Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹25.9 LAccepted-Finance | 1 | Accepted-Finance FINANCIAL BID OK | |
| 2 | 2₹28.5 L+₹2.6 L (10.0%)Accepted-Finance | 2 | Accepted-Finance FINANCIAL BID OK |
Tender Value
Refer Docs
EMD Value
₹24,000
Closing Date
13 Apr 2023, 9:30 amClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
HOD MATERIALS
KEL KUNDARA PB NO 8 KOLLAM KERALA
Supply, testing and commissioning of 250 kVA outdoor USS and connected electrics
2023_KEL_570672_2
KEL/FL/MMD/K113/EPROC/22-23
Open Tender
Electrical Works
Item Rate
15 days
Ambalavayal, Wayanad
Only bidders who are working for KEL, Kundara for the last 6 months is allowed to participate in Tender as this is an immediate work. Also Please see section 3 in NIT
3 documents required · 3 mandatory
₹4,800
Yes
₹24,000
Yes
14 Apr 2023
6 Apr 2023
14 Apr 2023
6 Apr 2023
13 Apr 2023
6 Apr 2023
6 Apr 2023 - 13 Apr 2023
Construction of Plinth ( brick/granite/stone masonary of 40 cm height from ground level and 40 cm below ground level and P.C.C. of 15cm on the top side) for mounting USS. The diamension of the plint shall be suitable to transformer.
Unitised Substation- outdoor type 250 kVA 11 kV USS (dry type):- Design, Fabrication, Supply outdoor type Unitized substation enclosure consisting of HT compartment with 11kV load break switch, Transformer compartment with 250 kVA, 11kV/433V 3Ph 50Hz vector Dyn-11, cast resin type, transformer with IP54 enclosure, winding temparature alarm and trip, necessary louvers, all standard fittings and accessories, LV chambers suitable for termination of necessory power and control cabling for alarm, tripping & indication, all required internal cabling etc complete and as per specifications in all respects. HT compartment:- 11 kV, 26kA for 3 seconds, 630A LBS. 630A continuously rated Al busbar. Seal off Bushing, Shunt Trip coil, Space Heater with thermostat. CT ratio **/5A, 15VA,CL0.2S:- 3 nos, PT ratio:11kV/110V, 25VA, Cl:0.2,Provision for TOD meter, padlocking for open, close, earth, test position. Transformer Compartment(Dry Type):- 250 kVA 11kV/433V 3 Ph 50 Hz, Dry Type Vector Dyn-11 transformer copper wound, CRGO laminated, Class F insulation, indoor distribution Transformer with air natural cooling. The transformer shall have Delta on HV side and Star on LV side with off load tap changer range:+5% to-10% in steps of 2.5%. LT chamber:- should be suitable for terminating & connecting LT cables,
Unloading, Leading, Test and Commissioning of 250kVA outdoor USS.
Supply, Erection and Commissioning of -/5A, class 0.2s, 11kV/110V 4 wire HT TOD meter and test terminal block.
Design, Fabrication, Supply, erection, testing and commissioning of MSB (Main switch board) with sheet steel clad, totally enclosed, dust tight and vermin proof, floor mounded indoor cubicle type, fabricated out of 16 SWG MS sheet and high conductivity aluminium bus bars for adequate size of operation on 3 phase, 4wire, 415V, 50Hz, AC supply system, with PVC sleaved and air insulated, the switch fuse units, breakers, all meters and relays etc. should be reputed make and conforming IS specification and are assembled, interconnected, earthed and the switch board should be painted with anti rust primer coating followed by two coats of paint of approved shade by Kerala Electrical Inpectorate and relevant standards. Incomer: 400A 4P Microprocessor type MCCB having isolation duty with 3 O/C and 1 E/F, Including rotary handle and spreader link - 1No. Outgoings :320A 4P MCCB-1No, 200A 4P MCCB-1No, 125A 4P MCCB- 2Nos. Bus bar:- Adequate size for oparation of 400A TPN. Metering and indications:-VAF meter, 400/5 CT coil - 3nos, CDG 11 or equelent earth fault relays, indicating lamps, control fuses etc.complete as per KEI standards.
Supply, Fabrication and fitting suitable size angle frame stand for mounting MSB Panel and 2 coat of painting (1 coat of epoxy coating and 2nd coat of enamel coating).
Supply, fabrication and fitting suitable size roofing for MSB and APFC Panel to protect against weather (rain) and 2 coat of painting (1 coat of epoxy coating and 2nd coat of enamel coating).
Supply and fitting neutral CT with suitable metal box.
Supply, instalation, testing and commissioning of 4 Way 125A MCCB DB emprising of 125A, 4P, MCCB 1 No.as incomer and 63A TP MCB-2Nos, 32A TP MCB-2Nos as out going. With tined copper bus bars, interconnections, as per KEI standards fixed in open system.
Supply,laying & commissioning of XLPE insulated PVC sheathed 11 kV grade armoured aluminium cables of 3CX150 Sq mm size through existing trench as directed complete.
Supply Indoor & Outdoor Termination Kit for 3 x 150 Sq mm XLPE cable and provide cable termination.
Supply. Laying, Testing and Commissioning of PVC insulated and PVC sheathed armoured aluminium/ Copper power cable of 1.1kV grade of the following sizes in ground including excavation of trench of size 35x75cm, refilling the trench etc. as required but including sand cushioning and protective covering (in ordinary soil).
3.5 x 185 sq.mm Al Cable
3.5 x 150 sq.mm Al Cable
3.5 x 50 sq.mm Al Cable
3.5 x 25 sq.mm Al Cable
4 x 1.5 sq.mm Cu Cable
2 x 2.5 sq.mm Cu Cable
Supply of all materials and providing end termination of following size PVC/XPLE insulated sheathed armoured aluminium and copper conductor cables (1.1kV grade) for giving connection to equipments etc. complete as per standards including accessories like cable sockets.
3.5 x 185 sq.mm
3.5 x 150 sq.mm
3.5 x 50 sq.mm
3.5 x 25 sq.mm
2.5 x 2.5 sq.mm & 4 x 1.5 sq.mm
Supply of all material providing earthing using 1200mm x 1200mm x12.5mm size Cl earth plate buried in ground at a depth of 3.0m from ground level with alternate layers of charcoal and common salt including supply and fixing of 38mm dia 'B' class GI pipe, funnel for watering purpose, copper strips interconnection including construction of masonry chamber with MS cover as per IS 3043-1987.
Supply following size of GI/Copper flats/wires for earthing of transformer, Panel board etc. and interconnection of earth pits as per technical specification. Earth strip/wires to be taken through GI pipes/cable trays/Hume pipes/built in trunches/soil etc. wherever necessary. Rate inclusive of connected civil works, necessary tinning, providing sockets and end termination of GI/copper strips/wires with all accessories required for the complete work.
25 x 6 GI strip
25 x 3 Copper strip
SWG 10 Copper wire
APFC PANEL (80kVAr) Supply, fabrication, installation, testing and commissionning of In-door type electrical APFC Switch Board Panel suitable for 415volts 3ph, 50Hz AC system with the required i.e. APFC Relay, Auto-Manual Switch, timer, Heavy duty Power capacitor Contactors, CT/PT, capacitor duty contactor, Indication lamps, Push button and all other necessary equipment switchgear and accessories and having suitable enclosure compartmentalized, totally enclosed free standing, Floor/wall mounted type, suitable bus bar, earthing arragement, suitable for operation from front side and ready for installation at site. I) Incomer 250A isolator II) 15kVAr Capacitor and contactor - 3 Nos. III) 10kVAr Capacitor and contactor - 2 Nos. IV) 5kVAr Capacitor and contactor - 3 Nos.
Supply and fixing of MS cable trays.
Supply and providing First Aid Chart duly framed and placed in a location for clear vision.
Supply and providing 6Kg, ABC Dry Chemical Powder type Fire Extinguisher with hose and clamps to wall as required.
Supply and providing danger notice board of size 200x150 mm as directed by departmental officers.
Supply and providing 11kV rubber hand long glove.
Supply and providing 2mm thick Elastomeric fire retardent insulating mat as per IS 15652/2006 to withstand 3.3kV dielectric strength near panel board.
Supply and providing suitable thick 11kV HT Elastomeric fire retardent insulating mat.
Painting letters or figures of the following sizes with enamel paint as identification marks, etc to panel board.
Supply and providing 9 litre capacity GI Fire Bucket painted in post office red with primer coat of red oxide and written with white paint FIRE, mounted on MS angle frame work/wall bracket filled with fine sand, painting the bracket/floor stand including making good the damages, colour washinig etc, as required.
Preparation of electrical drawing for getting approval and Energization Order from Electrical Inspectorate and providing Commission Certificate to KSEB.
To and Fro Conveyance and testing fee for TOD meter, CT:PT unit at TMR division.
Testing fee for Neutral CTs, Earth fault relays and Soil resistivity test, Scrutiny, Inspection fee etc. to be remitted to Electrical Inspectorate.
YOOSAF K A
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .