Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.0 LAccepted-Finance N A | L1 | Accepted-Finance Ok | |
| 2 | L2₹5.2 L+₹17,500 (3.51%)Accepted-Finance 142 B GROUND FLOOR PATPARGANJ NEAR MAYUR VIHAR PHASE 1 DELHI 91 | EAST | DELHI | 110091 | L2 | Accepted-Finance Ok |
Tender Value
Refer Docs
EMD Value
₹10,000
Closing Date
30 Jul 2020, 3:00 pmClosed
Assistant Engineer Elect
AE(E) HC1 HMED(C) PWD LN Hospital New Delhi
Rectification of Addressable Fire Alarm System at B- Block, GIPMER Bosch Make
2020_PWD_192957_1
NIQ 1(21)/AEE/HC1/PWD/HMEDC 2020-21/222
Open Tender
Miscellaneous Works
Works
7 days
Work
Please refer Tender documents.
7 documents required · 7 mandatory
₹0
₹10,000
Yes
31 Jul 2020
23 Jul 2020
30 Jul 2020
23 Jul 2020
30 Jul 2020
23 Jul 2020
Amount
Rectification, Testing, commissioning and Re-Programming of Loops in existing Addressable Fire Alarm System complete as required
Supply, Installation, testing and commissioning of MPC- 1300-C Controller, TFT touch ‑ screen (320 x 240 px) with automatically activated backlight. 12 LEDs provide continuous information about the operating status of the control panel and / or system. Controller can be used to visually display alarms or faults i/c programming the existing fire alarm system complete as required (Make:- Bosch)
Supply, Dismantled, fixing, Testing and Commissioning of Addressable Multi sensor Detector with a combination of Optical and Thermal, including mounting base with LED… etc. complete as required, Each Detector should have Isolators for maintaining operational availability of all elements in the loop, even in the event of a short circuit & Drift Compensation feature & Automatic addressing. shall be EN54/ VDs/UL certification, (Make- Bosch)
Supply, Dismantling, fixing, Testing and Commissioning of Addressable Manual Break Glass/ flap Unit (Double action) with flexible network structures & necessary fixing arrangements with key complete as required shall be EN54/ VDS certification, (Make- Bosch)
Supplying & laying of 2x1.5 sqmm fire alarm armoured cable, 600/1000V rated with annealed copper conductor having XLPE insulation, steel wire armouring & FRLS outer sheath complete as required. (Make:- Polycab, Hevels, Kalinga)
R K Fire Safety Devices
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .