Elastomeric Water proofing) i) Surface preparation by suitable means to remove laitance, loose particles, debris,weather prrof course etc. ii) All pipe penetration shall be sealed with polymer modified mortar (PMM). iii) Necessary coving the corners of walls, bore packing with SBR latex mortar, any cracks treatment with low viscous epoxy injection resin on places wherever required. iv) Saturate the surface with clean water before application of waterproof coating system. Once water get dried off apply two coats of highly acrylic elastomeric waterproof coating system on to the entire surface and allow to cure by itself. Rate of application of acrylic elastomeric waterproof coating system shall be as per manufacturer specification.
Protect the waterproofing membrane coating with protective concrete screed (1:1.5:3) of average 50mm thick made to proper slope for water outway and compacting using power floating machine as per direction of EiC. The rate shall be inclusive of labour, machinery and material.
Providing and placing in position suitable PVC water stops confirming to IS:12000 for construction /Expansion joints between two RCC members and fixed to the reinforcement with binding wire before pouring concrete etc., complete:Dumb bell with central bulb (180mm wide,8mm thick).
K.M.Joy (BID ID -3258612)
RKC BUILDERS (BID ID -3258545)
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .