Bilwal Masulbhai Titabhai
ARC for Providing & Installing pumping Machinery & Street Light work in Various District:- Vadodara, Narmada, Dahod, Panchmahal, Mahisagar, Chhotaudepur, Surat, Bharuch, Tapi, Valsad, Dnag, Navsari, (Two Year) [3rd Attempt]
268518
NIT No 23 [2025-26] Sr No 02
Open
Electrical Works
Works
Vadodara
13 documents required · 8 mandatory · 5 optional
₹1,500
Yes
GUJARAT STATE POLICE HOUSING CORPORATION LIMITED
₹50,000
Yes
23 Jan 2026
23 Jan 2026
23 Jan 2026
4 Feb 2026
23 Jan 2026
Estimated Rate in
Item No. Item Description Unit
1 SITC of submersible pump set single phase for 100 mm. or more bore having motor capacity
and discharge as under with necessary panel box
[a] Motor rating 1 HP ( Upto 12 stage) pump having capacity of 50 LPM at 43 to 45 mtr head
RS: Fifteen Thousand Four Hundred
suitable for 32 mm dia. delivery pipe Each
[b] Motor rating 1.5 HP ( 13 to 16 stage) pump having capacity of 50 LPM at 60 mtr head suitable RS: Seventeen Thousand Four
for 32 mm dia. delivery pipe Each
Hundred Thirty Three only
[c] Motor rating 2 HP (17 stage) pump having capacity of 106 LPM at 40 mtr head suitable for 32 RS: Eighteen Thousand Two
mm dia. delivery pipe Each
Hundred Four only
2 SITC of submersible pump motor set Three phase suitable of 100 mm. or more dia. Bore
having three phase motor not more than 3 H.P. of different range with following motor
capacity head and discharge.
[a] Motor up to 3.0 H.P. (16 to 20 stage) 170 to 185 LPM discharge at 57 to 48 mtrs. Respectively RS: Twenty Thousand Six Hundred
head suitable for 50 mm dia. delivery pipe Each
Ninty Five only
[b] Motor up to 3.0 H.P(13 to 15 stage) 130 LPM discharge at 50 mtrs. Respectively head suitable RS: Twenty Thousand Twenty Six
for 50 mm dia. delivery pipe Each
[c] Motor up to 3.0 H.P( Upto 12 stage) 130 LPM discharge at 54 mtrs. Respectively head RS: Ninteen Thousand Seventeen
suitable for 50 mm dia. delivery pipe Each
3 SITC submersible pump set suitable for bore of 100 mm. dia. or more having three phase
motor above 3 H.P. not more than 5 H.P. with following capacity ..
[a] (17 to 25 stage) 120 to 125 LPM discharge at 155 to 120 mtrs. head respectively suitable for 50 RS: Twenty Six Thousand Six
mm dia. delivery pipe Each
Hundred Twenty Eight only
Estimated Rate in
Item No. Item Description Unit
[b] ( Upto 16 stage) 140 to 180 LPM discharge at 96 to 69 mtrs. head respectively suitable for
RS: Twenty Two Thousand One
50mm dia. delivery pipe Each
Hundred Fifty Three only
4 SITC submersible pump set suitable for bore of 150 mm. dia. or more having three phase
motor capacity above 3 H.P. and not more than 5 H.P. with following capacity ..
[a] (6 to 8 stage) 240 to 200 LPM discharge at 70 to 78 mtrs. head respectively suitable for 50mm RS: Thirty Three Thousand
dia. delivery pipe Each
[b] ( Upto 5 stage) 410 to 350 LPM discharge at 40 to 36 mtrs. head respectively suitable for
RS: Thirty Two Thousand One
50mm dia. delivery pipe Each
Hundred Six only
5 SITC submersible pump set suitable for bore of 150 mm. dia. or more having three phase
motor capacity above 5 H.P. and not more than 7.5 H.P. with following capacity ..
[a] (9 to 12 stage) 280 to 240 LPM discharge at 90 to 104 mtrs. head respectively suitable for
RS: Thirty Five Thousand Two
50mm dia. delivery pipe Each
Hundred Thirty Eight only
[b] ( Upto 8 stage) 390 to 350 LPM discharge at 62 to 70 mtrs. head respectively suitable for RS: Thirty Three Thousand Two
50mm dia. delivery pipe Each
Hundred Twenty Five only
6 SITC submersible pump set suitable for bore of 150 mm dia or more having 3 phase motor
capacity not Less than 10 HP with following capacity.
[a] ( Upto 10 stage) 575 to 480 LPM discharge at 60 to 70 mtr head for 65 mm dia delivery pipe RS: Thirty Nine Thousand Two
Hundred Sixty Seven only
[b] (11 to 20 stage) 210 to 160 LPM discharge at 148 to 173 mtr head for 50 mm dia delivery pipe RS: Forty Three Thousand Nine
Hundred Sixty Two only
[c] (21 to 25 stage) 160 to 100 LPM discharge at 185 to 220 mtr head for 50 mm dia delivery pipe RS: Forty Eight Thousand Six
Hundred Sixty Two only
Estimated Rate in
Item No. Item Description Unit
7 SITC submersible pump set for bore of 150 mm. dia. Or more having 3 phase motor capacity
above 10 H.P. and not more than 12.5 HP.With following capacity
[a] ( Upto 12 Stage) 390 to 350 L.P.M. discharge at the head about 95 to 107 mtrs. suitable for
RS: Forty Eight Thousand Six
mm dia. Delivery pipe Each
Hundred Sixty Two only
[b] (13 to 25 Stage) 210 to 140 L.P.M. discharge at the head about 185 to 229 mtrs. suitable for 50 RS: Forty Nine Thousand Three
mm dia. Delivery pipe Each
Hundred Thirty Five only
8 SITC submersible pump set for bore of 150 mm. dia. Or, more having 3 phase motor capacity
above 12.5 H.P. and not more than 15 H.P. and discharge capacity having
[a] (13 to 15 Stage) 480 to 330 L.P.M at the head 105 to 135 mtrs. suitable for 65 mm dia. delivery
pipe RS: Fifty Five Thousand Three
Hundred Seventy Three only
[b] (11 & 12 Stage) 360 to 410 L.P.M. at the head 84 to 108 mtrs suitable for 65 mm dia. delivery
RS: Fifty Three Thousand Six
Hundred Ninty Five only
[c] (9 &10 stage) 600 to 500 L.P.M. at the head 70 to 85 mtrs suitable for 65/50 mm dia. delivery RS: Fifty One Thousand Six Hundred
Eighty Three only
[d] ( Upto 8 stage) 695 to 492 L.P.M. at the head 48 to 73 mtrs suitable for 65/50 mm dia. delivery
RS: Forty Nine Thousand Four
Hundred Forty Five only
9 SITC submersible pump set for bore of 150 mm. dia. Or more having 3 phase motor capacity
about 20 H.P and discharge capacity having
[a] (15 to 20 Stage) 370 to 350 LPM discharge at head in between 168 to 177 mtrs. suitable for
mm dia. delivery pipe Each 65000.00 RS: Sixty Five Thousand only
[b] (9 to 14 Stage) 650 to 550 LPM discharge at head 84 to 112 mtrs suitable for 65 mm dia. RS: Sixty Thousand Four Hundred
delivery pipe Each
Estimated Rate in
Item No. Item Description Unit
[c] (Upto 8 Stage) 1000 to 900 LPM discharge at head 59 to 64 mtrs suitable for 80 mm dia.
RS: Fifty Seven Thousand Six
delivery pipe Each
Hundred Eleven only
10 SITC submersible pump set for bore of 200 mm. dia. or more having 3 phase motor capacity
about 25 H.P. and discharge capacity having
[a] (9 to 12 Stage) 472 to 330 L.P.M. discharge at the head 120 to 192 mtrs. suitable for 65 mm dia. RS: Sixty Nine Thousand Three
delivery pipe Each
Hundred Fifty Six only
[b] (7 & 8 Stage) 1000 to 750 L.P.M. discharge at the head 87 to 115 mtrs. suitable for 80 mm dia. RS: Sixty Eight Thousand Three
delivery pipe Each
Hundred Fifty Two only
[c] (6 Stage) 1000 to 800 L.P.M. discharge at the head 84 to 102 mtrs. suitable for 80 mm dia. RS: Sixty Seven Thousand Three
delivery pipe Each
Hundred Forty Four only
[d] (Upto 5 Stage) 1400 to 1200 L.P.M. discharge at the head 64 to 79 mtrs. suitable for 100 mm RS: Sixty Five Thousand Four
dia. delivery pipe Each
Hundred Forty One only
11 SITC submersible pump set for bore of 200 mm. dia. or more having 3 phase motor capacity
about 30 H.P. and discharge capacity having
[a] (11 & 12 Stage) 650 to 440 L.P.M. discharge at the head 120 to 190 mtrs. suitable for 80 mm
RS: Eighty Three Thousand Six
dia. delivery pipe. Each
Hundred Ninteen only
[b] (9 & 10 Stage) 620 to 510 L.P.M. discharge at the head 130 to 160 mtrs. suitable for 80 mm dia. RS: Eighty Thousand Eight Hundred
delivery pipe Each
Eighty Two only
[c] (6 to 8 Stage) 900 to 650 L.P.M.discharge at the head 104 to 152 mtrs. suitable for 80 mm dia.
RS: Seventy Eight Thousand Eighty
delivery pipe Each
[d] (Upto 5 Stage ) 1400 to 1150 L.P.M. discharge. at the head 70 to 85 mtrs. suitable for 100 mm
RS: Seventy Five Thousand Eight
dia. delivery pipe Each
Hundred Forty Eight only
12 SITC submersible pump set for bore of 200 mm. dia. or more having 3 phase motor capacity
about 34/35 H.P. discharge capacity having
Estimated Rate in
Item No. Item Description Unit
[a] (7 to 12 Stage) 750 to 500 L.P.M. discharge at the head 172 to 204 mtrs. suitable for 80 mm dia. RS: Ninty Four Thousand One
delivery pipe Hundred Ninty One only
[b] (6 Stage) 1600 to 1150 L.P.M. discharge at the head 72 to 102 mtrs. suitable for 100 mm dia. RS: Eighty Seven Thousand Three
delivery pipe Each
Hundred Seventy Three only
[c] (Upto 5 Stage) 1500 to 1300 L.P.M. discharge at the head 75 to 85 mtrs. suitable for 100 mm RS: Eighty Six Thousand Two
dia. delivery pipe Hundred Fifty Five only
13 SITC submersible pump set for bore of 200 mm. dia. Or more having 3 phase motor capacity
about 40-45 H.P. discharge capacity having
[a] (10 &11 Stage) 930 to 780 L.P.M. discharge at. the head 154 to 182 mtrs. suitable for 80 mm RS: One lac Three Thousand One
dia. delivery pipe Hundred Forty only
[b] (7 to 9 Stage) 1270 to 1180 L.P.M. discharge at. the head 113 to 126 mtrs. suitable for 100 mm RS: One lac One Hundred Ninteen
dia. delivery pipe only
[c] (Upto 6 Stage) 1600 to 1300 L.P.M. discharge at the head 81 to 102 mtrs. suitable for 100 mm RS: Ninty Six Thousand Seven
dia. delivery pipe Each
Hundred Sixty Three only
14 SITC submersible pump set for bore of 200 mm. dia. or more having 3 phase motor capacity
about 50-55 H.P. discharge capacity having
[a] (11 to 13 Stage) 100 to 400 L.P.M. discharge at the head 182 to 265 mtrs. suitable for 80 mm
RS: One lac Sixteen Thousand Three
dia. Delivery pipe Each
Hundred Thirty Nine only
[b] (9 & 10 Stage) 1400 to 1200 L.P.M. discharge at the head 117 to 128 mtrs. suitable for 100 mm RS: One lac Eleven Thousand Three
dia. Delivery pipe having Each
Hundred Six only
[c] (Upto 8 Stage) 1400 to 1100 L.P.M. discharge at the head 113 to 138 mtrs. suitable for 100 mm RS: One lac Seven Thousand Nine
dia. Delivery pipe having Each
Hundred Fifty only
15 SITC submersible pump set for bore of 225 mm. dia. or more having 3 phase motor capacity
about 50-55 H.P. discharge capacity having
(Upto 6 Stage) 1800 to 1200 L.P.M. discharge at the head 86 to 114 mtrs. suitable for 100 mm
RS: One lac Three Thousand Four
dia. Delivery pipe having Each
Hundred Seventy Five only
16 SITC submersible pump set for bore of 225 mm. dia. or more having 3 phase motor capacity
about 60 H.P discharge capacity having
Estimated Rate in
Item No. Item Description Unit
[a] (8 to 10 Stage) 1400 to 1150 L.P.M. discharge at the head 141 to 164 mtrs. suitable for 100 mm RS: One lac Thirty Nine Thousand
dia. Delivery pipe Each
Eight Hundred Ninty only
[b] (Upto 7 Stage) 2200 to 1600 L.P.M. discharge at the head 81 to 124 mtrs. suitable for 125 mm
RS: One lac Thirty One Thousand
dia. Delivery pipe Each
Three Hundred Thirty One only
17 Lifting or lowering of submersible motor pump set complete with required No. & size of
casing pipes by means of proper chain pulley block and pipe wrenches. Job includes stacking
of pipes chronologically after due checking of threads, including lifting / lowering.
[a] Upto 60 mtr. RS: One Thousand Six Hundred
Ninty Five only
[b] Above 60 mtr. & up to 120 mtr. RS: Two Thousand Five Hundred
Forty Three only
[c] Above 120 mtr. RS: Two Thousand Nine Hundred
Sixty Seven only
18 [a] Providing & Erecting Bore well cap [a] Up to 200 mm dia. RS: Four Hundred Twenty Four
[b] Above 200 mm dia. RS: Six Hundred Seventy Eight
Estimated Rate in
Item No. Item Description Unit
19 Providing & Erecting 2.0 mtr. long Earthing system by making minimum bore of 225 mm dia.
in soft soil. Suitable for doing pipe-in-pipe technology earthing. Earthing electric rod must be
made from Corrosion free hot dip galvanizing pipes having following specification.
(A) Earthing Electrode: outer Pipe: - 88 mm minimum O.D., 'B ' Class ISI mark of Reputed
Brand, Inner pipe: - 42 mm minimum O.D., Pipe B Class ISI mark reputed Brand. Terminal
Size: 70 mm X 100 mm length, Terminal should be made from inner pipe for that pipe must
be pressed and gave rectangular shape so its work as a terminal. The hot deep galvanising
must be done after above process. Galvanised thickness must be minimum 75 micron
anywhere. SS Nut bolt:- 2 nos. with washer suitable for 14 mm dia. hole must be provided at
terminal. Total minimum Weight (approx.) of earth electrode with inside conductive material
be 26 kg. RS: Seven Thousand Twenty Five
(B) Inner chemical (CCM Compound):- Resistivity:- 0.2 ohm/ meter testing as per IEC 62561- Each
2017, Voltage drop:- < 1 volt at no load & dry form, Sulphur content:- <2%
(C) Back fill Compound:- Earthing compound should be capable to retain moisture for long
time. Back Filling Compound weight is 25 Kg.
(D) Chamber and cover:- Earthing chamber should be size of 400 mm X 400 mm X 400 mm
depth and Cover should be heavy duty cast iron with required size of 300 mm X 300 mm X
Estimated Rate in
Item No. Item Description Unit
Necessary test report must be submitted.
1. Short circuit test by ERDA/ CPRI for 25KA
2. Resistivity test of conducting material from NABL accredited lab.
3. Hot dip galvanised / zinc coating micro test from reputed laboratory.
4. General test report from OEM regarding specification of earthing.
[Make and model approved by EIC Strictly subject to item specification only] [OEM has to
submit all detail & sample for approved before supplying]
[Water must be poured in bore before starting earthing. Earthing value must be measured
with earth tester. Agency has to bring the earth resistance to at least 02 ohms & voltage
between neutral & Earthing upto 02 volt. Agency has to maintain earthing & its value for one
year. Earthing must be done in the presence of A.E. (GSPHCL)]
Estimated Rate in
Item No. Item Description Unit
20 Providing & Erecting 3.0 mtr. long Earthing system by making minimum bore of 225 mm dia.
in soft soil. Suitable for doing pipe-in-pipe technology earthing. Earthing electric rod must be
made from Corrosion free hot dip galvanizing pipes having following specification.
(A) Earthing Electrode: outer Pipe: - 88 mm minimum O.D., 'B ' Class ISI mark of Reputed
Brand, Inner pipe: - 42 mm minimum O.D., Pipe B Class ISI mark reputed Brand. Terminal
Size: 70 mm X 100 mm length, Terminal should be made from inner pipe for that pipe must
be pressed and gave rectangular shape so its work as a terminal. The hot deep galvanising
must be done after above process. Galvanised thickness must be minimum 75 micron
anywhere. SS Nut bolt:- 2 nos. with washer suitable for 14 mm dia. hole must be provided at
terminal. Total minimum Weight (approx.) of earth electrode with inside conductive material
RS: Ten Thousand Four Hundred
Eighty Nine only
(B) Inner chemical (CCM Compound):- Resistivity:- 0.2 ohm/ meter testing as per IEC 62561-
2017, Voltage drop:- < 1 volt at no load & dry form, Sulphur content:- <2%
(C) Back fill Compound:- Earthing compound should be capable to retain moisture for long
time. Back Filling Compound weight is 50 Kg.
(D) Chamber and cover:- Earthing chamber should be size of 400 mm X 400 mm X 400 mm
depth and Cover should be heavy duty cast iron with required size of 300 mm X 300 mm X
Estimated Rate in
Item No. Item Description Unit
Necessary test report must be submitted.
1. Short circuit test by ERDA/ CPRI for 25KA
2. Resistivity test of conducting material from NABL accredited lab.
3. Hot dip galvanised / zinc coating micro test from reputed laboratory.
4. General test report from OEM regarding specification of earthing.
[Make and model approved by EIC Strictly subject to item specification only] [OEM has to
submit all detail & sample for approved before supplying]
[Water must be poured in bore before starting earthing. Earthing value must be measured
with earth tester. Agency has to bring the earth resistance to at least 02 ohms & voltage
between neutral & Earthing upto 02 volt. Agency has to maintain earthing & its value for one
year. Earthing must be done in the presence of A.E. (GSPHCL)]
21 For Earthing Additional charges for boring in hard rock soil (by Breaker)& filling soft soil in
earth pit. (Certificate for soil have to given by DEE/AE along with Photographs) RS: Two Hundred Seventy Six
22 Providing & fixing double compressed heavy duty flange type brass cable gland with rubber
ring for P V C insulated armoured cable complete with outgoing tails, insulating tape etc. For
following size cables.
[a] 2 to 4 core x 4.0 mm2 Each 43.00 RS: Forty Three only
[b] 2 to 4 core x 6.0 mm2 Each 48.00 RS: Forty Eight only
[c] 2 to 4 core x 10.0 mm2 Each 48.00 RS: Forty Eight only
[d] 2 to 4 core x 16.0 mm2 Each 57.00 RS: Fifty Seven only
[e] 2 to 4 core x 25.0 mm2 Each 61.00 RS: Sixty One only
[f] 31/2 core x 35 to 50.0 mm2 Each 75.00 RS: Seventy Five only
[g] 31/2 core x 70.0 mm2
Each 102.00 RS: One Hundred Two only
[h] 31/2 core x 95.0 mm2
Each 130.00 RS: One Hundred Thirty only
[i] 31/2 core x 120 mm2 RS: One Hundred Thirty Nine
Estimated Rate in
Item No. Item Description Unit
core x 150 mm RS: One Hundred Eighty Nine
[k] 31/2 core x 185 mm2 RS: Two Hundred Thirty Six
[l] 31/2 core x 240 mm2 (120 mm2 x 1/2 core) RS: Two Hundred Forty Five
[m] 31/2 core x 300 mm2 (150 mm2 x 1/2 core)
RS: Two Hundred Seventy Eight
23 Supplying & erecting 12 mm thick Hylum sheet on existing 25 x 25 x 3 mm red oxide painted
angle iron frame suitable for fixing ICDP / ICTP / DPMCB / FPMCB SWITCH and energy
meter (contractor shall make approved drawing of Hylum sheet to arrange required No. of RS: Two Thousand Two Hundred Eighty
Energy meter & ICDP / ICTP / DPMCB / FPMCB switch-busbar etc. as per Actual space Nine only
available in electrical room at site)
24 Supplying & erecting Approved make MEM type Triple Pole Iron clad or metal clad switch
and Fuse 415 / 500 V. with neutral link confirming to ISS erected on wooden block / A.I.
Frame with necessary Numbering with oil paint by Painter.
[a] For 16 Amp.
Each 620.00 RS: Six Hundred Twenty only
[b] For 32 Amp. RS: Eight Hundred Fifty Seven
[c] For 63 Amp. RS: Two Thousand Twenty Three
[d] For 100 Amp. RS: Three Thousand Four Hundred
Sixty Four only
25 Supplying & erecting Approved make Iron clad or metal clad four pole change over switch
415 V confirming to ISS erected on angle frame duly painted with redoxide paint by Painter.
[a] For 16 Amp. RS: Nine Hundred Sixty Eight
[b] For 32 Amp. RS: One Thousand Two Hundred
Sixty Three only
Estimated Rate in
Item No. Item Description Unit
[c] For 63 Amp. RS: Four Thousand Thirty Five
[d] For 100/125 Amp. RS: Twelve Thousand One Hundred
Eighty Seven only
[e] For 200/250 Amp. RS: Seventeen Thousand Eight
Hundred Seven only
[f] For 400 Amp. RS: Twenty Five Thousand Nine
Hundred Seventeen only
26 Providing and erecting Two way Centre off Double pole MCB Change Over Switch (IS 13947-
3 / IEC 60947-3) in existing box.
[a] For 25 Amp. Cat.II RS: Five Hundred Thirteen
[b] For 25 Amp. Cat.III
Each 560.00 RS: Five Hundred Sixty only
[c] For 40 Amp. Cat.II RS: Five Hundred Sixty Eight
[d] For 40 Amp. Cat.III
Each 636.00 RS: Six Hundred Thirty Six only
27 Supplying & erecting Sheets Steel powder coated enclosure suitable for incorporating RS: One Hundred Seventy Five
one/two nos. MCB(Enclosure Size 4 Inch X 6 inch) Each
28 Providing and erecting Metallic vitrified danger notice board as per language suggested by
engineer incharge for MEDIUM VOLTAGE installation to be erected as per IS-2551. No. 69.00 RS: Sixty Nine only
29 Providing and erecting required size Copper strip for earthing of H.T. OCB / ACB/
Transformer, LT panel board, Motors etc. using copper clamp.With min 80 micron as per RS: Seven Hundred Eighty Seven
IS.Test Certificate must be submitted by agency. Kg.
Estimated Rate in
Item No. Item Description Unit
30 Supplying & erecting bank of all polypropylene condenser (APP type) with standard capacity
of 2,3,5,7, 10,12.5 & 15 KVAR units of P.F. correction for operation on 3 phase 50 c/s,
/440V (+ / - 10%) with externally discharging resistance, earthing terminal & built on angle
iron of channel iron frame work and provided with terminal cover box. Complete erected on KVAr 690.00 RS: Six Hundred Ninty only
provided iron bracket or on floor duly tested by license.
31 Supplying & erecting approved make motor control cubical panel (Direct - on - line) made
from 16 G. CRCA sheet duly epoxy powder painted inside and outside with hinged doors
and locking, arrangement consisting of suitable size of ON- OFF MCB (AC - 3/23duty) main
fuses, single phasing preventer, indicating lamps for R- Y - B phases, overload relay, Digital
Ammeter, Digital Voltmeter each with two way selector switch incoming, wires duly socket
crimped, main contactor & overload relay, start - stop push buttons, to be erected on angle
iron frame grouted on wall as directed. The MCB , overload relay & contactors will be of L &
T, Siemens or BCH make only.
[a] DOL upto 5.0 H.P RS: Five Thousand Three
Hundred Fourteen only
[b] DOL upto 7.5 H.P
RS: Six Thousand Two Hundred
Estimated Rate in
Item No. Item Description Unit
32 Supplying and erecting approved make motor control cubical panel (Star-Delta) made from
16 G. CRCA sheet duly painted inside with epoxy powder painted inside and outside with
hinged doors and looking arrangement, consisting of suitable size of MCB for ON-OFF, main
fuses, single phasing preventor indicating lamps for R-Y-B phases, overload relay, Digital
ammeter & Digital voltmeter each with two way selector switch, incoming wires duly socket
crimped. Panel to be erected on angle Iron frame grouted on wall as directed. Star-Delta &
main contactor, overload relay, thermal / Electronics Star delta cut-off timer, Start-Stop push
buttons. The MCB overlod relay & contactors of L&T, Siemens or Cutler-Hammer make only
& Voltmeter & Ammeter of MECO make and V.S.S. & A.S.S. of L&T Make. Panel to be
erected on angle iron frame ground on wall.
[a] S/D up to 7.5 H.P. RS: Ten Thousand Five Hundred
Thirty Three only
[b] S/D up to 10 H.P. RS: Eleven Thousand One
Hundred Thirty Nine only
RS: Eleven Thousand Nine
Hundred Seventy Eight only
RS: Thirteen Thousand Three
Hundred Thirty only
RS: Fifteen Thousand Eight
Hundred Forty Seven only
[f] S/D up to 30 H.P. RS: Twenty One Thousand Two
Hundred Fifty Four only
Estimated Rate in
Item No. Item Description Unit
33 Supplying & erecting approved make 3 motor phase motor control panel (ATS) made from
g. CRCA Sheet duly painted with epoxy pover paint inside and outside with hinged doors
and locking arrangment, consisting of suitable Capacity MCCB switch of AC 23 duty with
HRC fuses (Cat.-III). Starting and running contactors, overload relay, Electronic timer with
master times CT operated Digital Ameter with selector switch, Digital voltmeter with
selector switch, phase indicating lamps, single phasing preventor, overload, start-run and
stop-push buttons, air cooled auto tranformer with 60, 70 & 80% tapping. Panel to be erected
on angle iron frame grouted on wall as directed, contactors, realys, timers etc. shall be of L&T,
Siemens, Cutler Hammer Make, Voltmeter & Ammeter of MECO make and V.S.S. & A.S.S. of
[a] Suitable for 25 H.P.
RS: Twenty Nine Thousand Three
Hundred Seventeen only
[b] Suitable for 30 H.P. RS: Thirty Five Thousand One
Hundred Ninty only
[c] Suitable for 35 H.P.
RS: Thirty Eight Thousand Eight
Hundred Seventy Two only
[d] Suitable for 40 H.P. RS: Forty Two Thousand Six
Hundred Ninty Four only
[e] Suitable for 50 H.P. RS: Fifty Two Thousand Nine
Hundred Two only
[f] Suitable for 60 H.P. RS: Fifty Eight Thousand Nine
Hundred Sixty One only
34 Supplying and erecting Direct-On-Line starter with 18 Amp. rating contactor and with
3.5Amp-18 Amp range directely operated in totally insulated elegant enclosure for single
phase operation upto 3 HP as per IS:13947 complete erected on polished wooden block with Each 2080.00 RS: Two Thousand Eighty only
necessary connection.
Estimated Rate in
Item No. Item Description Unit
35 Supplying and erecting Direct-On-Line starter with 15 Amp. rating contactor and with 4-14
Amp. range directely operated thermal overload relay in sheet steel enclosure for 3 phase
RS: Two Thousand Twenty Six
V, 50 Cys, A.C. motor up to 7.5 H.P. complete erected on polished wooden block with Each
necessary connection.
36 Supplying and erecting Direct-On-Line Electronic starter with 2-5/4-10/8-14/10-16 amp.
Rating relay (variable current seeting) directly operated in totally insulated elegant enclosure
and 18 Amp. rating power relay with start-stop button for single phase operation up to 3 HP
as per complete erected on P.W. block with following featuers.
1. Low voltage cut off below 140 V
2. High volatge cutoff above 280 V RS: One Thousand Five Hundred
Eighty Eight only
3. Over load protection
4. Indicating LEDs for motor on LV, HV & Over load tripping
Additional featuer:- Over load protection (variable) High/Low voltage cut-off, Time delay
facility, Fault indication (LED) with star-stop button.
37 Supplying and erecting with leak proof materials, M.S. heavy duty ISI marked coupling
having threads of 8/11 TPI suitable for 'C' class pipe to make load of pump and pipe
assembly, suitable for
[a] 40 mm.(1.5") dia. 8 TPI Each 71.00 RS: Seventy One only
[b] 40 mm.(1.5") dia. 11 TPI Each 50.00 RS: Fifty only
[C] 50 mm.(2") dia. 8 TPI Each 91.00 RS: Ninty One only
[d] 50 mm. (2")dia. 11 TPI Each 60.00 RS: Sixty only
[e] 65 mm. (2.1/2")dia. 8 TPI RS: One Hundred Twenty Five
[f] 65 mm. (2.1/2")dia. 11 TPI Each 80.00 RS: Eighty only
[g] 80 mm. (3") dia. pipe 8 TPI
Each 150.00 RS: One Hundred Fifty only
[h] 80 mm. (3") dia. pipe 11 TPI Each 89.00 RS: Eighty Nine only
[i] 100 mm. (4") dia. pipe 8 TPI RS: One Hundred Seventy Four
Estimated Rate in
Item No. Item Description Unit
[j] 100 mm. (4") dia. pipe 11 TPI RS: One Hundred Twenty Three
[k] 125 mm. (5") dia. pipe 8 TPI RS: Two Hundred Eighty Nine
[l] 125 mm. (5") dia. pipe 11 TPI RS: One Hundred Eighty Seven
38 Supplying & erecting ISI Marked (Embossed) following size of “B” Class G.I. Pipe with
bend,Union,Reduser, Tee,elbow etc. & erecting as directed by Engineer-in-charge with
necessary plumbing as desired.
[a] For 25 mm. dia. RS: One Hundred Twenty Nine
[b] For 32 mm dia RS: One Hundred Seventy Five
[c] For 40 mm. dia.
Mtr. 210.00 RS: Two Hundred Ten only
[d] For 50 mm. dia.
Mtr. 260.00 RS: Two Hundred Sixty only
[e] For 65 mm. dia. RS: Three Hundred Forty Two
[f] For 80 mm. dia. RS: Four Hundred Forty One
[g] For 100 mm. dia. RS: Six Hundred Eighty Four
39 Providing and erecting busbar chamber confirming to ISI 375 fabricated from 16 GMS sheet
dust and vermin proof having hinged door with rubber gasket and necessary busbar
supports with copper busbar having current density not more than 1.6 Amp. / sq.mm. (Rated
current / cross section area) duly wrapped with colour insulation tape for three phase and
neutral each one meter capacity with necessary painting mounted on wall or pedestal frame
of required size with necessary incoming and outgoing connection with proper size of copper
strip / wire with lugs as directed.
Estimated Rate in
Item No. Item Description Unit
[a] Suitable for 100 Amp. Capacity RS: Four Thousand Three Hundred
Seventy Eight only
[b] Suitable for 200 Amp. Capacity RS: Five Thousand Six Hundred
Seventy Five only
[c] Suitable for 300 Amp. Capacity RS: Eight Thousand Four Hundred
Fifty Five only
[d] Suitable for 400 Amp. Capacity RS: Ten Thousand Two Hundred
Thirty Nine only
40 Supplying and fixing Heavy duty clamp made from 4" x 1.5" iron stip suitable for column
pipe 1.5" to 2" length.
[a] 40 mm. (1.5") dia. pipe RS: One Hundred Forty Three
[b] 50 mm. (2") dia. pipe RS: One Hundred Seventy Eight
[c] 65 mm. (2.1/2") dia. pipe
Each 204.00 RS: Two Hundred Four only
[d] 80 mm. (3") dia. pipe
Each 219.00 RS: Two Hundred Ninteen only
[e] 100 mm. (4") dia. pipe
Each 280.00 RS: Two Hundred Eighty only
41 Supplying and erecting MS / CI flanges heavy duty for pipe connections with newly
hardware materials suitable for
[a] 50 mm. (2") dia. pipe RS: One Hundred Twenty Nine
[b] 65 mm. (2.5") dia. pipe Each 150.00 RS: One Hundred Fifty only
[c] 80 mm. (3") dia. pipe RS: One Hundred Sixty Nine
[d] 100 mm. (4") dia. pipe
Each 210.00 RS: Two Hundred Ten only
[e] 125 mm. (50 ) dia. pipe RS: Three Hundred Ninteen
42 Providing and erecting PVC insulated PVC Sheathed flat flexible Submercible copper cable
ISI marked approved make of size.
Estimated Rate in
Item No. Item Description Unit
[a] 3 Core x 1.5 mm
Mtr. 65.00 RS: Sixty Five only
[b] 3 Core x 2.5 mm2 Mtr. 103.00 RS: One Hundred Three only
[c] 3 Core x 4.0 mm2 RS: One Hundred Forty Five
[d] 3 Core x 6.0 mm2 RS: One Hundred Seventy One
[e] 3 Core x 10 mm2 RS: Two Hundred Ninty Three
[f] 3 Core x 16 mm2 RS: Four Hundred Eighty Four
[g] 3 Core x 25 mm2 Mtr. 641.00 RS: Six Hundred Forty One only
[h] 3 Core x 35 mm2 RS: Nine Hundred Eighty Four
43 Providing & Erecting Mains with ISI marked, 1.1 KV grade electrolyte multi stranded,
annealed copper conductor with heat resistant PVC insulated conforms to IS:694, IEC -
erected in existing pipe of following size (Specifically for control panel, relays, power
switchgears, motor starters & control wiring) with required size of copper lugs, nuts and bolts
if required.(Conductor resistance should be as per IS:8130/1984)
[a] One wire 4.00 sq. mm Mtr. 37.00 RS: Thirty Seven only
[b] One wire 6.00 sq. mm Mtr. 56.00 RS: Fifty Six only
[c] One wire 10.00 sq. mm Mtr. 91.00 RS: Ninty One only
[d] One wire 16.00 sq. mm RS: One Hundred Forty One
[e] One wire 25.00 sq. mm RS: Two Hundred Thirty Four
[f] One wire 35.00 sq. mm RS: Two Hundred Ninty Eight
[g] One wire 50.00 sq. mm RS: Four Hundred Sixty Six
Estimated Rate in
Item No. Item Description Unit
[h] One wire 70.00 sq. mm RS: Six Hundred Sixty Three
44 Providing and erecting water proof straight joint in PVC insulated flat flexible copper cable
by using insulated material water proofing material and making the joint complete
[a] Upto 10 mm2 RS: One Hundred Eighty Eight
[b] 16 to 35 mm2 RS: Two Hundred Seventy Six
45 Providing and erecting bracket consisting of ISI mark "B" class G.I. Pipe 4.2 cm outside
diameter complete with suitable G.I. Sleeve tubing of 2 mm. thick and required size and
length suitable for 76.5 / 80 mm. required size of pole top having nuts and bolts for fixing the
brackets and having spread of Upto 0.70 mtr. length with suitable rise as per site condition
and suitable welded stiffner reducer and nipple with check nut complete painted with one
coat of red oxide and two coats of alluminium paint. or Single arm bracket suitable for
terrace as per design given by EIC (Jindal / Asian / Tata / Surya Prakash make Only)
(FabricatoRupees - Ambica / Fab / Bajaj / Impression equipment Only) (Test certificate to be
[a] For Single arm bracket RS: Four Hundred Eighty Seven
[b] For Double arm bracket
Each 616.00 RS: Six Hundred Sixteen only
[C] For Three arm bracket RS: Seven Hundred Thirty Six
[d] For Four arm bracket RS: Eight Hundred Eighty One
Estimated Rate in
Item No. Item Description Unit
46 Providing and erecting bracket consisting of ISI mark "B" class G.I. Pipe 4.2 cm outside
diameter complete with suitable G.I. Sleeve tubing of 2 mm. thick and required size and
length suitable for 76.5 / 80 mm. required size of pole top having nuts and bolts for fixing the
brackets and having spread of 1.00 mtr. length with suitable rise as per site condition and
suitable welded stiffner reducer and nipple with check nut complete painted with one coat of
design given by EIC (Jindal / Asian / Tata / Surya Prakash make Only) (FabricatoRupees -
Ambica / Fab / Bajaj / Impression equipment Only) (Test certificate to be submitted)
[a] For Single arm bracket
Each 608.00 RS: Six Hundred Eight only
[b] For Double arm bracket RS: Eight Hundred Twenty One
[C] For Three arm bracket RS: One Thousand Thirty Five
[d] For Four arm bracket RS: One Thousand Two Hundred
47 Supplying and erecting "B" class Galvanised iron pipe for following size dia. meter having
smooth finished bore of the pipe on both ends erected on the face of the wall with clamps,
nuts and bolts for laying of cable along the pole / wall shaping the pipe as per site
requirement to release cable entry.
[a] For 25 mm dia RS: One Hundred Seventy Nine
[b] For 32 mm dia RS: Two Hundred Thirteen
[c] For 38 / 40 mm. dia.. RS: Two Hundred Forty Seven
[d] For 50 mm. dia. RS: Three Hundred Twenty Three
[e] For 65 mm. dia. RS: Three Hundred Ninty One
Estimated Rate in
Item No. Item Description Unit
[f] For 80 mm. dia.
Mtr. 501.00 RS: Five Hundred One only
48 Supplying and erecting Fabricating terminal box for street light pole made from 16 SWG M.S.
sheet having following size complete with fixing arrangement for terminal board, with
necessary hole for wire entry and exit from the box. The box shall be provided with cover and
hinges on one side and bolting at other end The box shall be fixed by clamps fabricated from
25mm x 6mm flat.The box shall be painted with one coat of red oxide and two coats of paint
having following box size. 330 mm x 260 mm x 140 mm (depth). Providing and fixing Each 702.00 RS: Seven Hundred Two only
Terminal board of size 5.0 x 127 x 152.4 mm. bakelite sheet with 15 Amp. kitkat pattern
porcelain fuse unit heavy duty terminals with suitable brass studs with nuts, washers and
clamps of size 25mm x 3mm suitable for pole painted with one coat of red lead paint.
49 Supplying & erecting approved make SMC press moulded composite FRP. loop-in, loop-out
approx. 2mm thick box complete with Bakelite connector strip 5way(3P+N+E),DIN rail for
mounting mob & hinged doors as per requirement having locking arrangements with
mounting clamp with nuts, bolts & washers suitable for erection on pole with cable clamps& No 890.00 RS: Eight Hundred Ninty only
earth bolt of following size of box. (A) 300mm x 200mm x 100mm [deep]
50 [a] Providing 1:2:4 cement concrete foundation & 70 % PCC from bottom including excavation
for the pole of size 45 x 45 x 100 cm. Deep in below ground level with plinth of 45 cm x 45 cm
(or 45 cm dia x 45 cm) high upper ground level with necessary curing and finishing in
Each 801.00 RS: Eight Hundred One only
approved manner.
( for 4 & 6 mtr pole)
[b] Providing 1:2:4 cement concrete foundation & 70 % PCC from bottom including excavation
for the pole of size 60 x 60 x 120 cm. Deep in below ground level with plinth of 45 cm x
RS: One Thousand Two Hundred
cm(or 45 cm dia x 45 cm) high upper ground level with necessary curing and finishing in Each
approved manner. ( for 7.5 & 8/8.5 mtr pole)
Estimated Rate in
Item No. Item Description Unit
[c] Providing 1:2:4 cement concrete foundation & 70 % PCC from bottom including excavation
for the pole of size 60 x 60 x 150 cm. Deep in below ground level with plinth of 45 cm x
cm(or 45 cm dia x 45 cm) high upper ground level with necessary curing and finishing in RS: One Thousand Six Hundred
approved manner. Thirty Six only
( for 9 & 10 mtr pole)
[d] Providing 1:2:4 cement concrete foundation & 70 % PCC from bottom including excavation
for the pole of size 90 x 90 x 180 cm. Deep in below ground level with plinth of 45 cm x
cm(or 45 cm dia x 45 cm) high upper level ground cement concrete with necessary curing RS: Two Thousand One Hundred
and finishing in approved manner Eighty Eight only
[above 11 mtr & above poles]
51 Brecking existing C.C Foundation upto 0.5 mtr level and make the new C.C Foundation as
Each 950.00 RS: Nine Hundred Fifty only
per above item for the same.
52 Providing and making of Coil Type Earthing Having coil Made From 8 SWG Hot Deep
Galvanized iron Wired wrapped On 50 MM OD Round Pipe Having Minium 50 Turn(
Approximately 200 mm lenght) & Having Contineous lenght Of 3 Mtr Gi wire To Connect
RS: Three Hundred Sixty Nine
Earthing Bolt & Burried In Specially Prrepared Earth Pit Complete With Salt & Each
Charcoal/Coke As Required For Coil Type Earthing (Approximately Weight Of Coil 1 To
53 Drilling the road without breaking the road surface (Asphalt) for laying of cable for feeding
power supply by making upto 150mm dia. size of holes at both ends complete. Mtr. 509.00 RS: Five Hundred Nine only
54 Providing, erecting, fabricating the M.S. structure as per requirement of site as per structure
design Including proper size approved by EIC of M.S. angles, flats, bars, square pipe,
channels, sections (Tata, Jindal, Asian, JSI Make) complete with cutting, welding, grinding
and finishing duly painted with Asian/Nerolac make premium quality oil paint and true care
red oxide metal primer,asian paint make with erection on site as per direction of engineer in
Kg. 77.00 RS: Seventy Seven only
charge with necessary grouting cementing, plastering and finishing complete. All hole
opening of square pipe end must be closed with M.S plate welding. Payment will be done on
KG as per Actual weight.
Estimated Rate in
Item No. Item Description Unit
55 Dismentling existing switch gear control panel and connecting new control panel and
switches existing GEB / AEC power including preparation of application, submission of
application and release of power from GEB / AEC. Job 450.00 RS: Four Hundred Fifty only
56 Providing & Erecting Flexible PVC insulated multistrand multicore 1.1 kv grade ISI marked
copper wires of following size to be erected as directed.
[a] 3 core 1.5 sq.mm. PVC insulated round copper wire ISI mark. Mtr. 46.00 RS: Forty Six only
[b] 3 core 2.5 sq.mm. PVC insulated round copper wire ISI mark. Mtr. 77.00 RS: Seventy Seven only
[c] 3 core 4.0 sq.mm. PVC insulated round copper wire ISI mark. RS: One Hundred Twenty Six
57 Providing & erecting approved make XLPE (IS:7098) (I)-88 ISI mark armoured multistrand
Copper Cable 1100 volt to be laid 90 cms. Under ground or to be laid on wall with 1.0 mm
thick G.I. heavy guage cable clamp or in existing DWC pipe underground or road crossing or
floor of following size of cables.
[a] For 3 core x 2.5 mm2 RS: Two Hundred Thirteen
[b] For 3 core x 4.0 mm2 RS: Two Hundred Eighty Five
[c] For 4 core x 2.5 mm2 RS: Two Hundred Sixty Nine
[d] For 4 core x 4.0 mm2 RS: Three Hundred Sixty One
[e] For 4 core x 6.0 mm2 Mtr. 505.00 RS: Five Hundred Five only
[f] For 4 core x 10.0 mm2 Mtr. 670.00 RS: Six Hundred Seventy only
[g] For 4 core x 16.0 mm2 RS: Nine Hundred Seventy Eight
Estimated Rate in
Item No. Item Description Unit
[h] For 4 core x 25.0 mm2 RS: One Thousand Four Hundred
[i] For 31/2 core x 25 mm2 (10 mm2 x 1/2 core) RS: One Thousand Three Hundred
Thirty Six only
[j] For 31/2 core x 35 mm2 (16 mm2 x 1/2 core) RS: One Thousand Eight Hundred
Forty Nine only
[k] For 31/2 core x 50 mm2 (25 mm2 x 1/2 core) RS: Two Thousand Four Hundred
[l] For 31/2 core x 70 mm2 (35 mm2 x 1/2 core) RS: Three Thousand Five Hundred
[m] For 31/2 core x 95 mm2 (50 mm2 x 1/2 core) RS: Four Thousand Five Hundred
[n] For 31/2 core x 120 mm2 (70 mm2 x 1/2 core) RS: Six Thousand Three Hundred
Sixty Three only
58 Providing & erecting approved make XLPE (IS:7098) (I)-88 ISI mark armoured multistrand
Aluminium Cable 1100 volt to be laid 90 cms. Under ground or to be laid on wall with
mm thick G.I. heavy guage cable clamp or in existing DWC pipe underground or road
crossing or floor of following size of cables.
[a] For 4 core x 4.0 mm2 Mtr. 116.00 RS: One Hundred Sixteen only
[b] For 4 core x 6.0 mm2 RS: One Hundred Twenty Five
[c] For 4 core x 10.0 mm2 RS: One Hundred Thirty Nine
[d] For 4 core x 16.0 mm2 RS: One Hundred Fifty Two
[e] For 4 core x 25 mm2 RS: One Hundred Eighty Nine
Estimated Rate in
Item No. Item Description Unit
[f] For 4 core x 35 mm2
RS: Two Hundred Fifty Three
[g] For 31/2 core x 25 mm2 (16 mm2 x 1/2 core) RS: One Hundred Eighty Two
[h] For 31/2 core x 35 mm2 (16 mm2 x 1/2 core) RS: Two Hundred Eighteen
[i] For 31/2 core x 50 mm2 (25 mm2 x 1/2 core) RS: Two Hundred Eighty Two
[j] For 31/2 core x 70 mm2 (35 mm2 x 1/2 core) RS: Three Hundred Seventy Five
[k] For 31/2 core x 95 mm2 (50 mm2 x 1/2 core) RS: Four Hundred Eighty Six
[l] For 31/2 core x 120 mm2 (70 mm2 x 1/2 core) RS: Five Hundred Thirty Five
[m] For 31/2 core x 150 mm2 (70 mm2 x 1/2 core) RS: Seven Hundred Twenty Four
[n] For 31/2 core x 185 mm2 (95 mm2 x 1/2 core) RS: Eight Hundred Ninty Six
[o] For 31/2 core x 240 mm2 (120 mm2 x 1/2 core) RS: One Thousand One Hundred
Fifty Seven only
[p] For 31/2 core x 300 mm2 (150 mm2 x 1/2 core) RS: One Thousand Three Hundred
Ninty Four only
59 Providing & fixing Solderless crimping type Aluminium lugs conforming to IS suitable for
cable of following size evenly crimped with high pressure tool & connected to switchgear
terminals with brass/cadmium plated nut bolts in an approved manner.
[a] 1.5/2.5/4/6 Sq.mm Each 6.00 RS: Six only
[b] 10 Sq.mm Each 13.00 RS: Thirteen only
[c] 16 Sq.mm. Each 15.00 RS: Fifteen only
[d] 25 Sq.mm. Each 15.00 RS: Fifteen only
Estimated Rate in
Item No. Item Description Unit
[e] 35/50 Sq.mm. Each 20.00 RS: Twenty only
[f] 70 Sq.mm. Each 25.00 RS: Twenty Five only
[g] 95 Sq.mm. Each 40.00 RS: Forty only
[h] 120 Sq.mm. Each 45.00 RS: Forty Five only
[i] 150 Sq.mm. Each 61.00 RS: Sixty One only
[j] 185 Sq.mm. Each 80.00 RS: Eighty only
[k] 240 Sq.mm. Each 85.00 RS: Eighty Five only
[l] 300 Sq.mm. Each 98.00 RS: Ninty Eight only
60 Providing & fixing Solderless crimping type Copper lugs conforming to IS suitable for cable
of following size evenly crimped with high pressure tool & connected to switchgear terminals
with brass/cadmium plated nut bolts in an approved manner.
[a] 1.5/2.5/4/6 Sq.mm. Each 8.00 RS: Eight only
[b] 10 Sq.mm. Each 10.00 RS: Ten only
[c] 16 Sq.mm. Each 12.00 RS: Twelve only
[d] 25 Sq.mm. Each 15.00 RS: Fifteen only
[e] 35/50 Sq.mm. Each 22.00 RS: Twenty Two only
Each 27.00 RS: Twenty Seven only
[g] 95 Sq.mm. Each 47.00 RS: Forty Seven only
[h] 120 Sq.mm. Each 56.00 RS: Fifty Six only
61 Disconnecting the cable connection and Providing straight joint with PVC mould using epoxy
compound Insulating material and making the joint complete using necessary in line
connectors, hardner, earth continuity connection, spacers etc. and reconnecting the same &
ensure the joint resistance within the limits as per IS.
[a] up to 25 Sq mm Cable RS: One Thousand Seventy Three
Estimated Rate in
Item No. Item Description Unit
[b] 35 to 95 Sq. mm cable. RS: One Thousand Five Hundred
Thirty Five only
[c] 120 to 300 Sq. mm cable. RS: Two Thousand Six Hundred
Twenty Eight only
62 Disconnecting the cable connection and Providing T joint with PVC mould using epoxy
compound Insulating material and making the joint complete using necessary in line
connectors, hardner, earth continuity connection, spacers etc. and reconnecting the same &
ensure the joint resistance within the limits as per IS.
[a] up to 25 Sq mm Cable RS: One Thousand Three Hundred
[b] 35 to 95 Sq. mm cable. RS: One Thousand Eight Hundred
Eighty Two only
[c] 120 to 300 Sq. mm cable.
Each 3001.00 RS: Three Thousand One only
63 [a] Providing & laying HDPE Double walled corrugated pipes (DWC) (conforming to IS:
(part 24) 2018)) with minimum load required of 450N capacity with anti rodent and ultra
violet material properties with necessary connecting accessories of same material at required
depth to be laid 90 cms. under ground for laying of cable below ground / road surface for
RS: One Hundred Seventeen
enclosing cable and back filling the same to make ground as per original. (A)For Outer Mtr.
dia.50mm and Inner dia. 38mm (Test Certificate to be Submitted)
[b] For Outer Dia 63 mm (Test Certificate to be Submitted) RS: One Hundred Twenty Eight
[c] For Outer dia. 90 mm and Inner dia. 75 mm. (Test Certificate to be Submitted)
Mtr. 150.00 RS: One Hundred Fifty only
[d] For Outerdia. 120 mm and Innerdia. 103.50 mm (Test Certificate to be Submitted) RS: One Hundred Ninty One
Estimated Rate in
Item No. Item Description Unit
64 Supplying and erecting Galvanized iron pipe post ISI mark 'B' class 88.9 mm. O.D. 4 mtrs.
Long duly painted with two coats of alluminium paint and metallic base plate of 300 x 300 x
4 mm. thick to be erected as a compound light pole with wire entry nipple and earthing bolt.
Approximate weight of pole 32 Kg. within permissible limits as per IS effective length of
sections Bottom: 3.5 mtr. having outside dia. 88.9 mm. Top: 0.5 mtrs. having outside dia.
mm. ( ISI test certificate from pipe manufacture & Class/make/length/O.D/wall RS: Three Thousand One Hundred
thickness/GI/ MS/ Weight test certificate from pole manufacture shall be submitted) (Jindal Ninty Four only
/ Asian / Tata / Surya Prakash make only For G.I Pipe)(Manufacturer's make
Ambica,Fab,Bajaj only,Test Certificate to be Submitted)
65 Supplying and erecting Galvanized iron pipe post ISI mark 'B' class 88.9 mm. O.D. 6 mtrs.
Long duly painted with two coats of alluminium paint and metallic base plate of 300 x 300 x
4 mm. thick to be erected as a compound light pole with wire entry nipple and earthing bolt.
Approximate weight of pole 47 Kg. within permissible limits as per IS effective length of
sections Bottom: 5.5 mtr. having outside dia. 88.9 mm. Top: 0.5 mtrs. having outside dia.
mm. ( ISI test certificate from pipe manufacture & Class/make/length/O.D/wall RS: Four Thousand Three Hundred
thickness/GI/ MS/ Weight test certificate from pole manufacture shall be submitted) (Jindal Ninty Seven only
/ Asian / Tata / Surya Prakash make only For G.I Pipe)(Manufacturer's make
Ambica,Fab,Bajaj only,Test Certificate to be Submitted)
Estimated Rate in
Item No. Item Description Unit
66 Supplying & erecting Steel tubular pole (Swaged) confirming to IS - 2713 (Part-II)
Manufacturing process of steel tubular pole should be as per IS specification. Basic steel tube
should be ISI Marked. Pole should be painted by one coat of Zinc comet Primer and two coat
of Aluminium /approved paint. Erected on / in existing Foundation. The length of poles are
as below. [a] 7.5 mtr. Long Swaged Steel tubular pole (i) Pole as per IS code 410-SP-4 with
X 300 X 4 mm base plate. (Approximate Pole weight 67 Kg.) For burial erection. (Jindal /
Asian / Tata / Surya Prakash make Only) (FabricatoRupees - Ambica / Fab / Bajaj / RS: Seven Thousand One Hundred
Seventy Five only
Impression equipment Only) (ISI test certificate from pipe manufacture & Class / make /
length / O.D. / wall thickness / GI / MS / Weight test certificate from pole manufacture
shall be submitted)
67 Supplying & erecting Steel tubular pole (Swaged) confirming to IS - 2713 (Part-II)
Manufacturing process of steel tubular pole should be as per IS specification. Basic steel tube
should be ISI Marked. Pole should be painted by one coat of Zinc comet Primer and two coat
of Aluminium /approved paint. Erected on / in existing Foundation. The length of poles are
as below. [a] 9.0 mtr. Long Swaged Steel tubular pole (i) Pole as per IS code 410-SP-4 with
X 300 X 4 mm base plate. (Approximate Pole weight 78 Kg.) For burial erection. (Jindal /
Asian / Tata / Surya Prakash make Only) (FabricatoRupees - Ambica / Fab / Bajaj / RS: Eight Thousand Three Hundred
Impression equipment Only) (ISI test certificate from pipe manufacture & Class / make / Eighty only
length / O.D. / wall thickness / GI / MS / Weight test certificate from pole manufacture
shall be submitted)
Estimated Rate in
Item No. Item Description Unit
68 Supplying & erecting Steel tubular pole (swaged) Conforming IS -2713 (Part - II)
disignated 410 SP- 40 made of steel tubes of following dimensions swaged together when hot,
complete painted with one coat of red oxide and two coats of alluminium paint erected with
metallic base plate of 300 x 300 x 6 mm. thick. Over all length 10.00 mtr. with approxi. weight
of pole 128 kg. effective lenght of sections : Bottom 5.2 mtr. having outside dia. 139.7 mm. and
wall thickness 4.5 mm., Middle 2.4 mtr. having outside dia.114.3 mm. and wall thickness
mm., Top 2.4 mtr. having O.D. 88.9 mm. and wall thickness 3.25 mm. (Jindal / Asian / Tata RS: Thirteen Thousand Four
/ Surya Prakash make Only) (FabricatoRupees - Ambica / Fab / Bajaj / Impression Hundred Eighty Four only
equipment Only) (ISI test certificate from pipe manufacture & Class / make / length / O.D. /
wall thickness / GI / MS / Weight test certificate from pole manufacture shall be submitted)
69 Providing & erecting of Steel tubular pole (swaged) Conforming IS -2713 (Part - II)
disignated 410- SP70 made of steel tubes of following dimensions swaged together when hot,
complete painted with one coat of red oxide and two coats of oil paint erected with metallic
base plate of 450mmX450mmX6 mm. thick, Climbing Ladder frame (As per Drawing) , Top
Round ring/ H- Bracket bracket with platform 42'' dia.made from appropriate dia. Pipe&
approximate 1.0 MTR hight from working plat form as per EIC instruction. Over all length
13.0 mtr. with approxi. Weight of pole with out Ladder Should be 312 kg. & Total Weight of
pole with ladder should be Approx. 460 kg. effective lenght of sections : Bottom 5.8 mtr. RS: Twenty Six Thousand Eight
Hundred Twenty Three only
having outside dia. 219.1 mm. and wall thickness 4.85 mm., Middle 3.60 mtr. having outside
dia. 193.7 mm. and wall thickness 4.85 mm,Top 3.60 mtr. having O.D. 165.1 mm. and wall
thickness 4.50 mm.
Estimated Rate in
Item No. Item Description Unit
70 Supplying and erecting approved make Octagonal pole made from HR sheet steel. The pole
should be made as per IS. and shall be coated with hot dip galvanizing as per IS
2629/2633/4759, suitable suspend local wind speed with integral Junction box with Hot Deep
Galvanised door having 2 nos. 180° operated hinges & 2 nos. Ln key locking with silicon
rubber gasket. Consist of terminal plate of min 6mm Hylam sheet, standard profile
35mmX7.5mm Din-Rail & MCB , Brass stud type terminal and arrangement for cable
termination to be erected on RCC foundation as per details given by manufacturer and EIC
considering site requirement.
Foundation Details: 1) Grade of RCC 1:2:4, 2) Grade of steel rainforcement of RCC FE 415, 3)
Clear cover to rainforcement 50mm, 4)Concrete vibrated, 5) use suttering / farma, 6)Hot deep
galvanized average 70Micron, 7) Detail drawing will be given by corporation. (Make:- Bajaj,
Valmont, Ambica, Transril)
[a] 3 Mtr. Long 70 mm Top X 130 mm bottom dia.3 mm thickness with 200mmX200mmX12mm
base plate, 4-M16 Bolts and 450mm long hot deep galvanized J-Bolt, nuts, washers with 800mm
RS: Four Thousand Three Hundred
under ground and 200mm above ground level and 450mm dia. Foundation in 1:2:4 proportion. Each
[b] 4 Mtr. Long 70 mm Top X 130 mm bottom dia, 3 mm thickness with 200mmX200mmX12mm
base plate, 4-M16 Bolts and 450mm long hot deep galvanized J-Bolt, nuts, washers with 800mm
under ground and 200mm above ground level and 450mm dia. Foundation in 1:2:4 proportion. RS: Five Thousand Six Hundred
[c] 5 Mtr. Long 70 mm Top X 130 mm bottom dia, 3 mm thickness with 200mmX200mmX12mm
base plate, 4-M16 Bolts and 600mm long hot deep galvanized J-Bolt, nuts, washers with 800mm
RS: Six Thousand Nine Hundred
under ground and 200mm above ground level and 450mm dia. Foundation in 1:2:4 proportion. Each
Estimated Rate in
Item No. Item Description Unit
[d] 6 Mtr. Long 70 mm Top X 135 mm bottom dia, 3 mm thickness with 200mmX200mmX12mm
base plate, 4-M20 Bolts and 600mm long hot deep galvanized J-Bolt, nuts, washers with 1000mm
under ground and 200mm above ground level and 450mm dia. Foundation in 1:2:4 proportion. RS: Eight Thousand Two Hundred
Twenty Two only
[e] 7 Mtr. Long 70 mm Top X 135 mm bottom dia, 3 mm thickness with 225mmX225mmX16mm
base plate, 4-M20 Bolts and 600mm long hot deep galvanized J-Bolt, nuts, washers with 1300mm
RS: Eleven Thousand Four Hundred
under ground and 200mm above ground level and 450mm dia. Foundation in 1:2:4 proportion. Each
[f] 8 Mtr. Long 70 mm Top X 155 mm bottom dia, 3 mm thickness with 260mmX260mmX16mm
base plate, 4-M20 Bolts and 600mm long hot deep galvanized J-Bolt, nuts, washers with 1300mm
RS: Thirteen Thousand Nine
under ground and 200mm above ground level and 450mm dia. Foundation in 1:2:4 proportion. Each
Hundred Eighty Three only
[g] 9 Mtr. Long 70 mm Top X 155 mm bottom dia, 3 mm thickness with 260mmX260mmX16mm
base plate, 4-M24 Bolts and 750mm long hot deep galvanized J-Bolt, nuts, washers with
1500mm under ground and 200mm above ground level and 450mm dia. Foundation in 1:2:4 RS: Fifteen Thousand Six Hundred
71 Providing and erecting iron clad cable route marker duly marked with ELE CABLE of size
x 12 cms. flushed with ground in cement foundation as directed by Engineer-In-Charge. RS: Two Hundred Thirty Eight
Estimated Rate in
Item No. Item Description Unit
72 Supplying & erecting IP 55 grade following size section pillar fabricated from joint less M.S.
Sheet with angle iron legs made from jointless M.S. Angle with cable clamps to be buried in
ground to have appropriate erection to work uniform until erected with cement concrete
foundation and 45 cm high bricks work finishing with plaster etc. hinged double door
internally supported on both side, with internal and outside looking arrangement with look
and keys in duplicate 35 x 35 x 5 mm M.S. Angle of Two Nos. one is welded and other with
nut and bolt for erecting Bakelite sheet. Painting the Section Pillar inside and out side with
three tank powder coated paint. section pillar roof should be without joint with water
leakage proof & tested as per IP 55 test & followed by IS 2147 of
[a] 150 X 90 X 75 cm section pillar fabricated from 14 Gauge MS Sheet with angle iron legs 95 cm
RS: Sixteen Thousand Five Hundred
long made from 40 X 40 X 6 mm thick MS angle. Each
Twenty Six only
[b] 75 X 60 X 45 cm section pillar fabricated from 16 Gauge MS Sheet with angle iron legs 45 cm RS: Three Thousand Five Hundred
long made from 35 X 35 X 5 mm thick MS angle. Each
[c] 60 X 30 X 45 cm section pillar fabricated from 16 Gauge MS Sheet with angle iron legs 45 cm RS: One Thousand Eight Hundred
long made from 35 X 35 X 5 mm thick MS angle. Each
73 Painting of Streetlight pole having post top lantern complete with primer with two coats of RS: Two Hundred Thirteen
aluminium paint Each
74 [a] Painting of Streetlight pole with bracket complete with primer with two coats of Aluminium RS: Two Hundred Thirteen
paint for following size of pole.Up to 4 Mtr Each
[b] Up to 6 mtr. RS: Two Hundred Sixty Three
[c] Up to 9 mtr. RS: Three Hundred Thirty Two
[d] Up to 13 mtr. RS: Five Hundred Fifty Two
75 Provinding and erecting power contactor AC 3 duty for time switch coplete erected as per
Estimated Rate in
Item No. Item Description Unit
[a] For 2 Pole 12 Amp. Rating 250 V RS: Seven Hundred Eighty Nine
[b] For 2 pole 32 Amp. rating 250 V RS: One Thousand Eight Hundred
Sixty Five only
[c] For 4 pole 40 Amp. rating 440V RS: Two Thousand Seven Hundred
Fifty Five only
76 [a] Providing & erecting weather proof, dust & vermin proof, floor mounted front operated
indoor type double door cubical panel board having IP42 & above protection as per approval
from engineer incharge and made from 2 mm. thick (14 SWG) CRC M.S. sheet for outer body
& doors, 1.6 mm. thick (16 SWG) CRC M.S. sheet for internal partitions with necessary
supporting angles, flats including skirting, bending, drilling, welding, riveting with internal
partitions & cable alley as per requirements & instruction of engineer-In-Charge with erection
of supplied switchgears, busbars with suitable size of interconnecting PVC copper wire /
Copper-Aluminium strips, rubber gromets, rib, control wires, backelite control fuses, RS: Sixteen Thousand Two Hundred
measuring instruments, earth bus & earth bolts, foundation flange-bolts-base plates, sufficient Thirty only
nos. of hinged doors, handle with locking arrangement, rubber gasket complete with
Required Nos. heavy Duty Connector with Cadmium plated nut and bolt for Anti rusting
The panel shall be supplied with Seven Tank chemical process which shall be carried out
before applying painting, painted with powder coating. (The rates excludes the cost of
switchgears, busbars, interconnecting mains & Copper / Aluminium strip, fuse, meters etc.
The dimension shall be measured excluding base beams) The standard companies switch
gear shall be used and only manufacturers at CPRI approved factory as per IEC 61439 and
shall be certified by that company whose switch gears are used after fabrication for beneficial
use. With 350 mm depth.
Estimated Rate in
Item No. Item Description Unit
Panel manufacturer have to give 3 years maintenance and service support if in case of
breakdown or fault. Panel manufacturer have to submit electrical meter calibration report.
Agency should design the panel in such a way that there should not be any excess in panel
area (sq.mtr) & length of bus-bar (mtr), if any excess occurs draw attention to GSPHCL at the
time of approval of G.A. drawing.
Loading and unloading of above item shall be done by hydra and skill work force under
supervision of electrical engineer and guidelines given by manufacturer to avoid damage to
the item. Picture of it to be submitted in running bill / final bill.
Size of door and Ele. room / Pump room shall be checked by agency's engineer before giving
order. If found any problem in size discuss with GSPHCL engineer for rectification before
giving order. [Including Necessary numbering / marking on PANEL done with red colour
radium sticker as per site requirement and instructions given by EIC on site. Font / number
size given by EIC on site as per requirement]
[b] With 550 mm depth
RS: Twenty One Thousand One
Hundred Sixteen only
77 Supplying and erecting tripple pole & neutral 440V / 500 V Panel mounting Copper Busbars
with four equal Nos. of electrolyte bus having current density not more than 1.6 Amp. /
sq.mm (Rated current / cross section area) duly wraped with colour insulating tape for phase
sequence of following current carrying capacity, erected with necessary bus bar supports /
insulators, main cable socket to each bar, erected in existing cubical panel with necessary
[a] For 100 Amp. Capacity RS: One Thousand Nine Hundred
[b] For 200 Amp. Capacity RS: Three Thousand One Hundred
Seventy One only
[c] For 300 Amp. Capacity RS: Four Thousand Eight Hundred
[d] For 400 Amp. Capacity RS: Seven Thousand Two Hundred
Forty Seven only
Estimated Rate in
Item No. Item Description Unit
78 Supplying & erecting approved make by EIC Hi–Tech, Hi-Tensile submersible pump column
pipes UPVC white colour- 3 meter height one end male threaded & other end female
threaded PVC Joint system with coupler & S.S. wire lock (heavy type) (Make: Ashirvad,
Astral make only)
[a] 40 mm (26 kgf/cm²)
RS: Seven Hundred Sixty Five
[b] 50 mm (27 kgf/cm²) RS: One Thousand Sixty Eight
[c] 65 mm (26 kgf/cm²) RS: One Thousand Four Hundred
Sixty Seven only
[d] 80 mm (26 kgf/cm²) RS: Two Thousand Seventy Six
[e] 100 mm (26 kgf/cm²) RS: Three Thousand Three Hundred
Fifty Seven only
79 Supply of following size of TOP & BOTTOM accessories i.e. Adaptor set (CI) long, pump
guard set, starter pipe Rubber ring for submersible pump & UPVC column pipe as directed
by Engineer - in - charge with necessary plumbing as desired.
[a] 25 mm RS: Three Hundred Sixteen
[b] 32 mm RS: Four Hundred Fifty Eight
Per Set 509.00 RS: Five Hundred Nine only
[d] 50 mm RS: One Thousand Four Hundred
Seventy Five only
[e] 65 mm RS: One Thousand Eight Hundred
Eighty Two only
Estimated Rate in
Item No. Item Description Unit
[f] 80 mm RS: Two Thousand Six Hundred
Fifty Five only
[g] 100 mm RS: Three Thousand Eight Hundred
Thirty Four only
80 Providing and erecting Approved make Four Pole moulded case circuit breaker having
breaking capacity/strength ICU of 25 KA. of following K.A. at 415 V. Having normal current
rating following Amp. capacity suitable to work on A.C. supply 50 cys. With all internal
connection & complete Spreader tinned Copper erected in Exsiting 16 G.M.S. housing on
angle fame.ICS=100% of ICU only Cat.–III
[a] 25 Amp. to 100 Amp. (25 K.A. with fixed/variable thermal & Magnetic release) RS: Six Thousand One Hundred
[b] For 125 Amp. (35 K.A. with fixed/variable thermal & Magnetic release) RS: Seven Thousand Nine Hundred
Seventy Six only
[c] For 200 Amp. (35 KA with fixed/variable thermal & Magnetic release) RS: Sixteen Thousand Sixty One
[d] For 250 Amp. (35 KA with fixed/variable thermal & Magnetic release) RS: Twenty Thousand Seven
Hundred Thirty Nine only
[e] For 400 Amp. (50 K.A. with fixed/variable thermal & Magnetic release) RS: Twenty Four Thousand Nine
Hundred Seventy Nine only
81 Supplying, erecting, testing and commissioning of approved make panel mounting type
Digital Voltmeter having 3 digits LED display 0 to 750 AC Volts range having 0.5 Class
accuracy erected on existing panel board with all connection, wiring ete., with manufacturers RS: One Thousand Two Hundred
calibration certificate. Sixty Three only
Estimated Rate in
Item No. Item Description Unit
82 Supplying, erecting, testing and commissioning of approved make panel mounting type
Digital Ammeter having 3 digits LED display, external CT operated, calibrated for 0 to
Amps. suitable to operate on 500 volt AC having 0.5 Class accuracy erected on existing panel RS: One Thousand Five Hundred
board with all connection wiring ete., with manufacturers calibration certificate. Forty Three only
83 Supplying, erecting, testing and commissioning of Ammeter / Voltmeter selector switch for
phase AC supply 500 V on existing panel board with necessary connections. RS: Three Hundred Fourteen
84 Providing & erecting L.T. Current Transformer with bar primary 50/5 to 1000/5 ratio 15 VA
burden havong 0.5 class accuracy erected in existing CRCA box duly secured with insulating
RS: Two Hundred Seventy Two
materials connected to the meter Each
85 Supplying and erecting approved make set of indicator lamps of LED type lamp, lense cover,
Bakelite holder complete erected with necessary connections.
Each 43.00 RS: Forty Three only
86 Providing & erecting 240 V MCB double pole switch for motor & inductive load (C Curve)
having 10 KA breaking capacity & confirms to IS : 8828 in existing box having following
[a] For 6 to 32 Amp. Cat III RS: Two Hundred Ninty Seven
[b] For 40 Amp. Cat III
RS: Three Hundred Twenty Seven
87 Providing & erecting Approved make Earth fault Relay suitable to mount with inter
connection to moulded case circuit breaker having CT ratio & MCCB rating as following
along with shunt trip 220 V AC with all internal connections & complete erected in existing
[a] 15 A-100 A, CT Ratio 1/100 RS: Four Thousand Six Hundred
Estimated Rate in
Item No. Item Description Unit
[b] 125 A-200 A, CT Ratio 1/200 RS: Four Thousand Nine Hundred
Thirty Four only
[c] 250 A-400 A, CT Ratio 1/400 RS: Five Thousand Three Hundred
[d] 600 A-800 A, CT Ratio 1/800 RS: Five Thousand Nine Hundred
Ninty Seven only
88 providing and erecting Approved make RCCBs conforming to IS: 12640 and having
sensitivity of 30 mA and Short Circuit withstand capacity of 10 KA and suitable for operation
on single phase 240 V,50Hz. having characteristic of quick action & tripping with all advance
feature & do not incorporate any electronic component. for following Max. rating erected as
[a] For 25 Amp. Cat.-II. RS: One Thousand Six Hundred
[b] For 25 Amp. Cat.-III. RS: One Thousand Nine Hundred
[c] For 40 Amp. Cat.-II RS: One Thousand Seven Hundred
[d] For 40 Amp. Cat.-III. RS: Two Thousand Two Hundred
(e ) For 63 Amp. Cat.-II RS: Two Thousand One Hundred
Forty Five only
(f) For 63 Amp. Cat.-III. RS: Two Thousand Six Hundred
Twenty Eight only
89 Providing and erecting Approved make RCCBs conforming to IS: 12640 and having
sensitivity of 30 mA and Short Circuit withstand capacity of 10 KA and suitable for operation
on 3 phase and neutral 415V,50Hz. having characteristic of quick action & tripping with all
advance feature & do not incorporate any electronic component for following Max. rating
erected as directed.
[a] For 25 Amp. FP Cat III RS: Two Thousand Five Hundred
Forty Four only
Estimated Rate in
Item No. Item Description Unit
[b] For 40 Amp. FP Cat III RS: Two Thousand Six Hundred
[c] For 63 Amp. FP Cat iII
Each 3010.00 RS: Three Thousand Ten only
[d] For 100 Amp. FP (100 mA Sensitivity) Cat III RS: Four Thousand Two Hundred
Seventy Two only
90 Supplying & erecting approved make Four Pole 415 V change over switch interior for panel
mounting with operating mechanism A.C. 23 duty confirming to IS for
[a] 32-40Amp RS: Two Thousand Five Hundred
Eighty Six only
[b] 63 Amp. RS: Four Thousand Seven Hundred
Thirty Eight only
[c] 100-125 Amp. RS: Seven Thousand Seven Hundred
[d] 200 Amp. RS: Twelve Thousand One Hundred
[e] 250 /320 Amp. RS: Thirteen Thousand Two
Hundred Twenty One only
[f] 400 Amp. RS: Twenty Two Thousand Thirty
91 Testing of Existing Bore well using submersible pump, panel, cable & requirement accessories
and power supply will be provided by agency and obtaining following output data (A)
borewell depth and casing pipe dia. (B) Static water level (C) pumping water level at given
RS: Eight Thousand Three Hundred
flow rate (D) recommended pump Lowering depth (E) Recommended pump specification (F) Per Job
collection of water sample & sanding to laboratory for chemical analysis.
[a] Vehicle Expenses and materials carting for above job Up to 100 KM from concern division
office Per job 2000.00 RS: Two Thousand only
[b] Vehicle Expenses and materials carting for above job Above 100 KM from concern division
office Per job 3000.00 RS: Three Thousand only
Estimated Rate in
Item No. Item Description Unit
92 [a] Providing and erecting point wiring with 1.1 KV grade ISI marked 2 X 1.5 sq. mm copper PVC
insulted FRLS wire with 1.5 sq. mm (green) copper PVC insulated FRLS wire for earth continuity
in FIA approved ISI mark medium class white colour 20/25 mm dia. embossed rigid PVC pipe
with PVC fitting fixed with adhesive solution erected on Brick Wall / slab along with
continuous G.I. fish wire to draw wires and laid in approved manner zari for PVC pipe and
boxes shall be filled with cement mortar and finishing the surface to match the wall / ceiling
complete with approved make 5/6 Amp. ISI make modular type switch and accessories mounted
in 20 G. G.I. company fabricated metallic box covered with appropriate front plate modules
erected flushed with wall / ceiling with necessary modular lamp holder / modular ceiling rose /
HD Connector ( deep junction box75mm if required) ( make & model approved by EIC and
matching colour with switches accessories) as directed for concealed wiring as directed For Open
Wiring Light point. Cat.-II. Necessary sheet / tape / polythene / sand must be erected or filled
in all box to prevent mortar going into the box. Length of point wiring must not increase than 10 RS: Four Hundred Twenty Five
mtr. For that necessary switch boards and their locations must be finalised before execution by only
agency otherwise payment will not be done for extra long point. (For future extention, if
required, agency has to erect one higher size metal box and modular plate as per instruction of
EIC. Cost of blank plate shall be paid as per tender item) [Wire must be having box packing]
[This item include cleaning (inside/outside) of all G.I. switch boards, electric point box, fan box,
MCBDB & box cutting plaster finishing for modular plate without any gap](Conductor resistance
should be as per IS:8130/1984 )
[b] For Fan Point (with 6 A. Modular type switch and two module hum free EME four or more
step type electronic fan regulator both having ISI mark) Cat.-II Point 612.00 RS: Six Hundred Twelve only
[c] For separate Point (with 6 Amp. Switch & 3/5 pin socket both having ISI mark) Cat.-II RS: Four Hundred Fifty Five
[d] For Looped on switch board (with 6 Amp. Switch & 3/5 pin socket both having ISI mark ) RS: Two Hundred Thirty Four
Estimated Rate in
Item No. Item Description Unit
93 [a] Providing and erecting point wiring with 1.1 KV grade ISI marked 2 X 1.5 sq. mm copper PVC
insulted FRLS wire with 1.5 sq. mm (green) copper PVC insulated FRLS wire for earth continuity
in FIA approved ISI mark medium class white colour 20/25 mm dia. embossed rigid PVC pipe
with PVC fitting fixed with adhesive solution erected in Brick Wall / slab along with continuous
G.I. fish wire to draw wires and laid in approved manner zari for PVC pipe and boxes shall be
filled with cement mortar and finishing the surface to match the wall / ceiling complete with
approved make 5/6 Amp. ISI make modular type switch and accessories mounted in 20 G. G.I.
company fabricated metallic box covered with appropriate front plate modules erected flushed
with wall / ceiling with necessary modular lamp holder / modular ceiling rose / HD Connector
( deep junction box75mm if required) ( make & model approved by EIC and matching colour
with switches accessories) as directed for concealed wiring as directed for concealed wiring.
Light point. Cat.-II. Necessary sheet / tape / polythene / sand must be erected or filled in all
box to prevent mortar going into the box. Length of point wiring must not increase than 10 mtr. RS: Four Hundred Sixty One
For that necessary switch boards and their locations must be finalised before execution by agency Point
otherwise payment will not be done for extra long point. (For future extention, if required,
agency has to erect one higher size metal box and modular plate as per instruction of EIC. Cost of
blank plate shall be paid as per tender item) [Wire must be having box packing] [This item
include cleaning (inside/outside) of all G.I. switch boards, electric point box, fan box, MCBDB &
box cutting plaster finishing for modular plate without any gap](Conductor resistance should be
as per IS:8130/1984 )
[b] For Fan Point (with 6 A. Modular type switch and two module hum free EME four or more
RS: Six Hundred Forty Eight
step type electronic fan regulator both having ISI mark) Cat.-II Point
[c] For separate Point (with 6 Amp. Switch & 3/5 pin socket both having ISI mark) Cat.-II RS: Four Hundred Eighty Nine
[d] For Looped on switch board (with 6 Amp. Switch & 3/5 pin socket both having ISI mark) Cat.- RS: Two Hundred Thirty Four
Estimated Rate in
Item No. Item Description Unit
94 Providing following type of Modular Type Accessories mounted with PVC /
metallic/Wooden box, single mounting base frame covered with textured / metallic/white
front plate , modules erected with necessary connections as per site situation directed by
Engineer In charge.Cat-II.
[a] One No. SP 6 Amp. RS: One Hundred Twenty Four
[b] One No 5 pin plug RS: One Hundred Twenty Four
[c] Blank Plate Single
Each 16.00 RS: Sixteen only
[d] 16 Amp. SP one way switch
Each 130.00 RS: One Hundred Thirty only
[e] 16Amp. Universal socket RS: One Hundred Thirty Nine
95 [a] Providing and laying Mains with FRLS PVC Insulated wire ISI marked 1.1 KV grade with
FIA approved ISI mark medium class 20/25/32 mm dia. embossed rigid PVC pipe with
PVC fitting fixed with adhesive solution to be erected on/in brick wall / slab along with
continuous G. I. fish wire to draw mains laid in approved manner with plastering by cement
mortar & finishing the surface to match the wall / ceiling complete with FRLS PVC insulated
wire for earth continuity. (Approved ISI make only) [a] 2 x 1.5 sq.mm. FRLS copper multi
stranded conductor mains with 1.5 sq.mm. FRLS copper multi stranded conductor for Mtr. 62.00 RS: Sixty Two only
earthing as per standard colour code. [Wire must be having box packing](Conductor
resistance should be as per IS:8130/1984)
Estimated Rate in
Item No. Item Description Unit
[b] 2 x 2.5 sq.mm. FRLS copper multi stranded conductor mains with 1.5 sq.mm. FRLS copper
multi stranded conductor for earthing as per standard colour code. (with 20/25 mm dia. PVC
pipe) (for power board and computer board mains) [Wire must be having box packing] Mtr. 82.00 RS: Eighty Two only
(Conductor resistance should be as per IS:8130/1984)
[c] 2 x 4.0 sq.mm. FRLS copper multi stranded conductor mains with 2.5 sq.mm. FRLS copper
multi stranded conductor for earthing as per standard colour code. (with 20/25 mm dia. PVC
pipe) (for power board and computer board mains) [Wire must be having box packing] Mtr. 111.00 RS: One Hundred Eleven only
(Conductor resistance should be as per IS:8130/1984)
[d] 2 x 6.0 sq.mm. FRLS copper multi stranded conductor mains with 2.5 sq.mm. FRLS copper
multi stranded conductor for earthing as per standard colour code. (with 25 mm dia. PVC
pipe) (for MCBDB mains) [Wire must be having box packing] (Conductor resistance should Mtr. 146.00 RS: One Hundred Forty Six only
be as per IS:8130/1984)
96 Providing and erecting Medium Class FIA approved and ISI mark white colour (embossed)
RIGID PVC PIPES of following size complete erected with necessary PVC fittings & Junction
boxes fixed with adhesive solution & clamps on / in wall / ceiling along with continuous fish
wire to draw mains with necessary fittings and junction boxes for following dia.
[a] For 20 mm dia. Mtr. 24.00 RS: Twenty Four only
[b] For 25 mm dia. Mtr. 33.00 RS: Thirty Three only
[c] For 32 mm dia. Mtr. 54.00 RS: Fifty Four only
97 Providing & fixing 20 mm. dia. PVC insulated G.I. Corrugated Flexible pipe with necessary
socket, PVC bushes, saddle, Check-nuts etc. complete of following sizes. Mtr. 31.00 RS: Thirty One only
98 Providing & fixing 25 mm. dia. PVC insulated G.I. Corrugated Flexible pipe with necessary
socket, PVC bushes, saddle, Check-nuts etc. complete of following sizes. Mtr. 37.00 RS: Thirty Seven only
Estimated Rate in
Item No. Item Description Unit
99 Providing ad erecting approved make single phase Single Door metal clad D.B. as per relevant
indian standards ammended upto date.
Supplying and fixing following way single phase MCB distrubution board of company fabricated
MCBDB Door Back Side &body Must Be Made OF 1.2 MM Thick CRCA Sheet sheet with sheet
box with powder coated inside and outside after apply seven tank chemical process of cover
complete with suitable integral single piece construction tinned copper busbar and link with all
necessary interconnection and with necessary size MS frame for mounting MCBDB.
Manufacturer must be provided (1) IP 43 and as per IS:8623-1 & 3, IEC 61439-1 & 3 having D type
PU gasket. (2) Seven tank Powder coating Certificate (3) Tinned Copper/Brass make neutral &
Earthing link with isolation & Protecting Cover for 240 Volts on surface / recess complete with
loose wire box, terminal connectors for all incoming and outgoing circuits, with suitable size
FRLS PVC insulated copper conductor up to terminal blocks and internal connection, tinned
coppper bus bar, 1 no. tinned copper neutral link, tinned copper earth bar, din bar, detachable
gland plate, interconnections, powder painted including earthing etc.
Single phase incoming and horizontal single phase outgoing.
[a] 4 way MCBDB (6 to 25 Amp. - 2 Nos.and 1.00 Nos 40 Amp C curve DP MCB )
Each 907.00 RS: Nine Hundred Seven only
[b] 6 way MCBDB (6 to 25 Amp. - 2 Nos.and 1.00 Nos 40 Amp C curve DP MCB and ELCB 1 Nos
) RS: Three Thousand Three Hundred
Thirty Nine only
[c] 8 way MCBDB (6 to 25 Amp. - 4 Nos.and 1.00 Nos 40 Amp C curve DP MCB and ELCB
Nos) RS: Three Thousand Six Hundred
[d] For 12 Way MCBDB (6 to 25 Amp. - 8 Nos.and 1.00 Nos 40 Amp C curve DP MCB and ELCB
RS: Four Thousand Two Hundred
Eighty Seven only
[e] For 16 Way MCBDB (6 to 25 Amp. - 12 Nos.and 1.00 Nos 40 Amp C curve DP MCB and ELCB
1 Nos ) RS: Four Thousand Nine Hundred
Estimated Rate in
Item No. Item Description Unit
100 Supplying and Erecting LED indoor fitting of approximately 4feet long with LED of wattage
0.2W to 0.5W assemble on single MCPCB with housing use as a heat sink shall be made from
Aluminum extrusion having enough strength (sample must be approved by EIC)with
polycarbonate diffuser with following specification:
(A) Company mark/name on the fitting.
(B) Rated input voltage and frequency: 220V to 240 VAC ; 50Hz.
(C) Rated input wattage: max. 24w RS: Three Hundred Seventy
(D) Rated input current : 0.2 Amp Each
(E) Power Factor : Min.
(F) ATHD :Max. 15%
(G) Rated Luminous flux: Min. 2420 lm
(I) CRI: Min. 80Ra
(J) Driver Efficiency: Min. 80%
(K) LED life span: Min. 50000 Hrs @ L70
(L) Over Voltage protection: Withstand up to 440V/AC for 4 Hrs.
(M) Surge protection : Min. 2KV
(N) IP rating: IP
(O) IK rating : IK
(P) Short circuit , Open circuit & Reverse Polarity Protection must be provided
(Q) Fixing clamp design & strength should be sufficient to hold the fitting erected on wall or
(R) 3 core copper wire of appropriate size with earthing connector
(Note:-The manufacturer/ authorized Channel partner of the manufacturer has to submit
yrs free replacement Guarantee for complete Fixture) [Approval will be given strictly subject
to item specification]
101 Supplying and erecting 8 W LED lamps of 220 to 240 voltage, minimum 15000 burning hours
life, 500 V in built-surge protection,Polycarbonate diffuser, mounting suitable for E14 / E27 /
B22 lamp holders, pf >= 0.5 (A) LED Lamps integral type, with PC diffuser suitable LAMP Each 111.00 RS: One Hundred Eleven only
Estimated Rate in
Item No. Item Description Unit
102 Providing and Erecting Polycarbonate body surface mounting LED Bulk head type 9 watt
Lighting Fitting with electronic driver having THD<15%,CRI>80,PF>0.95 And lumen output
from luminaire 800lm , input voltage range 90-300VAC , 50Hz cool white(3000 to 6500k), RS: Seven Hundred Eighty
inbuilt driver having THO>80 lm/W, -20degC to +60degC working temperature, AL frame Each
with Beam Angle 120deg
103 Providing & erecting Electronic Hum Free 5 pin socket type steps type Fan Regulator. (The
regulator should be used of same company of accessories to be used) (ISI make) RS: Two Hundred Seventeen
104 Providing, erecting, testing and commissioning insu intelligent street light controller specially
designed for energy saving in conventional street light system ( Cat. no. SLC-03-1Ph-15 KVA-
20 Amp. per phase) having technical specification, 1 phase 2 wire, 230 V AC/ph, +/- 25% R Y
B N 2 wire supply system, 50 Hz (+/- 10%) 2 W (Stand BY) to 4 W (at street light operation)
consumption, Advance 8 bit micro controller, switching on longitude and latitude base, RS: Twenty Thousand Two Hundred
accuracy of +/- 1 minute per month, with in built battery, with battery life of more than 8 Fifty Five only
years, with special device which hold the parameter for more than 10 year without any power
and password protected.
16 characters and two line LCD display with backlight, 4 keys user friendly keyboard system,
7500/15000 VA feeder pillar capacity, 60/100 Amps isolator, 3 output with termination,
40/63 Amps 2/3 pole contactor, 3 X 16 Amp., with FR cable provision to by pass by way of
relay operation through auto/manual switch, 2 to 55 centigrade and humidity 90 % non
condensing, Out door type installation on pole with clamps (Provided with clamps and nut
bolt) or wall or floor, Three locking system flush type internal panel lock, external pad lock
and internal U clamp locking systems for against theft of Panel, having 17/25 Kg weight,
Gauge MS weather proof box with industrial exterior powder coated with 7 tank process RAL
Estimated Rate in
Item No. Item Description Unit
105 Providing, erecting, testing and commissioning insu intelligent street light controller specially
designed for energy saving in conventional street light system (Cat. No. SLC-03-15 KW
HMO) having technical specification, 3 phase 4 wire, 230 V AC/ph, +/- 25% R Y B N 4 wire
supply system, 50 Hz (+/- 10%) 3 W (Stand BY) to 5 W (on full load) consumption, Advance
bit micro controller, switching on longitude and latitude base, accuracy of +/- 1 minute per RS: Twenty Nine Thousand Three
month, with in built battery, with battery life of more than 8 years, with special device which Hundred Sixty Six only
hold the parameter for more than 10 years without any power and password protected.
16 characters and two line LCD display with backlight, 4 keys user friendly keyboard system,
25000 VA feeder pillar capacity, 63/100 Amps isolator, 3 output MCB each of 40 Amp., Input
isolator ELCB 63 Amp. 100 mA. 4 pole, with FR cable provision to by pass by way of relay
operation through auto/manual switch, 2 to 55 centigrade and humidity 90 % non
condensing, Out door type installation on pole with clamps (Provided with clamps and nut
bolt) or wall or floor, Three locking system flush type internal panel lock, external pad lock
and internal U clamp locking systems for against theft of Panel, having 30 Kg weight, 16/18
Gauge MS weather proof box with industrial exterior powder coated with 7 tank process RAL
106 Providing & Erecting Univesal Astro interlligent Street light Control Syatem insu with
weather proof box for indoor allplication 5KVA ( as Per atteched Specification) RS: Twelve Thousand Eight
Hundred Ninty Five only
107 Providing & erecting panel mounting type 415 V Four pole MCB switch for motor &
inductive Load (C curve) having 10 KA breaking capacity & confirms to IS:8828 with suitable
size of interconnecting PVC copper wire as per IS having following capacity.
[a] 32 Amp. Each 590.00 RS: Five Hundred Ninty only
Each 662.00 RS: Six Hundred Sixty Two only
[c] 63 Amp. Each 730.00 RS: Seven Hundred Thirty only
Estimated Rate in
Item No. Item Description Unit
108 Providing and erecting Two way Centre off Four pole MCB Change Over Switch (IS 13947-3
/ IEC 60947-3) in existing box.
[a] 25 Amp. RS: Eight Hundred Forty Four
[b] 40 Amp. RS: One Thousand Three Hundred
Thirty One only
109 Supplying & Erecting Approved Make Extended operating rotary handle with pad lock with
three position Trip, Off, On suitable for 25 Amp. to 250 Amp. panel mounting. RS: Eight Hundred Sixty Five
110 Supplying & Erecting Approved Make Extended operating rotary handle with pad lock with
three position Trip, Off, On suitable for 400 Amp. to 630 Amp. panel mounting. RS: One Thousand Two Hundred
Ninty Eight only
111 Supplying & erecting approved make Automatic liquid level controller 6A. with SS sensor
testing as per instruction of Engineer in charge on site complete with wiring connection.
Wiring between Under ground tank sensors to Liquid level controller & over head tank
RS: Two Thousand Three Hundred
sensors to Liquid level controller is excluding. Agency has to install 3CoreX1.5mm2 copper Each
Thirty Two only
flexible wire ISI mark as per tender item.
Estimated Rate in
Item No. Item Description Unit
112 Providing and Fixing SITC of Outdoor aesthetically designed LED Street Light Luminaire
with total consumption of Max. 45 W with single piece die cast aluminium housing, high
power LED shall be mounted on high quality metal core PCB with extremely precison
designed heat sink complete with IP66 protection Class with polycarbonate / thoughened
glass cover the fixture should be suitable for pole/bracket mounting. The fixture to comply
both LM79 and LM 80 guidelines with LED module min. 130 lumen/watt with toughen Glass
L70 at 50,000 hrs, provided with high quality polycarbonate lenses for better light
distribution. The Fixture Should be able to be Pole Mounted and also bracket mounted,
provided with high quality driver for protection against high and low Voltage cut Off,
opertional for high amibient and high humid envirnoments, THD of driver should be less
than 10% and P.F > 0.95. Also the Fixture should meet the following technical criterias
RS: Three Thousand Five Hundred
Oprating range Voltage 160 to 270 V, system efficiency >= 110 lm/w, and total lumens not Each
less then 4950, CCT > 5000K, CRI > 65, beam angle 120 deg, 4kV integral & non integral surge
immunity level at least 10 KV non integral..The Separate Potted driver should have over
current, over voltage protection, short circuit protection so that the fixture recovers once the
fault is removed. In addition to the above product should be operational in the temperature
range of 0 deg to 50 deg and humidity range of 10% to 90% RH. (Note:- The manufacturer /
authorized Channel partner of the manufacturer has to submit 5 yrs free replcement
Guarantee for complete Fixture)
Estimated Rate in
Item No. Item Description Unit
113 Providing and Fixing SITC of Outdoor aesthetically designed LED Street Light Luminaire
with total consumption of Max. 90 W with single piece die cast aluminium housing, high
power LED shall be mounted on high quality metal core PCB with extremely precison
designed heat sink complete with IP66 protection Class with polycarbonate / thoughened
glass cover the fixture should be suitable for pole/bracket mounting. The fixture to comply
both LM79 and LM 80 guidelines with LED module min. 130 lumen/watt with toughen Glass
L70 at 50,000 hrs, provided with high quality polycarbonate lenses for better light
distribution. The Fixture Should be able to be Pole Mounted and also bracket mounted,
provided with high quality driver for protection against high and low Voltage cut Off,
opertional for high amibient and high humid envirnoments, THD of driver should be less
than 10% and P.F > 0.95. Also the Fixture should meet the following technical criterias
RS: Six Thousand One Hundred
Oprating range Voltage 160 to 270 V, system efficiency >= 110 lm/w, and total lumens not Each
less then 9900, CCT > 5000K, CRI > 65, beam angle 120 deg, 4kV integral & non integral surge
immunity level at least 10 KV non integral..The Separate Potted driver should have over
current, over voltage protection, short circuit protection so that the fixture recovers once the
fault is removed. In addition to the above product should be operational in the temperature
range of 0 deg to 50 deg and humidity range of 10% to 90% RH. (Note:- The manufacturer /
authorized Channel partner of the manufacturer has to submit 5 yrs free replcement
Guarantee for complete Fixture)
Estimated Rate in
Item No. Item Description Unit
114 Providing and Fixing SITC of Outdoor aesthetically designed LED Street Light Luminaire
with total consumption of Max. 120 W with single piece die cast aluminium housing, high
power LED shall be mounted on high quality metal core PCB with extremely precison
designed heat sink complete with IP66 protection Class with polycarbonate / thoughened
glass cover the fixture should be suitable for pole/bracket mounting. The fixture to comply
both LM79 and LM 80 guidelines with LED module min. 130 lumen/watt with toughen Glass
L70 at 50,000 hrs, provided with high quality polycarbonate lenses for better light
distribution. The Fixture Should be able to be Pole Mounted and also bracket mounted,
provided with high quality driver for protection against high and low Voltage cut Off,
opertional for high amibient and high humid envirnoments, THD of driver should be less
than 10% and P.F > 0.95. Also the Fixture should meet the following technical criterias
Oprating range Voltage 160 to 270 V, system efficiency >= 110 lm/w, and total lumens not RS: Six Thousand Seven Hundred
less then 13200, CCT > 5000K, CRI > 65, beam angle 120 deg, 4kV integral & non integral
surge immunity level at least 10 KV non integral..The Separate Potted driver should have
over current, over voltage protection, short circuit protection so that the fixture recovers once
the fault is removed. In addition to the above product should be operational in the
temperature range of 0 deg to 50 deg and humidity range of 10% to 90% RH. (Note:- The
manufacturer / authorized Channel partner of the manufacturer has to submit 5 yrs free
replcement Guarantee for complete Fixture)
Estimated Rate in
Item No. Item Description Unit
115 SITC of Outdoor aesthetically designed LED Flood Light Luminaire with total consumption
of maximum 48 W with single piece die cast aluminium housing, high power LED shall be
mounted on high quality metal core based PCB with extremely precison designed heat sink,
complete with IP66 protection Class, with polycarbonate / Toughened glass cover. The
fixture should be suitable for pole/bracket mounting. The fixture to comply both LM79 and
LM 80 guidelines with LED minimum 130 lumen/watt with L70 at 50,000 hrs, provided with
high quality polycarbonate Seperate lenses for better light distribution. The Fixture Should be
able to be Pole Mounted and also bracket mounted, provided with high quality potted driver
for protection against, high and low Voltage cut Off, opertional for high amibient and high
humid envirnoments, THD of driver should be less than 10% and P.F > 0.95. Also the Fixture RS: Five Thousand Three Hundred
should meet the following technical criterias. Operating range Voltage 160 to 270 V, system Forty Three only
efficiency > 110 lm/w, CCT > 5000K, CRI >65, beam angle 120 deg,4kV integral & non
integral surge immunity level at least 10 KV non integral.. Flood Light lumens shall be more
than 5280 (Note:- The manufacturer / authorized Channel partner of the manufacturer has to
submit 5 yrs free replcement Guarantee for complete Fixture)
Estimated Rate in
Item No. Item Description Unit
116 SITC of Outdoor aesthetically designed LED Flood Light Luminaire with total consumption
of maximum 60 W with single piece die cast aluminium housing, LED's mounted on high
quality metal core based PCB with extremely precison designed heat sink, complete with IP66
protection Class, with polycarbonate / Toughened glass cover. The fixture should be suitable
for pole/bracket mounting. The fixture to comply both LM79 and LM 80 guidelines with LED
minimum 130 lumen/watt with L70 at 50,000 hrs, provided with high quality polycarbonate
Seperate lenses for better light distribution. The Fixture Should be able to be Pole Mounted
and also bracket mounted, provided with high quality potted driver for protection against,
high and low Voltage cut Off, opertional for high amibient and high humid envirnoments,
THD of driver should be less than 10% and P.F > 0.95. Also the Fixture should meet the RS: Five Thousand Seven Hundred
following technical criterias. Operating range Voltage 160 to 270 V, system efficiency > 110 Forty Four only
lm/w, CCT > 5000K, CRI >65, beam angle 120 deg, 4kV integral & non integral surge
immunity level at least 10 KV non integral... Flood Light lumens shall be more than
(Note:- The manufacturer / authorized Channel partner of the manufacturer has to submit
yrs free replcement Guarantee for complete Fixture)
Estimated Rate in
Item No. Item Description Unit
117 SITC of Outdoor aesthetically designed LED Flood Light Luminaire with total consumption
of maximum 90 W with single piece die cast aluminium housing, LED's mounted on high
quality metal core based PCB with extremely precison designed heat sink, complete with IP66
protection Class, with polycarbonate / Toughened glass cover. The fixture should be suitable
for pole/bracket mounting. The fixture to comply both LM79 and LM 80 guidelines with LED
minimum 130 lumen/watt with L70 at 50,000 hrs, provided with high quality polycarbonate
Seperate lenses for better light distribution. The Fixture Should be able to be Pole Mounted
and also bracket mounted, provided with high quality potted driver for protection against,
high and low Voltage cut Off, opertional for high amibient and high humid envirnoments,
THD of driver should be less than 10% and P.F > 0.95. Also the Fixture should meet the RS: Six Thousand Two Hundred
following technical criterias. Operating range Voltage 160 to 270V, system efficiency > 110 Twenty Eight only
lm/w, CCT > 5000K, CRI >65, beam angle 120 deg, 4kV integral & non integral surge
immunity level at least 10 KV non integral... Flood Light lumens shall be more than
(Note:- The manufacturer / authorized Channel partner of the manufacturer has to submit
yrs free replcement Guarantee for complete Fixture)
Estimated Rate in
Item No. Item Description Unit
118 SITC of Outdoor aesthetically designed LED Flood Light Luminaire with total consumption
of maximum 120 W with single piece die cast aluminium housing, LED's mounted on high
quality metal core based PCB with extremely precison designed heat sink, complete with IP66
protection Class, with polycarbonate / Toughened glass cover. The fixture should be suitable
for pole/bracket mounting. The fixture to comply both LM79 and LM 80 guidelines with LED
minimum 130 lumen/watt with L70 at 50,000 hrs, provided with high quality polycarbonate
Seperate lenses for better light distribution. The Fixture Should be able to be Pole Mounted
and also bracket mounted, provided with high quality potted driver for protection against,
high and low Voltage cut Off, opertional for high amibient and high humid envirnoments,
THD of driver should be less than 10% and P.F > 0.95. Also the Fixture should meet the RS: Seven Thousand Three Hundred
following technical criterias. Operating range Voltage 160 to 270 V, system efficiency > 110 Ninty Five only
lm/w, CCT > 5000K, CRI >65, beam angle 120 deg, 4kV integral & non integral surge
immunity level at least 10 KV non integral... Flood Light lumens shall be more than
(Note:- The manufacturer / authorized Channel partner of the manufacturer has to submit
yrs free replcement Guarantee for complete Fixture)
Estimated Rate in
Item No. Item Description Unit
119 SITC of Outdoor aesthetically designed LED Flood Light Luminaire with total consumption
of maximum 240 W with single piece die cast aluminium housing, LED's mounted on high
quality metal core based PCB with extremely precison designed heat sink, complete with IP66
protection Class, with polycarbonate / Toughened glass cover. The fixture should be suitable
for pole/bracket mounting. The fixture to comply both LM79 and LM 80 guidelines with LED
minimum 130 lumen/watt with L70 at 50,000 hrs, provided with high quality polycarbonate
Seperate lenses for better light distribution. The Fixture Should be able to be Pole Mounted
and also bracket mounted, provided with high quality potted driver for protection against,
high and low Voltage cut Off, opertional for high amibient and high humid envirnoments,
THD of driver should be less than 10% and P.F > 0.95. Also the Fixture should meet the RS: Ten Thousand Nine Hundred
following technical criterias. Operating range Voltage 160 to 270V, system efficiency > 110 Eleven only
lm/w, CCT > 5000K, CRI >65, beam angle 120 deg,4kV integral & non integral surge
immunity level at least 10 KV non integral... Flood Light lumens shall be more than
(Note:- The manufacturer / authorized Channel partner of the manufacturer has to submit
yrs free replcement Guarantee for complete Fixture)
Estimated Rate in
Item No. Item Description Unit
120 Supplying and erecting Servo Controlled Voltage Stabilizer (SCVS) as per following requirement:
(1) Input Voltage Range - Three Phase 340 To 480 Volt AC. (2) Out put Volatge - Three Phase
Volt AC (Line - Line) with Voltage Regulation of +/- 1%. (3) Frequency range - 47 Hz To 63 Hz.
(4) Efficiency - More or equal to 98%. (5) Type of Stabilizer - Suitable for Balance & Unbalance
Load and Voltage including SPD (6) Controlled Type - Digital Micro Controller Based Disply. (7)
Rate Of Correction - Upto 100 Volt / Sec (Line - Line) (8) Servo Motor Drive - AC Syncronous
Stepper Motor - As per KVA Capacityy, Out put volatge and Voltage regulation requirement. (9)
Nil Wave form Distortion and Effect of Load POwer. (10) Responce Time - 10 milli second. (11)
Protection requirements - Input low Cut off protection / Input High Cut Off Protection / Output
Low Cut Off protection / IOutput High (12) Fault Annuciation Panel LED shows Input present,
Input high Input low, Output Normal, Output High, Outpur low, Overload. (13) Output On time
delay - 10 seconds (14) Ambient Tempeature capacity - 0 - 45 RH upto 90 %. (15) Enclosure Type -
IP20 (16) Type of Cooling - Oil/Air ,Output:Bypass switch with changeover switch, & 5 year
free replacement guarantee on Stamp paper.
Loading and unloading of above item shall be done by hydra and skill work force under
supervision of electrical engineer and guidelines given by manufacturer to avoid damage to the
item. Picture of it to be submitted in running bill / final bill.Size of door and Ele. room / Pump
room shall be checked by agency's engineer before giving order. If found any problem in size
discuss with GSPHCL engineer for rectification before giving order.
(make - Fuji-Electric,Servomax,,Krykard )
[a] 10 KVA (Air Cooled) RS: Fifty Eight Thousand Three
Hundred Sixty Three only
[b] 15 KVA (Air Cooled) RS: Sixty Two Thousand Three
Hundred Eighty Eight only
[c] 20 KVA (Air Cooled) RS: Sixty Six Thousand Four
Hundred Thirteen only
[d] 25 KVA (Air Cooled) RS: Seventy Two Thousand Four
Hundred Fifty only
Estimated Rate in
Item No. Item Description Unit
[e] 30 KVA (Air Cooled) RS: Seventy Nine Thousand Six
Hundred Thirty Eight only
(e) 35 KVA (Air Cooled) RS: Eighty Six Thousand Two
Hundred Fifty only
[f] 40 KVA (Air Cooled) RS: Eighty Seven Thousand Nine
Hundred Seventy Five only
[g] 50 KVA (Air Cooled) RS: Ninty Seven Thousand Seven
Hundred Fifty only
121 Supplying and erecting approved make single phase servo controlled voltage stabilizer
suitable for input voltage range 180/25OV. And output voltage range 225/235V. A.C.
RS: Seven Thousand Three Hundred
complete erected. (c) 4.0 KVA Single Phase. (Fuji Electric, Servomax Limited, Krykard, Each
Seventy Four only
Microtech Make)
122 supplying & erecting 30W LED POST TOP LATTERN fitting with high power white LEDs
wattage of 1 ww and above assebled on single MCPCB's effiency more than 130 lumens per
watt and corrosion free high pressure diecast alluminium housing with smooth finish powder
caoted and heat sink extruded alluminium with difuser and poly carbonate optics/ lences
with compny mark / name /engraved or embossed 160 to 270 volt, power factor more than
0.95, THD < 10%, CCT 5000K to 5700K , Uniformity ratio > 0.45, Luminure efficency Min
lumens per watt. LED Driver efficency > 85%. Cree/osram/philips Lumileds/Nichia
/Seoul/Bridge Lux (USA) make LED used for luminare ( Each Fitting required LM 79 and RS: Four Thousand Fifty Two
LM-80 certificates) (B) Flood Light(IP-65)Surge-10KV.(E)Post Top Latern LED Fitting only
Comprises of 650 MM TOP diameter 120 degree beam angle with 3 Nos supporting ribs
proposed for garden & Promenade. maximum 30 WATT, (Note:- The
manufacturer/authorized Channel partner of the manufacturer has to submit 5 yrs free
replcement Guarantee for complete Fixture)
123 Providing and erecting Miniature circuit breaker single pole 6A to 32A suitable to operate on
240 V A.C. system and having breaking capacity 10 KA to be erected in existing box.
confirming to IS 8828/1996 with ISI Mark. Cat III Each 111.00 RS: One Hundred Eleven only
Estimated Rate in
Item No. Item Description Unit
124 Supplying & fixing box for housing ELCB + MCB combination made of 18 SWG sheet steel
duly powder coated with gasket, dust & vermin proof bakelite shield two earthing terminals
for following type of RCCB, ELCB, ELCB + MCB
[a] For 2 pole RS: Two Hundred Seventy Two
[b] For 4 Pole RS: Four Hundred Forty Two
125 Providing & erecting approved make street light / wall mounting junction box compression
moulded from SMC (thermoset plastic) vertical sliding cover having locking with square
head stud loop in / loop out in built terminal suitable for four core cable, waterproof of I.P.
protected with clamp or bolt nut & earth bolt of following size.
[a] 200mm x 127mm x 83 mm RS: Three Hundred Fifty Three
Each 610.00 RS: Six Hundred Ten only
[c] 327mm x 254mm x 120 mm RS: One Thousand Twenty Two
126 [a] Dismantling the existing light, fan, bell, , independent plug point, wiring with mains of all
types along with accessories etc. complete and handed over to dept.
Each 1.00 RS: One only
[b] Refilling the holes for dismantled point with cable with cement mortar & finishing in an
approved manner. Each 9.00 RS: Nine only
[c] Dismantling the existing cables of all types & sizes
Each 6.00 RS: Six only
[d] Dismantling the existing switchgears, DB and Busbar of any size complete with / without
board or angle iron frame. Each 7.00 RS: Seven only
Estimated Rate in
Item No. Item Description Unit
[e] Dismantling the existing ceiling fan / exhaust fan / cabin fan / bracket fan complete with
accessories, G.I. down rod, frame etc. and making the site clear. Each 9.00 RS: Nine only
[f] Dismantling the existing pole up to 6 m height with brackets, clamps, insulators, stay from
the cement concrete foundation and making the site clear by refilling the pits with excavated RS: One Hundred Eighty Three
materials and bringing it to the ground level. Each
[g] Dismantling the existing pole above 6 m height with brackets, clamps, insulators, stay from
the cement concrete foundation and making the site clear by refilling the pits with excavated
Each 212.00 RS: Two Hundred Twelve only
materials and bringing it to the ground level.
[h] Dismantling the existing any type of indoor light fittings Each 5.00 RS: Five only
[i] Dismantling the existing any type of street light fittings on pole up to 6 mt height with
bracket and making the site as original complete. Each 13.00 RS: Thirteen only
[j] Dismantling the existing any type of fittings above 6 mt height pole from pole with bracket
complete. Each 26.00 RS: Twenty Six only
Executive Engineer (Ele.)
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
RAW_HTML
Schedule B.pdf
4 ELECTRICAL BOOKLET.pdf
NIT-23 [2025-26].pdf
percentage rate formate.pdf
SBD ARC.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .