Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.5 CrAccepted-AOC | ₹5.5 Cr Quoted ₹5.6 Cr | L1 | Accepted-AOC Being lowest bidder |
| 2 | L2₹5.6 Cr+₹1.5 L (0.26%)Rejected-Finance 103 HARIAKSH PLAZA HOSPITAL ROAD BHUJ KUTCH GUIARAT 370001 | BHUJ | KUTCH | GUJARAT | 370001 | ₹5.6 Cr+₹1.5 L (0.26%) | L2 | Rejected-Finance Other than lowest bidder |
| 3 | L3₹5.8 Cr+₹19.4 L (3.45%)Rejected-Finance 20 SC BOSE COLONY GALL NO 2 DEFENCE LAB ROAD RATNADA JODHPUR 342001 | JODHPUR | JODHPUR | RAJASTHAN | 342001 | ₹5.8 Cr+₹19.4 L (3.45%) | L3 | Rejected-Finance Other than lowest bidder |
| 4 | L4₹6.0 Cr+₹41.0 L (7.29%)Rejected-Finance | ₹6.0 Cr+₹41.0 L (7.29%) | L4 | Rejected-Finance Other than lowest bidder |
| 5 | L5₹7.0 Cr+₹1.4 Cr (25.2%)Rejected-Finance | ₹7.0 Cr+₹1.4 Cr (25.2%) | L5 | Rejected-Finance Other than lowest bidder |
Tender Value
₹7.2 Cr
EMD Value
₹6.8 L
Closing Date
13 Jun 2020, 6:00 pmClosed
CHIEF ENGINEER JODHPUR ZONE
HQ CE Jodhpur Zone Jodhpur
ADDN ALTN UPGRADATION OF OLD MD ACCN OF OFFRS JCOs AND OR AT MIL STN DHRANGADHRA
2020_MES_341356_1
800497/GNR/2020-21/E8
Open Tender
Civil Works
Item Rate
365 days
DHRANGADHRA
As per tender documents
8 documents required · 8 mandatory
₹3,000
GE Army Gandhinagar
₹6.8 L
Yes
22 Jul 2020
28 Apr 2020
15 Jun 2020
28 Apr 2020
13 Jun 2020
6 Jun 2020
Amount
Dismantling floor hearth or wall tiling including cement mortar bedding (but not backing) removing serviceable tiles to store and rubbish off the premises complete all as specified and directed.
Dismantling stone slab and tiles of any description or thickness in floors,aprons etc.
Taking down cement or cement lime plaster, any description on stone walls etc incl raking out joints hacking for key, scrubbing down with water, etc.
Demolition of cement concrete (unreinforced) of any description and in any position not otherwise specifically provided for, such as sunken floor, roof padding etc complete all as specified and directed.
M&L for plain cement concrete 1:2:4 type B1, using 20mm graded stone aggregate as in padding on roof and finishing cement concrete surfaces even and smooth without using extra cement, complete all as specified and as directed.
Taking down of existing bituminious felts etc incl bedding layer complete all as directed.
M & L for water proofing treatment to roofs using 3mm thick APP in following stages :- (a) M & L 10mm thick bedding layer in CM 1:3 mixed with integral water proofing compound as per manufacturer's instructions and finished even & smooth complete all as specified and directed. (b) M&L applying first coat of bitumen primer conforming to IS 3384 @ 0.300 Kg/Sqm over plastered surfaces. (c) Over the primed surfaces applying a tack coat of hot Industrial bitumen grade 85/25 applied @ 1.20/Sqm. (d) Over the tack coat applied surfaces applying 3 mm thick APP modified polymeric membrane with centre core of singlenonwoven polyesterreinforcement & having weight 3 Kg/Sqm. The APP membrane shall be laid with a side overlap of minimum 75mm & end overlap of minimum 100 mm. Note : For vertical surfaces like parapets etc not exc 30 cm in height the treatment as specified above shall be taken upto the full height & over the width of the parapet wall. Where the height of the vertical surfaces of parapet wall is exc 30 cm in heigh tthe treatment shall be inserted in the wall at 30 cm height by cutting a groove of size 7.5 cm x 7.5 cm all as specified and directed at site. APP treatment shall be carried out by the authorized applicator of the manufacturer
M & L for applying two coats of Aluminium paint of over the dried & cured surfaces of APP membrane of approved make all as specified and directed by Engineer in Charge
M & L for 20-22 mm thick hydraulically pressed cement concrete tiles of size 250mm x 250mm conforming to IS 1237-1980 laid over 15mm thick bedding in cement moretar (1:4), joints grouted and flush pointed in CM (1:3) mixed with WPC as per manufacturer's instructions. The tiles shall be laid either through authorised applicator who has laid the APP membrane or by the contractor under the supervision of the authorised applicator of APP membrane.
M&L for PCC 1:5:10 type E-2 using 40mm graded aggregate for filling into sunken floors etc complete all as specified and directed.
M&L for PCC 1:2:4 type B1 using 20 mm graded stone aggregate, 40mm thick and finishing the surface rough to receive tile complete all as specified and directed.
M&L for water proofing plaster on stone masonry surface for sunken portion in CM 1:3, 15 mm thick with integral water proofing compound at the rate of 2 % by weight of cement and finishing the surface even and smooth without using extra cement.(WPC will be measured and paid seperately).
M&L for applying evenly a tack coat of industrial bitumen 85/25 at the rate of 1.2 kg per sq. m including cleaning surfaces etc complete all as specified and as directed.
Supply only integral water proofing compound
M&L for vitrified ceramic tiles light shade 10mm thick (Square/rectangular) polished, area of each tiles exceeding 0.36 sqm but not exc 0.42 sqm in floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15mm thick screed bed in CM 1:6complete all as specified and directed.
M&L for vitrified ceramic tiles light shade 10mm thick (Square/rectangular) polished, area of each tiles exceeding 0.36 sqm but not exc 0.42 sqm as in dado/skirting etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 10 mm thick backing coat in CM 1:4 complete all as specified and directed
M&L, Non-skid coloured ceramic tiles 7 to 8 mm thick (square/rectangular), area of each tiles exceeding 0.11 sqm but not exceeding 0.18sqm, in floors etc. set & jointed in net cement slurry and pointed in white or coloured cement to match over and including 15mm thick screed bed in CM 1:6 complete as specified and directed.
M&L, Non-skid coloured ceramic tiles 7 to 8mm thick (square/rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18sqm, in skirting etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 10 mm thick backing coat in CM 1:4 complete all as specified and directed
S&F, in repair, hot & cold mixer, brass chromium plated with complete fittings set, screwed for 15mm bore GI pipe complete all as specified and directed. Make- Jaquar (Cat No: CON-167 KNB) or equivalent as approved by GE.
M&L for coloured glazed ceramic tiles of size 450 x 350 x 7mm thick on vertical surface such as skirting/dado, set and jointed in neat cement slurry and pointed in coloured cement to match over 10 mm thick backing coat in CM 1:4 complete all as specified and directed.
M&L for coloured glazed ceramic tiles of size 450 x 350 x 7mm thick High lighter tiles on vertical surface such as skirting/dado, set and jointed in neat cement slurry and pointed in coloured cement to match over 10 mm thick backing coat in CM 1:4 complete all as specified and directed.
S&F, in repair, chromium plated, Toilet paper holder complete all as specified and directed. Make-Jaquar (Cat No - ACN -1153N) or equivalent as approved by GE.
M&L for machine cut kota stone slab, 550mmx550mm, 20-25mm thick as in flooring laid over and including cement mortar screed bed of 15mm thick in CM (1:6), laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and directed.
M&L for machine cut kota stone slab 18-20 mm thick as in riser of steps, skirting, dado and pillar laid over and including rendering 10mm thick in cement mortar (1:4), jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and directed.
M&L for chequered cement concrete tiles 20 cmx20 cmx25 mm thick, with grey cement and no pigment, set, jointed and pointed in neat cement slurry over and including 20 mm thick screed bed in cm (1:6) complete all as specified.
M&L for 16-18mm thick black granite stone slab (one slab in size) machine cut in skirting/dado, cooking platform, jambs, pillars, windows cills and the like laid over and including 10mm thick screed bed or backing coat in cement mortar (1:4) and jointed with grey cement slurry and pointed with white cement and with admixture or pigment to match the shade of granite stone including grinding and polishing complete all as specified & directed.
M&L for rounding to edges of stone slabs two edge full round,such as in steps,cooking platform and other similar situation complete all as specified and directed.
M&L for 50mm thick cement concrete 1:3:6 type C1, using 20mm graded stone aggregate as in plinth protection, finishing cement concrete surfaces even and smooth without using extra cement, Joints of plinth protection shall be filled with bitumen mastic (1:3) complete all as specified and as directed.
M&L for rendering 15mm thick cement plaster 1:6 on stone masonry surface or surface other than fair face of brickwork surface finished even and smooth without using extra cement.
M&L for rendering 10mm thick in CM (1:3)on fair faces of ceiling and finishing the surfaces even and smooth without using extra cement complete all as specified
M&L for 15mm thick rendering in two layers, 10mm thick in CM 1.:6 and 5mm thick in CM 1:4 incl using WPC as per manufacturer's instructions in outer layer only on stone masonry surface or surface other than fair face of brickwork surface finished even and smooth without using extra cement. (WPC shall be measued & paid for separately)
M&L for taking down , chipping and removing the loose, split damaged cement concrete, cement mortar surfaces of RCC Columns, beams, walls, chajja etc and exposing the reinforced cement , wire brushing and cleaning the exposed steel reinforced bar, applying rust remover over the cleaned re-bar surface wash the re-bar with clean water for removing all rusts from the old re-bar surfaces, fixing new reinforcement for strengthen the members as required, applying two coats of epoxy zinc primer on new and old steel surfaces, saturate the substrate with water applying one coat of polymer modified bond coat on affected concrete surfaces and finally providing polymer modified cement and quartz sand mortar in CM 1:3 mix , 40mm thick in two coats, using polymer SBR Latex or equivalent as approved @ 5 Ltrs per 50 Kg bag of cement complete all as per manufacturer's Specifications/instructions and as directed. Note :-( New reinforcement (Welded wire fabric) will be measured and paid separately) Make : Dr. Fixit/Sunanda/chemestik/Fosrok
S&F welded steel wire fabric, cut to length, fixed to steel members/reinforcement steel, weigh per Sqm not exc. 4 Kg.
M&L for preparing new plastered or un-plastered surfaces and applying three coats of white wash on ceilings complete all as specified and directed.
M&L for preparing old plastered or un-plastered surfaces and applying one coat of white wash on ceilings complete all as specified and directed.
M&L Preparation of new surfaces of plastered or unplastered surfaces of wall and applying three coats of white washing.
M&L Preparation of old surfaces of plastered or unplastered surfaces of wall and applying one coat of white washing.
M&L for preparing of new plastered or un-plastered surfaces of walls and applying two coats of oil bound distemper over a coat of primer over and including wall care putty complete all as specified and directed.
M&L for complete removal of existing treatment and preparation of old plastered or un-plastered surfaces and applying two coats of oil bound distemper over a coat of primer over and including wall care putty complete all as specified and directed.
M&L for preparation of new plastered surfaces of wall and applying two coats of cement base paint over a coat of primer complete all as specified and directed.
M&L complete removal of existing treatment of wall and preparation of old plastered or Un plastered surfaces of wall and applying two coats of cement base paint complete all as specified and directed.
M&L for complete removal of existing treatment on old plastered or unplastered surfaces of wall and applying two coats of exterior paint over one coat of primer Make - Apex of Asian Paints or equivalent as approved by GE.
Taking down chowkats or frame of any description n exc 1.5 Sqm each (without taking off shutters from the frames) removing to store complete as specified and directed.
Taking down chowkats or frame of any descrip tion exc 1.5 Sqm each and n.exc 4 Sqm (without taking off shutters from the frames) removing to store complete as specified and directed.
Taking down chowkats or frame of steel windows/ ventilators n.exc 1.5 Sqm (without taking off shutters from the frames) removing to store complete as specified and directed.
Taking down shutters of any description exc 1 sqm and not exc 2 sqm each.
Re-fixing in the same opening of shutters of any description exc 1 sqm and n exc 2 sqm each.
Dismantling wrought iron or mild steel works of any description
Demolition of reinforced cement concrete of any description and in any position not otherwise specifically provided for, such as manholes cover etc complete all as specified and directed.
M&L for providing precast cement concrete type C1, 1:3:6 (20mm graded aggregate) in landings, cover slabs(for manholes etc) with plain fair faces, including chamfers, weathering, throating etc and setting in cement mortar 1:6 complete with joints to match.
S&F mild steel TMT bars 6 to 8mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified.
M&L for cement concrete 1:1.5:3 type A1 using 20mm graded stone aggregate as in fins, facia, chajja, parapet, louvers, railing complete to match with existing all as specified and directed.
M&L for preparation of new plastered or unplastered surface of wall and applying two coats of exterior paint over one coat of primer all as specified and directed
S&F, MS angle iron framed work as in doors or gates of angle or other section conforming to Fe 290(Gde E-165) with gusset plates, rails, braces, etc complete including hanging also fastening and fixing complete all as specified and directed.
S&F, 35mm thick, second class HW in glazed and skeleton shutters, open rebated and prepared to receive glass, gauze etc.(without sash bars) edges of framing plain chamfered or rounded, fitted with cut and mitred beads for securing glass, etc. size of members of shutters as specified in SSR Part-I, section 8, clause 8.24 (a) supplied and fitted to chowkats complete all as specified and directed by Eng-in-Charge.
S&F, 30mm thick flush shutter with solid core construction with block board core and plywood face panel commercial type on both faces.
S&F 35 mm thick, 2nd class hard wood factory made, plain, framed, panelled shutter (two panel) with lock rail and panel of 9 mm B.W.P commercial ply or 12 mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS: 1003 (Part I), kiln seasoned and chemically pressure treated complete all as specified and directed.
M&L for anodised aluminium frame/shutters for doors, windows ventilators with one or more rebates including joining cleat for fixing and suitable handle etc. complete all as specified.
S&F 5mm thick Sheet glass, ordinary quality with and including neoprene beadings in square nexc 0.5 sq.m in each pane
S&F 4mm thick Figured glass, pin headed type including neoprene beading in squares n exc 0.5 sq.m in each pane
S&F, stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed to wooden door Shutters/aluminium sliding shutters complete all as specified and directed.
S&F galvanised mild steel wire cloth, 0.63mm nominal dia of wire and average width of aperture 1.40mm and fixed with tinted tacks or galvanised wire staple complete all as specified and directed.
S&F MS framed work such as grills, guard bars of window and similar work with ends of bars shouldered and/ or riveted, or forged into spikes conforming to Fe 290(Gde E-165) complete all as specified and directed.
M&L for preparation of new wooden surface of any description, over 10cm width or girth and applying two coats of synthetic enamel paint over one coat of pink primer complete all as specified and directed.
M&L for preparation of new steel surface of any description exc. 10cm width or girth and applying two coats of synthetic enamel paint over one coat of red oxide primer complete all as specified and directed.
S&F Solid PVC Door frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with MS Square tube, supplying and fixing in opening as per specifications and drawings complete all as specified and directed.
S&F Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of MS tube for top and bottom rails. MS frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Paneling of plain colour PVC sheet to be fitted in the MS frame welded/ sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, supplying and fixing in the frame at site as per specification & drawing complete all as specified and directed by Eng-in-Charge.
S&F, 300mm long bolt aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy.
S&F, 150mm size, aluminium alloy handles, fabricated type, anodised complete all as specified and directed.
S&F, aluminium, anodised barrel tower bolt of extruded section and fixed 200 mm of size
S&F, 150mm long floor door stopper of aluminium alloy body and tongue with hard drawn steel springcomplete all as specified and directed.
S&F butt hinges, medium weight, cold rolled, mild steel of size 100 mm complete all as specified and directed.
S&F 100mm double action spring hinges, mild steel with steel wire spring, stove enamelled, black complete all as specified and directed.
S&F, in repairs, 25mm dia, powder coated, fancy type, aluminium decorative tubular curtain rod with decorative ball type side brackets, complete all as specified and directed.
S&F 2nd class hard wood, Plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints, supplied and fixed
S&F 18/19mm thick prelaminated particle board, interior grade, prelaminated one side with decorative choice laminations and other side balancing white lamination, fixed with screws to timber frame work in cup boards, rebated or flat edged complete all as specified and directed.
S&F, in repairs, 18/19mm thick prelaminated particle board, interior grade, prelaminated one side with decorative choice laminations and other side balancing white lamination, fixed with screws to timber frame work in cup boards, rebated or flat edged complete all as specified and directed.
M&L for 6mm thick external teak wood lipping fixed to18/19mm thick block or Veneered particle boards with nails complete all as specified and directed.
S&F continuous (piano) hinges, mild steel bright finish or electrogalvanised, width of flap 40 mm complete all as specified and directed.
S&F hasp & staples 125mm in size, safety type aluminium anodised fixed with screws.
Ball catches with 8mm dia steel ball, and brass body and striking plate including letting in and fixed.
S&F 100 mm size extruded aluminium alloy handles, fabricated type, anodised.
S&F, in repair, glass shelf, 600mm long complete all as specified and directed. Make-Jaquar Cat No ACN-1171N or equivalent as approved by GE.
S&F vitreous china squatting pan, 'Orissa’ pattern, white of size 580mm x 440mm with integral foot rest, P or S trap (excluding flushing cistern and flush pipe) complete all as specified and directed.
S&F, in repairs, vitreous china squatting pan, 'Orissa’ pattern, white of size 580mm x 440mm with integral foot rest, P or S trap (excluding flushing cistern and flush pipe) complete all as specified and directed.
S&F in repairs vitreous china wash down closet pan (pedestal pattern) of white (excluding flushing cistern and flush pipe) but incluging trap, connection to drain pipe or outgoing pipe and to flushing pipe, antisyphonage pipe, seat and cover etc complete all as specified.
S & F in repairs vitreous china wash hand basin, white, flat back of size 550x400mm with and including CI brackets, 32mm bore brass CP waste coupling Inlet/ outlet, PVC flexible pipe, 600mm size for 15 mm bore pipe with brass nut and washers etc complete.
S&F, in repairs, 10 litres capacity, PVC valveless, syphonic action type, flushing cistern, low level, white, with inlet ball valve, float and handle including brackets and connection to pipe or lever etc. complete all as specified and directed.
S&F, chromium plated over head shower 100mm dia round shape single flow (ABS Body chrome plated with Gray face plate) with rubit cleaning system complete all as specified and directed as per Cat No EOS-542N of Essco or equivalent make approved by GE.
S&F, chromium plated, Towel Rail, 600mm long complete all as specified and directed
S&F, in repairs, 15mm brass chromium plated bib cock with wall flange, complete all as specified and directed
S&F, in repairs, stop valves angular, chromium plated for iron pipe or for unions and fixed to 15mm bore pipe, complete all as specified and directed as per Cat No MQT-513A of Essco or equivalent make in Jaquar/Zoloto/Soma/Leader as approved by GE.
S&F in repair, concealed stop cock heavy body casted cap 15mm chromium plated for iron pipe or for union and fixed to 15mm bore pipe, complete all as specified and directed as per Cat No MQT-514A of Essco or equivalent make in Jaquar/Cera/Marc/Kohler as approved by GE.
S&F, in repair, 8mm dia brass chromium plated health faucet (hand shower) with 01m long flexible tube and wall hook complete all as specified and directed. Make : Jaquar Cat No ALD-573 or equivalent as approved by GE.
Supply only 15mm pillar taps, brass chromium plated fancy type with capstan heads, screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly nuts screwed for iron pipe or for union and fixed to 15mm bore pipe, complete all as specified and directed.
S&F in repairs 25mm bore dia of gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed.
S&F 40mm, low density polyethylene pipes (LDPE) of pressure rating 6 kgf/Sqcm fixed complete to walls, ceilings or in floors etc.
S&F PVC connections 15mm size with PTMT nuts of length 450mm
S&F, in repair, kitchen sink with drainage board made of stainless steel 1mm thick including supply and fixing 32mm CP waste coupling, plug, washer, 32 mm bore and 60cm long PVC waste pipe including cantilever brackets made of mild steel duly painted with two coats of synthetic enamel paint over a coat of red oxide primer, cutting for and pinning in ends of brackets to errecting stand into wall, over all size 915mm x 460mm and bowl size 410mm x 330mm x 160mm complete all as specified and directed.
S&F in repairs, 0.63mm thick, stainless steel plate rack of size 1200mmx 900mmx180mm complete all as specified and directed.
Taking up or down steel tubing and connections for 15mm bore of pipe complete all as specified and directed.
Taking up or down steel tubing and connections for 20mm bore of pipe complete all as specified and directed.
Taking up or down steel tubing and connections for 25mm bore of pipe complete all as specified and directed.
S&F steel water tubes, medium grade, galvanized, with all fittings and fixed to walls and ceilings or laid in floors for 15mm bore of pipe complete all as specified and directed.
S&F steel water tubes, medium grade, galvanized, with all fittings and fixed to walls and ceilings or laid in floors for 20mm bore of pipe complete all as specified and directed.
S&F steel water tubes, medium grade, galvanized, with all fittings and fixed to walls and ceilings or laid in floors for 25mm bore of pipe complete all as specified and directed.
Refixing old serviceable steel tubing and connections in new or old position (walls, ceilings, floors etc.) for 15mm bore of pipe complete all as specified and directed.
Refixing old serviceable steel tubing and connections in new or old position (walls, ceilings, floors etc.) for 20mm bore of pipe complete all as specified and directed.
Refixing old serviceable steel tubing and connections in new or old position (walls, ceilings, floors etc.) for 25mm bore of pipe complete all as specified and directed.
Cutting chases, pinning in, making good to facing where required and pointing in cement mortar (1:3) for concealed water tubing or concealed conduit wiring, etc and making good, cutting exceeding 20cm girth, complete all as specified and directed.
S&F rotational moulded polyethylene water storage tanks of capacity 500 Litres (Cylendrical vertical with closed top)hoisted and fixed in position all as specified in SSR-Part-I including disconnecting and removal of old U/S PVC tank.
S&F in repairs 20mm dia ball valves high pressure of PTMT with epoxy coated Aluminium rod & high-density plastic bal screwed for iron pipe and fixed. (Minimum weight 15mm-142 gms/ 20mm-210 gms/25mm-455gms/ 40mm- 690 gms) all as specified and directed
Dismantling of 100mm dia cast iron , SGSW, PVC or reinforced concrete drain pipes jointed in neat cement mortar and taking out of trenches if required.
S&F 75mm dia PVC (SWR) grade single socketed pipes in any length complete with rubber ring joints laid in trenches or in floors/ walls
S&F 110mm dia PVC (SWR) grade single socketed pipes in any length complete with rubber ring joints laid in trenches or in floors/walls
S&F PVC (SWR) bends of any radius with oval and access door of 75mm dia
S&F PVC (SWR) bends of any radius with oval and access door of 110mm dia
S&F PVC (SWR) branch piece single (single ‘Y’) equal or unequal suitable for 75mm bore pipe.
S&F PVC (SWR) branch piece single (single ‘Y’) equal or unequal suitable for 110mm bore pipe.
S&F PVC (SWR) vent cowl of 75mm dia
S&F PVC (SWR) vent cowl of 110mm dia
S&F PVC (SWR) Floor/ Nahani trap with grating of diameter of outlet 75mm including jointing to waste pipe fixed in cement concrete type B1 (1:2:4).
S&F PVC (SWR) gully trap 125/110 mm, setting and jointing with solvent cement, complete fixed all as specified.
Demolition of brick work or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars etc. complete all as specified and directed.
M&L for walling of random rubble stone masonry, uncoursed, brought upto courses, well bonded, bedded and solidly hearted, built in CM (1:6) complete all as specified and directed.
Walling of random rubble stone masonry, uncoursed, brought upto courses, well bonded, bedded and solidly hearted, built in CM (1:6) but except stone, complete all as specified and directed.
M& L for cement concrete 1:3:6 type C1 using 20mm graded stone aggregate as in coping, including necessary formwork etc complete.
M&L for rendering 15mm thick cement plaster in cement mortar 1:4 on stone Masonary surfaces or surface other than fair face of brick work is to be finished even and smooth w/o using extra cement completed as specified and directed.
Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m depth for foundation etc for manholes,septic tanks,wells etc not exceeding 10 sqm on plan and not exceeding 1.5m in depth and getting out in Hard dense soil
Returning, filling in, including, levelling, watering and well ramming in layers not exceeding 25cm thick.
Removing excavated material n.exc 50m and depositing where directed at a level n.exc 1.5 above the starting point.
Demolition and breaking up drain pipes (salt glazed stoneware, AC or reinforced concrete), set in cement mortar for 150mm bore of pipe complete all as specified and directed.
All as per item no 132 above but for 200mm bore of pipe.
M&L cement concrete 1:3:6, type C-2 (using 40mm graded stone aggregate) in bed to drain pipes including packing under and haunching against the side of pipes after they are laid and tested for 150mm internal dia of pipe.
M&L cement concrete 1:3:6, type C-2 (using 40mm graded stone aggregate) in bed to drain pipes including packing under and haunching against the side of pipes after they are laid and tested for 200mm internal dia of pipe.
M&L salt glazed stone ware (SGSW) drain pipes laid in tenches and jointed specified in size of pipe is Grade 'A' 150 mm internal dia of pipe.
M&L salt glazed stone ware (SGSW)drain pipes laid in tenches and jointed specified in size of pipe is Grade 'A' 200 mm internal dia of pipe.
Demolition of reinforced cement concrete of any description and in any position not otherwise specifically provided for complete all as specified and directed.
Demolition of cement concrete(unreinforced)in ground floors and pavings n exc 15cm thickness(below or above ground level) complete all as specified and directed.
M&L for 75mm thick cement concrete, type C2, 1:3:6 (40mm graded stone aggregate as in sub base and finished the surface rough to receive tile complete all as specified and directed.
Cuting into existing manholes for connecting new drain making good to pipes and rendering, cutting out existing benching forming branch channel 1/2 round 3/4 section in cement conrete 1:2:4 type B1 smooth finished for 200mm bore pipe.
S&F moduls furniture of PVC shutters of SPUF 128, 20mm thick colour code D-01 and frame size 48x40mm (RUPS 4141) complete all as specified and directed. Make Sintex or equivalent make as approved by GE
S&F 20mm PVC sheet SPUF 128, colour code D-01 of Sintex for purposed of wooden complete all as specified and directed. Make Sintex or equivalent make as approved by GE.
S&F stainless steel kitchen basket with stainless steel wire perforate plate fabricated and stainless steel sliding guide chanel heavy duty complete all as specified and directed.
M&L for preparation of old painted wood and wood base surfaces of any description, not otherwise described over 10 cm width or girth and painting with a coat of sythetic enamel paint.
M&L for preparation of old painted Steel and iron surfaces of any description, not otherwise described over 10 cm width or girth and painting with a coat of sythetic enamel paint.
Opening the separation cracks at the junction of RCC and Masonry wherever directed and instructed into "V" grooves 2" to 3" from the either side of the cracks by carefully marking the areas to be opened up using a cutting machine and skillfully/carefully chiseling with a well sharpened chisel and hammer as directed including wire brushing and washing of concrete substrata and masonry walls with water jet to the surfaces thus prepared to the entire satisfaction of the Engineer in Charge as instructed and directed.
Moistening the cracks, providing and applying priming/bonding coat of slurry made out of "Polyalk EP" and cement (or equivalent as specified in the list of brand name)in proporation 1:1 to surfaces prepared as instructed and directed. Filling the craks/Grooves by providing and applying "Polyyalk EP" polymer modified cement mortar (or equivalent as specified in the list of brand names) in proportion 1:5:15 (Polyalk EP:Cement:Graded sand/quartz sand)on the prepared surface and finishing it in level with the existing plaster including hand packing, curing and making the surface similar to the external plastering using wooden floats/punch etc complete as per specified and directed.
Drilling holes of required size upto 16mm diameter and up to 50mm depth in concrete and cleaning the same as directed.
Providing and fixing 12mm diameter aluminium/PVC injection nipples and securing the same as directed & providing and injecting cementitious grout using CEBEX-112 additive of Fosroc at the of 225 grams per bag of cement and using suitable mechanical gun/pump including mixing etc complete.
Providing and fixing epoxy dipped shear keys of 10mm dia and 4" to 6" length in columns before jacketing, Micro concreting as per manufacturer's instructions and directions.
M&L for providing mild steel bars 10mm dia and over cut to length bend to shape required including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips.
Providing and laying super fluid microconcrete -roffe crete repqirs (or equivalent as specified in the list of brand names) in beam bottoms, columns, slabs etc, including mixing with 5mm to 10mm size aggregates, waterproof ply wood/steel plate shuttering, pouring, temping, consolidating, curing etc complete as per manufacturer's specification and consultants Instructions. Note :- This item shall be paid on actual consumption of Micro concrete.
Taking down carefully UNSV copper/aluminium point wiring (light, fan, bell, power sockets) along with UNSV fittings/fixture such as switches, ceiling roses, pendants, regulators, sockets, electric fitting, light fittings including serviceable fitting/fixture and making good the disturbed surface (serviceable fitting/fixtures shall be measured and paid separately)
Taking down carefully old UNSV light fitting, holder of any type/any size removing material to store for keeping in safe custody or for taking credits (credit for above items should be made as per condition seperately).
Taking down carefully old UNSV DV Box of any type/any sizeincluding US MCB SPN/SP removing material to store for keeping in safe custody or for taking credits (credit for above items should be made as per condition seperately).
Taking down carefully old UNSV of earthing with galvanized iron earth plate electrode 60cm X 60cm X 60cm thick buried directly in ground vertically to a depth and including earth lead GI wire 4mm dia by means of volts and nuts, check nuts and washers etc all as specify and directed
Taking down carefully old UNSV submain wiring of any type/any size removing material to store for keeping in safe custody or for taking credits (credit for above items should be made as per condition seperately).
M & L for point wiring with PVC insulated 1100 volts grade, unsheathed, copper multi stranded conductor, 1.5 sqmm size FRLS cable drawn in and including PVC casing capping 32x12 mm complete with all accessories like bend, tee, junction box etc along with one No PVC insulated , 1100 volts grade, unsheathed copper multi stranded conductor, 1.5 sqmm size as continuous earth wire (conductor) connected to comman earth dolly using colour code and terminating in new MS suitable boxes covered with laminated sheet cover 3.00 mm thick sheet and cadmium screws, cup washers complete all as specified and directed for the following :- One light/fan point controlled by one switch with 1.5 Sq. mm nominal area cable in & including rigid PVC heavy duty concealed conduit.
one multi pin socket 5 Amps, independent
One 5 amps socket outlet on the same board controlled by another switch
One bell/ buzzer point controlled by one push button on same board with other switches or independent with cable 1.5 sqmm
One light point controlled by 2- two way switch with 1.5 Sq. mm nominal area cable in including rigid PVC heavy duty concealed conduit.
All as per item No 159 above but for 15 amps socket point on independent board using FRLS cable 2.5 sqmm.
M & L switch piano flush button single pole, one way 5 amps complete.
Supply fixing switch Piano, flush type, single pole, two ways, 5 Amp complete all as specified and as directed by the Engineer – In –Charge
M & L socket outlet 3 pin, 5 amps flush type complete.
M & L socket outlet purpose, 3 pin 15 amps and 5 Amps controlled by one switch complete.
M & L switch piano flush button single pole, one way 15 amps complete.
Supply fixing bell push, flush type, 5 Amp, 240 volt single pole complete all as specified and as directed by the Engineer – In –Charge
M & L ceiling rose, 3 pin surface, white /any shade , three terminal.
M&L in replacement in ceiling fan regulator, elect step type AC 230 volt complete all as specified and directed.
S & F lamp holder , insulated body with back plate suitable for batten fittings including LED lamp 9W complete all as specified and directed.
M & L buzzer Ding Dong AC 230 volt, single pole, complete all as specified and as directed by the Engineer – In –Charge
S & F in repair sheet metal distribution board SPN DB Double door factory made and tested complete protection class IP-43 suitable for mounting MCBs , isolator with 200 amps tinned copper bus bar capacity 8 way, 240 volts complete.
S & F in repair MCB SPN 32 -40 Amp volt 220 complete with connection as all specified and direced.
S & F in repair MCB type 'C' 10 KA, Single pole 6 to 40 amps.
S & F, in repair, 1x20W Surface and wall mounted LED batten with LED tube rod extruded aluminium housing provided for efficient heat dissipation with polycarbonate diffuser & integrated electronic driver. 4 feet long.
S & F, in repair, CFL light fittng 1x11W with CFL wall/ceiling mounted any type with metallic channel with blast lamp holder connector block, bracket, etc complete with all acces and including connection up with twin core flexible copper conductor cable with suitable size complete as all specified and directed.
S & F, in repair, CFL light fittng 1x9W with CFL wall/ceiling mounted any type with metallic channel with blast lamp holder connector block, brecket, etc complete with all acces and including connection up with twin core flexible copper conductor cable with suitable size complete as all specified and directed.
S & F Two single core PVC insulated unsheathed cable with multi stranded copper conductor of size 6 Sq.mm as submain wiring including suitable size of PVC Casing Caping including PVC insulated unsheathed copper conductor cable of size 6Sq mm as an each continuity conductor complete all as specified and as directed by Engr- In Charge .
S&F, in repairs, sheet metal enclosures, single pole & neutral with a two pin & earth plug and socket complete with one single pole, MCB of 20 Amps, 10 KA, 240 volts complete all as specified and directed
S&F two single core PVC insulated unsheathed cable with multi stranded copper conductor of size 4 Sq.mm as AC circuit wiring including suitable size of PVC Casing Caping including PVC insulated unsheathed copper conductor cable of size 4 Sq mm as an each continuity conductor complete all as specified and as directed by Engr- In Charge .
S&F, exhaust fan ,AC 230/240 Volts, 50 Hz 250 mm sweep ISI Marked complete with bladed,louvers etc including provision of making the hole in wall complete all as specified and directed.
Taking Down and refixing , exhaust fan ,AC 230/240 Volts, 50 Hz 250 mm sweep ISI Marked complete with bladed,louvers etc including provision of making the hole in wall complete all as specified and directed.
S&F, water heater storage type electric of capacity 25 Litre BEE 5 star rated including all water pipe fitting nuts bolts etc connection completed all as specified and directed.
Taking down and refixing of fans ceiling fan single phase step type regulator,AC 230/240 Volts, 50 Hz, 1200mm sweep ISI Marked complete with paint on fan and blades, louvers etc including provision of hanging on roof wall complete all as specified and directed.
Taking down of single phase electric energy and making all connections complete as all specified and directed.
S & F electric energy meter AC single phase of Accuracy Class 1, 240 V, 50 Hz with backelit LCD display of rating 10-60 Amp and with push button measure & display KWH, V, I, PF, KW, KVA, six months history of energy and MD in KW with special features like TOD, tamper logging, optical communication post & display in absene of power of Make HPL/Secure/L&T
Supply, install testing and commissioning of factory made LT panel wall mounted board made out of CRCA sheet of 2 mm thick indoor type totally enclosed weather, dust and vermin proof with front opening hinged door and locking arrangement mounted on MS flat iron clamp welded to panel body duly grouted in wall , 415 volts 3 phase , 4 wire AC 50 HZ having aluminium bus bar 25 mm x 10 mm for phase and the neutral insulated with PVC sleeves, space for fixing single phase KWH electric meter suitable capacity 08 Nos, 40 mm x 40 mm x 6 mm size angle iron bracket hold fast, fastener bolts, copper lugs, spacers, mounting channels, rubber , gasket locking knobs , hylam sheet pieces, PVC shrinkable sleeves, nuts and bolts , washers etc suitable single core copper wire connections, suitable compartments and epoxy power spray paint with primer complete all as specified including the following accessories including taking down old u/s distribution board, taking down and refixing serviceable electric KWH meter in new panel INCOMMING (a) MCCB 415 Volts 4 pole 25KA breaking capacity of 100 amps-01 No (b) R-Y-B phase, LED indicating lamp - 03 Nos (c) 20A/4 amp HRC control fuse with fuse link - 03 Nos (d) 200 amp TPN main aluminium bus bar OUTGOING (a) MCB SPN 40 Amp 10 KA = 04 Nos (b) Space for mounting single phase energy meter-04 Nos (c) copper wire 10 sqmm wire and open terminals for all feeders
Supply, install testing and commissioning of factory made LT panel wall mounted board made out of CRCA sheet of 2 mm thick indoor type totally enclosed weather, dust and vermin proof with front opening hinged door and locking arrangement mounted on MS flat iron clamp welded to panel body duly grouted in wall , 415 volts 3 phase , 4 wire AC 50 HZ having aluminium bus bar 25 mm x 10 mm for phase and the neutral insulated with PVC sleeves, space for fixing single phase KWH electric meter suitable capacity 04 Nos, 40 mm x 40 mm x 6 mm size angle iron bracket hold fast, fastener bolts, copper lugs, spacers, mounting channels, rubber , gasket locking knobs , hylam sheet pieces, PVC shrinkable sleeves, nuts and bolts , washers etc suitable single core copper wire connections, suitable compartments and epoxy power spray paint with primer complete all as specified including the following accessories including taking down old u/s distribution board, taking down and refixing serviceable electric KWH meter in new panel. INCOMMING (a) MCCB 415 Volts 4 pole 25KA breaking capacity of 100 amps-01 No (b) R-Y-B phase, LED indicating lamp - 03 Nos (c) 20A/4 amp HRC control fuse with fuse link - 03 Nos (d) 200 amp TPN main aluminium bus bar OUTGOING (a) MCB SPN 40 Amp 10 KA = 08Nos (b) Space for mounting single phase energy meter-08 Nos (c) copper wire 10 sqmm wire and open terminals for all feeders
M&L earthing complete with galvanized steel earth plate electrode of 60 cm x 60 cm x 6mm thick buried directly in ground [earth pit not less than 2.25 metre deep below normal ground level] with top edge of the plate not less than 1.5 m below normal ground level, connected to galvanized earth wire of 4mm dia by means of bolts, nuts, check nuts and washers of galvanized iron or steel all as shown in electrical plate No. 3 of MES SSR Part I all as specified and testing on completion including provision of earth lead protected by 15 mm dia light grade GI pipe & watering pipe shall be 20 mm bore medium grade GI pipe including all excavation and earth work in any type of soil, PCC pit with RCC cover, char coal, salt, funnel etc complete. Note : Rate quoted by tenderers shall be deemed to include for following provisions;-[i]. Excavation & earth work in any type of soil including removing of surplus material upto 50 M.[ii]. PCC 1:3:6 type C1 using 20mm graded stone aggregate in pit & 40mm thick precast RCC 1:2:4 type B1 cover 50x50 cm with 8mm TMT bars @ 10 cm C/C both ways with handles.[iii]. Main earthing lead from earth electrode to test point upto 7.5 mtr.[iv]. Funnel with watering pipe [GI pipe] 20mm bore [ISI marked] medium grade & copper lugs, charcoal & salt as reqd.[v]. GI protection pipe of size 15 mm bore light grade 7.5m.
Excavating in trenches not exceeding 1.5m wide and not exceeding 1.5 m in depth for foundation of pole,laying of cables etc in Hard/dense soil and getting out.
Returning filling in including spreading, leveling, watering and well ramming in layer not exc 25 cm.
Removing excavated material not exc 50 mtr and depositing where directed at a level not exc. 1.5 m above the starting point.
M&L for providing dry river sand as in sand cushioning to UG cable including punning gently all as directed. Note : Depth after punning shall be measured and paid.
M&L for plain cement concrete 1:2:4 type B-1 using 20mm graded stone aggregate for padestal/coping around poles/ repair of cutting roads, including necessary form work, finishing even and smooth without using extra cement, all as specified and directed.
Supply and laying sub class old 'B' burnt bricks, size of brick 230x115x75mm, laid as cable protection cover complete all as specified and directed.
S&F, in repair, GI pipe, 40mm bore, light grade, laid below road/fixed along the poles / walls with necessary clamping, etc complete all as specified and directed.
Taking down carefully all unsv cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cable (heavy duty) 1100 volts grade with stranded aluminium conductor of size 16/25/35/50 sqmm, 3.4/4 core
Supply and lay cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cable (heavy duty) 1100 volts grade with stranded aluminium conductor of size 35 sqmm, 3.5 core
Supply and lay cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cable (heavy duty) 1100 volts grade with stranded aluminium conductor of size 25 sqmm, 4 core
Taking Down US Pipe galvanized, medium grade, 20 mm dia laid below road/fixed along wall, clamping etc. complete as all specified and directed.
Taking Down US Pipe galvanized, medium grade, 25 mm dia laid below road/fixed along wall, clamping etc. complete as all specified and directed.
Taking Down US Pipe galvanized, medium grade, 40 mm dia laid below road/fixed along wall, clamping ect. complete as all specified and directed.
Taking Down US Gate valve, 20/25/40 mm dia . complete as all specified and directed.
supply and lay/fixed Pipe galvanized, medium grade, 20 mm dia laid below road/fixed clamping ect. complete as all specified and directed.
supply and lay/fixed Pipe galvanized, medium grade, 25 mm dia laid below road/fixed along wall, clamping ect. complete as all specified and directed.
supply and lay/fixed Pipe galvanized, medium grade, 40 mm dia laid below road/fixed clamping ect. complete as all specified and directed.
Cutting of exsiting pipe of 100/80 mm dia forcutting , weldingand making branch connection complete all as specified and directed.
Supply & fixed gun metal globe or gate valves of dia 20 mm with iron wheel head, screwed both end for pipe complete as all specified and directed.
Supply & fixed gun metal globe or gate valves of dia 40 mm with iron wheel head, screwed both end for pipe complete as all specified and directed.
M & L of demolition of existing valve pit and M&L for construction of valve pit consisisting of 230mm thick, old size brick masonry wall in cement mortar (1:6), PCC (1:4:8) type D2, using 40mm graded stone aggregete as in foundation, PCC (1:2:4) type B1, using 20mm graded stone aggregete in coping/bed, finished even and smooth, rendering 15mm thick in cement mortar (1:6) internally and 10mm thick in cement mortar (1:4) externally, finished even and smooth without using extra cement incuding three coats of white wash and earth work in any type of soil and including 3mm thick MS sheet cover fixed on 40mmx40mmx6mm thick angle iron frame embeded in PCC coping with locking arrangement and mild steel hold fast & handle and duly painted with two coats of synthetic enamel paint over one coat of primer etc. complete all as shown on drawing NO TD/2004/26 Sh 1/1 to 1/3 and as specified and directed for the following sizes:- 900mm x 600mm x 1000mm
S&F, in repair, mild steel framed brackets of angles or tees with web and flanges cut to shape, drilled and counter sunk for screw, including bending and welding angles as necessary, gusset plates, riveting, etc confirming to Fe-290 Gde-E-165 complete all as specified and directed.
S&F, in repair, mild steel sheets/plates of Fe-410-W (Gde-E-250) quality - A (plain or chequered), forming holes/welded to frame work, as in valve pit cover complete all as specified and directed.
Excavating in trenches not exceeding 1.5m wide and not exceeding 1.5 m in depth for foundation of pole,laying of cables etc in Hard/dense soil and getting out.
Returning filling in including spreading, leveling, watering and well ramming in layer not exc 25 cm.
Removing excavated material not exc 50 mtr and depositing where directed at a level not exc. 1.5 m above the starting point.
VIJAY CONSTRUCTION CO
M K ENGINEERS CO.
Suraj Infraprojects
shree ram laxman sthaptya co
Micro Protect
M/s Matadeen Ramchandra Agarwal
vijay infraprojects pvt ltd
Saroj Construction Company
stage.html
html • 0.08 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .