Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹77.0 LAdmitted-Finance T10 3RD FLOOR RAYHILSORT RESIDENCY DR PICKLE ROAD UTTARA KANNADA KARNATAKA 581301 UDYAM GA 02 0002041 27AAJCM4307Q1ZY B 29AAJCM4307Q1ZU R | UTTARA KANNADA | KARNATAKA | 581301 | ₹77.0 L | L1 | Admitted-Finance |
| 2 | Rejected-Technical | - | - | Rejected-Technical TECHNICALLY DISQUALIFIED |
| 3 | Rejected-Technical PLOT NO 195 QUAY STREET OPP NAGINA HOTEL DARUKHANA REAY ROAD EAST MUMBAI MAHARASHTRA 400010 | MUMBAI SUBURBAN | MAHARASHTRA | 400010 | - | - | Rejected-Technical TECHNICALLY DISQUALIFIED |
| Sl No | Description | Qty | Unit | Mercury Ship Repairs Pvt Ltd L1 |
|---|---|---|---|---|
| 1.01 | Defect rectification and operationalisation of FIFI external firefighting system. Following works to be undertaken on the FIFI system:-
(i) Serviceability checks of FIFI system to be undertaken including rectification of all defects. Trail to be undertaken and system performance to be proved.
(ii) Stbd FIFI clutch lub oil cooler to be cleaned and pressure test to be carried out.
(iii) Renewal of actuator nozzle of FIFI system on top of bridge. Qty- 02
(iv) FIFI clutch not engaging in remote mode defect to be rectified.
(v) Undertake checks of control of starter penal at bridge and engine room and rectification of all defects and defective components
(vi) All lub oil filters to be renewed.
(vii) Lub oil leakage from system pipe to be rectified.
(viii) Undertake inspection of gear box and top-up of oil.
(ix) Undertake alarms and safety checks.
(x) Renewal of remote monitor cable along with rotary switch. | 1 | Job | 59,00,000 ₹59,00,000 Lowest |
| 1.02 | Complete overhauling of FIFI pumps | 1 | Nos | 95,000 ₹95,000 Lowest |
| 1.03 | Renewal of FIFI clutch lub oil flexible hose and pressure gauges at suction and discharge side of pump as per sample. | 2 | Nos | 18,000 ₹36,000 Lowest |
| 1.04 | Renewal of FIFI discharge flexible hose along with coupling as per sample on deck. | 8 | Nos | 65,000 ₹5,20,000 Lowest |
| 1.05 | Valve :- removal overhauling pressure testing and fitment of following valves:-
(i) 250 NB | 4 | Nos | 15,000 ₹60,000 Lowest |
| 1.06 | (ii) 150 NB | 8 | Nos | 9,000 ₹72,000 Lowest |
| 1.07 | (iii) 80 NB | 2 | Nos | 8,000 ₹16,000 Lowest |
| 1.08 | (iv) 50 NB | 3 | Nos | 6,500 ₹19,500 Lowest |
| 1.09 | Renewal of operating wheels of fifisystem valve | 10 | Nos | 1,800 ₹18,000 Lowest |
| 1.10 | Renewal and pressure testing and fitment of following pipes:-
(i) 350 NB | 40 | MTR | 11,000 ₹4,40,000 Lowest |
Tender Value
Refer Docs
EMD Value
₹2.7 L
Closing Date
10 Aug 2023, 11:00 amClosed
The Admiral Superintendent
Naval Ship Repair Yard Naval Base Karwar 581308
UNDERTAKING DI/DR ON STBD FIFI AT NSRY (KAR)
2023_NAVY_610078_1
YCM-22-TEZ-STBD-FIFI
Open Tender
Marine Services
Item Rate
180 days
NAVAL SHIP REPAIR YARD
Please refer Tender documents.
4 documents required · 4 mandatory
₹0
₹2.7 L
Yes
YCM DEPT
6 Mar 2024
21 Jul 2023
11 Aug 2023
21 Jul 2023
10 Aug 2023
22 Jul 2023
28 Jul 2023
Amount
Defect rectification and operationalisation of FIFI external firefighting system. Following works to be undertaken on the FIFI system:- (i) Serviceability checks of FIFI system to be undertaken including rectification of all defects. Trail to be undertaken and system performance to be proved. (ii) Stbd FIFI clutch lub oil cooler to be cleaned and pressure test to be carried out. (iii) Renewal of actuator nozzle of FIFI system on top of bridge. Qty- 02 (iv) FIFI clutch not engaging in remote mode defect to be rectified. (v) Undertake checks of control of starter penal at bridge and engine room and rectification of all defects and defective components (vi) All lub oil filters to be renewed. (vii) Lub oil leakage from system pipe to be rectified. (viii) Undertake inspection of gear box and top-up of oil. (ix) Undertake alarms and safety checks. (x) Renewal of remote monitor cable along with rotary switch.
Complete overhauling of FIFI pumps
Renewal of FIFI clutch lub oil flexible hose and pressure gauges at suction and discharge side of pump as per sample.
Renewal of FIFI discharge flexible hose along with coupling as per sample on deck.
Valve :- removal overhauling pressure testing and fitment of following valves:- (i) 250 NB
(iii) 80 NB
Renewal of operating wheels of fifisystem valve
Renewal and pressure testing and fitment of following pipes:- (i) 350 NB
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .