Loading…
Loading…
Tender Value
₹10 L
EMD Value
₹30,000
Closing Date
18 Sept 2026, 4:00 pm
SE
400KV Ope. and Maint. Circle, Rishikesh
PROVIDING and INSTALLATION SPLIT TYPE A.C FOR CONTROL ROOM AT SUBSTATION, RISHIKESH
2026_PTCUX_99119_1
T-13/SE(OandM)R/2026-27
Open Tender
Electrical Works
Item Wise
90 days
Rishikesh
Please refer Tender documents.
3 documents required · 3 mandatory
₹590
Yes
EE, 400KV OandM Division
₹30,000
Yes
19 Aug 2026
19 Aug 2026
19 Sept 2026
20 Aug 2026
18 Sept 2026
20 Aug 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Providing of Air Conditioner 2 Ton 3 Star rated Split Type 220-240 Volt. Of ISI/BSI mark reputed make company as like Hittachi/Daikin/ Carrier/ Bluestar etc. | 8 | No | - | - |
| 2 | Power plug wiring in PVC conduit (2X4 sqmm), wiring for light/power plug with 2X4 sqmm. FR PVC insulated copper conductor single core cable in surface/recessed PVC conduit alongwith 1 no 4 sqmm. FR PVC insulated copper conductor single core for loop earthing as required. | 60 | Metre | - | - |
| 3 | Supply and fixing modular type switch with modular plate & switch box including connections but excluding modular plate etc. as required 15/16 amps switch | 8 | each | - | - |
| 4 | Supply and fixing modular type socket with modular plate & switch box including connections but excluding modular plate etc. as required (6 pin each 15/16 amps socket outlet) | 8 | each | - | - |
| 5 | Supplying and fixing 4 way (4+12) horizontal type three pole and
neutral, sheet steel, MCB distribution board, 415 V, on surface/recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/ Isolator) | 1 | each | - | - |
| 6 | Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in existing MCB DB complete connections, testing and commissioning etc. as required single pole. | 8 | each | - | - |
| 7 | Supplying and fixing 63 amp rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. | 1 | each | - | - |
| 8 | Providing & fixing Stabilizer coper winding with Automation for Spilit A.C2 Ton 240 volt 50 Hz A.C supply.Make:- V-Guard, blue star, Micromax. | 8 | No | - | - |
| 9 | Supply of copper pipe with copper pipe installation. | 80 | R.Ft. | - | - |
| 10 | Installation, Testing & Commissioning of 2 Ton 3 Star rated Split Type A.C. (Indoor & Outdoor unit) and refrigerant with copper piping for each unit as per the specs including drain piping & cabling work including MS stand complete with vibration pad for all Outdoor units. | 8 | Nos | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.63 MB
Tenderdoc13.pdf
Tender Documents • 1.29 MB
BOQ_116900.xls
BOQ • 0.28 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at [email protected].