| 1 | L1₹9.9 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹11.0 L+₹59,540 (5.70%)Rejected-Finance 101 VRAJ APARTMENT OPP POLICE HEAD QUARTER SARU SECTION ROAD JAMNAGAR 361008 | JAMNAGAR | JAMNAGAR | GUJARAT | 361008 | L2 | Rejected-Finance Being L2 | |
| 3 | L3₹11.2 L+₹77,600 (7.43%)Rejected-Finance MAHAMUNI PARA BOGAFA P S P O SANTIRBAZAR SOUTH TRIPURA | GOMATI | TRIPURA | 799125 | L3 | Rejected-Finance Being L3 | |
| 4 | L4₹12.2 L+₹1.8 L (17.1%)Rejected-Finance 0 BADRI ELECTRICALS NEAR SHRIGOR FALI NEAR ANADABAWA CHAKLO JAMNAGAR GUJARAT 361001 | JAMNAGAR | GUJARAT | 361001 | L4 | Rejected-Finance Being L4 | |
| 5 | Rejected-Technical 9 CRYSTAL COMPLEX NR D MART GANGESHWAR MAHADEV ROAD ADAJAN SURAT SURAT GUJARAT 395009 | SURAT | GUJARAT | 395009 | - | Rejected-Technical Requisite docus not submitted |
Tender Value
₹14 L
EMD Value
₹28,000
Closing Date
25 Oct 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE AF BARODA
GE AF BARODA PO DARJIPURA BARODA 390022
REPAIR / MAINT OF SUMMER APPLIANCES AT MAKARPURA AT AF STN BARODA
2021_MES_478693_1
8648/E8
Open Tender
Electrical and Maintenance Works
Item Rate
335 days
GE AF BARODA
AS PER TENDER DOCUMENTS AND NIT
3 documents required · 3 mandatory
₹500
GE AF BARODA
₹28,000
Yes
24 Dec 2021
29 Sept 2021
27 Oct 2021
29 Sept 2021
25 Oct 2021
13 Oct 2021
30 Sept 2021 - 5 Oct 2021
60 days
Amount
Material and labor for replacement of unserviceable cut sealed compressor of window type/split type ACs 1.5TR capacity with new uncut sealed hermetically compressor unit supplied by the manufacturer complete unit including wiring as required to unit with flushing out system checking and rectification of leakage, including gas charging complete and testing after completion of work at MES store yard for satisfactory functioning NOTE:- (i) The rate quoted by the contractor shall be inclusive of all charges like transportation, fitting etc complete with necessary guarantee period as per company terms & conditions (ii) The new compressor unit will be purchased from authorized dealers only as per existing make and model
Material and labor for replacement of unserviceable cut sealed compressor of split type ACs 2TR capacity with new uncut sealed hermetically compressor unit supplied by the manufacturer complete unit including wiring as required to unit with flushing out system checking and rectification of leakage, including gas charging complete and testing after completion of work at MES store yard for satisfactory functioning-: NOTE:- (i) The rate quoted by the contractor shall be inclusive of all charges like transportation, fitting etc complete with necessary guarantee period as per company terms & conditions. (ii) The new compressor unit will be purchased from authorized dealers only as per existing make and model
Material and labor for replacement of unserviceable cut sealed compressor of split type Invertors ACs 1.5/2TR capacity with new uncut sealed hermetically compressor unit supplied by the manufacturer complete unit including wiring as required to unit with flushing out system checking and rectification of leakage, including gas charging complete and testing after completion of work at MES store yard for satisfactory functioning NOTE:- (i) The rate quoted by the contractor shall be inclusive of all charges like transportation, fitting etc complete with necessary guarantee period as per company terms & conditions. (ii) The new compressor unit will be purchased from authorized dealers only as per existing make and model
Material and labor for rewinding of blower motor of Speed 900 RPM of window/Split Air conditioner of cap. 1.5/ 2 ton any make with super enameled copper conductor including replacement of worn out bushes ,Shaft and capacitor etchant testing complete all as specified and directed
Material and labour for replacement of Swing motor for indoor unit of window/Split Air conditioner of cap 1.5/2 TR and complete all as specified and directed
Material and labour for replacement of condensor fan motor of Speed 900 RPM of window/Split Air conditione rcomplete all as specified and directed
Supply and fixing running capacitor clip type of cap. 50/2+4+6 MFD, 240 volts 50 cycles for window type/Split type air conditioner 1.5 Ton.complete all as specified and directed
Supply and fixing over load protector with relay No 1622/2085 for 1.5 Ton cap for window type AC.complete all as specified and directed
Material and labour for replacement of thermostat switch for AC cap.1.5/2.00 ton capacity.complete all as specified and directed
Material and labour for replacement of defective wiring set (with suitable copper wire) of window type AC cap. 1.5 Ton/2 Ton complete all as specified and directed
Material and labour for replacement of defective wiring set (with suitable copper wire) of split type AC cap. 1.5 Ton/2 Ton (Both indoor and outdoor unit complete all as specified and directed
Material and labour for flushing out system, checking and rectification of leakages if any and make it serviceable incl. gas charging with refrigerant R-22 , oil charging complete in compressor window type AC/ Split type AC cap.1.5/2 Ton all as directed & with entire satisfaction complete all as specified and directed Note: Once the system is repaired and gas is charged, the contractor shall stand responsible for any leakage and recharging of gas for next one year from the date of repair without any extra cost.
Material and labour for flushing out system, checking and rectification of leakages if any and make it serviceable incl. gas charging with refrigerant R -32 , oil charging complete in compressor window type AC/ Split type AC cap.1.5/2 Ton all as directed & with entire satisfaction complete all as specified and directed Note: Once the system is repaired and gas is charged, the contractor shall stand responsible for any leakage and recharging of gas for next one year from the date of repair without any extra cost.
Material and labour for flushing out system, checking and rectification of leakages if any and make it serviceable incl. gas charging with refrigerant R-410 , oil charging complete in compressor window type AC/ Split type AC cap.1.5/2 Ton all as directed & with entire satisfaction complete all as specified and directed Note: Once the system is repaired and gas is charged, the contractor shall stand responsible for any leakage and recharging of gas for next one year from the date of repair without any extra cost.
Material and labour for replacement of cooling coil for indoor unit split type AC Cap.1.5 /2.0 TR complete all as specified and directed
Material and labour for replacement of copper condenser unit (Heating Condenser) for out door unit for split type AC Cap.1.5 /2.0 TR complete all as specified and directed
Material and labour for chemical wash for indoor/out door unit for split /window type AC Cap.1.5 /2.0 TR complete all as specified and directed
Material and labour for replacement of cooling coil for window type AC Cap.1.5 /2.0 TR complete all as specified and directed
M/L for replacement of blade of condensing fan motor (as per sample) for window/split type (outdoor unit) AC cap 1.5/2.0 Ton.complete all as specified and directed
Material and labour for taking out window type AC from site of any cap.and make for servicing incl. cleaning with air blower , cleaning and washing fins of cooling coil with caustic soda mixed water, taking out all dirt , sludge deposited, cleaning of air filter incl. oiling / greasing of condensing fan motor , spray painting of outer cover with 2 coats of synthetic enameled paint of approved colour as directed with writing of serial No SM/MES No. and reinstalled the AC in position with fixing of putty etc. complete all as specified and directed (Note : Any damage occurred during repair for which contractor will be responsible to rectify defects without any cost to the Govt).
S&F in repairs of following unserviceable items in existing split type AC of existing make complete all as specified and directed
Connector unit
Foam type insulating flexible pipe fitted on suction /discharge copper tubes.
PCB Card for split type AC of capacity 1.5 TR
PCB Card for split type AC of capacity 2 TR
Remote hand set for split type AC 1.5/2 TR Capacity
Valve 1/2 " ,1/4 " and 5/8 " for split type of capacity 1.5/2.0 TR
Cooling coil and room temperature sensor
Display unit for 1.5/2 Ton AC
Blower motor of indoor unit of split type of cap 1.5 /2 TR as per existing make/mode complete all as specified and directedl
copper pipe of size 1/4 " from outdoor unit to indoor unit including soldering and brazing complete all as specified and directed
copper pipe of size 1/2 " from outdoor unit to indoor unit including soldering and brazing complete all as specified and directed
copper pipe of size 5/8 " from outdoor unit to indoor unit including soldering and brazing complete all as specified and directed
Material and labour for refixing split type of capacity 1.5/2 TR from one site to another site complete all as specified and directed
Material and labour for replacement of PT relay for split type Acs of Capacity 1.5/2 TR as per existing make complete all as specified and directed
Material and labour for replacement airfilter for split type ac for 1.5/2 TR complete all as specified and directed
Material and labour for replacement out unit jali for split type ac for 1.5/2 TR complete all as specified and directed
Material and labour for replacement Outdoor fan motor as per existing for 2.0 Ton Spilt AC complete all as specified and directed
Material and labour for replacement Outdoor fan motor as per existing for 1.5 Ton Split AC complete all as specified and directed
Material and labour for replacement Compresser Capacitor as per existing for 1.5/2.0 Split type AC complete all as specified and directed
Material and labour for replacement Swing Patti as per existing for 1.5/2.0 Split type AC complete all as specified and directed
Material and labour for replacement Drain pipe as per existing for 1.5/2.0 Split type AC complete all as specified and directed
Material and labour for replacement Drain tray as per existing for 1.5/2.0 Split type AC complete all as specified and directed
Material and labour for replacement PCB Transformer as per existing for 1.5/2.0 Split type AC complete all as specified and directed
Material and labour for replacement PCB for 1.5/2.0 Ton Invertor type AC as per existing complete all as specified and directed
Material and labour for replacement Fan motor of 1.5/2.0 Ton split type invertor Acs as per existing complete all as specified and directed
Material and labour for replacement outdoor heating condenser of 1.5/2.0 Ton split type invertor Acs as per existing complete all as specified and directed.
Material and labour for replacement Sensor of 1.5/2.0 Ton split type invertor Acs as per existing complete all as specified and directed.
Material and labour for replacement Control remote of 1.5/2.0 Ton split type invertor Acs as per existing.complete all as specified and directed
Material and labour for replacement of electrical wiring two run of single core 6 sq mm (Nominal area) multithreaded copper conductor PVC insulated sheathed cable including one 4 Sq mm solid copper conductor PVC insulated cable in and including 20 mm dial rigid metallic conduit complete including junction boxes with metallic sheet top cover and other accessories complete all as specified and directed NOTE:- Two run of main wire, one run of earth wire and pipe shall be measured as one length.
Material and labour for replacement of single pole and neutral enclosure with 2 pin earth industrial plug and socket complete with one MCB SP 25 Amps complete all as specified and directed
Material and Labour for replacement of unserviceable hermitically sealed compressor suitable for water cooler cooling capacity 40 liters/hour with new uncut sealed compressor supplied by manufacture complete. (Makes :-Tecumesh/Kirlosker copeland ) Note:- i) Old sealed compressor received from the water cooler will be property of contractor ii) The ate quoted by the contractor including all charges like transportation , filling oil & gas charging incl flushing out system ,checking and rectification of leakage etc and testing complete up to entire satisfaction of Engr-in-charge with necessary guarantee period as per the company terms and condition iii ) The new sealed unit will be purchased from authorized dealer.
Material and Labour for Replacement of copper filter and capillary tube of water cooler cooling capacity 40 Ltr/hr complete all as specified and directed
Material and Labour for Replacement of relay with over load protectors for 40 Ltr/hr cooling capacity suitable as per site requirement complete all as specified and directed
Material and Labour for Replacement of condensor fan of motor HP- 1/32 ,RPM-1300 suitable for water cooler having cooling cap 40 Ltr/hr with clips and motor fixing stand with fan blade. complete all as specified and directed
Material and Labour for Replacement of thermostat switch with knob for water cooler. having cooling capacity 40 Ltrs / hr complete all as specified and directed ( Make : Renutrol no 1051 or Indofoss No2064/Annapurna )
Material and Labour for Replacement of starting capacitor 40/60 Mfd oil filled 240 volt AC Supply complete all as specified and directed Make ; Tesla
Material and Labour for Replacement of running capacitor of 10 Mfd oil filled complete all as specified and directed Make: Asian/ Atlas/Epcos/SPAN/Sharda
Material and Labour for Replacement of capacitor of 3 Mfd complete all as specified and directed Make: Asian/ Atlas/Epcos/SPAN
Material and Labour for brass float valve 15 mm bore with PVC float, ball I.S.I Marked complete with check nut /socket/GI nipple complete all as specified and directed
Material and Labour for replacement of top cover of water cooler with rubber beading, hinges screws etc complete for 40 Ltr/Hr cap. water cooler complete all as specified and directed
Material and Labour for rewinding of condensing fan motor of water cooler (1/35 HP) cap. 40 Ltr/Hr with supper enameled copper wire of suitable gauge (Make: Devidayal/Chetak/Atlatcomplete incl. insulating material and replacement of gun metal bush & capacitor 2.5 MFD. complete all as specified and directed ( Make:Epcos/Asian /Unistar)
Material and labour for replacement of fan blade for condensing fan motor (as per sample) suitable for water cooler having cooling capacity 40 Ltr/Hr water cooler. complete all as specified and directed
Material and Labour for condenser unit complete suitable for 40 Ltr/Hr cap. water cooler repairs of leakages in system including gas charging flushing out the system brazing, welding and jointing the suction reed and discharge reed complete all as specified and directed
Material and labour for flushing out system, checking and rectification of leakages if any and make it serviceable incl. gas charging with suitable refrigerant, oil charging complete in compressor of water coolar all as directed & with entire satisfaction complete all as specified and directed Note: Once the system is repaired and gas is charged, the contractor shall stand responsible for any leakage and recharging of gas for next one year from the date of repair without any extra cost.
Material and labour for rewinding of Desert Cooler fan motor 3 speed,1400 RPM any make of cap. 1/5 HP with super enameled copper wire of appropriate size . Make: DEVIDAYAL /CHETAK complete incl. replacement of bush, shaft and oil filled capacitor 4 MFD,240 volts of complete all as specified and directed Make: Unistar / Kell/ Asian/ Siemens.
Material and labour for replacement of oil filled type capacitor for fan motor cap. 4 MFD , 240 volts complete all as specified and directed suitable for desert cooler fan motor . Make: Unistar/ KELL /Asian/Siemens/Jyoti .
Material and Labour for replacment of Bottom water tank of size 750x750x200 mm fabricated out of 18 gauge PGI sheet.incl nuts bolts and washers etc complete all as specified and directed
Material and labour for replacement of side supporting columns to be fabricated out of 20 gauges PGI sheet of size 80x80x800 mm incl. necessary nut, bolts etc . complete all as specified and directed
Material and labour for replacement of side penal made out of 22 gauge PGI Sheet with suitable handles including painting to match with the existing desert cooler complete all as specified and directed
Material and labour for replacement of top cover made out of 22 gauge PGI Sheet including painting to match with the existing desert cooler complete all as specified and directed
Material and labour for painting to old steel surfaces of Desert cooler up to 5000 cfm with two coats of synthetic enamel spray paint over one coat of red oxide on external surface & two coats of anti corrosive black paint inside the Body tank & side grills over a coat of Red Oxide on internal surfaces including scraping/rubbing with wire brush on old surface of Desert cooler. and writing of MES NO etc complete all as specified and directed
Material and labour replacement of submersible pump of discharge head 2.5 Mtr 220-240 Volts AC Supply single phase 40 watt complete all as specified and directed
Material and labour for replacement of Wood / wool chips pad for Desert Cooler of size 00 x 550 x30 mm (set of three pads) superior quality . complete all as specified and directed
Material and labour for replacement of supporting jali of wood/wool chips pad set made out of hard MS wire and fitted in side louvers complete all as specified and directed
Material and labour for replacement of PVC insulated and PVC sheathed cable copper conductor 3 core 23/0.0076 cross sectional area superior quality complete all as specified and directed
Material and labour for replacement of PVC water distributor of 3 out lets with MS nuts & bolts complete (as per sample) complete all as specified and directed
Material and labour for replacement of PVC elbow suitable for desert cooler (as per sample) complete all as specified and directed
Material and labour for replacement of PVC pipe 15 mm dia heavy duty for D/Cooler Pump complete all as specified and directed
Material and labour for replacement of 3 pin plug top cap 5 Amp AC 240 Volts 50 Hz complete all as specified and directed
Material and labour for replacement of motor fixing ring for desert cooler eight screw / clip type(asper sample) complete all as specified and directed
Supply and fix in repair voltage stablizer for automatic operation single phase naturally air cooled indoor type having low and high voltage cut-off protection, inbuilt thermal protection & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy +/- 2.5% and of capacity of 5 KVA wall mountable.complete all as specified and directed.Make: V guard VND 500 or equivalent in blue bird or microtech complete all as specified and directed. Note: rates for fixing of existing ACs and power supply via volatge stabilizer deemed to be considered in quoted rates.
Material and labour for taking out deep frezzer of any size and any make to the workshop for general body work repairs including patch work and hinges and locking work complete after removing rusted part and repairing complete fabrication work what ever is required complete making it in good presentable condition after painting work complete all as specified and directed Note: Rates for transportation to and fro from site to workshop shall be deemed to be included in the quoted rates.
Material and Labour for flushing of system , testing and repairs of leakages in system charging of Gas(between inner cooling cabin and outer fabrication) , Oil complete incl. testing and commissioning of deep frezzer of capacity upto 300 Ltrs of any make complete all as specified and directed Note: Spares to be used in repair,gas charging and transportation to workshop and back to site shall be deemed to be included in the quoted rates.
Material and Labour for replacement of unserviceable hermitically sealed compressor suitable for deep freezer of capacity 300 Ltrs with new uncut sealed compressor supplied by manufacture complete. (Makes :-Tecumesh/Kirlosker copeland ) Note i) Old sealed compressor received from the water cooler will be property of contractor (ii) The rate quoted by the contractor including all charges like transportation, filling oil & gas charging incl flushing out system ,checking and rectification of leakage etc and testing complete up to entire satisfaction of Engr-in-charge with necessary guarantee period as per the company terms and condition. ( iii ) The new sealed unit will be purchased from authorized dealer.
Supply only Desert cooler metal body tank capacity 50ltrs fan rpm 1275 rpm heavy duty copper wound single phase motor cooling media as as per overall size 650mm X 650mm X 800mm consisting of thick metal sheet with inbuilt flotvalve 18 inch anti corresive painted fan & motor body complete and large pad area with heavy duty water circulating submercible pump with flexible pipe,delivers & acessories and power consumtipion 230V 50 Hz 235 watt complete, miniumum 2 years warranty by the dealer complete all as specified and directed
Material and labour for replacement of unserviceable hermitically sealed compressor of Refrigerator 310/280 Ltr. Capacity with fresh new uncut sealed compressor including +suitable relay and over load with new sealed unit as per the company scheme supplied by the manufacturer complete including flushing out system, checking and rectification of leakage, gas charging, complete and testing after completion of work at MES Store yard for satisfactory function. Note:- (i) The rate quoted by the contractor shall be inclusive of all charges like transportation, fitting etc complete with necessary guarantee period as per company terms and conditions. (ii) The new unit will be purchased from authorized delar Make: Carrier/Voltas
All as per ser item No82 above but for 165/170/180 Ltr capacity refrigerator .Make. Carrier/Voltas
Material and labour for replacement of relay suitable for 280/310 Liters cap.refrigerator (Make:- Renutrol/Shriram/Anpurna/KLIXON)
all as per ser item No 84 but cap 165 Liters complete all as specified and directed
Material and labour for replacement of thermostat automatic `R' frost with knob suitable for 165/286/310 liters cap refrigerator (Make :-Anpurna/Indofos)
Material and labour for replacement of door gasket of best quality complete suitable for 280/310 liters cap. refrigerator as per manufacturer's instruction complete all as specified and directed
All as per ser item No.87 above but for 165 Ltrs Cap. complete all as specified and directed
Material and labour for replacement Bulb for pin /screw type , 230 Volts suitable for 286/310 Ltrs Cap. Refrigerator complete all as specified and directed
Material and labour for preparation of surfaces and painting with applying two coats of synthetic enamel paint old painted on external surfaces of refrigerator except cooling coil and the compressor unit which will be painted with two coats of heat resistant black paint for 286/310 ltrs capacity refrigerator including writing of the words in height unto 4cm i.e. SM No MES No complete all as specified and directed. (Note: Refrigerators to be painted at different locations of different units)
All as per ser item No.90 above but 165 Ltrs capacity.refrigerator complete all as specified and directed
Material and labour for replacement of refrigerator door handle of 165/ 286/310 Ltrs Cap. of any make.and model complete all as specified and directed
Material and labour for replacement of freezer assy (including gas charging R-134/600 ) complete with screw, jointing of tubes etc. and testing of cap. 280/310165 Ltrs. refrigeratorcomplete all as specified and directed
All as per ser item No.93 above but of capacity 165/175 Ltr refrigeratorcomplete all as specified and directed
Material and labour for replacement of condensor unit of refrigerator cap. 280/310 Ltrs of any make including jointing of tubes and testing etc. complete all as specified and directed.(gas charging will be measure and paid under relevant item separately )
All as per ser item No.95 above but for 165 ltrs capacity refrigerator.complete all as specified and directed
Material and labour for replacement of timer of refrigerator cap. 280/310/165 Ltrs of any make complete all as specified and directed
Material and labour for replacement of PCB of refrigerator cap. 280/310/165 Ltrs of any make complete all as specified and directed.Hitachi/Voltas
M & L for replacement of cooling coil of refrigerator cap 280/310/165 Ltrs as per existing complete all as specified and directed
M & L for replacement of capilary of refrigerator cap 280/310/165 Ltrs as per existing complete all as specified and directed
M/s SK Traders
BHARAT NIRMAN INFRASTRUCTURE COMPANY
Badri Electricals
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .