| Sl No | Description | Qty | Unit | SHANTI MARKETING AND SERVICES L4 | OM SAI POWER SYSTEMS L1 | Rahul Enterprises L2 | K LAKSHMAN SINGH AND CO L3 | S J REDDY L5 |
|---|---|---|---|---|---|---|---|---|
| 1.00 | Taking down carefully un serviceable point wiring of light points, fan, socket out let on TW battens/PVC pipes/casing & caping including material like sockets, switches, ceiling roses, regulators, light fittings etc and removing the materials from site and making good the disturbed portion of walls/floors ceiling etc complete all as specified and as directed. | 116 | Point | 1 ₹116 Lowest | 2 ₹232 | 19 ₹2,204 | 10 ₹1,160 | 17.1 ₹1,983.6 |
| 2.00 | Taking down Air circulator fan dismantling blades and removing fan and refixing fan after completion of re-wiring and connecting up by cleaning / oiling etc including provision of 3core flexible round cable from ceiling rose or connector to fan all as directed. | 30 | Each | 150 ₹4,500 | 50 ₹1,500 Lowest | 99 ₹2,970 | 250 ₹7,500 | 171 ₹5,130 |
| 3.00 | Taking down High bay lights after dismantling the bird proofing net and refixing high bay lights after completion of re-wiring and connecting up by cleaning etc including provision of 3core flexible round cable from ceiling rose or connector to high bay lights all as directed. | 64 | Each | 150 ₹9,600 | 50 ₹3,200 Lowest | 99 ₹6,336 | 250 ₹16,000 | 171 ₹10,944 |
| 4.00 | M & L for Point wiring with 1.5 Sqmm multistranded copper conductor wire with unsheathed, FRLS grade PVC insulated, single core with earth continuity conductor of 1.5 sqmm FRLS grade PVC insulated multistranded copper conductor and including In stove enamelled steel conduit concealed of suitable size but not less than 20mm dia. and all accessories fixed to the surface of the roof/ walls or in chases etc. including terminal boxes made out of MS sheet of thickness should be not less than 1.2mm thick for fixing of rotary switches, fan regulators socket outlet etc along-with 3mm thick top laminated bakelite sheet for housing switches, etc complete all as specified and as directed for the following :-
(a) One light point controlled by one switch | 4 | Point | 750 ₹3,000 | 850 ₹3,400 | 490 ₹1,960 Lowest | 600 ₹2,400 | 684 ₹2,736 |
| 5.00 | Supply and fixing LED light fitting 1x16 Watt flame proof, CMRI certified recommended for gas/ vapour group of IIA & IIIB, Zone 1 & 2 and IP 65 protection with die cast aluminium housing with heat resistant toughened glass with LED tube light fixtures driver, holders, connector etc. Complete with all accessories prewired and including connecting up with three core flexible copper conductor cable with suitable
size. | 4 | Each | 4,500 ₹18,000 Lowest | 11,500 ₹46,000 | 4,900 ₹19,600 | 11,500 ₹46,000 | 8,550 ₹34,200 |
| 6.00 | M & L for Switch flame proof rotary type with termination box in LM6, 10/16A, On/off switch w single pole 250V with complete all as specified and as directed. | 4 | Each | 2,500 ₹10,000 | 4,500 ₹18,000 | 129 ₹516 Lowest | 3,500 ₹14,000 | 6,840 ₹27,360 |
| 7.00 | M & L for Point wiring with 1.5 Sqmm multistranded copper conductor wire with unsheathed, FRLS grade PVC insulated, single core with earth continuity conductor of 1.5 sqmm FRLS grade PVC insulated multistranded copper conductor and including rigid PVC conduit concealed of suitable size but not less than 20mm dia. and all accessories fixed to the surface of the roof/ walls or in chases etc. including terminal boxes made out of MS sheet of thickness should be not less than 1.2mm thick for fixing of switches, fan regulators socket outlet etc along-with 3mm thick top laminated bakelite sheet for housing switches, etc complete all as specified and as directed for the following :-
(a) One light point controlled by one switch | 41 | Point | 750 ₹30,750 | 350 ₹14,350 Lowest | 490 ₹20,090 | 600 ₹24,600 | 598.5 ₹24,538.5 |
| 8.00 | (b) One fan point controlled by one switch | 30 | Point | 750 ₹22,500 | 350 ₹10,500 Lowest | 490 ₹14,700 | 600 ₹18,000 | 598.5 ₹17,955 |
| 9.00 | (c) One three pin socket 5 Amps independent with 1.5 sq mm copper conductor | 10 | Point | 750 ₹7,500 | 350 ₹3,500 Lowest | 490 ₹4,900 | 600 ₹6,000 | 598.5 ₹5,985 |
| 10.00 | Same as item No. 4 above but with 2.5 Sqmm multistranded copper conductor wire with 2.5 Sqmm multistranded copper wire as earth continuity conductor in and including PVC conduit (not less than 20 mm) complete all as directed for 15 A socket | 35 | Point | 1,250 ₹43,750 | 450 ₹15,750 Lowest | 590 ₹20,650 | 650 ₹22,750 | 855 ₹29,925 |
Tender Value
₹46.5 L
EMD Value
₹92,954
Closing Date
17 Jul 2025, 6:00 pmClosed
GE (AFA) HYDERABAD
GE (AFA) Hyderabad, Dundigal, Hyderabad
SPECIAL REPAIRS TO RE-WIRING AT TWIN HANGAR ALONG WITH ANNEXES AT AFA HYDERABAD AND SPECIAL REPAIRS/ REPLACEMENT TO UNSERVICEABLE EARTHING PITS AT VARIOUS LOCATIONS AT AFA HYDERABAD
2025_MES_715580_1
8579/E8
Open Tender
Civil Works
Item Rate
180 days
HYDERABAD
Please refer Tender documents.
5 documents required · 5 mandatory
₹500
GE (AFA) HYDERABAD
₹92,954
Yes
23 Feb 2026
19 Jun 2025
19 Jul 2025
19 Jun 2025
17 Jul 2025
3 Jul 2025
19 Jun 2025 - 2 Jul 2025
Amount
Taking down carefully un serviceable point wiring of light points, fan, socket out let on TW battens/PVC pipes/casing & caping including material like sockets, switches, ceiling roses, regulators, light fittings etc and removing the materials from site and making good the disturbed portion of walls/floors ceiling etc complete all as specified and as directed.
Taking down Air circulator fan dismantling blades and removing fan and refixing fan after completion of re-wiring and connecting up by cleaning / oiling etc including provision of 3core flexible round cable from ceiling rose or connector to fan all as directed.
Taking down High bay lights after dismantling the bird proofing net and refixing high bay lights after completion of re-wiring and connecting up by cleaning etc including provision of 3core flexible round cable from ceiling rose or connector to high bay lights all as directed.
M & L for Point wiring with 1.5 Sqmm multistranded copper conductor wire with unsheathed, FRLS grade PVC insulated, single core with earth continuity conductor of 1.5 sqmm FRLS grade PVC insulated multistranded copper conductor and including In stove enamelled steel conduit concealed of suitable size but not less than 20mm dia. and all accessories fixed to the surface of the roof/ walls or in chases etc. including terminal boxes made out of MS sheet of thickness should be not less than 1.2mm thick for fixing of rotary switches, fan regulators socket outlet etc along-with 3mm thick top laminated bakelite sheet for housing switches, etc complete all as specified and as directed for the following :- (a) One light point controlled by one switch
Supply and fixing LED light fitting 1x16 Watt flame proof, CMRI certified recommended for gas/ vapour group of IIA & IIIB, Zone 1 & 2 and IP 65 protection with die cast aluminium housing with heat resistant toughened glass with LED tube light fixtures driver, holders, connector etc. Complete with all accessories prewired and including connecting up with three core flexible copper conductor cable with suitable size.
M & L for Switch flame proof rotary type with termination box in LM6, 10/16A, On/off switch w single pole 250V with complete all as specified and as directed.
M & L for Point wiring with 1.5 Sqmm multistranded copper conductor wire with unsheathed, FRLS grade PVC insulated, single core with earth continuity conductor of 1.5 sqmm FRLS grade PVC insulated multistranded copper conductor and including rigid PVC conduit concealed of suitable size but not less than 20mm dia. and all accessories fixed to the surface of the roof/ walls or in chases etc. including terminal boxes made out of MS sheet of thickness should be not less than 1.2mm thick for fixing of switches, fan regulators socket outlet etc along-with 3mm thick top laminated bakelite sheet for housing switches, etc complete all as specified and as directed for the following :- (a) One light point controlled by one switch
(b) One fan point controlled by one switch
(c) One three pin socket 5 Amps independent with 1.5 sq mm copper conductor
Same as item No. 4 above but with 2.5 Sqmm multistranded copper conductor wire with 2.5 Sqmm multistranded copper wire as earth continuity conductor in and including PVC conduit (not less than 20 mm) complete all as directed for 15 A socket
S&FPVC Gang Box suitable for 15Amps Switch Socket Combination complete all as specified and as directed.
S&F Switch socket combination polycorbonate white 2 in 1, 3 pin, 5 Amp flush type universal complete all as specified and as directed.
S&F of ceiling rose, three terminal, PVC/polycarbonate, insulated body, ISI marked complete all as specified and as directed.
Supply and fix switch piano flush type, single pole, two way, 5 Amps, 230 volts, ISI marked complete .ISI marked complete all as specified and as directed.
Supply and lay LT UG cable, XLPE insulated armoured, heavy duty aluminium conductor multistranded, 1100volts grade, of 25 Sqmm x 4 core cross sectional area laid in trenches / fixing on walls / poles or passing through GI pipe including connecting up with suitable lugs, nuts and bolts wherever required and testing complete all as specified.
M&L for Sub Main wiring with four runs of 10sq mm 1100 V grade (nominal area) single core FRLS grade PVC insulated unsheathed wire with multi-stranded copper conductor, drawn through and including medium grade, rigid non-metallic PVC conduit / casing & caping (as per site requirement) of suitable size with all necessary fittings, surface in walls/roof/floor duly earthed with two runs of single core cable of same size but green in colour as continuous earthing wire and connecting to common earth dolly complete and after taking out the existing sub-main wiring etc. complete all as specified and as directed. (TPN DB to TPN DB) Note :- (i) Necessary PVC dummy plates & rigid PVC junction boxes for maint./inspection purpose as required on site/directed by Engr-in-charge shall deemed to be included in the quoted rate. (ii) Same size wire shall be used for phase, neutral & earth conductor (iii) The wiring shall be done strictly by following proper colour coding using red, yellow and blue for phase, black for neutral and green for earth leads. (iv) Six runs of cable and one run of PVC conduit / casing caping will be measured as one unit.
M&L for Sub Main wiring with four runs of 6sq mm 1100 V grade (nominal area) single core PVC insulated unsheathed cable multi-stranded copper conductor drawn through medium grade, rigid non-metallic PVC conduit / casing & caping (as per site requirement) of suitable size with all necessary fittings, surface in walls/roof/floor duly earthed with two runs of single core cable of same size but green in colour as continuous earthing wire and connecting to common earth dolly complete and after taking out the existing sub-main wiring etc. complete all as specified and as directed. (3 Phase Sockets ) Note :- (i) Necessary PVC dummy plates & PVC rigid junction boxes for identifying junction as required on site/directed by Engr-in-charge shall deemed to be included in the quoted rate. (ii) Same size wire shall be used for phase, neutral & earth conductor (iii) The wiring shall be done strictly by following proper colour coding using red, yellow and blue only for phase, black for neutral and green for earth leads. (iv) Three runs of cable and one run of PVC conduit / casing caping will be measured as one length.
M&L for Sub Main wiring with two runs of 4sq mm 1100 V grade (nominal area) single core PVC insulated unsheathed cable multi-stranded copper conductor drawn through and including medium grade, rigid non-metallic PVC conduit / casing & caping (as per site requirement) of suitable size with all necessary fittings, surface in walls/roof/floor duly earthed with one run of single core cable of same size but green in colour as continuous earthing wire and connecting to common earth dolly complete and after taking out the existing sub-main wiring etc. complete all as specified and as directed. (For SPN DB) Note:-(i) Necessary PVC dummy plates & rigid PVC junction boxes for maint./inspection purpose as required on site/directed by Engr-in-charge shall deemed to be included in the quoted rate. (ii) Same size wire shall be used for phase, neutral & earth conductor (iii) The wiring shall be done strictly by following proper colour coding using red, yellow and blue only for phase, black for neutral and green for earth leads. (iv) Three runs of cable and one run of PVC conduit / casing caping will be measured as one unit.
M&L for Sub Main wiring with two runs of 2.5sq mm 1100 V grade (nominal area) single core PVC insulated unsheathed cable multi-stranded copper conductor drawn through and including medium grade, rigid non-metallic PVC conduit / casing & caping (as per site requirement) of suitable size with all necessary fittings, surface in walls/roof/floor duly earthed with one run of single core cable of same size but green in colour as continuous earthing wire and connecting to common earth dolly complete and after taking out the existing sub-main wiring etc. complete all as specified and as directed. (for High bay lights, air circulator fans, 15 A sockets) Note:-(i) Necessary PVC dummy plates & rigid PVC junction boxes for maint./inspection purpose as required on site/directed by Engr-in-charge shall deemed to be included in the quoted rate. (ii) Same size wire shall be used for phase, neutral & earth conductor (iii) The wiring shall be done strictly by following proper colour coding using red, yellow and blue only for phase, black for neutral and green for earth leads.
Taking out old unserviceable distribution board of any type and S&F of MCB DB, double door 6 way triple pole vertical type 415 volts 50 Hz AC supply suitable for 4 pole MCCB incomer, fixed to the existing wall (concealed/ surface) after removing the existing un serviceable MCB DB and reconnecting the electrical connections and making good the disturbed surface of wall to perfectly match with the existing wall complete all as specified and as directed. Note : MCCB will be measured and paid separately under relevant items.
Taking out old unserviceable distribution board of any type and S&F of MCB DB SPN 12 way with copper bus bar & neutral link double door type to be fixed in the wall including connections and making good the disturbed surface of wall to perfectly match with the exsting wall complete all as specified and as directed.
Taking out old unserviceable MCB any type and S&F of MCB SPN 6 to 32A, 'C' curve, 10KA rupturing capacity complete all as specified and as directed.
Taking out old unserviceable MCB any type and S&F of Fix MCB SP 6 to 32 A, 'C' curve, 10 KA rupturing capacity complete all as specified and as directed.
Taking out old unserviceable distribution board of any type and S&F of MCB TPTP 25 To 63 AMP,10KA breaking capacity, 415Volts complete all as specified and as directed.
S & F of industrial wall mounted Plug and scoket 3P+N+E 32Amps with MCB protection suitable for IP40 degree protection to be fixed in the existing wall in concealed and connecting the electrical connections and making good the disturbed surface wall with the existing wall complete all as specified and as directed.
Supply & Fixing High Bay industrial LED Luminaire 150 watts power factor 0.95, power consumption 150 watts rated Liminous Lux-15000Lm,color Temperature -6000K (WH) complete with all fixing accessories, clamps nuts, bolts, and necessary connection from nearby existing ceiling rose by providing 3 core multiflexible round copper wire of size 1.5 sqmm complete all as specified and directed.
S&F surface mounting / wall mounted LED tube light fitting 1x20 Watt (Lumen output not less than 1980 lumen) high efficiency, anti glare, maintenance free operation including LED driver, Tube 20W/18W and mounting arrangements, all accessories internally pre-wired, connecting up with three core twisted flexible copper conductor cable white colour with suitable size including taking out old unserviceable one complete all as specified and as directed.
Supply & Fixing 1x10W LED Tube light fitting having housing with high pressure die cast aluminium, poly carbonate front diffuser cover including LED driver, Lamp and all accessories internally pre-wired, connecting up with three core twisted flexible copper conductor cable with cross sectional area 1.0 Sqmm including taking out old unserviceable one complete all as specified and as directed.
S&F perforated cable tray, made of 2 mm Galvanized iron sheet, duly bended ro required shape by sheet bending machine, including cover made of 1.2 mm thick plain galvanized iron sheet duly screwed with the cable tray and duly fixed on the wall/ceilings including suitable Galvanized iron brackets or hanging from ceiling with suitable suspender as required at site all as specified and as directed by Engineer-in-charge for the following sizes:- (a) Tray size 100x250x2mm with cover of size 15x255x1.2mm
Excavation in trenches not exceeding 1.5m wide and not exc 1.50 mtr in depth in hard / dense soil and getting out for laying pipes, repairs to water mains / valves / valve chamber including forming of bottom surface to required level and gradient complete all as specified and as directed
M&L River dry sand cushioning to UG cables (8 cm deep before laying of cable and 15 cm deep over the cable) in trenches including punned thickness up to 18 cm and consolidation, complete aii as directed. Note: Punned thickness only will be considered for payment.
Supply and lay common burnt, clay building bricks, sub class 'B' designation over the sand cushioning in cable trenched for protection of cables (LT) complete all as specified and as directed.
M&L for maintenance free chemical earthing with 01 No of copper cladded 17.2mm dia nickel cadmium steel with high tensile strength electrode of each of 3.0 m with suitable compressive coupler planted at depth not less than 3.0 m depth and duly covered with low resistant superior conductive powdered non corrosive, concrete brand earth enhancing material all as directed including connecting up to the common bus bar for a length upto 7.5 m with copper strip of size 20 x 3mm to achieve an earth resistance of below 1.0 Ohms including suitable PCC earth chamber. The copper strip shall be jointed to electrode with exothermic welding and all other joints shall be properly brazed after dismantling the existing unserviceable earthing complete all as specified and as directed. Unit measured :- Each gride of one Earth
Supply and fix in repairs of earthing complete with Galvanised steel earth plate electrode 600 mm x 600 mm x 6 mm thick burried directly in ground (earth pit not less than 2.25 mtr deep below GL) with top edge of earth plate not less than 1.5 Mtr below normal ground level, earth plate surrounded from all sides by 15cm thick packed layer of charcoal dust and common salt filled in alternate layers and electrode connections by using Galvanised earth strip 32x6mm connected by means of bolts, nuts, check nuts and washer of galvanised iron or steel, provision of 40 mm dia GI pipe medium grade for protection of GI earth strip and 20mm dia GI pipe medium grade for watering arrangement and PCC (1:3:6) type C1 chamber of size 45cm X 45cm X 45cm including, MS funnel, wire mesh, 50 mm thick RCC 1:2:4 type B1 earth pit cover with 6 Nos, 8 mm dia high strength deformed steel TMT bars on both ways including necessary excavation in any type of soil, returning, filling in, removal of surplus soil to distance n exc 50 mtr, provision of charcoal and salt complete all as shown in electrical plate No 3 of schedule Part-I complete all as specified and as directed. Note:- (i) Cost of GI earth strip and GI protection pipe upto 7.5mtr length shall be deemed to be included in the rate quoted for this item. (ii) The unit rate shall also includes for Wire mesh, funnel, excavation, returning filling , removing , PCC chamber pit, RCC cover, test point etc.
Supply and fixed in repair Test Point Terminal Block made of gun metal or Phosphorus bronze size 75 mm x 75mm x25 mm, drilled and screwed and including 3 Nos 8 mm dia 25 mm long head screws. complete all as specified and as directed.
S&F in repairs DMC / FRP insulators, of suitable size to seperate the earth strips from the walls, duly screwed on the walls and making holes in the earth strips by drilling and fixing the earth strip rigidly with the insulators with GI bolts, nuts, washers etc complete all as specified and as directed.
S& F in repair Earthing grid indicator made out of 3 mm thick MS sheet of different sizes and shapes as per ground requirement duly welded with 500 mm long 25x25x6mm angle iron duly fixed near to the grid point with cement grout including writing earthing details such as earth resistance, connected to etc complete all as specified and as directed. Note: the quoted rate includes painting of chamber and indicator
S&F in repairs GI strip 25 x 4 mm with DMC / FRP insulators fixing screws etc. for roof conductors / down conductors / connecting to earth pit to equipment including removing the old unserviceable strip and brazing all the joints complete all as specified and as directed.
S&F in repairs GI strip 32 x 6 mm with DMC / FRP insulators fixing screws etc. for roof conductors / down conductors / connecting to earth pit to equipment including removing the old unserviceable strip and brazing all the joints complete all as specified and as directed.
Supply and fixed in repair Copper strip 20 x 3 mm along with DMC / FRP insulators & fixing screws etc. for roof conductors / down conductors / connecting to earth pit to equipment including removing the old unserviceable strip and brazing all the joints complete all as specified and as directed.
S&F in repairs Copper strip 32 x 6 mm with DMC / FRP insulators fixing screws etc. for roof conductors / down conductors / connecting to earth pit to equipment including removing the old unserviceable strip and brazing all the joints complete all as specified and as directed.
S&F in repair earth pit chambers with size of PCC (1:3:6) type C1 chamber of size 45cm X 45cm X 45cm including, MS funnel, wire mesh, 50 mm thick RCC 1:2:4 type B1 earth pit cover with 6 Nos, 8 mm dia high strength deformed steel TMT bars on both ways including necessary excavation in any type of soil, returning, filling in, removal of surplus soil to distance n exc 50 mtr,
Supply and fix in repair 20mm GI pipe light grade with screwed joints, tube fillings such as bends, elbows, tees, short pieces, connectors, back-nuts, diminishing pieces, caps,plugs and unions, etc and fixing complete with clips, wall hooks, wooden plugs,or laying in trenches etc,also for cutting, screwing and waste for making forged bends on piping as required. connectors shall be inserted, where required or directed. The rates also include cutting through walls, floors, etc and their making good.
Supply and fix in repair 25mm GI pipe light grade with screwed joints, tube fillings such as bends, elbows, tees,short pieces, connectors, back-nuts,diminishing pieces, caps, plugs and unions,etc and fixing complete with clips, wall hooks, wooden plugs, or laying in trenches etc, also for cutting, screwing and waste for making forged bends on piping as required. connectors shall be inserted, where required or directed.The rates also include cutting through walls, floors, etc and their making good.
Excavation in trenches in any kind of soil n.exc 1.5 m wide and n. exc 1.5 m depth and getting out, including trimming the sides and forming bottom surface to required levels for laying cables complete all as specified and as directed.
Returning, filling in trenches in any kind soil in layers n.exc. 25 cm after laying of cables including spreading, levelling, and well ramming complete all as specified and directed.
Removing surplus excavated material (soil) to a distance not exceeding 50 metre and not excee 250m depositing where directed at a level not exceeding 1.5 metre above the starting point complete all as specified and as directed
S &F Plug type bib taps, cast iron, screwed for iron pipe and fixed including all accessories of nuts, bolts and washers etc of 20 mm size any colour high pressure screwed for iron pipe and fixed.(minimum weight 20mm-125gms) all as specified and directed by engr-in-charge.
S &F Plug type bib taps, cast iron, screwed for iron pipe and fixed including all accessories of nuts, bolts and washers etc of 25 mm size any colour high pressure screwed for iron pipe and fixed.(minimum weight 150 gms) all as specified and directed by engr-in-charge.
Rahul Enterprises (BID ID -3362032)
K LAKSHMAN SINGH AND CO (BID ID -3350859)
SHANTI MARKETING AND SERVICES (BID ID -3353559)
S J REDDY (BID ID -3352502)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .