| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.0 LAccepted-AOC 12 1 FERRIGHAT ROAD P O BHATPARA DIST NORTH 24 PGS WEST BENGAL PIN 743123 | BHATPARA | NORTH 24 PARGANAS | WEST BENGAL | 743123 | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹7.3 L+₹30,700 (4.38%)Rejected-Finance 14 BEPIN BEHARI GANGUALY STREET KOLKATA 700 012 | KOLKATA | KOLKATA | WEST BENGAL | 700012 | L2 | Rejected-Finance Higher
Quoted
Rate. | |
| 3 | L3₹7.5 L+₹47,750 (6.81%)Rejected-Finance GLYPTIC RAIPUR P O BHITA BURDWAN 713102 | BURDWAN | PURBA BARDHAMAN | WEST BENGAL | 713102 | L3 | Rejected-Finance Higher
Quoted
Rate. | |
| 4 | L4₹9.1 L+₹2.1 L (30.4%)Rejected-Finance 19B PANKAJINI CHATTERJEE ROAD CHARU MARKET KOLKATA WEST BENGAL 700033 UDYAM WB 10 0047115 | KOLKATA | WEST BENGAL | 700033 | L4 | Rejected-Finance Highest
Quoted
Rate. |
Tender Value
Refer Docs
EMD Value
₹18,000
Closing Date
25 Jul 2022, 12:00 pmClosed
SE, PWD, Kolkata Electrical Circle
P-16, India Exchange Place Extn. KIT Building, 2nd Floor, Kolkata-700073
Construction of International Standard Hockey Field and Grass Embankment Galleries at Vivekananda Yuba Bharati Krirangan----Fire Detection System.
2022_WBPWD_389523_1
PWD/SE/KEC/NIT-11/22-23
Open Tender
FIRE FIGHTING ORG
Item Rate
30 days
VYBK, Salt Lake Kolkata
Please refer Tender documents.
8 documents required · 8 mandatory
₹18,000
Office of the SE, PWD, Kolkata Electrical Circle
17 Nov 2022
11 Jul 2022
27 Jul 2022
11 Jul 2022
25 Jul 2022
19 Jul 2022
18 Jul 2022
Amount
Supply, Installation,Testing & Commisioning of Micropresssor controlled Addressable multisensor detector IP 42 (VDS / UL /ERTL/ LPCB / FM approved ) with inbuilt optical smoke sensors and heat detector sensors and heat detector sensor with inbuilt short circuit fault isolator as per NFPA style 7 wiring complete with base (Note : Detectors without built-in fault isolator is also acceptable provided one independent short circuit fault isolator is to be provided extra as per NFPA without extra cost) the detectors should have built in LED response indicator. The detector should have 360 degree optical view with single / multiple LED that blinks on actuation of detector. Reverse polarity or faulty zone wiring shall not damage the detectors. (Approved Make : Cerberus Pro / Johnson Controls / Edward/ Secutron/ Securiton/ Apollo / Morley / Eaton / GST/ Honeywell / Ravel).
Supply, Installation,Testing & Commisioning of Addressable Manual Call Point ( VDS / UL /ERTL/ LPCB / FM approved ) with in built short circuit fault isolator as per NFPA style 7 wiring complete as required. (Approved Make:v Cerberus Pro/ Johnson Controls/Edward/Secutron/ Securiton/ Apollo / Morley / Eaton/ GST / Honeywell / Ravel).
Supply, Installation, Testing & Commissioning of Addressable Loop Powered Hooter ( sound output of minimum 90 db ) cum strobe (strength of light 10 cd) complete with inbuilt short circuit fault isolator. Degree of protection IP65 ( VDS / UL /ERTL/ LPCB / FM approved) (Approved Make: Cerberus Pro/ Johnson Controls / Edward /Secutron/ Securiton/ Apollo / Morley / Eaton/ GST/ Honeywell/ Ravel).
Supply, Installation,Testing & Commisioning of Micropresssor controlled Addressable Heat detector IP 42 ( VDS / UL /ERTL/ LPCB / FM approved ) with combination of fixed type & Rate of Rise of Temperature feature. Detector shall have maximum triggering temperature programmable from 60 deg. C to 80 deg. C., having high level of immunity to electromagnetic influances and show alarm signal limit temperature is reached. Detector shall have inbuilt short circuit fault isolator as per NFPA style 7 wiring complete with base (Note : Detectors without built-in fault isolator is also acceptable provided one independent short circuit fault isolator part detector is to be provided extra as per NFPA without extra cost ) the detectors should have built in response LED indicator. (Approved Make: Cerberus Pro / Johnson Controls / Edward/ Secutron/ Securiton/ Apollo / Morley / Eaton / GST / Honeywell/ Ravel).
Supplying, installation, testing and commissioning of LED type Response Indicator ( VDS / UL /ERTL/ LPCB / FM approved) having 2 Nos. red coloured LED lamps including connections etc. (Approved Make : Cerberus Pro/ Johnson Controls / Edward /Secutron/ Securiton/ Apollo / Morley / Eaton/ GST/System Sensor/Agni Suraksha / Honeywell/ Ravel).
Supply & Laying of 2 Core 1.5 sq.mm FRLS shielded copper Cable (For Loop) (Make. Finolex/RR Kable/Polycab/Gloster/KEI) through 19 mm dia PVC 'FR' type Rigid Conduit pipe with necessary arrangement (Make : Precision/ AKG/ Universal/ Polycab) on the surface of the wall.
Supplying, Installing, Testing & Commissioning of Addressable Monitor/Control Modules (VDS/UL/ERTL/LPCB/FM approved) for monitoring Flow switches/Fire exit doors/ AHU/Lift etc. with inbuilt short circuit fault isolator and minimum (04) four poetntial free contact with adjustable setting parameter likes of input or output, complete in single or multiple housing with degree of protection IP 54 with flash LED indicator that conforms module is operational and intergrated buzzer signaling maintenance alarm, complete as required. (Approved Make :Cerberus Pro / Johnson Controls / Edward/ Secutron/ Securiton/ Apollo / Morley / Eaton / GST / Honeywell / Ravel)
Supply, Installation,Testing & Commisioning of Microprocessor based addressable fully networkable fire alarm control panel ( VDS / UL /ERTL/ LPCB / FM approved ) suitable for the devices as stated in the previous items of this BOQ along with 20% spare capacity with each loop loading not exceeding 80% of the full capacity of detectors and devices taken together, complying to IS 2189:2008 IP 50 rating or its latest amendments, and with minimum 600 character alpha - numeric liquid crystal display. The panel shall be soft addressable type and shall be able to give pin point location of all fire/ fault conditions. Further, the panel must be able to automatically switch off respective control switches with help monitor module whenever any alarm is triggered. The Panel should be able to store sufficient numbers of log events in its Memory as per recommended standards.
The panel shall have in built rectifier, provision for external & internal printer (if required), Loop cards, L C D unit to indicate Fire/Fault Signal with address and analog output, complete in all respects, in built Surge protection facility, integral SMF lead acid batteries with sealed cells of 24 V capable of running for 24 hours normal working and then be capable of operating the system for 60 minutes during Emergency condition, with integral battery charger complete in all respect as required.
The FACP shall be capable of being networked ( future expansion ) with other similar FACP located at different part of the premises through single RS 485 modbus. The FACP shall have provision for interfacing with the public address system, remote computer and BMS interface. The system must be preloaded with licenced software. (Approved Make : Cerberus Pro / Johnson Controls / Edward/ Secutron/ Securiton/ Apollo / Morley / Eaton / GST/Siemens/Honeywell / Ravel).
NOTE :- 1) The Fire Alarm system shall comply with latest requirements of -- (i) National Fire Protection Association (NFPA) Standards (ii) IS 2189 (iii) NFPA 70 National Electric Code (iv) NFPA 72 National Fire Alarm & Signaling Code (v) Local Statutory Regulations (vi) Manufacturer Recommendation (vii) System should be integrated with the components like FACP, Detectors, MCP, Hooter, Monitor Module, Relay Module, etc. and all these, components should be of same brand.
TESTS :- 1) The system shall he tested and commissioned by a qualified competent, trained engineer or technician authorized by the manufacturer of the fire alarm equipment to technically supervise and participate during all of the adjustments and tests (or the system). 2) Before energizing the cables and wires, inspection and check for correct connections, and test for short circuits, ground faults, continuity, and insulation and other tests as per applicable lndian/International standards must be done.
TERMS & CONDITIONS:- The Agency must procure the materials from the Manufacturer / OEM or from their authorised sales channel so that the standard warranty / support of the Manufacturer / OEM becomes applicable to the products to be delivered and installed by them. Documents that authenticates such procurement from the Manufacturer / OEM or from their authorized sales channel and standard warranty / support should be sent from the email of the Manufacturer / OEM / authorized sales channel to the e-mail of Engineer-in-Charge and hard copy of it to be submitted during execution of work/ submission of bill. lf any refurbished material is supplied and installed, penal action will be taken as per existing rules.
ASSOCIATED ELECTRICAL CONST CO. 1963 PVT.LTD
GLYPTIC
BALAJI FIRE PROTECTION SYSTEMS
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .