EXECUTIVE ENGINEER(E)
ROOM NO.204, 2ND FLOOR CTO BLDG., CTO COMPOUND, CIVIL LINES, NAGPUR 440 001
Operation and Comprehensive Maintenance of EMS at TE and Coaxial Bldg. at Yavatmal Dist.Yavatmal , CMC of EA Sets and CMC of AC units under Yavatmal SSA
2020_BSNL_570472_1
11/CEE/BSNL/NGP/2020-21
Open Tender
Miscellaneous Services
Item Rate
730 days
TE YAVATMAL
Please refer Tender documents.
16 documents required · 16 mandatory
₹590
AO CASH GMT BSNL NAGPUR
₹57,530
10 Aug 2020
10 Jul 2020
10 Aug 2020
13 Jul 2020
7 Aug 2020
13 Jul 2020
13 Jul 2020 - 7 Aug 2020
Amount
SH-I : Operation & Comprehensive Maintenance Of EMS at TE and Co-axial Bldg. at Yavatmal (Dist:Yavatmal)
1) Operation & comprehensive Maintenance of the following Electro- mechanical services as per specifications and details of services etc. attached. a) E.I. & Fans b) Pumps c) Compound-Lighting d) Lightning conductor e) Sub-station f) E.A. Set g) Fire detection and Alarm, Fire Extinguishers, Fire Fighting. h) Split A/C unit, Window A/c Units, Water Coolers and Voltage Stabilizers i) Package AC Plant j) Geysers, Room heaters and Desert Coolers k) AVR - not applicable l) Lifts - not applicable m) Battery and Power Plant ( operation only) NOTE : 1)The Agency shall maintain the defect free services & shall submit report while raising the due payments . (a) 1st Year = =>
(b) Second Year = =>
Servicing & Routine maintenance (B check) of 1x320 KVA capacity of DG set complete with cleaning of Air cleaner element, Replacement of engine lube oil of proper grade (seal pack of reputed make), replacement of lube oil filter elements, replacement of fuel filter elements, Check & reset injector pressure, Check & reset injector pump timing, Retighten cylinder head nuts, Adjust engine valve clearance, Replacement of radiator water by fresh distilled water with addition of coolant additive concentrate, Cleaning of radiator fins, drain sediments from water separator, check inlet air restriction, check air piping, belt tensions i/c cleaning & dedusting of alternator, control panel, fuel tank, tightening & maintaining of all hose connections, electrical connections, battery connections etc & actual load testing of DG set after servicing etc as directed. ["B" check once in 12 months. Servicing should be done from authorised dealer only]
Servicing & Routine maintenance (B check) of 1x250 KVA capacity of DG set complete with cleaning of Air cleaner element, Replacement of engine lube oil of proper grade (seal pack of reputed make), replacement of lube oil filter elements, replacement of fuel filter elements, Check & reset injector pressure, Check & reset injector pump timing, Retighten cylinder head nuts, Adjust engine valve clearance, Replacement of radiator water by fresh distilled water with addition of coolant additive concentrate, Cleaning of radiator fins, drain sediments from water separator, check inlet air restriction, check air piping, belt tensions i/c cleaning & dedusting of alternator, control panel, fuel tank, tightening & maintaining of all hose connections, electrical connections, battery connections etc & actual load testing of DG set after servicing etc as directed. ["B" check once in 12 months. Servicing should be done from authorised dealer only]
Supplying & fixing of fully charged 12 volt,180AH lead acid Maintenance Free battery for starting of 320/250 KVA DG set complete with end sockets etc.as reqd. NOTE :- 1) The battery(s) of each DG set shall be replaced once during currency of contract & agency shall consider rebate for old battery while quoting of rates.
Supplying & fixing Fine Filters having efficiency of 95% efficiency down to 10 microns (EU-4 class) suitable for 7TR Package AC units . NOTE-The Filters of each PKG unit shall be replaced at once during currency of contract.
SH-II : Comprehensive Maintenance Contract of E/A sets under SSA YAVATMAL
Comprehensive Maintenance of EA sets of following ratings as per the terms and conditions enclosed. {A} E/A sets completed life less than 5 Years from date of commissioning. i) More than 45 KVA to 75 KVA EA (a) 1st Year
(b) 2nd Year
Comprehensive Maintenance of EA sets of following ratings as per the terms and conditions enclosed. {B} E/A sets completed life more than 5 Years from date of commissioning. i) More than 20 KVA to 45 KVA EA a) 1st Year
b) 2nd Year
ii) More than 45 KVA to 75 KVA a) 1st Year
b) 2nd Year
Note: For Item no. SH-II/1 [A](i) to (ii) The Agency shall maintain the defect free services & shall submit report while raising the due payments .
Servicing & Routine maintenance (B check) of following capacity of EA set complete with cleaning of Air Filter element, replacement of engine lube oil of proper grade (seal pack of reputed make), replacement of lube oil filter elements, replacement of fuel filter elements, if required replacement of radiator coolant with distilled water & addition of coolant additive concentrate, Checking & reset injector pressure, injector pump timing, tightening of cylinder head studs/nuts, adjustment of engine valve clearance, Cleaning of radiator fins, drain sediments from water separator, check inlet air restriction, air piping, belt tensions i/c cleaning & de-dusting of alternator, control panel, fuel tank, tightening & maintaining of all hose connections, electrical connections, battery connections etc. Actual load testing of EA set after servicing as directed. ["B" check once in 12 months. ] i) More than 20 kVA to 45 kVA EA
ii) More than 45 kVA to 75 kVA EA
Supplying & fixing of fully charged 12 volt lead acid Maintenance Free battery of following rating for starting of EA set complete with end lugs etc. NOTE:- Battery replacement once during currency of contract after considering rebate for old battery for quoting rate. i)130 AH
SH-III : Comprehensive Maintenance Contract of AC Units under SSA YAVATMAL
1. Comprehensive Maintenance of Window / Split / High Sensible & Package AC units of following capacity as per the terms and conditions enclosed. (A) AC units completed life less than 5 Years from the date of commissioning. i) Split AC ( 1.5TR ) a) 1st Year
b) 2nd Year
(B) AC units completed life more than 5 Years from the date of commissioning I) Window AC (1.5 TR) a) 1st Year
b) 2nd Year
ii) Split AC ( 1.5 TR) a) 1st Year
b) 2nd Year
iii) Split AC (2.00 TR) a) 1st Year
b) 2nd Year Note: For Item no. SH-III/1[A](i) , [B] (i) to (ii) The Agency shall maintain the defect free services & shall submit report while raising
Comprehensive Maintenance of AC Timer/ Twin AC stabiliser /Controller for Window / Split AC units as per the terms and conditions enclosed. (Note:- Applicable for Inverter type Split AC units in OCM and CMC work) a) 1st Year
b) 2nd Year
RELIABLE ENTERPRISES
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .