| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹4.0 CrAccepted-Finance GOPIKA HOUSE KOTTAKUNNU SULTHAN BATHERY POST WAYANAD KERALA 673592 | WAYANAD | KERALA | 673592 | ₹4.0 Cr | 1 | Accepted-Finance Lowest Bidder |
| 2 | 2₹4.1 Cr+₹8.3 L (2.08%)Accepted-Finance | ₹4.1 Cr+₹8.3 L (2.08%) | 2 | Accepted-Finance Second Lowest |
| Sl No | Description | Qty | Unit | SHIJITH M L1 | saaj constructions L2 |
|---|---|---|---|---|---|
| 1.00SUBSTRUCTURE | |||||
| 1.00 | Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared | 2,000 | sqm | 16.97 ₹33,940 Lowest | 16.97 ₹33,940 Lowest |
| 1.00 | Felling trees of the girth (measured at a height of 1 m above ground level) including cutting of trunks and branches, removing the roots and stacking of serviceable material and disposal of unserviceable material.Beyond 120 cm girth up to and including 240 cm girth | 5 | each | 10,632.05 ₹53,160.25 Lowest | 10,632.05 ₹53,160.25 Lowest |
| 1.00 | Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil | 91.03 | cum | 335.74 ₹30,564.09 Lowest | 335.74 ₹30,564.09 Lowest |
| 1.00 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) | 298.28 | cum | 7,404.03 ₹22,08,459.26 Lowest | 7,404.03 ₹22,08,459.26 Lowest |
| 1.00 | Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete | 113.4 | sqm | 360.41 ₹40,870.49 Lowest | 360.41 ₹40,870.49 Lowest |
| 1.01 | Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers | 170.46 | sqm | 712.02 ₹1,21,370.93 Lowest | 712.02 ₹1,21,370.93 Lowest |
| 1.01 | Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more | 25,392.96 | kg | 104.93 ₹26,64,483.29 Lowest | 104.93 ₹26,64,483.29 Lowest |
| 1.01 | Providing and laying in position machine batched and machine mixed design mix M20 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge. Note: Cement content considered in this item is @ 330 kg/ cum. Excess or less cement used as per design mix is payable or recoverable separately. All work up to plinth level | 262.12 | cum | 10,163.59 ₹26,64,049.72 Lowest | 10,163.59 ₹26,64,049.72 Lowest |
| 1.01 | 12 mm cement plaster of mix:1:6 (1 cement : 6 fine sand). | 78.26 | sqm | 330.04 ₹25,830.25 Lowest | 330.04 ₹25,830.25 Lowest |
Tender Value
Refer Docs
EMD Value
₹1 L
Closing Date
26 Aug 2025, 1:30 pmClosed
General Manager and Senior Engineer
Habitat Technology group, Poojappura, Trivandrum
Construction of RDF Plant at KSIDC Valiyavelicham, Kannur for CKCL
2025_HTG_788241_1
HTG/CKCL/RDF/2025-26/02
Open Tender
Civil Works - Others
Item Rate
45 days
Valiyavelicham Kannur
Please refer Tender documents.
2 documents required · 2 mandatory
₹4,450
Yes
₹1 L
Yes
8 Oct 2025
19 Aug 2025
28 Aug 2025
19 Aug 2025
26 Aug 2025
19 Aug 2025
19 Aug 2025 - 25 Aug 2025
Amount
SUBSTRUCTURE
Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared
Felling trees of the girth (measured at a height of 1 m above ground level) including cutting of trunks and branches, removing the roots and stacking of serviceable material and disposal of unserviceable material.Beyond 120 cm girth up to and including 240 cm girth
Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources)
Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete
Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers
Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more
Providing and laying in position machine batched and machine mixed design mix M20 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge. Note: Cement content considered in this item is @ 330 kg/ cum. Excess or less cement used as per design mix is payable or recoverable separately. All work up to plinth level
12 mm cement plaster of mix:1:6 (1 cement : 6 fine sand).
Filling with contractor's own earth ( excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m as per direction of site Engineer-in-charge
SUPER STRUCTURE
Steel work in M.S tubular section (round, square or rectangular) trusses etc., including cutting, bending, hoisting, etc in curved and straight trusses and applying a priming coat of approved steel primer, including welding, bolting and bending with special shaped washers etc. complete.
Solid block masonry using pre cast solid blocks ( Factory made) of size 40x20x15cm or nearest available size confirming to IS 2185 part I of 1979 for foundation and plinth with thickness 15 cm in : CM 1:6 ( 1 cement : 6 coarse sand ) etc complete
12 mm cement plaster of mix:1:6 (1 cement : 6 fine sand).
Finishing walls with Acrylic Smooth exterior paint of required shade:New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)
Painting with synthetic enamel paint of approved brand and manufacture to give an even shade:Two or more coats on new work
Providing and fixing 1 mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer.Using M.S. angels 40x40x6 mm for diagonal braces
Providing and fixing weld mesh with 6 mm rod of required width in mesh size 50x50 mm complete as per the direction of Engineer-in- charge.
Providing corrugate G.S. sheet roofing including vertical/ curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete ( up to any pitch in horizontal / vertical or curved surfaces), excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.0.63 mm thick with zinc coating not less than 275 gm/m2
Providing and fixing 15cm wide, PVC sheet gutter with iron brackets 40x3 mm size, bolts, nuts and washers etc., including making necessary connections with rain water pipes complete.as per the direction of Engineer in charge
Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+0.05%), total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling/self tapping screws of size (5.5x55mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.
TOILET BLOCK
Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources)
Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) up to plinth level with:Cement mortar 1:6 (1 cement : 6 coarse sand)
Solid block masonry using pre cast solid blocks (Factory made) of size 40x20x15cm or nearest available size confirming to IS 2185 part I of 1979 for super structure up to floor two level with thickness 15cm in: CM 1:6 ( 1 cement : 6 coarse sand etc complete
Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers
Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete above plinth level.Thermo - Mechanically Treated bars of grade Fe-500D or more
Providing and laying in position machine batched and machine mixed design mix M20 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge. Note:- Cement content considered in this item is @ 330 kg/cum. Excess or less cement used as per design mix is payable or recoverable separately. All work above plinth level upto floor V level
12 mm cement plaster of mix:1:6 (1 cement : 6 fine sand).
Steel work in built up G I tubular ( round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting,fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete
Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface:Water thinnable cement primer
Finishing walls with Acrylic Smooth exterior paint of required shade:New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)
Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade:Two or more coats on new work
Painting with synthetic enamel paint of approved brand and manufacture to give an even shade:Two or more coats on new work
Providing and laying rectified Glazed Ceramic floor tiles of size 300x300 mm or more (thickness to be specified by the manufacturer) of Ist quality conforming to IS: 15622 of approved make in all colours, shades, except white, Ivory, Grey Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand) including pointing the joints with white cement and matching pigments etc., complete.
Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-inCharge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete..
Providing and fixing factory made P.V.C. door frame of size 50x47 mm with a wall thickness of 5 mm, made out of extruded 5 mm rigid PVC foam sheet, mitred at corners and joined with 2 Nos. of 150 mm long brackets of 15x15 mm M.S. square tube, the vertical door frame profiles to be reinforced with 19x19 mm M.S. square tube of 19 gauge, EPDM rubber gasket weather seal to be provided through out the frame. The door fame to be fixed to the wall using M.S. screws of 65/100 mm size, complete as per manufacturer's specification and direction of Engineer-in Charge.
Providing and fixing factory made panel PVC door shutter consisting of frame made out of M.S. tubes of 19 gauge thickness and sized of 19 mm x 19 mm for styles and 15x15 mm for top & bottom rails. M.S. frame shall have a coat of steel primers of approved make and manufacture. M.S. frame covered with 5 mm thick heat moulded PVC 'C' channel of size 30 mm thickness, 70 mm width out of whicj 50 mm shall be flat and 20 mm shall be tapered in 45 degree angle on both side forming styles and 5mm thick, 95 mm wide PVC sheet out of which75 mm shall be tapered in 45 degree on th inner side to form top and bottom rail and 115 mm wide PVC sheet out of which 75 mm shall be flat and 20 mm shall be tapered on both sides to form lock rail. Top, bottom and lock rails shall be provided both side of the panel. 10 mm (5 mmx2) thick, 20 mm wide cross PVC sheet be provided as gap insert for top rail & bottom rail. paneling of 5 mm thick both side PVC sheet to be fitted in the M.S. frame welded /sealed to the styles & rails with 7 mm (5 mm + 2 mm ) thick x 15 mm wide PVC sheet beading on inner side, and joined together with solvent cement adhesive. An additional 5 mm thick PVC strip of 20 mm width is to be stuck on the interior side of the 'C' Channel using PVC solvent adhesive etc. complete as per direction of Engineer -in-charge, manufacture's specification & drawing.30 mm thick plain PVC door shutters
Providing and fixing angle iron frames for doors, windows and ventilators of mild steel Angle sections of size 35x35x5 mm, joints mitred and welded by angle iron 35x35x5 mm or 35x 5 mm flat pieces to the existing T-iron frame or to the wall with dash fastener, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer, all complete as per the direction of Engineer In charge.
Providing and fixing M.S. Grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete.Fixed to steel windows by welding
Providing corrugate G.S. sheet roofing including vertical/ curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete ( up to any pitch in horizontal / vertical or curved surfaces), excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.0.80 mm thick with zinc coating less than 275 gm/m2
PLUMBING
Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required:W.C. pan with ISI marked black solid plastic seat and lid
Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:White Vitreous China Wash basin size 630 x 450 mm with a single 15 mm C.P. brass pillar tap
Providing and fixing white vitreous china laboratory sink including making all connections excluding cost of fittings:Size 450x300x150 mm
Providing and fixing mirror of superior glass ( of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing :Rectangular shape 453x357 mm
Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gm
Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fitting arrangement of approved quality and colour450 mm long towel rail with total length of 495 mm, 78 mm wide and effective height of 88 mm. weighing not less than 170 gms
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings. This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching , refilling & testing of joints complete as per direction of Engineer- in-Charge. External work20 mm nominal dia pipes
Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms.15 mm nominal bor
Providing and fixing C.P brass stop cock ( concealed) of standard design and of approved make conforming to IS: 893115 mm nominal bor
Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS: 893115 mm nominal bore
Providing and fixing PVC pipes includings of pipes with one step PVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 20 mm dia 10 Kgf/cm2
Providing and fixing PVC pipes includings of pipes with one step PVC solvent cement, trenching and refilling & testing of joints complete as per direction of Engineer in Charge. 75 mm dia 4 Kgf/cm2
Providing and fixing PVC pipes includes joints of pipes with one step PVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in CHarge. 110 mm dia 4 Kg/cm2
Providing and fixing PVC pipes including fixing the pipe with clamps/Clips at 1.00 m spacing. This included jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 75 mm dia 4 Kfg/cm2 External work - Exposed on wall
Providing and fixing PVC pipes including fixing the pipe with clamps/clips at 1.00 m spacing. This includes jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 110 m dia 4 Kgf/cm2 External work - Exposed on wall
Supplying and fixing CP Health faucet good quality including cost of materials and labour charges etc. complete as per the direction of site engineer-in-charge
Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 32 mm dia 10Kgf/cm2- Internal work - Exposed on wall
Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes with one step PVC Solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc. 110 mm pipe 4 kgf/cm2
Providing and fixing PVC moulded fittings/accessories for Rigid PVC pipes, including jointing with PVC solvent cement -110 mm dia End Cap
Providing and fixing PVC moulded fittings/accessories for Rigid PVC pipes,including jointing with PVC solvent cement - 110 mm dia Socket/ coupling
Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes including jointing with PVC solvent cement 110x110x110 mm dia Tee
Providing and fixing PVC moulded fittings/accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 110x110x110 mm dia Door tee
Providing and fixing PVC moulded fittings /accessories for Rigid PVC pipes, including jointing with PVC solvent cement -110 mm dia Vent cowl
Providing and fixing PVC pipes, fittings, including fixing the pipe with clamps at 1.00 m spacing. this includes jointing of pipes with one step PVC solvent cement and testing of joints complete as per the direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc. 75 mm pipe 4 kgf/cm2
Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 75 mm dia Bend
Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 75 mm dia Socket /coupling
Providing and placing on terrace (at all floor levels) polyethylene water storage tank :ISI 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank
SEPTIC TANK
Supplying and installing Septic tank of height 3m including the RCC cover of required size and thickness 12 mm, cost of carriage, trenching, placing at the level below ground level as specified as per the direction of engineer in charge
Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand) with R.C.C. top with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix ( 1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size,) inside plastering 12 mm thick with cement mortar 1:3 ( 1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ) finished with a floating coat of neat cement complete as per standard design: Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover and frame to be not less than 38 kg (weigh of cover 23 kg and weight of frame 15 kg):With Sewer bricks conforming to IS : 4885
OVERHEAD TANK
providing and fixing stainless steel Overhead tank of 20000 ltr including all material cost, labour, et
Wiring and Related Works
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.Group C
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2x1.5 sq.mm + 1x1.5 sq.mm earth wire
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2 X 4 sq. mm + 1 X 4 sq. mm earth wire
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.32 mm
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 amps switch
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.15/16 amp switch
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.3 pin 5/6 amp socket outlet
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.6 pin 15/16 amp socket outlet
Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.
Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.1 or 2 Module
Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.3 Module
Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.6 Module
Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required.
Supplying and fixing PVC batten/ angle holder including connection etc. as required.
Spply and Installation of IP 66/67 Thermoplastic Polycarbonate PC - GFS Junction Box with knockouts for cable entries for unprotected outdoor (UV resistance) The junction box shall fulfill the following standards 60670-22 Cable Junction Box Size: 104 x 104 x 70mm Make- Hensel KF 0400 B
DB AND ACCESSORIES
Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, ""C"" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole
Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, ""C"" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Triple pole
Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, ""C"" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Double pole
Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.
Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 milli Amperes in the existing MCB DB complete with connections, testing and commissioning etc. as required. 25 amps
Supplying and fixing TP sheet steel enclosure on surface/ recess along with 16/25/32amps 415 volts "C" curve TP MCB complete with connections, testing and commissioning etc. as required.
Supplying and fixing 30 amps, 415 volts, TPN industrial type, socket outlet, with 4 pole and earth, metal enclosed plug top alongwith 30 amps "C" curve, TPMCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface / recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)4 Way (4+12) Double
Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 volts, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 amps tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCB's (but without MCB's and incomer ) as required .(Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.)4 WAY(4+12), DOUBLE DOOR
Supply and Fixing 25/32 A FP MCB isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required
Electrical Fittings
Supply Conveyance, installation, testing and commissioning of 200W LED Flood light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing, acrylic cover complete with THD less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer)
Supply Conveyance, installation, testing and commissioning of 40W LED Flood light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing, acrylic cover complete with THD less than10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer)
Supply Conveyance, installation, testing and commissioning of 70W LED Flood light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing, acrylic cover complete with THD less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer)
Supply and Installation of 20 W LED Batten 6500K working on 240 V AC supply including giving connection etc complete
Supply Installation testing and commissioning of 450 mm sweep, 1400 rpm Heavy Duty Exhaust fan working on 230 V A/C in the existing opening making good the damages giving connection etc complete
Supply conveyance, installation, testing and commissioning of 450 mm sweep Heavy duty wall mounting fan / Air circulator for 230V/240V single phase AC supply etc. complete as required
Supply & Providing 9 W LED Bulb cool day light, colour temprature 6500 K, 810 lumen output with B22 base, working on 230 V AC supply
Supply, Installation, Testing and commissioning of 150 mm sweep Light Duty Exhaust fan in plastic body with self opening lowers working on 230V single phase A/
Electrical Power Works
Supply, Laying, testing and commissioning of XLPE cable of 11KV Earthed grade aluminium conductor, screened, XLPE insulated, armoured and PVC sheathed cable conforming to IS: 7098 through excavated trenches, built up cables trenches, cables trays. Hume pipe etc. 3C x300 Sqmm
Supply and making HV XLPE outdoor cable end termination as per equirement of Electricity board and as shown on drawings, schematics, specifications including heat shrinkable type endsealing kit of approved make and quality with all required accessories, etc. as required and complying to specifications and standards. etc.. 3x300 Sqmm outdoor cable end terminatio
Supply and making HV XLPE indoor cable end termination as per requirement of Electricity board and as shown on drawings, schematics, specifications including heat shrinkable type endsealing kit of approved make and quality with all requiredaccessories, etc. as required and complying to specifications and standards. etc.. 3x300 Sqmm indoor cable end termination
Supply and providing approved type of concrete cable route markers for HT cable concrete cable route markers for HT cable
Supply Installation Testing and Commissioning of 11kKV 630A, 21kA SF6 Insulated Outdoor Motorized Extensible 1 Way Consisting 12 VCB RMU Type SABRA - VCE for coupling with existing RMU
11KV/433V, 500KVA Cast Resin Transformer – Indoor Manufacturing and Supply of 11kV/433V, 500KVA, 50Hz,3phase, Vector Dyn 11 Resin Cast Indoor type Transformer with off circuit tapping +5% to -5% in steps of 2.5% with winding temperature indicator and hooter, LV side Cable box and HV terminal connected 11kv VCB Panel. 11KV VCB Panel with HT Metering - Indoor Manufacturing and Supply of Indoor type 11kV, 630A, 26.3kA for 3 sec Horizontal Draw out VCB fitted with Manual/Motor operated spring charging mechanism with 230V AC motor and motor control switch, shunt trip coil of 24V DC, closing coil of 24V DC, Auxiliary Contact 2NO + 2NC, Mechanical ON/OFF indicator, mechanical operation counter, protection CT, (--/5A, 5P10,15VA, 11kV/110V, Cl-0.2, 25VA PT Instantaneous IDMT relay with Microprocessor based 3O/C + and 1EF Protection relay, Strip Heater with thermostat, Digital Ammeter and Digital Voltmeter, Power pack 230V AC-24 V DC emergency OFF push button with HT Metering (3nos CT & 1 no PT Unit ) Provision for TOD Meter. 11KV/433V, 500KVA Cast Resin Transformer
Supply, Installation, testing and commissioning of easily detachable neutral link fabricated out of 50x6mm tinned GI strip of minimum length 150mm suitably bolted at both end and inserted in the neutral earthing conductor from the transformer bushing
Supply, Installation, testing and commissioning of emergency isolation push button mounted in standard I.P 65 weather proof break glass enclosure to isolate the power Supplying to the building in case of emergency when the face glass is broken. The push button shall be connected to the trip coil of the 11 kV LB SFU using 1.5 sq.mm 2 core copper cable.
Supply, Installation of neutral CT of ratio 150/5A, class 5P10 15VA of accuracy for earth fault relay in a metallic enclosure including control wiring from the transformer.NEUTRAL CT
Installation of 1 Nos. 500 KVA DG set prime rated with acoustic enclosure and Control panel, protection and digital metering, controls, interlocks and suitable FP MCCB, etc. @ 1500 rpm coupled to alternator with radiator, skid mounted, standard duty air intake system, External silencer, sound enclosure as per CPCB 2 norms, oil drain extension, battery with cables &lifting facility. Installation of 1 Nos. 500 KVA DG
Supply, Installation of neutral CT of ratio 150/5A, class 5P10 15VA of accuracy for earth fault relay in a metallic enclosure including control wiring from the DG NEUTRAL CT
Supply and Providing 6mm thick MS Class-B exhaust piping for DG sets as per CPCB/KPCB norms including necessary foundations, supporting steel structure flanges, bends, necessary thermal insulation using 75mm thick mineral wool (density 150kg/cum), insulation wrapped in chicken mesh and clad with 24G aluminum sheet including all support structural as required. The exhaust pipes shall be provided with spring isolators or bellows to avoid transmission of vibration, canopy, and shall be extendedabove 1.8m above finished roof level. 200mm dia EXHAUST PIPING for dg
Supply and Providing 6mm thick MS Class-B exhaust piping for DG sets as per CPCB/KPCB norms including necessary foundations, supporting steel structure flanges, bends, necessary thermal insulation using 75mm thick mineral wool (density 150kg/cum), insulation wrapped in chicken mesh and clad with 24G aluminum sheet including all support structural as required. The exhaust pipes shall be provided with spring isolators or bellows to avoid transmission of vibration, canopy, and shall be extendedabove 1.8m above finished roof level. 250mm di EXHAUST PIPING FOR DG
Supplying, Conveyance, Installation, Testing and Commissioning of Self supported, free standing powder coated cubicle type Main switchboards, fabricated out of CRCA components, chemically treated and powder coated with approved shade. The panel construction with cable entry facility at bottom, cable alley, switchgear compartment, meter chamber, C.Tchamber, busbarchamber etc. shall be fully segregated and compartmentalized. Shrouding of live parts shall be with 3 mm FRP and two fastener screws and chamber partition at dropper connection with 6 mm FRP Control wiring shall be with 2.5 sq.mm copper cables of 1100 volts grad for C.T leads and 1.5 sq.mm for voltage leads. 2 A SP MCB shall be mounted on DIN rail. Doors shall beprovided with 4 sq.mm flexible copper earth leads. Knock - outs of proper dimeter shall be provided on glanding plates. The height of the operating handle of any switch gear shall not be more than 1.8 meters or less than 0.6 mtrs from bottom level of the switch board, type of construction form 4B for Main Switch Boards and other sub panels shall be form 3A. MSB Panel
Supplying, Conveyance, Installation, Testing and Commissioning of Self supported, free standing powder coated cubicle type Main switchboards, fabricated out of CRCA components, chemically treated and powder coated with approved shade. The panel construction with cable entry facility at bottom, cable alley, switchgear compartment, meter chamber, C.Tchamber, busbarchamber etc. shall be fully segregated and compartmentalized. Shrouding of live parts shall be with 3 mm FRP and two fastener screws and chamber partition at dropper connection with 6 mm FRP Control wiring shall be with 2.5 sq.mm copper cables of 1100 volts grad for C.T leads and 1.5 sq.mm for voltage leads. 2 A SP MCB shall be mounted on DIN rail. Doors shall beprovided with 4 sq.mm flexible copper earth leads. Knock - outs of proper dimeter shall be provided on glanding plates. The height of the operating handle of any switch gear shall not be more than 1.8 meters or less than 0.6 mtrs from bottom level of the switch board, type of construction form 4B for Main Switch Boards and other sub panels shall be form 3A. SSB Panel-1
Supplying, Conveyance, Installation, Testing and Commissioning of Self supported, free standing powder coated cubicle type Main switchboards, fabricated out of CRCA components, chemically treated and powder coated with approved shade. The panel construction with cable entry facility at bottom, cable alley, switchgear compartment, meter chamber, C.Tchamber, busbarchamber etc. shall be fully segregated and compartmentalized. Shrouding of live parts shall be with 3 mm FRP and two fastener screws and chamber partition at dropper connection with 6 mm FRP Control wiring shall be with 2.5 sq.mm copper cables of 1100 volts grad for C.T leads and 1.5 sq.mm for voltage leads. 2 A SP MCB shall be mounted on DIN rail. Doors shall beprovided with 4 sq.mm flexible copper earth leads. Knock - outs of proper dimeter shall be provided on glanding plates. The height of the operating handle of any switch gear shall not be more than 1.8 meters or less than 0.6 mtrs from bottom level of the switch board, type of construction form 4B for Main Switch Boards and other sub panels shall be form 3A. SSB Panel-2
Supplying, Conveyance, Installation, Testing and Commissioning of Self supported, free standing powder coated cubicle type Main switchboards, fabricated out of CRCA components, chemically treated and powder coated with approved shade. The panel construction with cable entry facility at bottom, cable alley, switchgear compartment, meter chamber, C.Tchamber, busbarchamber etc. shall be fully segregated and compartmentalized. Shrouding of live parts shall be with 3 mm FRP and two fastener screws and chamber partition at dropper connection with 6 mm FRP Control wiring shall be with 2.5 sq.mm copper cables of 1100 volts grad for C.T leads and 1.5 sq.mm for voltage leads. 2 A SP MCB shall be mounted on DIN rail. Doors shall beprovided with 4 sq.mm flexible copper earth leads. Knock - outs of proper dimeter shall be provided on glanding plates. The height of the operating handle of any switch gear shall not be more than 1.8 meters or less than 0.6 mtrs from bottom level of the switch board, type of construction form 4B for Main Switch Boards and other sub panels shall be form 3A. SSB Panel-3
Supplying, Conveyance, Installation, Testing and Commissioning of Self supported, free standing powder coated cubicle type Main switchboards, fabricated out of CRCA components, chemically treated and powder coated with approved shade. The panel construction with cable entry facility at bottom, cable alley, switchgear compartment, meter chamber, C.Tchamber, busbarchamber etc. shall be fully segregated and compartmentalized. Shrouding of live parts shall be with 3 mm FRP and two fastener screws and chamber partition at dropper connection with 6 mm FRP Control wiring shall be with 2.5 sq.mm copper cables of 1100 volts grad for C.T leads and 1.5 sq.mm for voltage leads. 2 A SP MCB shall be mounted on DIN rail. Doors shall beprovided with 4 sq.mm flexible copper earth leads. Knock - outs of proper dimeter shall be provided on glanding plates. The height of the operating handle of any switch gear shall not be more than 1.8 meters or less than 0.6 mtrs from bottom level of the switch board, type of construction form 4B for Main Switch Boards and other sub panels shall be form 3A. APFC Panel
Supply Installation testing and commissioning of Near by Isolation 2No. 160A TP isolator with enclosure
Supply Installation testing and commissioning of Near by Isolation 1No. 63A TP isolator with enclosure
Supplying, Conveyance, Installation, Testing and Commissioning of Self supported, free standing powder coated cubicle type Main switchboards, fabricated out of CRCA components, chemically treated and powder coated with approved shade. The panel construction with cable entry facility at bottom, cable alley, switchgear compartment, meter chamber, C.Tchamber, busbarchamber etc. shall be fully segregated and compartmentalized. Shrouding of live parts shall be with 3 mm FRP and two fastener screws and chamber partition at dropper connection with 6 mm FRP Control wiring shall be with 2.5 sq.mm copper cables of 1100 volts grad for C.T leads and 1.5 sq.mm for voltage leads. 2 A SP MCB shall be mounted on DIN rail. Doors shall beprovided with 4 sq.mm flexible copper earth leads. Knock - outs of proper dimeter shall be provided on glanding plates. The height of the operating handle of any switch gear shall not be more than 1.8 meters or less than 0.6 mtrs from bottom level of the switch board, type of construction form 4B for Main Switch Boards and other sub panels shall be form 3A. Control desk
Supply, laying, testing & commissioning of 1100V grade, XLPE insulated, PVC sheathed, Aluminium conductor, steel armoured cables for the following sizes. The cable shall be laid as per IS 1255 with fixing accessories mentioned in tender technical specifications. Cables shall be laid through exsiting perforated cable tray /trench / clamped on the walls/slabs with proper Identification tags in every 3meter made out of engraved Aluminium strip, marked with cable size and upstream/downstream panel names and location. 3.5Cx400Sqmm A2XFY Cable
Supply, laying, testing & commissioning of 1100V grade, XLPE insulated, PVC sheathed, Aluminium conductor, steel armoured cables for the following sizes. The cable shall be laid as per IS 1255 with fixing accessories mentioned in tender technical specifications. Cables shall be laid through exsiting perforated cable tray /trench / clamped on the walls/slabs with proper Identification tags in every 3meter made out of engraved Aluminium strip, marked with cable size and upstream/downstream panel names and location. 3.5Cx240 Sqmm A2XFY Cable
Supply, laying, testing & commissioning of 1100V grade, XLPE insulated, PVC sheathed, Aluminium conductor, steel armoured cables for the following sizes. The cable shall be laid as per IS 1255 with fixing accessories mentioned in tender technical specifications. Cables shall be laid through exsiting perforated cable tray /trench / clamped on the walls/slabs with proper Identification tags in every 3meter made out of engraved Aluminium strip, marked with cable size and upstream/downstream panel names and location. 3.5Cx185 Sqmm A2XFY Cable
Supply, laying, testing & commissioning of 1100V grade, XLPE insulated, PVC sheathed, Aluminium conductor, steel armoured cables for the following sizes. The cable shall be laid as per IS 1255 with fixing accessories mentioned in tender technical specifications. Cables shall be laid through exsiting perforated cable tray /trench / clamped on the walls/slabs with proper Identification tags in every 3meter made out of engraved Aluminium strip, marked with cable size and upstream/downstream panel names and location. 3.5Cx95sqmm A2XFY Cable
Supply, laying, testing & commissioning of 1100V grade, XLPE insulated, PVC sheathed, Aluminium conductor, steel armoured cables for the following sizes. The cable shall be laid as per IS 1255 with fixing accessories mentioned in tender technical specifications. Cables shall be laid through exsiting perforated cable tray /trench / clamped on the walls/slabs with proper Identification tags in every 3meter made out of engraved Aluminium strip, marked with cable size and upstream/downstream panel names and location. 3.5Cx70sqmm A2XFY Cable
Supply, laying, testing & commissioning of 1100V grade, XLPE insulated, PVC sheathed, Aluminium conductor, steel armoured cables for the following sizes. The cable shall be laid as per IS 1255 with fixing accessories mentioned in tender technical specifications. Cables shall be laid through exsiting perforated cable tray /trench / clamped on the walls/slabs with proper Identification tags in every 3meter made out of engraved Aluminium strip, marked with cable size and upstream/downstream panel names and location. 3.5Cx35sqmm A2XFY Cable
Supply, laying, testing & commissioning of 1100V grade, XLPE insulated, PVC sheathed, Aluminium conductor, steel armoured cables for the following sizes. The cable shall be laid as per IS 1255 with fixing accessories mentioned in tender technical specifications. Cables shall be laid through exsiting perforated cable tray /trench / clamped on the walls/slabs with proper Identification tags in every 3meter made out of engraved Aluminium strip, marked with cable size and upstream/downstream panel names and location. 3.5Cx25sqmm A2XFY Cable
Supply, laying, testing & commissioning of 1100V grade, XLPE insulated, PVC sheathed, Aluminium conductor, steel armoured cables for the following sizes. The cable shall be laid as per IS 1255 with fixing accessories mentioned in tender technical specifications. Cables shall be laid through exsiting perforated cable tray /trench / clamped on the walls/slabs with proper Identification tags in every 3meter made out of engraved Aluminium strip, marked with cable size and upstream/downstream panel names and location. 4Cx16sqmm A2XFY Cable
Supply, laying, testing & commissioning of 1100V grade, XLPE insulated, PVC sheathed, Aluminium conductor, steel armoured cables for the following sizes. The cable shall be laid as per IS 1255 with fixing accessories mentioned in tender technical specifications. Cables shall be laid through exsiting perforated cable tray /trench / clamped on the walls/slabs with proper Identification tags in every 3meter made out of engraved Aluminium strip, marked with cable size and upstream/downstream panel names and location. 4Cx10sqmm A2XFY Cable
Supply, laying, testing & commissioning of 1100V grade, XLPE insulated, PVC sheathed, Aluminium conductor, steel armoured cables for the following sizes. The cable shall be laid as per IS 1255 with fixing accessories mentioned in tender technical specifications. Cables shall be laid through exsiting perforated cable tray /trench / clamped on the walls/slabs with proper Identification tags in every 3meter made out of engraved Aluminium strip, marked with cable size and upstream/downstream panel names and location. 3Cx1.5 Sqmm Copper Cable
Supply, installation, testing & commissioning of following Al cables end terminations using medium brass cable Double compression glands including gland earthing as per IS3043:87 of adequate size and Compressed terminating Lugs. 3.5Cx400Sqmm A2XFY Cable
Supply, installation, testing & commissioning of following Al cables end terminations using medium brass cable Double compression glands including gland earthing as per IS3043:87 of adequate size and Compressed terminating Lugs. 3.5Cx240 Sqmm A2XFY Cable
Supply, installation, testing & commissioning of following Al cables end terminations using medium brass cable Double compression glands including gland earthing as per IS3043:87 of adequate size and Compressed terminating Lugs. 3.5Cx185 Sqmm A2XFY Cable
Supply, installation, testing & commissioning of following Al cables end terminations using medium brass cable Single compression glands including gland earthing as per IS3043:87 of adequate size and Compressed terminating Lugs. 3.5Cx95sqmm A2XFY Cable
Supply, installation, testing & commissioning of following Al cables end terminations using medium brass cable Single compression glands including gland earthing as per IS3043:87 of adequate size and Compressed terminating Lugs. 3.5Cx70sqmm A2XFY Cable
Supply, installation, testing & commissioning of following Al cables end terminations using medium brass cable Single compression glands including gland earthing as per IS3043:87 of adequate size and Compressed terminating Lugs. 3.5Cx35sqmm A2XFY Cable
Supply, installation, testing & commissioning of following Al cables end terminations using medium brass cable Single compression glands including gland earthing as per IS3043:87 of adequate size and Compressed terminating Lugs. 3.5Cx25sqmm A2XFY Cable
Supply, installation, testing & commissioning of following Al cables end terminations using medium brass cable Single compression glands including gland earthing as per IS3043:87 of adequate size and Compressed terminating Lugs. 4Cx16sqmm A2XFY Cable
Supply, installation, testing & commissioning of following Al cables end terminations using medium brass cable Single compression glands including gland earthing as per IS3043:87 of adequate size and Compressed terminating Lugs. 4Cx10sqmm A2XFY Cable
Supply, installation, testing & commissioning of following CU cables end terminations using medium brass cable gland including gland earthing as per IS3043:87 of adequate size and Compressed terminating Lugs. 3Cx1.5 Sqmm Copper Cable
Earthing for Transformer: Providing CI plate earth electrode of size 1200 x 1200 x 10mm and watering pipe of 2.75m long 40mm diameter including providing charcoal, necessary fasteners etc. as per the IS 3043/2018
Supply and laying of 50X 6 GI Strip for earthing 50X 6 GI Strip
Supply and laying of 25X 6 GI Strip for earthing
Supply and laying of 10SWG CU for earthing
Supply ,Fabrication and fixing cable trays, supports etc using angle iron and flats including painting using 2 coats of synthetic enamel paint over zinc chromate metal primer.
Supply and Providing Rubber Hand Safety Gloves For 1100 V
Supply and Providing Rubber Hand Safety Gloves For 11000V
Providing and fixing 433 V danger notice board of 250mm x 200mm made of mild steel, at least 2mm thick and vitreous enamelled white on both sides and with inscription in signal Red Colour on front side s per IS & KSEB norms.
Providing and fixing 11 kV danger notice board of 250mm x 200mm made of mild steel, at least 2mm thick and vitreous enamelled white on both sides and with inscription in signal Red Colour on front side s per IS & KSEB norms.
Supply and fixing position the approved single line diagram framed in A0 size glass frame and installed in Panel Room
Supply and Installation of HT TOD Meter including testing at TMR and up and down transportation
Testing charges of HT CT PT Unit at TMR including Up and Down Transportatio
Taking soil resistivity at site and obtain test certificate from Electrical Inspectorate Taking soil resistivity
Collection of Data, Preparation of Drawings and other necessary documents, submitting to the District Electrical Inspector, Attending Technical Meeting and finally obtain the Scheme Approval. Remittance of Statutory Fee is excluded from the scope of Electrical Vendor and it shall be Remitted by the Consumer as per the Demand of Statutory Authorities
Preparation of Completion Certificate and other necessary documents, submitting to the District Electrical Inspector, arranging Inspection, attending Technical Meeting and finally obtain the Sanction for Energization. Remittance of Statutory Fee is excluded from the scope of contractor and it shall be Remitted by the client as per the Demand of Statutory Authorities
Preparation of application for obtaining KSEB booklet, preparation of completion report, arranging inspection by KSEB official and giving assistance in obtaining service connection from EB. Remittance of Statutory Fee is excluded from the scope of contractor and it shall be Remitted by the client as per the Demand of Statutory Authorities
FIRE FIGHTING AND FIRE ALARM SYSTEM
Supply, erection, testing and commissioning of Electrical driven Terrace pump with all necessary valves and fittings comprising as follows: Electrical motor driven pump capable of delivering 900 LPM at a head of 35 Mtrs 7.5 Hp mono block to electrical motor fitted in a common base plate, coupling and coupling guard complete
Supply, installation, testing and commissioning of motor control panel for the Terrace pump for fire fighting including all necessary control wiring with indication lamps and meters.
Supply,Installation,Testing and Commissioning of Pressure switch bellow type.
Supply, Installation,Testing and Commissioning of 25 mm dia. Pressure gauge with 0 to 200 PSI,
Supply, erection, testing and commissioning of above ground piping of approved make medium quality GI"B" class pipes of 100 mm dia with branded malleable specials conforming to IS 1239 part 1 & 2 such as tees, elbows, unions, flanges, nipples etc. including cutting, welding and painting the exposed pipes with one coat of zinchromate primer and two coats of PO red enamel paint. The pipes shall be supported suitably
Supply, erection, testing and commissioning of above ground piping of approved make medium quality GI"B" class pipes of 80 mm dia with branded malleable specials conforming to IS 1239 part 1 & 2 such as tees, elbows, unions, flanges, nipples etc. including cutting, welding and painting the exposed pipes with one coat of zinchromate primer and two coats of PO red enamel paint. The pipes shall be supported suitably
Supply, installation, testing and commissioning of slim seal type cast iron butterfly valves of 100 mm lever operated type with necessary flanges, nuts, rubber gaskets and bolts complete
Supply, installation, testing and commissioning of slim seal type cast iron butterfly valves of 80 mm lever operated type with necessary flanges, nuts, rubber gaskets and bolts complete
Supply,Installation, Testing and Commissioning of double flanged horizontal type Non-Return Valve of 100 mm dia as per IS 5312 of following sizes having CI body and SS Disk, with nuts bolts, gaskets etc
Supply, erection, testing and commissioning of single headed Hydrant valve stainless steel with ISI mark as per the IS specification fitted to 80 mm dia pipe
Supply, installation, testing and commissioning of First-aid Hose Reel with MS construction spray painted in Post office Red, conforming to IS 884 with up to date amendments, complete with the following as required as per technical specification(a) 30 m. long 20 mm (nominal internal dia water hose Thermoplastic (Textile reinforced) Type-2 as per IS: 12585(b) 20 mm nominal internal ) dia gun metal globe valve nozzle.(c) Drum and brackets for fixing the equipment's on wall.(d) Connections from riser with 40 mm dia stop valve (gun metal) M.S. Pipe
Supply, installation, testing and commissioning of hose boxes wall/pedestal type of size 600 x 250 x 400 mm made out of 18 guge MS sheet steel with front side glass, locking arrangement and painted with approved colour completed as required and as per specifications.
Supply, installation, testing and commissioning of 63 mm dia, 15 mtr. Long RRL hose pipe with 63 mm dia Male and Female SS couplings duly binded with GI wire, rivets etc. conforming to IS 636 (type-A) as required as per technical specification
Supply, installation, testing and commissioning of 63 mm dia Gun metal branch pipe with 20 mm (nominal internal diameter) size SS nozzle conforming to IS 903, suitable for instantaneous connection to interconnect hose pipe coupling as required
Supply, installation, testing and commissioning of 2 way Fire Brigade Inlet connection of 63 mm dia. built - in Gun metal Non- return valves instantaneous coupling type arrangement to be connected to wet riser main
Supply, installation, testing and commissioning of Ball valve of 20 mm
Supply, installation, testing and commissioning of gunmetal air release valve 25 mm with necessary fittings etc. complete.
Supply, installing, testing and commissioning of Micro processor based Main Fire alarm control panel of 4 zones capacity, with visual LED indications for fire / fault alarms, signals and should have stage alarm facility with maintenance free battery back up for 24 hours normal operation and 15 minutes alarm operation. The panel shall be fabricated by M.S. sheet and powder coated both inside & out side, door shall be glass fronted type with locking arrangement, as per specification.
Supply, Installation, testing and commissioning of Manual Call Point break glass type as per standard specification.
Supply, installation, testing and commissioning of Electronic dual tone Hooter (Sounder) as per standard specification.
Supply, laying and making terminations for 2 Core x 1.5 Sq.mm cable, Screened FRLS Twin Twisted PVC Insulated copper cable, red color along with all accessories required for complete installation, making terminations etc as required Make: POLYCAB , FINOLEX or Equivalent
Supply and installation of ABC Stored pressure type Fire Extinguisher 4 Kgs Capacity Mono Ammonium Phosphate based Dry Chemical Powder as per IS 14609 with ISI Mark for Fighting ABC Class of Fire, stored Pressure type of Mild steel body pressurized by Nitrogen Gas. The Extinguisher shall have pressure gauge for indicating inside pressure with opening and closing lever of squeeze grip type with tamper proof seal, complete with wall bracket. The Extinguisher should be manufactured strictly as per IS: 15683:2006 with ISI mark.
Supply and Providing Glow Sign Board of Fire Duct made of 3 mm thick PVC foam board for each floor 12 x 4 inch
Supply and Providing Glow Sign Board of Fire Exit made of 3 mm thick PVC foam board for each floor 12 x 4 inch
Supply and Providing Glow Sign Board of Exit made of 3 mm thick PVC foam board for each floor 12 x 4 inch
Charges for Obtaining Initial Fire NOC for the building including preparation of Drawings, Application and related documents, Uploading the application through online and offline mode, attending the technical meetings, arranging site inspection etc complete Remittance of fees for obtaining initial NOC is under the scope of Client department
Charges for Obtaining Final Fire NOC for the building including preparation of Drawings, Application and related documents, Uploading the application through online and offline mode, attending the technical meetings, arranging site inspection etc complete Remittance Fees for obtaining fire NOC is under the scope of client department
saaj constructions (BID ID -2304823)
stage.html
html • 0.03 MB
tech_eval.pdf
fin_eval.pdf
finance_1297298.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .