Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
Tender Value
₹45.0 L
EMD Value
₹40,000
Closing Date
15 Dec 2026, 3:00 pm
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
Executive Engineer UGVCL Division Office Sidhpur
E TENDER FOR LABOUR CHARGES OF UNDER GROUND WORK FOR LAYING 11 KV XLPE CABLEWORK (RAILWAYBRIDGE/TRACK/NHAI CROSSING IN ALL SCHEME UNDER SIDHPUR DIVISION(IF ANY EMERGENCY IN ANY SDN)
368177
UGVCL-SIDH-DO-10-2026-27 SNR:02
Open
Electrical and Maintenance Works
Works
Patan
1 document required · 1 mandatory
₹1,180
SIDHPUR
₹40,000
21 Nov 2026
21 Nov 2026
21 Nov 2026
15 Dec 2026
21 Nov 2026
180 days
Description UOM QTY RATE
LABOUR CHARGE FOR LAYING
UNDERGROUND XLPE CABLE INCLUDING
DIGGING OF PIT (4FT.) AND LAYING OF CABLE
1 Number 20 335
WITH PROVIDING CABLE TRENCH WITH
BRICKS & SAND PROVIDING OF CABLE
PROVIDING & LAYING OF HDPE PIPE
CONFIRMING TO IS 4984:1955 (AMENDMENT
NO.2) HAVING 160MM DIAMETER AND
MINIMUM 5MM THICKNESS AT A MINIMUM
DEPTH OF 1200MM BELOW THE ROAD
SURFACE BY PUSH THROUGH METHOD,
DRILLING THE ROAD WITH HDD MACHINE/
MANUALLY WITHOUT BREAKING THE ROAD
SURFACE AND LAYING OF ANY SIZE OF HT
XLPE INSULATED ALUMINIUM ARMOURED
CABLE THROUGH THE DUCT AS PER THE
INSTRUCTION OF EIC AND SPECIFICATIONS
INCLUDING COST OF HDPE PIPE. ONLY CABLE
WILL BE SUPPLIED BY UGVCL.
PROVIDING & LAYING OF HDPE PIPE
CONFIRMING TO IS 4984:1955 (AMENDMENT
NO.2) HAVING 110MM DIAMETER AND
MINIMUM 5MM THICKNESS AT A MINIMUM
DEPTH OF 1200MM BELOW THE ROAD
SURFACE BY PUSH THROUGH METHOD,
DRILLING THE ROAD WITH HDD MACHINE/
MANUALLY WITHOUT BREAKING THE ROAD
SURFACE AND LAYING OF ANY SIZE OF HT
XLPE INSULATED ALUMINIUM ARMOURED
CABLE THROUGH THE DUCT AS PER THE
INSTRUCTION OF EIC AND SPECIFICATIONS
INCLUDING COST OF HDPE PIPE. ONLY CABLE
WILL BE SUPPLIED BY UGVCL.
Signature of Tenderer Company’s Round Seal Page 1 of
Place: Signature of Tenderer Date:
Save Energy for Benefit of Self and Nation
LAYING OF VARIOUS SIZE SINGLE CIRCUIT OF
11KV XLPE INSULATED ALUMINIUM
ARMOURED CABLE IN CABLE TRENCH UPTO
THE MINIMUM DEPTH OF 1200MM IS TO BE
DUG WITH WIDTH OF 300MM IN ANY TYPE
OF SOIL. SPREADING OF SAND AT BOTTOM
OF THE TRENCH UPTO 100MM BEFORE LYING
OF POWER CABLE IN THE CENTRE OF THE
TRENCH. SPREADING OF ANOTHER LAYER OF
100MM SAND ABOVE LAID CABLE. UTMOST
CARE SHOULD BE TAKEN WHILE
LOADING/UNLOADING AND UNWINDING THE
4 CABLE DRUMS. COVERING THE CABLE WITH Meter 20 400
RCC HALF ROUND HUME PIPE 30MM THICK,
150MM INNER DIA. BEFORE REFILLING PRE-
BONDING TAP/WARNING TAP SHOULD
PROVIDE BELOW 700MM FROM THE
GROUND LEVEL AND BACK FILING THE SAME
TO MAKE GROUND LEVEL AS PER ORIGINAL.
BACK FEELING THE TRENCH SO AS TO MAKE
GROUND LEVEL AS PER ORIGINAL. LAID
CABLE UPTO CABLE BOX OF PLINTH
MOUNTED RMU/ TRANSFORMER SHALL BE
PART OF NORMAL LAYING.(THE RATES ARE
EXCLUDING SUPPLY OF CABLE)
LAYING OF VARIOUS SIZE DOUBLE CIRCUIT OF
11KV XLPE INSULATED ALUMINIUM
ARMOURED CABLE IN CABLE TRENCH UPTO
THE MINIMUM DEPTH OF 1200MM IS TO BE
DUG WITH WIDTH OF 500MM IN ANY TYPE
OF SOIL. SPREADING OF SAND AT BOTTOM
OF THE TRENCH UPTO 100MM BEFORE LYING
OF POWER CABLE IN THE CENTRE OF THE
TRENCH. SPREADING OF ANOTHER LAYER OF
100MM SAND ABOVE LAID CABLE. UTMOST
CARE SHOULD BE TAKEN WHILE
5 LOADING/UNLOADING AND UNWINDING THE Meter 20 558.26
CABLE DRUMS. COVERING THE CABLE WITH
RCC HALF ROUND HUME PIPE 30MM THICK,
150MM INNER DIA. BEFORE REFILLING PRE-
BONDING TAP/WARNING TAP SHOULD
PROVIDE BELOW 700MM FROM THE
GROUND LEVEL AND BACK FILING THE SAME
TO MAKE GROUND LEVEL AS PER ORIGINAL.
BACK FEELING THE TRENCH SO AS TO MAKE
GROUND LEVEL AS PER ORIGINAL. LAID
CABLE UPTO CABLE BOX OF PLINTH
MOUNTED RMU/ TRANSFORMER SHALL BE
Signature of Tenderer Company’s Round Seal Page 2 of
Place: Signature of Tenderer Date:
Save Energy for Benefit of Self and Nation
PART OF NORMAL LAYING.(THE RATES ARE
EXCLUDING SUPPLY OF CABLE)
LAYING OF VARIOUS SIZES OF 11KV XLPE
INSULATED ALUMINIUM ARMOURED CABLE
6 IN CABLE TRAY/TRENCH OVER/BELOW THE Meter 20 179.13
GROUND LEVEL(THE RATES ARE EXCLUDING
CABLE TRAY, ONLY LABOUR CHARGES)
LAYING OF VARIOUS SIZE OF 11KV XLPE
INSULATED ALUMINIUM ARMOURED CABLE
ABOVE GROUND IN AIR FOR TERMINATION
OF CABLE ON POLE WITH CLAMPS MADE
7 FROM GI FLAT 50X6 MM FOR AND WITH 2.7 Meter 20 810.43
METER GI PIPE OF 100MM SIZE AS PER SITE
CONDITION AND INSTRUCTION OF ENGINEER
IN CHARGE(RATES ARE INCLUDING COST OF
CLAMP AND GI PIPE).
LAYING OF VARIOUS SIZE OF 11KV XLPE
INSULATED ALUMINIUM ARMOURED CABLE
ABOVE GROUND IN AIR FOR TERMINATION
OF CABLE ON POLE WITH CLAMPS MADE
8 FROM GI FLAT 50X6 MM FOR AND WITH 2.7 Meter 20 1133.04
METER GI PIPE OF 160MM SIZE AS PER SITE
CONDITION AND INSTRUCTION OF ENGINEER
IN CHARGE(RATES ARE INCLUDING COST OF
CLAMP AND GI PIPE).
LAYING OF VARIOUS SIZE OF 11KV XLPE
INSULATED ALUMINIUM ARMOURED CABLE
ABOVE GROUND IN AIR FOR TERMINATION
9 OF CABLE ON POLE AS PER SITE CONDITION Meter 20 46.08
AND INSTRUCTION OF ENGINER IN CHARGE(
THE RATES ARE EXCLUDING COST OF CLAMP
LAYING OF VARIOUS SIZE OF 11KV XLPE
INSULATED ALUMINIUM ARMOURED CABLE
UNDERGROUND THROUGH ALREADY LAID
HDPE PIPE (BY HDD METHOD)(THE RATES ARE
EXCLUDING SUPPLY AND LAYING OF HDPE
PIPE THROUGH HDD METHOD)
LAYING OF VARIOUS SIZE SINGLE CIRCUIT OF
11KV XLPE INSULATED ALUMINIUM
11 ARMOURED CABLE IN CABLE TRENCH UPTO Meter 20 280.86
THE MINIMUM DEPTH OF 1200MM IS TO BE
DUG WITH WIDTH OF 300MM IN ANY TYPE
Signature of Tenderer Company’s Round Seal Page 3 of
Place: Signature of Tenderer Date:
Save Energy for Benefit of Self and Nation
OF SOIL. SPREADING OF SAND AT BOTTOM
OF THE TRENCH UPTO 100MM BEFORE LYING
OF HDPE PIPE IN THE CENTRE OF THE
TRENCH. UTMOST CARE SHOULD BE TAKEN
WHILE LOADING/UNLOADING AND
UNWINDING THE CABLE DRUMS. THE CABLE
SHALL BE LAID THROUGH PARTICULAR SIZE
OF HDPE PIPE. BEFORE REFILLING PRE-
BONDING TAP/WARNING TAP SHOULD
PROVIDE BELOW 700MM FROM THE
GROUND LEVEL AND BACK FILING THE SAME
TO MAKE GROUND LEVEL AS PER ORIGINAL.
BACK FEELING THE TRENCH SO AS TO MAKE
GROUND LEVEL AS PER ORIGINAL. LAID
CABLE UPTO CABLE BOX OF PLINTH
MOUNTED RMU/ TRANSFORMER SHALL BE
PART OF NORMAL LAYING.(THE RATES ARE
EXCLUDING SUPPLY OF HDPE PIPE)
LAYING OF VARIOUS SIZE DOUBLE CIRCUIT OF
11KV XLPE INSULATED ALUMINIUM
ARMOURED CABLE IN CABLE TRENCH UPTO
THE MINIMUM DEPTH OF 1200MM IS TO BE
DUG WITH WIDTH OF 300MM IN ANY TYPE
OF SOIL. SPREADING OF SAND AT BOTTOM
OF THE TRENCH UPTO 100MM BEFORE LYING
OF HDPE PIPE IN THE CENTRE OF THE
TRENCH. UTMOST CARE SHOULD BE TAKEN
WHILE LOADING/UNLOADING AND
UNWINDING THE CABLE DRUMS. THE CABLE
12 SHALL BE LAID THROUGH PARTICULAR SIZE Meter 20 439.13
OF HDPE PIPE. BEFORE REFILLING PRE-
BONDING TAP/WARNING TAP SHOULD
PROVIDE BELOW 700MM FROM THE
GROUND LEVEL AND BACK FILING THE SAME
TO MAKE GROUND LEVEL AS PER ORIGINAL.
BACK FEELING THE TRENCH SO AS TO MAKE
GROUND LEVEL AS PER ORIGINAL. LAID
CABLE UPTO CABLE BOX OF PLINTH
MOUNTED RMU/ TRANSFORMER SHALL BE
PART OF NORMAL LAYING.(THE RATES ARE
EXCLUDING SUPPLY OF HDPE PIPE)
PUSH THROUGH: PROVIDING OF HDPE PIPE
CONFIRMING TO IS 4984:1955(AMENDMENT
NO. 2)FOR HT UG CABLE WITH OD 160MM
MINIMUM THICKNESS AS PER IS 4982 AND
AMENDMENT THEREOF(RATES ARE
EXCLUDING LAYING OF CABLE)
Signature of Tenderer Company’s Round Seal Page 4 of
Place: Signature of Tenderer Date:
Save Energy for Benefit of Self and Nation
PUSH THROUGH: PROVIDING OF HDPE PIPE
CONFIRMING TO IS 4984:1955(AMENDMENT
NO. 2)FOR HT UG CABLE WITH OD 140MM
MINIMUM THICKNESS AS PER IS 4982 AND
AMENDMENT THEREOF(RATES ARE
EXCLUDING LAYING OF CABLE)
PUSH THROUGH: PROVIDING OF HDPE PIPE
CONFIRMING TO IS 4984:1955(AMENDMENT
NO. 2)FOR HT UG CABLE WITH OD 125MM
MINIMUM THICKNESS AS PER IS 4982 AND
AMENDMENT THEREOF(RATES ARE
EXCLUDING LAYING OF CABLE)
PUSH THROUGH: PROVIDING OF HDPE PIPE
CONFIRMING TO IS 4984:1955(AMENDMENT
NO. 2)FOR HT UG CABLE WITH OD 110MM
MINIMUM THICKNESS AS PER IS 4982 AND
AMENDMENT THEREOF(RATES ARE
EXCLUDING LAYING OF CABLE)
PUSH THROUGH: PROVIDING OF HDPE PIPE
CONFIRMING TO IS 4984:1955(AMENDMENT
NO. 2)FOR HT UG CABLE WITH OD 90MM
MINIMUM THICKNESS AS PER IS 4982 AND
AMENDMENT THEREOF(RATES ARE
EXCLUDING LAYING OF CABLE)
PUSH THROUGH: LAYING OF HDPE PIPE
CONFIRMING TO IS 4984:1955(AMENDMENT
NO. 2)FOR HT UG CABLE WITH OD
18 160/140/125/110MM MINIMUM THICKNESS Meter 20 805.21
AS PER IS 4982 AND AMENDMENT
THEREOF(RATES ARE EXCLUDING LAYING OF
PUSH THROUGH: LAYING OF HDPE PIPE
CONFIRMING TO IS 4984:1955(AMENDMENT
NO. 2)FOR HT UG CABLE WITH OD 90MM
MINIMUM THICKNESS AS PER IS 4982 AND
AMENDMENT THEREOF(RATES ARE
EXCLUDING LAYING OF CABLE)
PROVIDING HT PUSH ON/HEAT SHRINK TYPE
END INDOOR TERMINATION KIT PREFERABLY
3M(M-SEAL) OR RAYCHEM MAKE AT
SWITCHGEAR END BOXES, TRANSFORMER
20 (PAD/POLE MOUNTED) FOR 11KV Number 20 4663.11
3CX95/120/150/185MM2 HT XLPE
ALUMINIUM CONDUCTOR ARMOURED CABLE
AS SPECIFIED WITH CONNECTION OF LEADS
INCLUDING CUTTING, STRIPPING OF CABLE,
Signature of Tenderer Company’s Round Seal Page 5 of
Place: Signature of Tenderer Date:
Save Energy for Benefit of Self and Nation
INSULATIONS, PROVIDING COMPRESSION
TYPE TERMINAL, CRIMPING OF LUGS WITH
SUITABLE CRIMPING TOOL, INDOOR
PROVIDING HT PUSH ON/HEAT SHRINK TYPE
END INDOOR TERMINATION KIT PREFERABLY
3M(M-SEAL) OR RAYCHEM MAKE AT
SWITCHGEAR END BOXES, TRANSFORMER
(PAD/POLE MOUNTED) FOR 11KV
3CX240MM2 HT XLPE ALUMINIUM
21 CONDUCTOR ARMOURED CABLE AS Number 20 5018.85
SPECIFIED WITH CONNECTION OF LEADS
INCLUDING CUTTING, STRIPPING OF CABLE,
INSULATIONS, PROVIDING COMPRESSION
TYPE TERMINAL, CRIMPING OF LUGS WITH
SUITABLE CRIMPING TOOL, INDOOR
PROVIDING HT PUSH ON/HEAT SHRINK TYPE
END INDOOR TERMINATION KIT PREFERABLY
3M(M-SEAL) OR RAYCHEM MAKE AT
SWITCHGEAR END BOXES, TRANSFORMER
(PAD/POLE MOUNTED) FOR 11KV
3CX300/400MM2 HT XLPE ALUMINIUM
22 CONDUCTOR ARMOURED CABLE AS Number 20 5372.95
SPECIFIED WITH CONNECTION OF LEADS
INCLUDING CUTTING, STRIPPING OF CABLE,
INSULATIONS, PROVIDING COMPRESSION
TYPE TERMINAL, CRIMPING OF LUGS WITH
SUITABLE CRIMPING TOOL, INDOOR
FIXING HT PUSH ON/HEAT SHRINK TYPE END
INDOOR TERMINATION KIT PREFERABLY
3M(M-SEAL) OR RAYCHEM MAKE AT
SWITCHGEAR END BOXES, TRANSFORMER
(PAD/POLE MOUNTED) FOR 11KV
23 XLPE ALUMINIUM CONDUCTOR ARMOURED Number 20 1490.43
CABLE AS SPECIFIED WITH CONNECTION OF
LEADS INCLUDING CUTTING, STRIPPING OF
CABLE, INSULATIONS, PROVIDING
COMPRESSION TYPE TERMINAL, CRIMPING
OF LUGS WITH SUITABLE CRIMPING TOOL,
INDOOR APPLICATION
Signature of Tenderer Company’s Round Seal Page 6 of
Place: Signature of Tenderer Date:
Save Energy for Benefit of Self and Nation
PROVIDING HT PUSH ON/HEAT SHRINK TYPE
END OUTDOOR TERMINATION KIT
PREFERABLY 3M(M-SEAL) OR RAYCHEM
MAKE AT SWITCHGEAR END BOXES,
TRANSFORMER (PAD/POLE MOUNTED) FOR
11KV 3CX95/120/150/185MM2 HT XLPE
24 ALUMINIUM CONDUCTOR ARMOURED CABLE Number 20 5895.9
AS SPECIFIED WITH CONNECTION OF LEADS
INCLUDING CUTTING, STRIPPING OF CABLE,
INSULATIONS, PROVIDING COMPRESSION
TYPE TERMINAL, CRIMPING OF LUGS WITH
SUITABLE CRIMPING TOOL, OUTDOOR
PROVIDING HT PUSH ON/HEAT SHRINK TYPE
END OUTDOOR TERMINATION KIT
PREFERABLY 3M(M-SEAL) OR RAYCHEM
MAKE AT SWITCHGEAR END BOXES,
TRANSFORMER (PAD/POLE MOUNTED) FOR
11KV 3CX240MM2 HT XLPE ALUMINIUM
25 CONDUCTOR ARMOURED CABLE AS Number 20 6360.65
SPECIFIED WITH CONNECTION OF LEADS
INCLUDING CUTTING, STRIPPING OF CABLE,
INSULATIONS, PROVIDING COMPRESSION
TYPE TERMINAL, CRIMPING OF LUGS WITH
SUITABLE CRIMPING TOOL, OUTDOOR
PROVIDING HT PUSH ON/HEAT SHRINK TYPE
END OUTDOOR TERMINATION KIT
PREFERABLY 3M(M-SEAL) OR RAYCHEM
MAKE AT SWITCHGEAR END BOXES,
TRANSFORMER (PAD/POLE MOUNTED) FOR
11KV 3CX300/400MM2 HT XLPE ALUMINIUM
26 CONDUCTOR ARMOURED CABLE AS Number 20 6716.39
SPECIFIED WITH CONNECTION OF LEADS
INCLUDING CUTTING, STRIPPING OF CABLE,
INSULATIONS, PROVIDING COMPRESSION
TYPE TERMINAL, CRIMPING OF LUGS WITH
SUITABLE CRIMPING TOOL, OUTDOOR
Signature of Tenderer Company’s Round Seal Page 7 of
Place: Signature of Tenderer Date:
Save Energy for Benefit of Self and Nation
FIXING HT PUSH ON/HEAT SHRINK TYPE END
OUTDOOR TERMINATION KIT PREFERABLY
3M(M-SEAL) OR RAYCHEM MAKE AT
SWITCHGEAR END BOXES, TRANSFORMER
(PAD/POLE MOUNTED) FOR 11KV
27 XLPE ALUMINIUM CONDUCTOR ARMOURED Number 20 1490.43
CABLE AS SPECIFIED WITH CONNECTION OF
LEADS INCLUDING CUTTING, STRIPPING OF
CABLE, INSULATIONS, PROVIDING
COMPRESSION TYPE TERMINAL, CRIMPING
OF LUGS WITH SUITABLE CRIMPING TOOL,
OUTDOOR APPLICATION
PROVIDING HT PUSH ON/HEAT SHRINK TYPE
STRAIGHT JOINT PREFERABLY 3M(M-SEAL) OR
RAYCHEM MAKE FOR 11KV
3CX95/120/150/185MM2 HT XLPE
ALUMINIUM CONDUCTOR ARMOURED CABLE
28 Number 20 7882.78
AS SPECIFIED WITH CONNECTION OF LEADS
INCLUDING CUTTING, STRIPPING OF CABLE,
INSULATIONS, PROVIDING COMPRESSION
TYPE TERMINAL, CRIMPING OF LUGS WITH
SUITABLE CRIMPING TOOL
PROVIDING HT PUSH ON/HEAT SHRINK TYPE
STRAIGHT JOINT PREFERABLY 3M(M-SEAL) OR
RAYCHEM MAKE FOR 11KV 3CX240MM2 HT
XLPE ALUMINIUM CONDUCTOR ARMOURED
29 CABLE AS SPECIFIED WITH CONNECTION OF Number 20 8150.81
LEADS INCLUDING CUTTING, STRIPPING OF
CABLE, INSULATIONS, PROVIDING
COMPRESSION TYPE TERMINAL, CRIMPING
OF LUGS WITH SUITABLE CRIMPING TOOL
PROVIDING HT PUSH ON/HEAT SHRINK TYPE
STRAIGHT JOINT PREFERABLY 3M(M-SEAL) OR
RAYCHEM MAKE FOR 11KV 3CX300/400MM2
HT XLPE ALUMINIUM CONDUCTOR
ARMOURED CABLE AS SPECIFIED WITH
30 Number 20 8341.8
CONNECTION OF LEADS INCLUDING CUTTING,
STRIPPING OF CABLE, INSULATIONS,
PROVIDING COMPRESSION TYPE TERMINAL,
CRIMPING OF LUGS WITH SUITABLE
FIXING HT PUSH ON/HEAT SHRINK TYPE
STRAIGHT JOINT PREFERABLY 3M(M-SEAL) OR
31 Number 20 1490.43
RAYCHEM MAKE FOR 11KV
Signature of Tenderer Company’s Round Seal Page 8 of
Place: Signature of Tenderer Date:
Save Energy for Benefit of Self and Nation
XLPE ALUMINIUM CONDUCTOR ARMOURED
CABLE AS SPECIFIED WITH CONNECTION OF
LEADS INCLUDING CUTTING, STRIPPING OF
CABLE, INSULATIONS, PROVIDING
COMPRESSION TYPE TERMINAL, CRIMPING
OF LUGS WITH SUITABLE CRIMPING TOOL
CARBON EARTHING FOR UG EQUIPMENT:
SUPPLYING OF MAINTENANCE FREE
EARTHING SYSTEM COMPRISING OF 17.2 MM
DIA 2 MTR LONG EARTHING ELECTRODE OF
LOW CARBON STEEL ELECTRODE WITH
32 MICRONS COPPER COATING+ CARBON BASED Number 20 6554.91
CONDUCTIVE CONCRETE BACK FILL SAFE
COMPOUND (RESISTIVITY OF LESS THAN
OHM MTR)& COPPER CLAMP, MAKING
100MM DIA BORE, 2 MTR LONG, MAKING OF
EARTHING PIT CHAMBER IN NORMAL SOIL
CARBON EARTHING FOR UG EQUIPMENT:
ERECTING OF MAINTENANCE FREE EARTHING
SYSTEM COMPRISING OF 17.2 MM DIA 2 MTR
LONG EARTHING ELECTRODE OF LOW
CARBON STEEL ELECTRODE WITH
33 MICRONS COPPER COATING+ CARBON BASED Number 20 1192.17
CONDUCTIVE CONCRETE BACK FILL SAFE
COMPOUND (RESISTIVITY OF LESS THAN
OHM MTR)& COPPER CLAMP, MAKING
100MM DIA BORE, 2 MTR LONG, MAKING OF
EARTHING PIT CHAMBER IN NORMAL SOIL
CARBON EARTHING FOR UG EQUIPMENT:
SUPPLYING OF MAINTENANCE FREE
EARTHING SYSTEM COMPRISING OF 17.2 MM
DIA 3 MTR LONG EARTHING ELECTRODE OF
LOW CARBON STEEL ELECTRODE WITH
34 MICRONS COPPER COATING+ CARBON BASED Number 20 7746.72
CONDUCTIVE CONCRETE BACK FILL SAFE
COMPOUND (RESISTIVITY OF LESS THAN
OHM MTR)& COPPER CLAMP, MAKING
100MM DIA BORE, 3 MTR LONG, MAKING OF
EARTHING PIT CHAMBER IN NORMAL SOIL
CARBON EARTHING FOR UG EQUIPMENT:
ERECTING OF MAINTENANCE FREE EARTHING
SYSTEM COMPRISING OF 17.2 MM DIA 3 MTR
LONG EARTHING ELECTRODE OF LOW
35 CARBON STEEL ELECTRODE WITH 250 Number 20 1192.17
MICRONS COPPER COATING+ CARBON BASED
CONDUCTIVE CONCRETE BACK FILL SAFE
COMPOUND (RESISTIVITY OF LESS THAN
OHM MTR)& COPPER CLAMP, MAKING
Signature of Tenderer Company’s Round Seal Page 9 of
Place: Signature of Tenderer Date:
Save Energy for Benefit of Self and Nation
100MM DIA BORE, 3 MTR LONG, MAKING OF
EARTHING PIT CHAMBER IN NORMAL SOIL
SUPPLY OF EARTHING CONDUCTOR 40X3 GI
STRIP FOR ALL ELECTRICAL EQUIPMENTS AS
36 WELL AS CONNECTION TO BE MADE TO THE Meter 20 164.75
EARTH PIT. RATES INCLUSIVE OF HOT DIPPED
INSTALLATION AND COMMISSIONING OF
EARTHING CONDUCTOR 40X3 GI STRIP FOR
ALL ELECTRICAL EQUIPMENTS AS WELL AS
37 Meter 20 62.6
CONNECTION TO BE MADE TO THE EARTH
PIT. RATES INCLUSIVE OF HOT DIPPED
SUPPLY OF EARTHING CONDUCTOR 36X3 GI
STRIP FOR POLE MOUNTED TRANSFORMER
AND UPTO FSP, RMU AS WELL AS
CONNECTION TO BE MADE TO THE EARTH
PIT. RATES INCLUSIVE OF HOT DIPPED
INSTALLATION AND COMMISSIONING OF
EARTHING CONDUCTOR 36X3 GI STRIP FOR
POLE MOUNTED TRANSFORMER AND UPTO
39 Meter 20 62.6
FSP, RMU AS WELL AS CONNECTION TO BE
MADE TO THE EARTH PIT. RATES INCLUSIVE
OF HOT DIPPED HARDWARES.
SUPPLY OF EARTHING CONDUCTOR 25X3 GI
STRIP FOR POLE MOUNTED TRANSFORMER
AND UPTO FSP, RMU AS WELL AS
CONNECTION TO BE MADE TO THE EARTH
PIT. RATES INCLUSIVE OF HOT DIPPED
INSTALLATION AND COMMISSIONING OF
EARTHING CONDUCTOR 25X3 GI STRIP FOR
POLE MOUNTED TRANSFORMER AND UPTO
41 Meter 20 62.6
FSP, RMU AS WELL AS CONNECTION TO BE
MADE TO THE EARTH PIT. RATES INCLUSIVE
OF HOT DIPPED HARDWARES.
WARNING TAP: FOR LAYING ON TRENCH
AFTER LAYING CABLE ON TRENCH TO
PROVIDE INDICATION CABLE ROUTE BELOW
LAND SURFACE IN UNDERGROUND TRENCH
TO PROTECT CABLE FOR MECHANICAL
CABLE TERMINAL FERRULS: THE PVC CABLE
43 Number 20 33.28
TERMINAL FERRULS FOR IDENTIFICATION OF
Signature of Tenderer Company’s Round Seal Page 10 of
Place: Signature of Tenderer Date:
Save Energy for Benefit of Self and Nation
PHASE SEQUENCE AND FEEDER/PSS/FSP
NAME OF HT/LT CABLES SHALL BE PROVIDED
AT EVERY TERMINATION OF ALL CABLES
STATING DETAIL AS UNDER. HT CABLE:
FEEDER NAME/PHASE(R/Y/B) LT
CABLE:TC/FSP NAME/PHASE(R/Y/B/N)
CABLE TAG: THE PVC TAG FOR
IDENTIFICATION OF FEEDER/PSS/FSP/RMU
NAME OF HT/LT CABLES SHALL BE PROVIDED
44 Number 20 33.28
AT EVERY 10 MTR HT FEEDER:
SUBSTATION/FEEDER LT
FEEDER:PSS/TRANSFORMER/FSP
PROVIDING OF ROUTE MARKER OF CC 1:2:4,
150MM*150MM*750MM CONCRETE STONE
EMBEDDED IN EARTH ATLEAST 300MM
BELOW THE GL AND 450MM ABOVE GL AT
DISTANCE OF APPROXIMATELY 100MTR OR
AS DIRECTED BY ENGINEER IN CHARGE. THE
45 Number 20 358.2
ROUTE MARKER MUST BE PAINTED WITH
YELOOW COLOR OF STONE WITH RED COLOR
EMBRACING ON STONE-'UGVCL 11KV
CABLE'/'UGVCL 1.1KV CABLE'.(THIS INCLUDES
MATERIAL, CHARGES FOR EXCLAVATION &
FIXING OF ROUTE MARKER OF CC 1:2:4,
150MM*150MM*750MM CONCRETE STONE
EMBEDDED IN EARTH ATLEAST 300MM
BELOW THE GL AND 450MM ABOVE GL AT
DISTANCE OF APPROXIMATELY 100MTR OR
AS DIRECTED BY ENGINEER IN CHARGE. THE
46 Number 20 120
ROUTE MARKER MUST BE PAINTED WITH
YELOOW COLOR OF STONE WITH RED COLOR
EMBRACING ON STONE-'UGVCL 11KV
CABLE'/'UGVCL 1.1KV CABLE'.(THIS INCLUDES
PAINTING & LABOUR CHARGES FOR
EXCLAVATION & REFILLING)
SUPPLY OF CLAMPS MADE FROM 50*6MM GI
FLAT (MIN WEIGHT OF FLAT 1.6KG PER SET)
47 FOR FITTING FOR 110MM GI/HDPE PIPE Set 20 119.7
ABOVE GROUND WITH THE POLE( WITH COST
OF NUTS & BOLTS)
INSTALLATION OF CLAMPS MADE FROM
50*6MM GI FLAT (MIN WEIGHT OF FLAT
48 1.6KG PER SET) FOR FITTING FOR 110MM Set 20 36.52
GI/HDPE PIPE ABOVE GROUND WITH THE
POLE( WITH COST OF NUTS & BOLTS)
Signature of Tenderer Company’s Round Seal Page 11 of
Place: Signature of Tenderer Date:
Save Energy for Benefit of Self and Nation
SUPPLY OF CLAMPS MADE FROM 50*6MM GI
49 FLAT (MIN WEIGHT OF FLAT 1.8KG PER SET) Set 20 143.4
FOR FITTING FOR 160MM GI/HDPE PIPE
ABOVE GROUND WITH THE POLE( WITH COST
OF NUTS & BOLTS)
INSTALLATION OF CLAMPS MADE FROM
50*6MM GI FLAT (MIN WEIGHT OF FLAT
50 1.8KG PER SET) FOR FITTING FOR 160MM Set 20 36.52
GI/HDPE PIPE ABOVE GROUND WITH THE
POLE( WITH COST OF NUTS & BOLTS)
SUPPLY OF MEDIUM GRADE GI PIPE OF SIZE
51 OF 100MM DIAMETER(MIN 2.5 METER Meter 20 417.2
REQUIRED) WEIGHT 9 TO 10 KG/MTR
FIXING OF MEDIUM GRADE GI PIPE OF SIZE
52 OF 100MM DIAMETER(MIN 2.5 METER Meter 20 239.1
REQUIRED) WEIGHT 9 TO 10 KG/MTR
SUPPLY OF MEDIUM GRADE GI PIPE OF SIZE
53 OF 160MM DIAMETER(MIN 2.5 METER Meter 20 715.6
REQUIRED) WEIGHT 10 TO 11 KG/MTR
FIXING OF MEDIUM GRADE GI PIPE OF SIZE
54 OF 160MM DIAMETER(MIN 2.5 METER Meter 20 239.1
REQUIRED) WEIGHT 10 TO 11 KG/MTR
SHIFTING OF RING MAIN UNIT (IRRESPECTIVE
55 OF CONFIGURATION OF RMU & INCLUSIVE OF Number 10 60334.78
EARTHING AND CHAIN LINK FENCING)
SHIFTING OF DISTRIBUTION TRANSFORMER
56 (IRRESPECTIVE OF KVA RATING & UPTO Number 1 145655.65
500KVA & INCLUSIVE OF EARTHING AND
CHAIN LINK FENCING)
57 SHIFTING OF DISTRIBUTION FEEDER PILLAR Number 9 29864.35
SUITABLE FOR OUTDOOR INSTALLATION
REPLACEMENT OF RMU(IRRESPECTIVE OF
CONFIGURATION): EXISTING RMU SHALL BE
DISMENTALED AND NEW RMU SHALL BE
INSTALLED. EXISTING RMU SHALL BE
58 Number 2 10547.83
SUBMITTED TO UGVCL STORE AS PER
INSTRUCTION OF ENGINEER IN CHARGE,
TERMINATION, EARTHING, ETC SHALL BE
BILLED SEPERATELY.
REPLACEMENT OF TRANSFORMER
(IRRESPECTIVE OF KVA RATING):EXISTING
59 TRANSFORMER WITH CABLE BOX SHALL BE Number 15 7911.3
DISMENTALED AND NEW TRANSFORMER
WITH CABLE BOX SHALL BE INSTALLED.
Signature of Tenderer Company’s Round Seal Page 12 of
Place: Signature of Tenderer Date:
Save Energy for Benefit of Self and Nation
EXISTING TRANSFORMER WITH CABLE BOX
SHALL BE SUBMITTED TO UGVCL STORE AS
PER INSTRUCTION OF ENGINEER IN CHARGE.
TERMINATION, EARTHING, ETC SHALL BE
BILLED SEPERATELY.
ROAD RESTORATION CHARGES FOR PUCCA
60 ROAD CROSSING/ FOORPATH(LS)(THE RATES Meter 10 1192.17
ARE INCLUDING COST OF MATERIAL)
RESURFACING OF EXISTING ROAD,
FOOTPATH, ETC AS IT WAS IN CONDITION PIT
61 Number 10 596.52
SIZE (600MMX1000MM)(RATES ARE
INCLUDING COST OF MATERIAL)
CONSTRUCTION OF PLINTH AND
62 Number 1 11918.26
FOUNDATION OF FUSE SECTION PILLAR
CONSTRUCTION OF PLINTH AND
63 Number 1 11918.26
FOUNDATION OF MINI SECTION PILLAR
CONSTRUCTION OF RMU PLINTH( UPTO
64 WAY):2.50X2.00X0.55 METER ABOVE Number 1 36164.34
CONSTRUCTION OF RMU PLINTH( ABOVE
65 WAY):3.00X2.00X0.55 METER ABOVE Number 1 40167.83
CONSTRUCTION OF DISTRIBUTION
66 Number 1 65897.13
TRANSFORMER PLINTH UPTO 500KVA
EXTENSION OF EXISTING PLINTH:
67 CONSTRUCTION OF RMU PLINTH (EXTENSION Number 1 10535.65
68 INSTALLATION, TESTING AND Number 1 5273.72
COMMISSIONING OF RING MAIN UNIT
INSTALLATION, TESTING AND
69 Number 15 1191.8
COMMISSIONING OF EARTHING
INSTALLATION, TESTING AND
70 Number 20 5273.72
COMMISSIONING OF TRANSFORMER
LAYING OF HDPE PIPE CONFIRMING TO IS
4984:1955 (AMENDMENT NO. 2) HAVING
VARIOUS SIZES AND MINIMUM THICKNESS AS
PER IS AT A MINIMUM DEPTH OF 1200MM
71 BELOW ROAD SURFACE BY PUSH THROUGH Meter 11 675
METHOD, DRILLING THE ROAD WITH HDD
MACHINE/MANUALLY WITHOUT BREAKING
THE ROAD SURFACE AS PER INSTRUCTION OF
EIC AND SPECIFICATIONS
PROVIDING OF 110MM DIAMETER HDPE PIPE
72 CONFIRMING TO IS 4984:1955 (AMENDMENT Meter 11 525
LABOUR WORK FOR 11 KV XLPE 185MM2
73 Number 18 15000
UNDERGROUNG CABLE FAULT DETECTION
Signature of Tenderer Company’s Round Seal Page 13 of
Place: Signature of Tenderer Date:
Save Energy for Benefit of Self and Nation
WITH LATEST TECHNOLOGY AND
SPECIFICATION BY ENGINEER
PIPE TYPE EARTHING HAVING 150CMS LONG
AND 2.5CMS DIA. GALVANISED IRON PIPE
74 WITH COUPLING AND BUCH BURIED IN Meter 50 2200
SPECIALLY PREPARED EARTH PIT COMPLETE
WITH NECESSARY 8 SWG EARTH WIRE.
REMOVAL OF EXISTING 11KV XLPE CABLE
75 WITH DIGGING OF PIT AND LAYING OLD HT Meter 104 168
76 Welfare Cess @ 1% of Estimated Cost Each 1 37757.75
77 GST@18% (If applicable) Each 1 686435.86
(b) Bidder’s Offer (+ / -) in %
(c) Grand Total C = A +/- (A x B)
(c) Grand Total C = A +/- (A x B)
Goods & Service Tax D = C x GST %
(GST Rate :______%)
Grand Total including GST [ E = C + D
Grand Total including GST [ E = C + D
Final Offer (in Rs.):
Final Offer (in Words):
I / We am /are willing to carry out the work LAYING OF UNDERGROUND CABLE under Sidhpur DO
(1) On company Rate (2.) _______% Above 3) _______% Below of estimated rate
(1) In case of L1 bidder backs out from tender process before allotment of order or during tender
process, UGVCL has right to call next lowest bidder/bidders to execute work at least as per L1
(2) Quantity which mentioned in Schedule – B is tentative and it may vary as per field office
Executive Engineer
UGVCL SIDHPUR DO
Signature of Tenderer Company’s Round Seal Page 14 of
Place: Signature of Tenderer Date:
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
RAW_HTML
E-Tender Notice-UGVCL-SIDH-DO-10-2026-27 SNR 02.pdf
E-Tender Notice-UGVCL-SIDH-DO-10-2026-27.pdf
SNR-02 SIDH-DO-10-2026-27 (UG Reference Bid Drawing).pdf
SNR-02 SIDH-DO-10-2026-27 (UG Bid Document).pdf
SNR-02 SIDH-DO-10-2026-27 (UG Schedule B).pdf
SNR-02 SIDH-DO-10-2026-27 (UG Detail Technical Specification).pdf
SNR-02 SIDH-DO-10-2026-27 (UG Schedule A).pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .