Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹18.8 LAccepted-AOC DHALESWAR JAIL ASHRAM ROAD AGARTALA TRIPURA W | DHALAI | TRIPURA | 799204 | L1 | Accepted-AOC L1 bidder selected | |
| 2 | L2₹23.2 L+₹4.2 L (21.8%)Rejected-AOC JATANBARI KARBOK GOMATI TRIPURA | L2 | Rejected-AOC L2 bidder rejected |
Tender Value
₹18.3 L
EMD Value
₹36,529
Closing Date
20 Mar 2023, 5:30 pmClosed
DGM,ED-II,Bordowali
O/o the DGM,ED-II,Bordowali
Installation of 63 KVA DT inc extension of 11 KV line by overhead and UG cable system for providing 3Phase new DTWwater resource service connection at Joykali under SM Nagar and Shivbari under KhashMadhupur GP within the jurisdiction of ESDAmtali inc
2023_POWER_36925_1
DGM/ED-II/TSECL/2022-23/32, Dt.06.03.2023
Open Tender
Electrical Works
Item Rate
90 days
under ESD-Amtali
Please refer Tender documents.
7 documents required · 7 mandatory
₹2,000
₹36,529
O/o The AGM,EC-I,Agartala
18 May 2023
7 Mar 2023
21 Mar 2023
8 Mar 2023
20 Mar 2023
15 Mar 2023
8 Mar 2023 - 13 Mar 2023
14 Mar 2023
Amount
(Supply & Erection)
Carriage of materials such as Cable,AAC, AAAC, ACSR, G.I.Wire,Cross-Arm,Stay set,Insulators etc., by Mechanical Transport from the Electrical Sub-Divisional Site Store to working site Vis-a-vis, including loading, unloading and stacking as required, Upto the lead range 25KM
Carriage of. of 9.0 mtrs & 8.0 mtr length of Steel Tubular Poles by Mechanical Transport from the Electrical Sub-Divisional Site Store to working site Vis-a-vis, including loading, unloading and stacking as required a) Upto the lead range 25 KM i) For maximum 18 (eighteen) poles
Carriage of 11/ 0.430 KV , 3-Phase 63 KVA by Mechanical Transport from the Site /Store/Workshop to working site Vis-a-vis including loading, unloading and placing on base, as required,, Beyond 25 KM upto the lead of 50KM
Carriage of GOS , DOF , LA etc., by Mechanical Transport from the Electrical Sub-Divisional Site Store to working site Vis-a-vis, including loading, unloading and stacking as required, Upto the lead range 25KM.
Carrying of the store materials from Electrical Store Sub-Division, AD Nagar, Agartala to ESD- Amtali storeyard by mechanical transport i/c loading unloading & stacking etc. Upto the lead of 25 KM
Erection of 9.0 mtrs length of Steel • Tubular POLE at any kind of soil upto a depth of 1/6 th of pole height, including excavation of earth, refilling the pit with soil upto the ground level, ramming and making complete in all respect.
Erection of 8.0 mtrs length of Steel • Tubular POLE at any kind of soil upto a depth of 1/7 th of pole height, including excavation of earth, refilling the pit with soil upto the ground level, ramming and making complete in all respect.
Erection of stay set direct in earth complete with 19 mm X 1800 mm long stay , rod, anchor , plate of size 300x300x8 mm thimble, turn bukle , 7/3.15 mm dia G.I standed stay wire and stain insulator etc.with supply of M.S clamp , nuts & bolts etc.as required and making complete in all respect.
Erection of M.S.Angle Cross-Arm, 2.8 mtr Long 65 x65 x 6 mm ( Excluding the cost of Back Clamp, Nuts & Bolts)
Erection of M.S.Angle Cross-Arm, 2.2 mtr Long 65 x65 x 6 mm ( Excluding the cost of Back Clamp, Nuts & Bolts)
Erection of M.S.Angle Cross-Arm, 1.5 mtr Long 65 x65 x 6 mm ( Excluding the cost of Back Clamp, Nuts & Bolts)
Erection of M.S.Angle Cross-Arm, 0.6 mtr Long 65 x65 x 6 mm ( Excluding the cost of Back Clamp, Nuts & Bolts)
Erection of M.S.Channel Cross-Arm,03 mtr Long 75 x40 x 40 x 6 mm ( Excluding the cost of Back Clamp, Nuts & Bolts)
Erection of M.S.Channel Cross-Arm,06 mtr Long 75 x40 x 40 x 6 mm ( Excluding the cost of Back Clamp, Nuts & Bolts)
Erection of M.S.Channel Cross-Arm,13 mtr Long 75 x40 x 40 x 6 mm ( Excluding the cost of Back Clamp, Nuts & Bolts)
Erection of M.S.Channel Cross-Arm,2.2 mtr Long 75 x40 x 40 x 6 mm ( Excluding the cost of Back Clamp, Nuts & Bolts)
Erection of M.S.Channel Cross-Arm,2.5 mtr Long75 x40 x 40 x 6 mm ( Excluding the cost of Back Clamp, Nuts & Bolts)
Erection of M.S.Channel Cross-Arm, 2.8 mtr Long 75 x40 x 40 x 6 mm ( Excluding the cost of Back Clamp, Nuts & Bolts)
Erection of M.S.Channel Cross-Arm, 2.8 mtr Long 100 x50 x 50 x 6 mm ( Excluding the cost of Back Clamp, Nuts & Bolts)
Erection of M.S.Channel Cross-Arm, 0.8 mtr Long 100 x50 x 50 x 6 mm ( Excluding the cost of Back Clamp, Nuts & Bolts)
Installation/Positioning of 11/0.430KV,3-Phase 63KVA of Distribution Transformer on Pole with necessary connections & fitting fixing of all allied accessories components as required for making complete in all respect for energizing.
Earthing with G.I pipe 2.5mtr Long and 40mm dia, including excavation, refilling with alternate layer of salt & Charcoal as per drawing including supply of G.I.Pipe, Salt & Charcoal, GI wire, nuts &bolts, etc. as required)
Erection of 11 KV Pin insulator along with Pin.
Erection of 11 KV Single Disc insulator set along with necessary fittings
Erection of shackle insulator of size 75mm x 90mm /100mm X 15mm with straps & bolts/ U-clamp on poles (Excluding the cost of straps / U- clamp, Nuts & bolts).
Laying & Stringing of 1KM (Single Conductor) ACSR 6/1/2.59 mm dia 'WEASEL' including hoisting & binding etc. Complete as required.
Laying & strining of 1 KM (Single Conductor) , 10/8SWG GI wire including hoisting & binding etc. Complete as required.
Erection of 9KV,5KA single pole metal oxide gapless type LA , including necessary connection complete as per technical specification.
Erection of 11KV DOF unit set of three nos. including necessary connection complete as per technical specification.(Excluding the cost of back clamp,Nuts & Bolts)
Erection of 11KV 200 Amp. GOS unit set of three nos. including necessary connection complete as per technical specification (Excluding the cost of back clamp,Nuts & Bolts)
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required., Trench Size: Width-350mm, Hieght-1200mm / Sand (couhioning): Hieght-250mm, Width-350mm/ Protection: Double layer Bricks, Upto 120 sq. mm
Laying of one number additional PVC insulated and PVC sheathed I XLPE power cable of 11 KV grade of following size direct in ground in the same trench in one tier horizontal formation including excavation, sand cushioning, protective covering and refilling the trench etc as required. Trench Size: Width-200mm, Hieght-1200mm I Sand(couhioning): Hieght-250mm, Width-200mm/ Protection: Double layer Bricks Upto 120 sq. mm
Laying of one number PVC insulated and PVC sheathed XLPE power cable of 11 KV grade of all size in the GI Pipe/HDPE for riser including tieup of Pipe with pole by the help MS Flat Clamp (excluding cost of Clamp and Nut&Bolts) as required Up to 400 sq. mm in/c coiling of excess XLPE cable at the top of the pole.
Providing of Pre-cast cement concretecable identification route marker (1 cement: 2 coarse sand 4 graded stone aggregate 6mm nominal size) reinforced with 1.6 mm dia mild steel wire including centring and shuttering, roughening cleaning, fixing and finishing in cement mortar 1: 3( 1 cement : 3 fine sand) etc. complete, excluding the plastering of jambs, sills and soffits as per design, drawing and specification of TSECL. The marker shall be embossed "DANGERS: TSECL, ELECTRIC POWER CABLE" with Black colour letter(both side). The visible part shall be painted with Yellow colour japan paint. (1 cement: 2 coarse sand : 4 graded stone aggregate 6mm nominal size) reinforced with 1.6 mm dia mild steel wire including centring and shuttering, roughening cleaning, fixing and finishing in cement mortar 1 :3(1cement : 3 fine sand) etc. complete, excluding the plastering of jambs, sills and soffits.
Manually digging /drilling horizontally or diagonali direction for road crossing I Water supply line/Telcomunication line/Gas Pipe line etc. including Laying of 64 to 200mm dia GI pipe direct into the earth at a depth of minimum 11OOmm below the ground surface with out effecting the existing road including excavation earth for entry pit as per site condition and direction of Engineering ln Charge
Providing Three Phase Service Connection with laying PVC cable from nearby Electrical pole to Premises upto 35mtr in length supported by G.I.Wire,Reel Insulator i/c fitting fixing of Energy Meter as required .
Maintaining adequate clearance from overhead live conductors by Trimming of tree branches for Way Leaves
Gouting of ST pole /Stay set with CC of ratio 1:2:4 (1Cement:2 river sand: 4 jhama brick aggt. Of 20mm nominal size ) in/c supply of cement, sand & brick aggt. Of 20mm nominal size complete with excavation , riffiling of earth, ramming along with centering & shuttering as reqd. @ 0.273 Cum per ST pole as per TSECL specification.
Providing Sub-station Protective fencing with heavy duty hard-drawan length : 5 mtr , width : 3.5 mtr and height : 1.5 mtr and 25x6xx6 ms angle for pillering in/c supply of necessary materials as per direction of Engineer in charge.
Supply of Wooden Plank (24"X10'X1.5"size)
Supply of fabricated MS bracket & stay Clamp (made by 50X6mm flat)
Supply of MS Nuts & Bolts (16mm dia) ( assorted size)
Supply of 1/2 " dia Polythine Pipe
Supply of 110 mm dia HDPE Pipe, wall thickness: minimum 7.4mm, maximum- 8.2mm (medium class)
Supplying of Meggar Make 5000 VA Insulation Tester
Supplying and making outdoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for 50 / 70 sq.mm ,3 core XLPE aluminium conductor cable of 11kv Graded.
Supply of XLPE Power cable 11KV Grade 3core, 70sqmm
Supply of re-wirable porcelin cutout (100Amp)
Supply of 120sqmm-10 bimetalic lugs
Supply of 95sqmm-10 bimetalic lugs
Supply of 120 sqmm Aluminium PVC cable
Supply of 35 sqmm Aluminium PVC cable
Supply of 70 sqmm Aluminium PVC cable
Supply of Straps with nuts & bolts
Supply of fabricated MS Channel as per requirement of site condition and suitable for HT/LT over head line and as directed by the Engineer-In-charge made by (100X50X50X6mm) with double coat of red oxide primer coating
Supply of fabricated MS Channel as per requirement of site condition and suitable for HT/LT over head line and as directed by the Engineer-In-charge made by (75X40X40X6mm) with double coat of red oxide primer coating
Supply of fabricated MS angle as per requirement of site condition and suitable for HT/LT over head line and as directed by the Engineer-In-charge made by (65X65X6mm) with double coat of red oxide primer coating
RATAN PAUL
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .