Superintending Engineer
Superintending Engineer Thiruvananthapuram Corporation 695033
Construction of a New Multistoried Building Attached to PSNM School Perrorkada Providing Electrification, LAN Connection, PA Systems, Water Purifier and Shifting the Existing CCTV Main Monitoring System
2024_LSGD_662796_1
DB/62983/2023-24(176)
Open Tender
Electrical Works
Item Rate
90 days
Thiruvananthapuram Corporation
Please refer Tender documents.
6 documents required · 6 mandatory
₹2,500
Yes
₹30,300
Yes
16 May 2024
23 Feb 2024
1 Mar 2024
23 Feb 2024
28 Feb 2024
23 Feb 2024
Amount
1.10.1 : Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductorsingle core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required. Group A
1.10.2 : Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductorsingle core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required. Group B
1.10.3 : Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductorsingle core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required. Group C
1.11 : Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor singlecore cable etc as required.
90.3.20 : Supply & installation of light fittings on TW round block Supply, conveyance installation testing and commissioning the light fittings of following types made of CRCA with 0.5mm thickness complete with all accessories and lamps etc. directly on wall or ceiling with PVC round block neatly painted to suit the fitting and giving connection with required length of 16/0.20mm 3 core copper conductor flex wire conforming to relevant ISS and giving connections as required. 90.3.20.3 1200 mm 1X20W LED Lamp with box type fixture
od1753362/2022_2023 : Supply, Installation, testing and commissioning of ceiling fan of following sizes including wiring the down rods of standard length (up to 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required. 1200mm sweep - ceiling fan complete with service value minimum 4.0(cub meter/minute/Watt), Air delivery minimum 210(cubic meter/minute), Copper winding suitable for 230V/240V single phase AC supply. (5 star).
1.58 : Supplying and fixing PVC batten/ angle holder including connection etc. As required.
1.33 : Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required.
od1753358/2022_2023 : Supply and providing the following types and power rated lamps in the existing fittings as required B22 LED bulb 10 W.
1.25 : Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
90.4.1 : Supply and installation of suitable size MS rodtype fan clamp in the RCC slab as per IS 732 as required.
1.47 : Supplying and fixing extra down rod of 10 cm length G.I. pipe, 15 mm dia, heavy gauge including painting etc. as required. (Note: More than 5 cm length shall be rounded to the nearest 10 cm and 5 cm or less shall be ignored)
Od67349/2022-2023 : supply conveyance installation testing and commissioning of exhaust fan of sizes up to 450mm in the existing opening fixing necessary anchor connection with the supplied wire along with the exhaust 300/305mm sweep light duty exhaust fan in the metal frame working on 230v A/C supply.
90.4.8 Charges for cutting holes suitable for accommodating exhaust fans up to 305mm sweep including plastering colour washing etc. as required
90.4.10 Conveyance, installation , testing and commissioning of exhaust fans of size up to 450mm in the existing opening, fixing necessary anchor bolts / bolt and nuts etc., as required including giving connections with the supplied wire along with the exhaust fan.
1.31 : Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. (For light plugs to be used in non residential buildings).
1.56 : Supplying and fixing suitable size Gl box with modular plate and cover in front on surface or in recess, including providing and fixing 2 Nos. 3 pin 5/6 A modular socket outlets and 2 Nos. 5/6 A modular switches, connection etc. as required.(For light plugs to be used in non residential buildings).
1.27.1 : Supplying and fixing following size/modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required. A) 1 or 2 Module (75mmX75mm)
B) 1.27.2 : 3 Module (100mmX75mm)
C) 1.27.5 : 8 Module(125mmX125mm)
1.24.1 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 5/6 amps switch
B) 1.24.4 : 5/6 amps socket
C) 1.24.3 : 15/16 amps switch
D) 1.24.5 : 15/16 socket outlet
90.15.4.2 : Supply Conveyance, installation, testing and commissioning of 36/40W LED street light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing,acrylic cover complete with THD less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer)
90.3.18 Supply, fabrication, conveyance and fixing the following sizes of B class GI pipe bent to shape / cut and welded to shape and fixing the same to wall /parapet using clamps as noted along with each size, painting with 2 coats of synthetic enamel paint over acoat of zinc chromate primer, making good the damages, colour washing etc as required. 90.3.18.2 32 mm dia with HG company fabricatedclamps
od1753357/2022_23 Supply and fixing cast aluminium bulk head fittings with mesh guard with 7w led bulb and giving connection etc as required.
1.14.1 : Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required. A) 1.14.1 : 2x1.5 sq.mm + 1x1.5 sq.mm earth wire
B) 1.14.2 : 2X 2.5 sq. mm + 1 X 2.5 sq. mm earth Wire.
C) 1.14.3 : 2X 4 sq. mm + 1 X 4 sq. mm earth Wire.
D) 1.14.9 : 4X 6 sq. mm + 2 X 6 sq. mm earth Wire.
90.6.4 : Supply and drawing 650/1100 V grade FRLS PVC insulated stranded single core copper conductor cables conforming to IS 694 part I 1990 in the existing surface / recess conduit as required including giving necessary connections of the following sizes. 90.6.4.51 10.00 sq.mm 1 Run
90.11.1 Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required 90.11.1.11 6 way (8+18) - three phase double cover (IP 42/43)
2.3.4 : Supplying and fixing following way,single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. 16 way double door.door.
2.3.1 : Supplying and fixing following way,single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. 6 way double door.
2.10.1 : Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole
2.13.2 : Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63 amps
2.15.3 : Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63 amps
2.12.1 : Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40 amps
2.11 : Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.
od43068 /2022-23 : supply and fixing 63 amps 415 v AC 23 A TPN SDF with HRC fuse link in SS enclosure with front handle on wall or on existing angle iron frame work. Giving connections etc as required.
Od43067/ 2022-23 : DO.. DO.. 63 amps HRC fuse with HRC fuse link with connection in the existing meter board.
Od43066 /2022-23 : Do...do...63 AMPS 415 V 2 way neutral link mounted on DMC-SMC base in the existing meter board and giving connection.
90.14.1.2 : Fabrication,supply, conveyance, installation testing and commissioning of floor or wall mounting, dust and vermin proof, cubicle type MV panel board comprising of the following components/ devices & complying to IS 8623. Fabrication of fully partitioned, dust and vermin proof enclosure for panel assembly as per form 4 of IS 8623 (with latest amendments) using CRCA sheet as per approved design and requirement, with front and rear access facility, bus bar chambers, hinged doors for all switch gear compartments, earthing the doors using 4 sq mm braided copper conductor, providing necessary cut-outs for mounting meters, relays, indication lamps, bus bar interconnection etc, detachable covers for bus bar chamber and cable alley, powder coating the assembly after subjecting to 7 tank process etc asrequired. CRCA sheet alone be used for the fabrication. Angles/flats/ slotted angles etc shall not be used for the fabrication of panel assembly. The measurements will be taken the area of the complete sheets used for panel board including partitions, folding, shrouding etc. Supply and fabrication of MV panel board using 1.6mm CRCA sheet, powder coated (excluding base frame).
5.3 : Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. (but without charcoal/ coke and salt ) as required.
90.16.1.3 : Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection metre as required. 3.15 mm copper conductor ( 10 SWG)
90.16.1.2 : Do...do...2.65 mm (no 12)
90.16.5.3 : Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required. 3.15 mm (10 SWG)
90.16.5.2 : Do..do.. 2.65mm (no 12)
Od54401/2022-2023 : supply and providing brass bolt and nut 25 X 3mm.
1.21.2: Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required. 25 mm
90.12.1 Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in ground including excavation of trench of size 35 x 75 cm, refilling the trench etc. as required but excluding sand cushioning and protective covering (in ordinary soil). 90.12.1.40 4 core 10 sq mm
9.1.32 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 4 X 10 sq. mm (25mm)
SD Rate : Supply, Testing and commissioning, splicing laying and designing with enough patch cord in patch boxes of 6 Fiber Indoor/Outdoor Single Mode Fiber Optic Cable with excellent water proof layer and moisture resistant through existing Conduit . Approved Make: Actassi, Belden, Comscope, Molex
CCTV Systems Shifting SD Rate : Excavation of trench of size 40x100cm,sand cushioning up to a height of 25 cm (80+170mm),providing protective covering with country burnt bricks laid breadth wise, refilling the trench etc. as required(in hard soil)
SD Rate : Supply and Laying of 1 inch HDPE pipe Manufactured from virgin pipe grade raw materials (PE100), Excellent corrosion and chemical resistance, High flow characteristics, Light in Weight, Excellent flexibility combined with strength, Smooth inner walls minimises frictional losses, Safe for potable water supply, Manufactured as per IS-4984, ISO-4427, DIN8074, ASTM D 3035 and BS-6437 standards in PE-63, PE-80 and PE-100 grades.
MR : Supply and fixing 19'', 4 U, Network Rack with ACDB ≥4 ports, cable manager, cooling fan etc. Approved Make: D-Link, HCL, Netrack, President, Valrack
SD Rate : Supply and installation of Gigabit Single mode OFC media convertor. Approved Make: Allied Telesis, Brocade, Cisco, Dlink,Syrotech
1.21.1 : Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required. 20 mm
LAN Connection Supplying and drawn of UTP 4 pair CAT 6 LAN cable in the existing surface/recessed steel/PVC conduit asrequired. A) 1.53.1 : 1 run of Cable
B) 1.53.2 : 2 run of cable
1.21.1 : Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required. 20 mm
B) 1.21.2 : Do..do.. 25mm
SD Rate : Do..do.. Wireless access point Netgear WAC510
SD Rate : Do..do.. 8 port POE Network gigaswitch with dlink.
SD Rate: Do..do.. CAT 6 1m patch code.
Water Purifier MR : Supply installation testing and commissioning of KENT Max UV Water purifier. (11013/UV+UF Water Purification / Wall mountable / Transparent Ditachable storage tank / 7L Storage / 60 L per\h output / White.
Ajayakumar.D
DIVIN SAM D S
ANAND R L
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_1027642.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .