Loading…
Loading…
Updated dates
Tender Value
Refer Docs
EMD Value
₹34.6 L
Closing Date
15 Apr 2026, 5:00 pmClosed
Baljit Kaur
XEN Contract, HVPNL, Panchkula
Creation of 66kV and 132kV transmission lines in Sonipat and Ambala area on turnkey basis.
2026_HBC_506177_1
20262320996B 6E1D 4ACB 8F56 59E6CED36C992113HVP
Open Tender
Civil Works
365 days
Ganaur Ambala City
AS PER TERMS AND CONDITIONS OF BIDDING DOCUMENT
5 documents required · 5 mandatory
₹11,800
₹34.6 L
Yes
3 Mar 2026
3 Mar 2026
24 Apr 2026
3 Mar 2026
15 Apr 2026
3 Mar 2026
Select, Excess (+), Less (-)
Tender Inviting Authority: SE/Contracts, HVPNL, Panchkula
Name of Work: Line-1: LILO of one circuit of 66kV Sonta - Jansui D/C line having conductor size 0.4 sq inch ACSR Conductor at 66kV S/stn. Nalvi (Line Length = 14Km Approx.) with 0.4 sq inch ACSR conductor in FY 2026-27. Line-2: Creation of second ckt of existing 132kV Tajpur-Begga S/C line on D/C towers with 0.4sq inch ACSR conductor using existing D/C towers as deposit work for HIHMCL by HVPNL in FY 2027-28. Line-3: Creation of LILO of second circuit of 132kV Tajpur- Begga line at proposed 132kV S/stn IIHM Gannaur in FY 2027-28 as deposit work for HIHMCL by HVPNL using monopoles, XLPE cables or multi-circuit/ D/C towers with 0.4 sq inch ACSR conductors, as per sire requirements. (Tentative Length of D/C line= 1.278 KM).
Contract No: EPC-D No. 146 /PD&C
Name of the Bidder/ Bidding Firm / Company :
Sr. No. Item Description Note:- Bidder is requested to go through all notes in technical specification as well as in BOQ. Item/ Part Code Quantity Units Estimated Rate in Rs. P HSN code Addition / Deduction Addition / Deduction Values Currency Convertion against each Item Quoted Currency in INR / Other Currency (Supply) Unit Price (including Ex-works price, F&I and all other taxes, duties, levies/cess excluding GST)(INR) Unit Freight and Insurance Charges in Rs. P UNIT GST rate (%age) (Supply) Sub-total Price (including Ex-works price, F&I and all other taxes, duties, levies/cess excluding GST)(INR) Any Other Taxes in Rs. P Any Other Duties/Levies in Rs. P IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service Tax (Erection) Unit Price (including Ex-works price, F&I and all other taxes, duties, levies/cess excluding GST)(INR) (Erection) Sub-total Price (including Ex-works price, F&I and all other taxes, duties, levies/cess excluding GST)(INR) (Civil) Unit price (including Ex-works price, F&I and all other taxes, duties, levies/cess excluding GST) (INR) (Civil) Sub-total price (including Ex-works price, F&I and all other taxes, duties, levies/cess excluding GST) (INR) Total Price Supply , Erection and Civil (INR)
1 Fabrication and supply of tower part with stubs, bolts & nuts, step bolts, U-bolts, hangers, D-Shackle etc. of following type of towers: 132kV D/C “DA” KRR Design type Tower item1 1 No. Excess(+) Full Conversion INR
2 i) +6mtr extn. Only item2 1 No. Excess(+) Full Conversion INR
3 132kV D/C “DB” KRR Design type Tower item3 1 No. Excess(+) Full Conversion INR
4 132kV D/C “DC” KRR Design type Tower item4 1 No. Excess(+) Full Conversion INR
5 i) +3mtr extn. Only item5 1 No. Excess(+) Full Conversion INR
6 132kV D/C “DD” KRR Design type Tower item6 6 No. Excess(+) Full Conversion INR
7 i) +3mtr extn. Only item7 3 No. Excess(+) Full Conversion INR
8 Fabrication and supply of tower part with stubs, bolts & nuts, step bolts, U-bolts, hangers, D-Shackle etc. of following type of towers: 66kV D/C “DA” KRR Design type Tower item8 16 No. Excess(+) Full Conversion INR
9 i) +3mtr extn. Only item9 1 No. Excess(+) Full Conversion INR
10 66kV D/C “DB” KRR Design type Tower item10 3 No. Excess(+) Full Conversion INR
11 i) +3mtr extn. Only item11 1 No. Excess(+) Full Conversion INR
12 ii) +6mtr extn. Only item12 2 No. Excess(+) Full Conversion INR
13 66kV D/C “DC” KRR Design type Tower item13 1 No. Excess(+) Full Conversion INR
14 66kV D/C “DD” KRR Design type Tower item14 10 No. Excess(+) Full Conversion INR
15 ii) +6mtr extn. Only item15 2 No. Excess(+) Full Conversion INR
16 220kV D/C DC R.S Infra Design type tower item16 2 No. Excess(+) Full Conversion INR
17 ii) +12mtr extn. Only item17 2 No. Excess(+) Full Conversion INR
18 220kV D/C R.S Infra Design Gantry item18 6 No. Excess(+) Full Conversion INR
19 66kV M/C MA KRR Design type tower item19 2 No. Excess(+) Full Conversion INR
20 66kV M/C MD KRR Design type tower item20 1 No. Excess(+) Full Conversion INR
21 66kV M/C MD KRR Design type tower with extra cross arm (set of 3) item21 4 No. Excess(+) Full Conversion INR
22 Design, Vetting, Fabrication, Supply & commissioning including its foundation of following Monopole at Ground (Raft/Pier/Pile) with all parts like cross arms, bolts & nuts, step bolts, U-bolts, D-shackle, Hanger etc. with RL-1, WZ-5, Normal Span length of 300M for ACSR Zebra (0.4 sq”) Conductor. 132kV D/C Cable Termination Monopole (0-15D)/DE type _BXA@14 M suitable for termination of 132KV D/C 1600 sqmm Single Core Aluminum Conductor Milliken type XLPE Insulated cable (6+2 configuration) with following provisions:- i) 8 No. x-arms monopole for D/C cable termination arrangement. ii) Provision of Extra-x-arms on monopole for use of 2 no. spare cables. iii) Arrangement shall be made for connecting these 2 no. spare cables to any phase conductor through existing 6 no. LAs. item22 1 No Excess(+) Full Conversion INR
23 Supply of Earthing of towers Pipe type item23 55 Set Excess(+) Full Conversion INR
24 Supply of following Tower accessories i) Danger Plate item24 55 No Excess(+) Full Conversion INR
25 ii) Number Plate item25 55 No Excess(+) Full Conversion INR
26 iii) Phase Plate (set of 3) item26 72 Set Excess(+) Full Conversion INR
27 iv) Circuit Plate (set of 2) item27 55 Set Excess(+) Full Conversion INR
28 v) Bird Guard (set of 3) item28 38 Set Excess(+) Full Conversion INR
29 vi) Anti climbing device item29 55 Set Excess(+) Full Conversion INR
30 Line Material Conductor (0.4 Sq” ACSR Zebra) item30 93.35 Km Excess(+) Full Conversion INR
31 *132KV Anti-Fog type Disc Insulator or 132KV Silicon Rubber Polymer Insulator strings i) 70 kN item31 144 No. Excess(+) Full Conversion INR
32 ii) 120 kN item32 210 No. Excess(+) Full Conversion INR
33 *66KV Anti-Fog type Disc Insulator or 66KV Silicon Rubber Polymer Insulator strings i) 70 kN item33 135 No. Excess(+) Full Conversion INR
34 ii) 120 kN item34 270 No. Excess(+) Full Conversion INR
35 Hardware Fittings for 0.4 sq inch ACSR Zebra Conductor i. Single ‘I’ Suspension String item35 228 Set Excess(+) Full Conversion INR
36 ii.Single Suspension Pilot String item36 51 Set Excess(+) Full Conversion INR
37 iii.Single Tension String item37 456 Set Excess(+) Full Conversion INR
38 iv. Double Tension String item38 12 Set Excess(+) Full Conversion INR
39 0.4 sq inch ACSR Zebra Conductor Accessories i. Mid Span Compression Joint for ACSR Zebra Conductor item39 62 No. Excess(+) Full Conversion INR
40 ii) Repair sleeves for ACSR Zebra Conductor item40 20 No. Excess(+) Full Conversion INR
41 iii) Vibration damper for ACSR Zebra Conductor item41 1392 No. Excess(+) Full Conversion INR
42 iv) Connector suitable for connecting of 0.4 sq. inch ACSR conductor of LILO of 66kV D/C Sonta-Jansui at 66kV Nalvi with existing 0.4 sq inch ACSR conductor of existing 66kV D/C Sonta – Jansui line. item42 12 No. Excess(+) Full Conversion INR
43 BoQ of OPGW & Communication Equipments OPGW (48 fiber) (DWSM, G.652D) (equivalent to Earth wire: 7/3.15mm in all respect) which includes Section –Lilo point to 132 KV S/Stn IIHM Gannaur item43 1.278 Km Excess(+) Full Conversion INR
44 OPGW (24 fiber) (DWSM, G.652D) (equivalent to Earth wire: 7/3.15mm in all respect) which Includes LILO of one circuit of 66 KV Sonta – Jansui D/C line at 66 KV S/Stn., Nalvi. item44 8.427 Km Excess(+) Full Conversion INR
45 Hardware set for above 48 Fiber OPGW fiber optic (equivalent to Earth wire: 7/3.15mm in all respect) cabling including all cable fittings & accessories except joint box. item45 2 Set Excess(+) Full Conversion INR
46 Hardware set for above 24 Fiber OPGW fiber optic (equivalent to Earth wire: 7/3.15mm in all respect) cabling including all cable fittings & accessories except joint box. item46 9 Set Excess(+) Full Conversion INR
47 FODP 96 F: Indoor type, rack mounted with FCPC coupling and pig tails (5mtrs. Each) item47 1 No Excess(+) Full Conversion INR
48 FODP 48 F: Indoor type, rack mounted with FCPC coupling and pig tails (5mtrs. Each) at 66 KV Nalvi. item48 1 No. Excess(+) Full Conversion INR
49 Joint Box 3-Way (48/24/24 fiber) OPGW to OPGW item49 1 No. Excess(+) Full Conversion INR
50 Joint Box (24 fiber) OPGW to OPGW item50 4 No. Excess(+) Full Conversion INR
51 Detailed Survey, Supply, Laying, testing & commissioning of armored Underground Fiber Optic cable (24 Fiber) in PLB HDPE ducts of suitable size & strength alongwith accessories (as per requirement) in above mentioned sections, installation of Joint boxes, interfacing with existing OPGW on through rate basis as per technical specification. item51 0.263 Km Excess(+) Full Conversion INR
52 Joint Box (48 fiber) OPGW to UGFO item52 1 No. Excess(+) Full Conversion INR
53 Fiber optic Approach cable, 48 fiber (DWSM) along with PLB HDPE Ducts of suitable size & strength and all accessories item53 0.25 Km. Excess(+) Full Conversion INR
54 Fiber optic Approach cable, 24 fiber (DWSM) along with PLB HDPE Ducts of suitable size & strength and all accessories item54 0.75 Km. Excess(+) Full Conversion INR
55 Joint Box (48 fiber) UGFO to FOAC item55 1 No. Excess(+) Full Conversion INR
56 Joint Box (24 fiber) OPGW to FOAC item56 1 No. Excess(+) Full Conversion INR
57 Wideband Communication equipment and spares: Telecom Equipment as required SDH Equipment (STM - 16 MADM upto 5 MSP protected directions): Base Equipment (Common cards, Cross connect/control cards, optical base cards, power supply cards, power cabling, other hardware and accessories including sub racks, patch cord, DDF etc. item57 1 No. Excess(+) Full Conversion INR
58 Optical Interface Cards/SFP S16.1 SFP (the quantities will be decided at the time of detail engineering) item58 4 Nos. Excess(+) Full Conversion INR
59 Tributary cards E1 Interface card ( Min. 32 interfaces per card) item59 2 Set Excess(+) Full Conversion INR
60 Ethernet Interface 10/100 Base T with Layer-2 switching (Min. 8 interfaces per card) item60 2 Nos. Excess(+) Full Conversion INR
61 Gigabit Ethernet (Layer 2) Interface (min. 2 nos.) item61 1 Set Excess(+) Full Conversion INR
62 Equipment Cabinet with DDF and all installation accessories item62 1 No. Excess(+) Full Conversion INR
63 VOIP telephone instrument with one common switch (min. 8 port) compatible with SLDC at required substation. item63 1 No. Excess(+) Full Conversion INR
64 Integration of the Equipment with existing network item64 1 Lot Excess(+) Full Conversion INR
65 Mandatory Spares Telecom Equipment as required SDH Equipment (STM - 16 MADM upto 5 MSP protected directions) Optical Interface Cards/SFP S16.1 SFP (the quantities will be decided at the time of detail engineering) item65 1 No. Excess(+) Full Conversion INR
66 Tributary cards E1 Interface card ( Min. 32 interfaces per card) item66 1 Set Excess(+) Full Conversion INR
67 Ethernet Interface 10/100 Base T with Layer-2 switching (Min. 8 interfaces per card) item67 1 No. Excess(+) Full Conversion INR
68 Gigabit Ethernet (Layer 2) Interface (min. 2 nos.) item68 1 Set Excess(+) Full Conversion INR
69 Pre Connectorized Optical Fiber Patch Cords (10 Mtrs.) -Pack of six Patch cords item69 1 Set Excess(+) Full Conversion INR
70 Supply of 132KV 1600 mm2 Single Core Aluminium Conductor Milliken type XLPE Insulated cable as per technical specification item70 2400 Mtrs. Excess(+) Full Conversion INR
71 Detailed survey including GPR (Ground Penetration Radar survey), Supply, Laying, Testing & Commissioning of 132kV XLPE cable, 1600 sqmm Aluminum Milliken Conductor in Flat formation with one spare cable for each circuit (3+1) alongwith loops and riser in flat formation including Civil works complete in all respect, on through rate basis as per technical specification in Open Cut/Directly Buried Method. Note: - All the work for laying of cables till its commissioning shall be carried out under the supervision of the cable manufacturer and a certificate in this regard shall be issued by the concerned TS wing of HVPNL. item71 Mtrs. Excess(+) Full Conversion INR
72 Detailed survey including GPR (Ground Penetration Radar survey), Supply, Laying, Testing & Commissioning of 132kV XLPE cable, 1600 sq. mm Aluminum Milliken Conductor in Flat formation with one spare cable for each circuit (3+1) including loops and riser in flat formation including Civil works complete in all respect at road crossing on through rate basis as per technical specification in Trenchless HDD Method, if required. item72 560 Mtrs. Excess(+) Full Conversion INR
73 Supply and Erection/Laying of 200MM HDPE Pipe for above item73 2104 Mtrs. Excess(+) Full Conversion INR
74 Indicative quantity of Supply, Erection, Testing & Commissioning of 1x300mm sq. copper conductor PVC insulated, unarmoured, 6.6 kV sheath bonding cable (to be decided as per requirement) item74 200 Mtrs. Excess(+) Full Conversion INR
75 Supply, Erection, Testing & Commissioning of Outdoor End Termination kit for terminatio of cable on Cable Termination Monopole with all accessories as per technical specification suitable for above cable as per bidder standard design item75 8 No. Excess(+) Full Conversion INR
76 Supply, Erection, Testing & Commissioning of Outdoor End Termination kit for termination of cable on cable support structure at S/stn end with all accessories as per technical specification suitable for above cable as per bidder’s standard design item76 8 No. Excess(+) Full Conversion INR
77 Supply, Erection, Testing & Commissioning of 120 kV Polymeric Lightning Arrestor on cable termination tower, complete in all respects as per Latest relevant standard and technical specification of HVPNL. item77 6 No. Excess(+) Full Conversion INR
78 Earthing of 120 kV Polymeric Lightning Arrestor to be installed on cable termination Monopole including its all allied material. item78 1 Lot Excess(+) Full Conversion INR
79 Indicative quantity for Supply, Erection, Testing & Commissioning of Single-phase Link Box with SVL for each cable (to be decided as per requirement) (Approx) item79 8 No. Excess(+) Full Conversion INR
80 Indicative quantity for Supply, Erection, Testing & Commissioning of Single-phase Link Box without SVL for each cable (to be decided as per requirement) (Approx) item80 8 No. Excess(+) Full Conversion INR
81 Supply and Erection of Warning Tape item81 263 mtrs Excess(+) Full Conversion INR
82 Supply and Installation of Cable Cleats and other miscellaneous material like all terminal connectors, Trefoil clamps, Nuts & bolts etc for mounting of cables at cable termination Lattice towers and at cable termination structures as per technical specification item82 1 Lot Excess(+) Full Conversion INR
83 Complete Earthing material Set for earthing at all cable terminations, cable joints, LAs, equipment structures and S/Stn. end (as per technical specification) item83 1 Lot Excess(+) Full Conversion INR
84 DISMANTLEMENT WORK TO BE INCLUDED IN ERECTION PART OF BOQ i) Dismantlement of following design of towers including its transportation: - The dismantlement of tower shall also include dismantlement of Stub concrete upto a depth of 1M (one meter) from Natural Ground level, back filling, compaction and clearing the site of debris as per satisfaction of field office along with their transportation & proper stacking at any dedicated store of HVPNL. i. 66kV S/C A Type Tower (HESB Design) item84 3 No Excess(+) Full Conversion INR
85 ii) 66kV S/C B Type Tower (HESB Design) item85 2 No Excess(+) Full Conversion INR
86 iii) 66kV S/C C Type Tower (HESB Design) item86 1 No Excess(+) Full Conversion INR
87 iv) 4 Pole item87 9 No Excess(+) Full Conversion INR
88 iv) H Pole item88 51 No Excess(+) Full Conversion INR
89 ii) Dismantlement of existing ACSR Wolf conductor complete with H/W fittings and accessories along with their transportation & proper stacking at designated Dedicated Store of HVPNL. (approx.) item89 8.4 running ckt. Km Excess(+) Full Conversion INR
90 iii) Dismantlement of existing Earth wire complete with H/W fittings and their transportation & proper stacking at designated Dedicated Store of HVPNL. (approx.) item90 8.4 running ckt. Km Excess(+) Full Conversion INR
91 Any other item/items left out but required to complete the work item91 1 lump sum Excess(+) Full Conversion INR
92 Civil BOQ Detailed Survey item92 11 Km Excess(+) Full Conversion INR
93 Furnishing bore log data item93 11 No Excess(+) Full Conversion INR
94 Construction of tower foundations as per HVPNL Drgs & Specifications for 0 to 6Mtr. extn. including excavation, concreting, supply and placement of steel reinforcement and backfilling complete in all respect. i) 132kV D/C 'DA' type Tower (KRR Design) classified as - Wet item94 1 No Excess(+) Full Conversion INR
95 ii) 132kV D/C 'DB' type Tower (KRR Design) classified as - Wet item95 1 No Excess(+) Full Conversion INR
96 iii) 132kV D/C 'DC' type Tower (KRR Design) classified as - Wet item96 1 No Excess(+) Full Conversion INR
97 iv) 132kV D/C 'DD' type Tower (KRR Design) classified as - Wet item97 6 No Excess(+) Full Conversion INR
98 i) 220 kV D/C Gantry (RS Infra Design) item98 6 No Excess(+) Full Conversion INR
99 Construction of fencing arrangement around the Cable termination towers/ Monopole /gantries complete in all respect including excavation,back filling of earth, supply of all fencing & construction material i.e. cement, steel, aggregates and water or any other type of material required to complete the job etc. item99 20 Mtr Excess(+) Full Conversion INR
100 Construction and installation of RCC route markers as per Drg. No. HCD/TS-1417 complete in all respect including supply of all construction material i.e. cement, steel, aggregates and water or any other type of material required to complete the job etc item100 9 No. Excess(+) Full Conversion INR
101 Construction of tower foundations as per HVPNL Drgs & Specifications for 0 to 6Mtr. extn. including excavation, concreting, supply and placement of steel reinforcement and backfilling complete in all respect. i) 66kV D/C 'DA' type Tower (KRR Design) classified as - Wet item101 16 No. Excess(+) Full Conversion INR
102 ii) 66kV D/C 'DB' type Tower (KRR Design) classified as - Wet item102 3 No. Excess(+) Full Conversion INR
103 iii) 66kV D/C 'DC' type Tower (KRR Design) classified as - Wet item103 1 No. Excess(+) Full Conversion INR
104 iv) 66kV D/C 'DD' type Tower (KRR Design) classified as - Wet item104 10 No. Excess(+) Full Conversion INR
105 v) 66kV M/C 'MA' type Tower (KRR Design) classified as - Wet item105 2 No. Excess(+) Full Conversion INR
106 vi) 66kV M/C 'MD' type Tower (KRR Design) classified as - Wet item106 5 No. Excess(+) Full Conversion INR
107 Construction of tower foundations as per HVPNL Drgs & Specifications for above 6Mtr. extn. including excavation, concreting, supply and placement of steel reinforcement and backfilling complete in all respect. i) 220kV D/C 'DC+12' type Tower (RS Infra Design)classified as - Wet item107 2 No. Excess(+) Full Conversion INR
108 Dewatering of subsoil water for lowering of water table to enable excavation of earth, concreting for foundations/stub and backfilling, by boring of tube wells or deploying well point system so that continuous lowering of water table is made till completion of work, without disturbing the soil characteristics. The rate shall include all type of expenditure for required dewatering arrangements and disposal of extracted mud/water to suitable location as decided by engineer-in-charge irrespective of type of tower including extensions if any. item108 2 No. Excess(+) Full Conversion INR
Total in Figures
Quoted Rate in Figures Select %
Please Enable Macros to View BoQ information
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 2.71 MB
BOQ_584909.xls
BOQ • 0.39 MB
AD0154004.pdf
Additional Documents • 16.29 MB
OT0154004.pdf
Other Document • 0.33 MB
Download all tender documents and submit your bid