Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CHIEF OFFICER
CO JMC
Providing Water Work Material and Maintanance for Junnar Municipal Council, Junnar
2021_DMA_668275_3
E- Tender No. 07 2020-21 for JMC Junnar Water Dept
Open Tender
Miscellaneous Services
Item Rate
365 days
J M C
Please refer Tender documents.
2 documents required · 2 mandatory
₹1,000
₹5,000
30 Apr 2021
6 Apr 2021
19 Apr 2021
6 Apr 2021
17 Apr 2021
6 Apr 2021
120 days
Amount
MATERIAL
Supply of C.I.Mechenical compression collar coupling (popularly known as Jifty TM Collar Coupling ) Suitable for C.I. Sun Pipes (as per IS -1536 /2001) & D.I. Pipes (as per IS -8329 /2000), complete with sealing rubber gasket of S.B.R. C.I. follower glans and M.S. nut bolts. The whole assembly should be mechanically and hydraulically tested to the provisions as laid down in IS-1538/1993
MJP DSR 2018-19 P. No. 260, I. No. 2
Supply of C.I.Mechenical compression flanged / Socket Tail Piece (Populalrly known as I™ Flanged / socket Tail Piece) Suitable for making flanged connecting with the plain barrel of C.I. spun pipes (as per IS - 1536 /2000), The tail Piece complete with sealingrubber gasket of S.B.R.,C.I. follower glands and M.S. nut bolts .
MJP DSR 2018-19 P. No. 260 I. No. 1
Supply of C.I. Mechanical joint all socket, Tees as dimensionally described in tube -18 of 13382/1992 complete with sealing rubber gasket,of SBR with cast iron follower gland & mild steel nut bolts coated or otherwise protected from & suitable for CI pipes
MJP DSR 2018-19 P. No. 264 ,I.No.7
Supply of C.I. Mechanical joint double socket with flanged tee as dimensionally described in tube -18 of 13382/1992 complete with sealing rubber gasket,of SBR with cast iron follower gland & mild steel nut bolts coated or otherwise protected from & suitable for CI pipes
MJP DSR 2018-19 P. No. 264 ,I.No.8
Supply of C.I. Mechanical Joint Double socket 90 (1/4) Bends as dimensionaaly Described in Table -14 of IS -13382/1992 complete with sealing rubber gasket (dimensionally described in IS -12820/ 1989 ) with cast iron following gland & mild steel nut bolts coated or otherwise protected from rustin & suitable for CI pipes
MJP DSR 2018-19 P. No. 261 ,I.No.3
Supply of C.I. Mechanical Joint Double socket 90 (1/4) reducer as Described in Table -21 of IS -13382/1992 complete with sealing rubber gasket (dimensionally described in IS -12820/ 1989 ) with cast iron following gland & mild steel nut bolts coated or otherwise protected from rustin & suitable for CI pipes
150x100mm dia
200x100mm dia
200x150mm dia
300x150mm dia
MJP DSR 2018-19 P. No. 267 ,I.No.9
Providing double flange sluice valve conforming to IS-2906/14846 including work gear arrengements as per test pressure, stainless steel, spindle , caps,excluding GST leived by GOI & GOM in all respect
c) sluice valve -PN-1.6 (without by pass)
MJP DSR 2018-19 P. No. 236 ,I.No.2
Providing and supplying ISI marked D.I.S.& S pipes (push on joints pressures pipes of D.I. of following class and diameters conforming to the cost of jointing materials (rubber gasket of EPDM quality ) excluding all staturoty duties and taxes levied by Govt. of India and Govt. of Mahrashtra in all respect education cess, VAT third party inspection charges of TPI agency approved by MJP, including tranist insurance ,railway freight , unloading ,stacking , etc. complete , as directed by engineer -in -charge .(IS- 1536/2001 for pipes and IS 12820/1989 or latest edition revision with amendments for rubber gaskets)(IS 18329-2000 latest version )
MJP DSR 2018-19 P.No.86, I. No. 3
Providing and supplying ISI Mark rubber gasket suitable for C.I.or D.I.Pipes of all class for tyton joints including ,inspection charges, transporation to departmantel stores /site etc. excluiding leived by GOI & GOM in all respect complete
MJP DSR 2018-19 P. No. 254 .I. No. 21 (A)
Welding in all position with required number of runs, for M.S. pipe internally and /or externally including gauging Wherever necessary fixing ,appurtenance & other accessories in connection with pipe laying work as per specification .
MJP DSR 2018-19 P, No. 211,I.No.7(A) add 10%for H.A.
Supplying Brass, gunmetal material for spindle & check
Check Nut
Check Nut
Check Nut
Check Nut
Check Nut
Check Nut
Check Nut
Check Nut
Check Nut
Gland Russi for Sluice valve
6mm to 20mm
MATERIAL
Providing of ISI Mark G.I. pipes of following class & dia, excluding all local & central taxes octrol inspectipon charges ,transportation to stores etc . Complete .(ISI 1239/ 2004) Note-one coupler should be prvidedwith each full length pipe,cost of which is included in rates below
15mm (without E.D)
MJP DSR 2018-19 P. No. 110, I. No. 1(B)
G.I. Bend "B" class
(MJP mechanical CSR -2018-19 P. No. -14 code No-PW 1)
G. I. Tee "B" Class
(MJP mechanical CSR -2018-19 P. No. -14 code No-PW 2)
G.I. Coupling /Nipple "B" Class
(MJP mechanical CSR -2018-19 P. No.14 code No-PW 3)
G.I. Union (Heavy Duty )
(MJP mechanical CSR -2018-19 P. No-15 code No -PW 4)
M.S.Flanges
(MJP mechanical CSR -2018-19 P.No-16 code No -PW 10)
UP to 300 NB
Above 300 NB
NUT- BOLTS DSR pune PWD 16-17
LABOUR
Excavation for foundation / pipe trenches in earth, soil of all types sand ,gravel & soft murrum including removing the execavated material upto a distance of 50 meters & lifts as below, stacking &spreading as directed , normal dewatering ,preparing the bed for foundation & excluding backfilling etc complete
MJP DSR 2018-19 P. No. 47, I. No. 1 add 10% for H.A
Excavation for foundation / pipe trenches in Hard murum & boulders,WBM road including t removing the execavated material upto a distance of 50 meters beyond the area & lifts as below , stacking & spreading as directed , normal dewatering , prepairing the bed for foundation & excluding backfilling.
MJP DSR 2018-19 P. No. 47, I. No. 2 add 10% for H.A. & 2% for municipal area
Excavation for foundation /Pipe trenches in soft rock & old cement &lime masonary foundation asphalt road including remoing the excavated materials upto a distance of 50 meter & lifts as below , stacking &spreading as directed normal dewatering , prepairing the bed for foundation & excluding backfilling
MJP DSR 2018-19 P. No. 47 ,I.No. 5 add 10% for H.A.
Excavation for foundation / pipe trenches in Hard rock & concrete road by chiseling, welding, line drying by mechanical means or by all means other than blasting including & leveling the bed, removing the excavated materials upto a distance of 50 meter & lifts as below , stacking & spreading as directed , normal dewatering , preparing the bed for foundation & & excluding backfilling
MJP DSR 2108-19 P. No. 48 ,I. No. 7 add 10% for H.A.
Refiling the trenches with available excavated stuff with soft material first over pipeline & then hard material in 15 cm layers with all leads & lifts including consolidation , surcharging complete
MJP DSR 2018-19 P. No. 50, I. No. 15 add 10%for H.A.
Making cross connection to exiting distribution main of any type including excavation breaking & removing existing pipes, lowering , laying , of specials &pipes in their position ,refiling , closing the water supply in that area, dewatering & restarting the water supply etc. complete as directed by Engineer In Charge for following diameter of existing pipeline, irrespective of diameter of branch line . (the number of joints involved will be paid seperately depending upon the nature of)
MJP DSR 2018-19 P. No. 73 add 10% for H.A.
Dewatering the excavated trenches and pools of water in the building trenches / Pipeline trenches well works by using pump and other device including disposing off water to safe distance as directed by engineer - In -charge (Including cost of
MJP DSR 2018-19 P. No. 52 ,I. No. 14 add 10% for H.A.& 2% for municipal area
Lowering laying and jointing with SBR rubber gasket C.I. / D. I. SS Pipes of various classes with C.I. /D.I. MS specials of following diameter in proper position , grade and aligments as directed by Engineer-In-charge including conveyance of material from store to site of work , including cost of jointing material and rubber rings labour etc complete
MJP DSR 2018-19 P.No. 84, I . No. 2(A) add 10% for H.A.
Lowering laying and jointing In position following C.I. D /F Reflux valves, Buttrefly valves and sluice valves incluiding all labour jonting material,incluiding nut bolts and giving satisfactory hydraulic testing etc. complete (Rate for all class and valves)
MJP DSR 2018-19 P. No. 240 ,I. No. 4 add 10%
Providing and constructing B.B. masnory valve chamber with 15 cm thick 1:3:6 proportion PCC bedding excluding excavation , B.B. Masnory in CM 1:5 proportion precast RCC frame and cover etc. complete as directed by Engineer-In- charge .As above of 90 x 45 cm internal size depth upto 1.2 M with pre cast RCC slab cover
MJP DSR 2018-19 P.No. 385 ,I. No. 1(8) add 10% for H.A.
Providing and laying in situ cement concrete M -15 of trap/ granite /quartzite / gneiss metal for foundation and bedding including boiling out water , from work compaction,
MJP DSR 2016 -17 P. No.43 ,I. No. 1(b) add 10% for H.A. MJP DSR 2018-19 P.No. 385 ,I. No. 1(8) add 10% for H.A.
Dismantling dead pipeline G.I. /A. C. /P.V.C. /S. W./H. D. P. E. pipe including cost of necessary excavation and refiling of trenches, breaking the joints ,lifting the pipes and stacking to the place as directed by Engineer - In - charge with all leads and lifts incluiding ceaning the area etc complete
For M.S. /R.C.C./C.I. /P.S.C.
MJP DSR 2018-19 P. No.74 ,I. No. 11(A) add 10% for H.A.
For G. I./A. C. /P.V.C. /S.W./H.D.P.E.
MJP DSR 2018-19 P. No. 11 (B) add 10% for H.A.
Lowering laying and jointing G.I. pipes and specials of following class and diameter including conveyance from stores to site of works .All labour , giving satisfactory hydraulic test , etc. complete .Either underground or in vertical position as directed by engineer in-charge
MJP DSR 2018-19 P. No. 113 ,I. No. 2 (B) add 10% for H.A.
Providing & suppling ISI mark CI D/F reflux valve (non eturn valve)of following dia.incluiding railway freight inspection charges,unloading from railway wagon,loading into truck transportation charges upto departemental stores unloading stacking excluiding GST leived by GOI & GOM in all respect etc complete Reflux valve as per I.S.5312 part I(1984)
c) sluice valve -PN-1.6 (without by pass)
Providing & suppling Air Valves as per IS-14845 and MJP std specifications double orifice type combined with screw down isolating valve,small orifice elastic ball resting on a gun metal orifice nipple,large orifice vulcanite ball seating on moulded seat ring,inlet face and drilled,incluiding insurance,loading,unloading,transportation upto departmental stores,excluiding GST leived by GOI & GOM in all respect etc complete
b) Air valve Double Ball flanged -PN-1.6
MJP DSR 2018-19 P. No. 243 ,I. No. 6 (B)
Lowering,laying & fixing in proper alignment an position all typs of C.I.air valves as directed by Engineer-in-charge incluiding cost of conveyance from stores to site of work,cost of all material and giving satisfactory hydraulic testing etc complete (for all class of valves)
b) Air valve Double Ball (PN-1 & PN-1.6)
MJP DSR 2018-19 P. No. 247 ,I. No. 10 (B)
Fairwell 1/2"
Fairwell 1"
Solvent(greese)
1"UPVC Pipe
0.5"UPVC Pipe
2"UPVC Pipe
1"UPVC socket
0.5"UPVC socket
2"UPVC socket
1"UPVC Brass elbow
0.5"UPVC Brass Elbow
1"UPVC Brass F.T.A.
0.5"UPVC Brass F.T.A.
1"UPVC Brass M.T.A.
0.5"UPVC Brass M.T.A.
1"UPVC elbow
0.5"UPVC elbow
2"UPVC elbow
1"UPVC T
0.5"UPVC T
2"UPVC T
1"UPVC union
0.5"UPVC union
2"UPVC union
end cap
Asbestas sheet
(sr no. 35 to sr no. 59 are as per market price)
Providing and supplying in std.length ISI marked rigid unplasticized PVC pipes suitable for portable water with solvent cement joints incluiding cost of couplers .excluding all staturoty duties and taxes levied by Govt. of India and Govt. of Mahrashtra in all respect education cess, VAT,charges including tranist insurance ,railway freight , unloading ,stacking , etc. complete , as directed by engineer -in -charge . Note-one coupler & required cement solventshall be provided with each full length pipe cost of which is included in rates below
a) Working pressure 6 kg/sq.cm
MJP DSR 2018-19 P. No. 97 ,I. No. 2 (b)
Lowering laying and jointing with PVC pipes and specials of following class and diameter including conveyance from stores to site of works .All labour , giving satisfactory hydraulic test , etc. complete . as directed by engineer in-charge
MJP DSR 2018-19 P. No. 97 ,I. No. 4 (b)
Fiarwel 1/2
Fiarwel 1/2
NRV Valves PN-10. 200 mm
NRV Valves PN-10. 350 mm
NRV Valves PN-10. 50 mm
NRV Valves PN-10. 40 mm
काँक्रीटी खिळे
1/2" U.P.V.C पाईप
1/2" U.P.V.C ब्रास F.T.A
1/2" U.P.V.C ब्रास M.T.A
1/2" U.P.V.C ब्रास एल्बो
1/2" U.P.V.C एल्बो
1/2" U.P.V.C टी
1/2" U.P.V.C टॅक नेपल
1/2" U.P.V.C सॉकेट
1/2" U.P.V.C युनेन
1" U.P.V.C पाईप
1" U.P.V.C ब्रास F.T.A
1" U.P.V.C ब्रास M.T.A
1" U.P.V.C ब्रास एल्बो
1" U.P.V.C टी
1" U.P.V.C सॉकेट
1" U.P.V.C टँक नेपर
1" U.P.V.C युनेन
1" U.P.V.C क्लिप
1" U.P.V.C वॉल्व
1" U.P.V.C एल्बो
1" G.I बेन्ड
1" G.I होज नेपल
1" एन्ड कॅप
स्वॉलवट
2" U.P.V.C पाईप
2" U.P.V.C ब्रास F.T.A
2" U.P.V.C ब्रास M.T.A
2" U.P.V.C ब्रास एल्बो
2" U.P.V.C टी
2" U.P.V.C सॉकेट
2" U.P.V.C टँक नेपर
2" U.P.V.C युनेन
2" U.P.V.C क्लिप
2" U.P.V.C वॉल्व
2" U.P.V.C एल्बो
2" G.I बेन्ड
2" G.I होज नेपल
2" एन्ड कॅप
सी टँक पाण्याची टाकी
Rahul J. Pardeshi
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .