Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Infra Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.4 LAccepted-AOC AT PO URIMARI DISTT HAZARIBAGH JHARKHAND PIN 825311 | URIMARI | HAZARIBAGH | JHARKHAND | 825311 | L1 | Accepted-AOC As per AOC | |
| 2 | L3₹4.5 L+₹6,014.60 (1.36%)Rejected-AOC AT BANGLA KUWAN BHURKUNDA P O BHURKUNDA RAMGARH JHARKHAND PIN 829135 | BHURKUNDA | RAMGARH | JHARKHAND | 829135 | L3 | Rejected-AOC As per AOC | |
| 3 | L4₹5.4 L+₹92,420.52 (20.9%)Rejected-AOC AT URIMARI P O SAYAL HAZARIBAGH JHARKHAND | HAZARIBAGH | HAZARIBAGH | JHARKHAND | L4 | Rejected-AOC As per AOC | |
| 4 | L4₹5.4 L+₹92,420.52 (20.9%)Rejected-AOC AT PO MAIN ROAD SAYAL DISTT RAMGARH JHARKHAND | MAIN ROAD SAYAL | RAMGARH | JHARKHAND | L4 | Rejected-AOC As per AOC |
Tender Value
₹8.6 L
EMD Value
₹10,800
Closing Date
22 Jul 2024, 5:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Project Engineer (EnM),Urimari OCP
Office of The Project Engineer (EnM),Urimari OCP, Barka Sayal Area, Pin 825311
Erection and Dismantling of poles and OH lines from Sayal 11KV Substation to Tipla Siding substation under Urimari OCP.
2024_CCL_312230_1
PE(EnM)/Urimari/e Tender/24-25/11
Open Tender
Electrical and Maintenance Works
Item Wise
20 days
Urimari OCP
As per NIT
2 documents required · 2 mandatory
₹10,800
13 Oct 2024
10 Jul 2024
23 Jul 2024
11 Jul 2024
22 Jul 2024
11 Jul 2024
11 Jul 2024 - 18 Jul 2024
Amount
Part A: Erection- Erection of metallic pole of above 10.00 Mtr and upto 12.00 Mtr length in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) foundation including excavation and refilling etc. as required.
Supplying and erection of stay set complete (galvanised) for 11KV overhead lines with 19/ 20 mm dia X 1.8 metres long stay rod, anchor plate of size 45 cm X 45 cm X 7.5 mm, thimble, stay clamps, turn buckle ( 20 mm X 60 cm ), 7/ 4.00 mm dia G.I. stay wire and strain insulator etc in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size ) foundation including excavation and refilling etc. as required.
Supplying of two lengths of channel iron 75mm x 40mm x 6 mm(7.14Kg/mtr)double pole cross arm for three wire 11KV overhead line conductors complete with through bolts and nuts for clamping to the poles, 50mm x 6mm M.S flats welded on one side to the channel iron and with bolts and nuts on other side for tying the cross arms together, including drilling holes for insulator pins/fittings, bolts ,nuts and washers etc(as per drawing) and painting with primer and finish paint as required.
Supplying of channel iron 75 mm X 40 mm X 6 mm (7.14 kg per metre)cross arm for two 11KV over head line conductors with 50mm x 50mm x 6mm(Angle iron bracket welded to the channel iron) and complete with 50mm x 6mm MS flat iron clamps, bolts, nuts and washer etc including drilling of holes for insulator pins etc (as per drawing) and painting with primer and finished paint as required .
Supplying of channel iron 75 mm X 40 mm X 6 mm (7.14 kg per metre)cross arm for two 11KV over head line conductors complete with clamps, bolts, nuts and washer etc including drilling of holes for insulator pins etc (as per drawing) and painting with primer and finished paint as required .
Erection of pole top/straight two wire/v shape two wire, angle iron/ channel iron, cross arm on steel tubular/ rail/PCC pole for 11/22/33KV as required.
Erection of double pole 3 wire cross arm for 11/22/33 KV overhead lines as required
Erection of all aluminium conductor of 7/1.96 mm to 7/3.10 mm diameter including binding etc. as required
Erection of disc/ pin insulator for 11KV over head lines as required
Supplying and erection of a set of cross bracing FRL same work for 11KV overhead line double pole structure having four members fabricated out of 50 mm X 50 mm X 6 mm angle iron to form a rectangle of minimum size 1400 mm width x 2500 mm height, complete with 50mm x 6mm M.S. flat iron clamps, bolts, nuts and washer etc including drilling of holes for insulator pins etc (as per drawing) and painting with primer and finished paint as required .
Installation of Maintenance free chemical Earthpits dia 50 mm, 3 mtr long with BFC bag 50KG(25x 2) with all accessories
Supply and erection of three piece nonlinear resistor type lightning aressotor suitable for 3 wire, 11KV overhead ines with rated voltage 9KV(rms) with a nominal discharge current rating of 5KA and complete with galvanised clamping arrangement.
Providing and fixing of 6 SWG dia GI wire on surface or recess for connection etc.as required.
Erection of Gang Switch
Erection of Aluminum cable 120 sq.mm
Loading/unloading of poles
Part B: Dismantling- Dismantling of pole/ street light standard/ strut embedded in cement concrete foundation etc. as required.
Dismantling of over head lines comprising of copper/ aluminium overhead conductor, G.I. wire, cross arms, insulators etc. as required.
Dismantling of GOAB Switch
Dismantling of 120 sq. mm Aluminium cable
Loading/unloading/ Transporting of poles.(Truck will be provided by Department)
Loading,Transporting and unloading of Dismantled material from site to store(Truck will be provided by Department)
Total impact of GST for the purpose of CTC
M/S ABHISHEK ENTERPRISES
ANIKET BHARDWAJ
AKHILESH KUMAR SINGH
techsummary_323571.pdf
PDF • 0.67 MB
finsummary_323571.pdf
PDF • 0.67 MB
LOA.pdf
PDF • 0.44 MB
BOQ Comparative Chart
xlsx • 0.01 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .