Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.7 LAccepted-AOC | L1 | Accepted-AOC since the lowest | |
| 2 | L2₹4.7 L+₹4,866.07 (1.04%)Rejected-Finance | L2 | Rejected-Finance MORE THAN THE LOWEST | |
| 3 | L3₹4.7 L+₹4,913.32 (1.05%)Rejected-Finance | L3 | Rejected-Finance MORE THAN THE LOWEST | |
| 4 | L3₹4.7 L+₹4,913.32 (1.05%)Rejected-Finance | L3 | Rejected-Finance MORE THAN THE LOWEST | |
| 5 | L4₹4.7 L+₹6,377.86 (1.36%)Rejected-Finance | L4 | Rejected-Finance MORE THAN THE LOWEST |
Tender Value
₹4.7 L
EMD Value
₹9,449
Closing Date
17 Jul 2026, 6:00 pmClosed
The Assistant Engineer, BNWSD-I, Purta Bhavan
The Assistant Engineer, BNWSD-I, Purta Bhavan, Room No. 125
Repair and Rehabilitation of inside distressed area of Addl. District Sub-Register Office within East Block under Bikash Bhavan, Salt Lake, Kolkata-91, during the year 2026-2027.
2026_WBPWD_5016426_1
AE/BNWSD-I/NIT-03e/2026-2027
Open Tender
CIVIL WORKS
Percentage
28 days
Purta Bhavan, Salt Lake, Sector-I, Kolkata-700091
Please refer Tender documents.
6 documents required · 6 mandatory
₹9,449
Yes
28 Jul 2026
7 Jul 2026
20 Jul 2026
8 Jul 2026
17 Jul 2026
8 Jul 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Stripping off worn out plaster and raking out
joints of walls, celings etc. upto any height and in
any floor including removing rubbish within a
lead of 75m as directed. | - | Sq.M. | 22.64 | - |
| 2 | Removal of rubbish,earth etc. from the working
site and disposal of the same beyond the
compound, in conformity with the Municipal /
Corporation Rules for such disposal, loading into
truck and cleaning the site in all respect as per
direction of Engineer in charge | - | Cu.M. | 197.84 | - |
| 3 | Cleaning the concrete surface by removing dirt and debris, marking defective locations and removing loose concrete by careful stripping untill hard surface is exposed, cutting the concrete to regular shape, wire brushing the exposed surface and removing debris from site complete as per direction of the Engineer - in - Charge | - | Sq.M. | 107.26 | - |
| 4 | Cleaning the exposed reinforcement preferably upto full diameter by wire brush, applying two coats of polymer based rust removing compound left for 24 hours, removing the coating and then applying two (2) coats of polymer modified anti corrosive protective coating formulated to inhibit the corrosion of reinforcement as per manufacturer's specification] [Mode of measurement:The affected surface area of reinforcement shall be considered for payment] | - | Sq.M. | 931.99 | - |
| 5 | Removing corroded worn out portion of reinforcement (when the area of bar is damaged by more than 25%) by cutting and replacing the same by a new plain round bar of requisite diameter by binding with required lap / welding with old bar, including cost of reinforcement, complete in all respect including removing unserviceable materials from site as per direction of the
Engineer - in - charge. Note : Payment on weight (Kg.) of new
reinforcement | - | Kg | 103.69 | - |
| 6 | Applying epoxy based reactive joining agent for joining the old concrete with fresh concrete to be applied within manufacturer's specified time as per manufacturers specification. (0.4 Kg / m² of concrete surface). | - | Sq.M. | 368.27 | - |
| 7 | Guniting concrete surface with cement mortar ( 25mmnominal thick) applied with compressor after cleaning surface and spraying with epoxy complete asper Technical specification | - | Sq.M. | 1,086.92 | - |
| 8 | Supplying preparing and placement of ready mix non shrink cementious microconcrete having no metalic aggregate or chlorides for repairing and iackting of damaged R.C.C members. Themicro concrete should achieve a compressive strength | - | Cu.M. | 60,240.72 | - |
| 9 | Hire and labour charges for shuttering with centering and necessary staging upto 4 m using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams and columns, lintels curved or straight including fitting, fixing and striking out after completion of works (upto roof of ground floor) | - | Sq.M. | 439.77 | - |
| 10 | (a) Applying 2 coats of bonding agent with synthetic multi functional rubber emulsion having adhesive and water proofing properties by mixing with water in proportion (1 bonding agent : 4 water : 6 cement) as per Manufacturer's specification [Cement to be supplied by the Department] | - | Sq.M. | 104.88 | - |
stage.html
html • 0.15 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.44 MB
Tendernotice_2.pdf
PDF • 1.27 MB
BOQ_5085918.xls
BOQ • 0.31 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .