Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹17.2 LAccepted-AOC 98 99 JARNALLY KOTHI KARNAL HARYANA 132001 | KARNAL | KARNAL | HARYANA | 132001 | L1 | Accepted-AOC AOC | |
| 2 | L2₹18.3 L+₹1.2 L (6.84%)Rejected-Finance 00 LALPUR KICHHA ROAD RUDRAPUR KICHHA RUDRAPUR UDHAM SINGH NAGAR UTTARAKHAND 263148 | UDAM SINGH NAGAR | UTTARAKHAND | 263148 | L2 | Rejected-Finance Highest | |
| 3 | L3₹18.8 L+₹1.7 L (9.81%)Rejected-Finance | L3 | Rejected-Finance Highest | |
| 4 | L4₹19.4 L+₹2.2 L (13.0%)Rejected-Finance SCF 15 HUDA COMPLEX 184 NEW IDC 124001 | ROHTAK | HARYANA | 124001 | L4 | Rejected-Finance Highest | |
| 5 | Rejected-Technical | - | Rejected-Technical Rejected |
Tender Value
₹24.5 L
EMD Value
₹48,980
Closing Date
21 Feb 2022, 5:00 pmClosed
Ritesh Nandal
Executive Engineer, Elect. Divn. PWD B and R Br. Ambala Cantt.
Const. of Mukund Lal Civil Hospital at Yamuna Nagar. (Pdg. EI Estate).
2022_HRY_206380_1
PWD/Elect-KNL/Elect-AMB/110228
Open Tender
Construction Works
Works
120 days
Ambala Cantt.
Please refer Tender documents.
3 documents required · 3 mandatory
₹1,000
₹48,980
Yes
22 Apr 2022
7 Feb 2022
22 Feb 2022
7 Feb 2022
21 Feb 2022
7 Feb 2022
Amount
Wiring main ,sub mains and Circuit wiring in two single core for phase and neutral wire and one single core for earth wire PVC insulated Copper conductor cable 1100 Volts grade in MS Conduit etc as required. 1 run of Size 1.50 Sqmm(1/1.40mm) HSR No. 23.1.6.1
MCCB Enclosure made of Sheet Steel suitable for mounting MCCB of following ratings MCCB up to 125 A FP HSR No. 23.22.2.1
MCCB ,DISTRIBUTION BOARDS, MCB's, RCCB's, CHANGE OVER etc. Supply and erection of Modular case circuit breaker single pole/4 pole on existing wall/pedestal/Panel including bounding to earth and making necessary connections required to complete the job in all respect up to the entire satisfaction of the Engineer-in-charge of the work. TRIPLE POLE MCCB 16 to 100 amp, 25 KA HSR No. 23.22.1.3
Supply and erection of double door sheet steel enclosure distribution board suitable for MCBS and ELCBS etc. recessed in wall including bonding to earth with all labour and material required to complete the job in all respect up to to the entire satisfaction of the Engineer-in-Charge of the work. Vertical TPN DB Double Door 4 way ( 8 incoming and 3phase*4 outgoing) HSR No. 23.22.4.9
Supply and erection of miniature circuit Breaker/isolator 240/415 V in the existing distribution board including making necessary connections:- 6 amp. to 32 amp Single Pole HSR No. 23.22.5.1
Supply and election of Goodridge Almirante type MS pedestal made of 50 mm *50 mm * 6 mm angle Iron frame with 3.00 mm thick M.S. sheet covering including shutters with suitable hinges and looking arrangement with the Godrich type handle including round bars. The to covering should have a downward overhang of 75 mm on all sides of pedestal, having two sets of water proof ventilation holes of suitable size on the sides, at top and bottom, each set containing four No’s. holes to discharge the heat produced by suitable size to make it water proof . The pedestal duly painted both inside and outside with two coats of approved paint and primary coat and its legs are embedded upto the entire depth in 1:2:4 cement concrete block, projected 75 mm all around the pedestal and 200 mm above the ground level including the cost of all labour and material required to complete the job in all respect upto the entire satisfaction of the Engineer-in charge of the work. M.S. pedestal of size 750 mm wide, 1200 mm high, 300 mm deep and bottom totally open , duly embedded in cement concrete block of size 900 mm*450 mm*200 mm above ground level , having a base of size 1050 mm* 600 mm* 250 mm below ground level. HSR No. 23.27.3
EARTHING AND LIGHTENING ARRESTOR Earthing with GL earth pipe 4.5 m long and 40 mm dia with masonry enclosures on the top etc. (but without charcoalor coke and salt) as required. HSR No. 24.1.1
Extra for using salt and char coal/coke for pipe earth electrode as required. HSR No. 24.1.2
Providing and laying earth connections from earth electrode with 4.00 mm dia G.I. wire in 15 mm dia G.I. pipe from earth electrode as required. HSR No. 24.1.11
Supply, installation, testing and commissioning of 12.5 mtr. long High Mast manufactured from B.S.E.N. 10025 or equivalent grade material in, 2 (two) section hot dip , galvanized inside and outside in single dip, suitable for wind velocity as per IS 875 Part-3 suitable for 6 no’s. luminarie loading fully motorized (power tool) with starter & cable complete along with standard accessories supplied by the manufacturer with 3 no’s steel wire rope double drum system and twin dome aviation light with LED without foundation but including cost of set of foundation nut and bolts, installation at site complete I all respect upto entire satisfaction of Engineer-in Charge.Thickness of Top and Bottom Section = 3 mm (minimum ) Top Dia = 150 mm and Bottom Dia = 360 mm. Thickness of Galvanization - Top = 65 micron (minimum) and Bottom = 85 micron (minimum) HSR No. 24.4.15.1
S/E mark double walled corrugated (DWC) HDPE, pipe 10 Kg/Cm2 ,laid 0.75 Mtr below ground level including diging and refilling of earth including cost of suitable size socket/cuppler for HDPE pipe including the cost of labour and material required to complete the job in all respect up to the entire satisfaction of Engineer in charge of the work. DWC/HDPE pipe 63/50 mm outer dia/inner dia HSR No. 24.5.2.3
DWC/HDPE pipe 90/75 mm outer dia/inner dia HSR No. 24.5.2.4
RCC FOUNDATIONS FOR HIGH MAST OCTAGONAL POLES Providing RCC foundation of M25 grade (1 Cement:1 Stone aggregate: 2 Coarse sand) i/c excavation, steel reinforcement (Fe 500) @ 75 kg/cum of concrete contents, concrete cover 50mm, anchor bolts etc. over a bed of PCC 1:5:10 of required dimensions for high mast octagonal poles of various heights as per following specifications complete in all respects and as per directions of Engineer-in-charge 12.5 m high mast pole HSR No. 24.9.1
Supply of LED Flood Light 200W IP 65 as per approved make with all labour and material required to complete the job in all respect up to the entire satisfaction of Engineer-in-Charge of work. NS-1
Supply of LED Flood Light 240W IP 65 as per approved make with all labour and material required to complete the job in all respect up to the entire satisfaction of Engineer-in-Charge of work. NS-2
Supply of 0.3 KVA capacity inverter with SMF battery for aviation light in existing panel i/c the cost of labour charges and connections and petty material etc. for complete in all respect upto the entire satisfaction of the engineer-in-charge of work. as per approved make. NS-3
Supply of Gate Light Globe 40W 5700 K as per approved make list, Post Top and including necessary connection with all labour and material required to complete the job in all respect up to the entire satisfaction of Engineer-in-Charge of work. NS-4
Supply of 65 amp. 3 Pole/230V Astronomical automatic time switch as per approved make list complete in all respect upto the entire satisfaction of Engineer-in-charge of the work. NS-5
Supply and erection of under ground cable 1 metre below ground level covered with sand and bricks including necessary connections, digging and refiling of trenches. Supply of 16 Sqmm 2Core Cable, with all labour & material required to complete the job in all respect upto the entire satisfaction of Engineer in Charge of work. NS-6 (i)
Supply of 25 Sqmm 4Core Cable, with all labour & material required to complete the job in all respect upto the entire satisfaction of Engineer in Charge of work. NS-6 (ii)
S R Enterprises
M/S PANJETA ELECTRICALS
Highlight Associates and Contractors
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .