Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Rejected-Technical | Rejected-Technical Not Qualified |
Tender Value
₹1.8 L
EMD Value
₹3,600
Closing Date
12 Apr 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Director
NIT, Calicut, Kerala - 673601
Providing plug points and modification of lightning at Seminar hall II, PG Block EED
2021_NITC_622976_1
EMU1/Electrical /2020-21
Open Tender
Electrical Works
Item Rate
20 days
Calicut
Please refer Tender documents.
8 documents required · 8 mandatory
₹590
Director, NITC
₹3,600
Yes
28 Jun 2021
18 Mar 2021
14 Apr 2021
18 Mar 2021
12 Apr 2021
18 Mar 2021
90 days
Amount
Wiring for light / fan points with 1.5 sq mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class ivory coloured PVC conduit with modular switch, modular plate, suitable G. I box earthing the point with 1.5 sq mm green coloured FRLS PVC insulatd copper conductor single core cable etc, as required. (Group C)
Supplying and fixing of 20 mm (medium class) ivory coloured rigid PVC conduit along with accessories in surface / recess including cutting the wall and making good the same in case of recessed conduit as required.
Supplying and drawing 3 numbers 1.5 sq mm FRLS PVC insulated copper conductor single core cable (Red, Black & Green) in existing surface / recessed PVC conduit as required.
Supplying and drawing 3 numbers 2.5 sq mm FRLS PVC insulated copper conductor single core cable (Red, Black & Green) in existing surface / recessed PVC conduit as required.
Supplying and fixing 5/6 A modular switch on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
Supplying and fixing 3 pin 5/6 A modular socket (Universal) outlet on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
Supplying and fixing 1 or 2 Module, GI box alongwith modular base & cover plate for modular switches in recess etc. as required.
Supplying and fixing 3 Module, GI box alongwith modular base & cover plate for modular switches in recess etc. as required.
Supplying and fixing 6 Module, GI box alongwith modular base & cover plate for modular switches in recess etc. as required.
Supplying and fixing 12 Module, GI box alongwith modular base & cover plate for modular switches in recess etc. as required.
Supply and fixing of recessed mounting type down light 28 W (128 lum/watt), cool white 4x1 LED luminaire with white flat light opal diffuser with white powder coated CRCA sheet steel/aluminium housing with LEDs complete with all accessories etc, as required.
Supply and fixing of recessed mounting type down light 10 W (100 lum/watt), cool white 152mm x152mm LED luminaire with white flat light opal diffuser with white powder coated CRCA sheet steel/aluminium housing with LEDs complete with all accessories etc, as required.
Supplying and fixing 5-32A rating, 415 V, 'C' curve miniature circuit breaker suitable for inductive load of Single pole in the existing MCB DB, complete with connections, testing and commissioning etc. as required.
Supplying and fixing 25 A rating, 415 V, 'C' curve miniature circuit breaker suitable for inductive load of Single pole and neutral in the existing metal enclosure, DB complete with connections, testing and commissioning etc. as required.
Supplying and fixing 25 A rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Supplying and fixing 12 way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
Charges for removing the existing wiring with switch boards, DB and light/fan fittings and conveyance of the materials to the godown etc as required.
Supply and fixing of recess mounting type 4W LED foot light as required.
Supplying and fixing 8/10mm "S" type steel fan hook and making good the damages with giving connection as required.
Installation, testing and commissioning of ceiling fan, including wiring the down rods of length (upto 90 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required.
Supplying and fixing extra down rod of 10 cm length G.I. pipe,15mm dia, heavy gauge including giving connection with 0.5 sq.mm 3 core round flexible copper wire and painting the down rod etc. as required.
Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .