Loading…
New: tenders and results on WhatsApp
New: Find tenders, results and companies on WhatsApp, by text or voice note
Loading…
Tender ID
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
Tender Value
₹23.5 Cr
EMD Value
₹23.5 L
Closing Date
16 Nov 2026, 11:00 am2d left
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
NBCC Bhawan
NBCC Bhawan
Construction of Two Section Building and Development of other facilities as per KVS norms at Khajuri Khas, New Delhi.
NBCC/SBGDelhiII/KhajuriKhas/2026/118dated30102026~EW4f36692e0d1faa5f9274ed15
NBCC/SBGDelhiII/KhajuriKhas/2026/118dated30102026
Open Tender-Domestic
Civil Works General
NBCC Bhawan
₹11,800
₹23.5 L
30 Oct 2026
30 Oct 2026
16 Nov 2026
30 Oct 2026
16 Nov 2026
Abstract of Cost - Civil/Plumbing/Fire & Electrical/LV Works
Location:- Khajuri Khas, Delhi
S.No. Description DSR Amount NDSR Amount Total Amount
S.No. Description DSR Amount NDSR Amount Total Amount
1 Internal & External Civil Works 175936765.89 4390248.00 180327013.89
2 Internal Plumbing Works 3,748,827.71 3481581.30 7230409.01
3 External Plumbing Works 5301142.18 1614190.20 6915332.38
4 Fire Fightimng Works 2175318.60 1318051.00 3493369.60
5 Internal Electrical & LV Works 11095354.52 4847047.00 15942401.52
6 External Electrical Works 4619033.09 14290332.55 18909365.64
Sub Total (DSR + NDSR) ₹ 232,817,892.04
Cost Index @ 1% on DSR Amount ₹ 202,876,441.99 ₹ 2,028,764.42
Digitally signed by ARTI
Project Name:- Construction of Kendriya Vidhyalaya at Khajuri Khas, Delhi
COST SUMMARY - CIVIL WORKS
ESTIMATE BASIS - DSR 2023 (CIVIL WORKS) & DSR 2025 (H & L WORKS)
S. No. Sub-Head
1 Earthwork 6,591,039.54 -
2 Anti-Termite Treatment 801,645.35 -
3 Concrete Works - Upto Plinth 41,016,765.80 -
4 Concrete Works - Superstructure 50,081,663.40 -
5 Masonary Work 15,332,949.60 -
8 Steel Works 6,372,060.15 -
9 Finishing 19,928,167.23 -
12 Structural Glazing & Façade Works 1,480,044.05 396,796.00
13 Dismantling and Demolishing 60,833.30 -
14 Rain Water Harvesting 718,194.75 -
Modified Estimated Cost after using Correction factor
on DSR 2023 on account of GST @0.973
15 Horticulture Work 1,001,704.40 -
TOTAL (DSR + NDSR): 180,327,013.89
Project Name:- Construction of Kendriya Vidhyalaya at Khajuri Khas, Delhi
The BOQ item description shall be read in conjuntion with the technical specifications, GCC, SCC and their quoted rates shall deem to include all works/ requirements specified
in the technical specifications, GCC, SCC etc.
DSR Item Ref. S. No. Description of Items Unit Quantity Rate (INR)
1.0 Earthwork:
Felling trees of the girth (measured at a height of 1 m above ground level) including cutting
2.33 1.1 of trunks and branches removing the roots and stacking of serviceable material and disposal -
of unserviceable material.
2.33.1 a) Beyond 30 cm girth uoto and including 60 cm girth. Each 7 532.25 3,725.75
2.33.2 b) Beyond 60 cm girth upto and including 120 cm girth Each 5 2,373.50 11,867.50
2.33.3 c) Beyond 120 cm girth upto and including 240 cm girth Each 1 11,020.15 11,020.15
Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over
areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting
out and disposal of excavated earth lead upto 50 m and for all lift, as directed by Engineer-in-
charge - In all kinds of soil
Close timbering over areas including strutting, shoring and packing cavities (wherever
required) etc. complete. (Measurements to be taken of the face area timbered):
2.18.1 a) Depth not exceeding 1.5m Sqm 1,050 125.80 132,090.00
2.18.2 b) Depth exceeding 1.5m but not exceeding 3m Sqm 1,050 144.10 151,305.00
2.18.3 c) Depth exceeding 3m but not exceeding 4.5m Sqm 1,027 163.15 167,555.05
DSR Based d) Depth exceeding 4.5m but not exceeding 6m Sqm 397 181.75 72,155.39
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations
2.25 1.4 etc. in layers not exceeding 20cm in depth consolidating each deposited layer by ramming Cum 9,129 196.00 1,789,284.00
and watering, lead upto 50m for all lift.
Supplying and filling in plinth with sand under floors, including, watering, ramming
consolidating and dressing complete
Banking excavated earth by mechanical/ manual means in layers not exceeding 20cum in
depth, breaking clods, watering, rolling, each layer with 1/2 tonne roller, or wooden or steel
2.3.1 1.6 rammers, and rolling every 3rd and top-most layer with power roller of minimum 8 tonne Cum 1,638 197.90 324,160.20
and dressing up, in embankment for roads, floor banks, marginal banks and guide banks
etc., lead upto 50m and for all lift - in All kinds of soil.
Total Carried Over to Summary: - 6,591,039.54 -
3.0 Anti-Termite Treatment: -
Supplying chemical emulsion in sealed containers including delivery as specified.
Chlorpyriphos/ Lindane emulsifiable concentrate of 20%. Digitally signed by ARTI
DSR Item Ref. S. No. Description of Items Unit Quantity Rate (INR)
Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment
(excluding the cost of chemical emulsion) :
Along the external wall below concrete or masonry apron using chemical emulsion @ 2.25
2.35.2.1 a) litres per linear metre including drilling and plugging holes etc.: With Chlorpyriphos/ Metre 445 53.45 23,785.25
Lindane E.C. 20% with 1% concentration
Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300
2.35.3.1 b) mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 Sqm 1,732 310.05 537,006.60
cement : 2 Coarse sand) to match the existing floor: With Chlorpyriphos/Lindane E.C. 20%
with 1% concentration
Total Carried Over to Summary: - 801,645.35 -
4.0 Concrete Works - Upto Plinth: -
Providing and laying in position cement concrete of specified grade excluding the cost of
centering and shuttering - All work up to plinth level:
1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone
aggregate 40 mm nominal size derived from natural sources)
Providing and laying in position ready mixed or site batched design mix cement concrete for
reinforced cement concrete work; using coarse aggregate and fine aggregate derived from
natural sources, Portland Pozzolana/ Ordinary Portland/ Portland Slag cement, admixtures
in recommended proportions as per IS: 9103 to accelerate/ retard setting of concrete, to
improve durability and workability without impairing strength; including pumping of
concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering,
shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the
following grades of concrete.
Note: Extra cement up to 10% of the minimum specified cement content in design mix shall
be payable separately. In case the cement content in design mix is more than 110% of the
specified minimum cement content, the contractor shall have discretion to either re-design -
the mix or bear the cost of extra cement.
5.33.1 a) All works upto plinth level. -
5.33.1.1 i) Concrete of M25 grade with minimum cement content of 330 kg/ cum. Cum 635 9,504.75 6,035,516.25
5.33.1.2 ii) Concrete of M30 grade with minimum cement content of 350 kg/ cum. Cum 1,107 9,655.70 10,688,859.90
Add for using extra cement or recovery for less cement consumed in the items of Design
Mix over and above the specified cement content therein.
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in
position and binding all complete up to plinth level.
5.22.6 a) Thermo-Mechanically Treated bars of grade Fe-500 D or more. Kg. 165,468 107.85 17,845,723.80
5.9 4.5 Centering and shuttering including strutting propping etc and removal of form for: - -
5.9.1 a) Foundations, footings, bases of columns etc for mass concrete Sqm 1,105 392.15 433,325.75
5.9.2 b) Walls (any thickness) including attached pilasters, buttresses, plinth and string courses etc. Sqm 253 842.50 213,152.50
5.9.3 c) Suspended floors, roofs, landings, balconies and access platform Sqm 73 927.25 67,689.25
5.9.5 d) Lintels, beams plinth beams, girders, bressumers and cantilevers Sqm 2,755 736.40Digitally
DSR Item Ref. S. No. Description of Items Unit Quantity Rate (INR)
5.9.6 e) Columns, pillars, piers, abutments, posts and struts Sqm 1,097 961.30 1,054,546.10
5.9.7 f) Stairs, (excluding landings) except spiral staircases Sqm 5 764.95 3,824.75
Total Carried Over to Summary: - 41,016,765.80 -
5.0 Concrete Works - Superstructure: -
Providing and laying in position ready mixed or site batched design mix cement concrete for
reinforced cement concrete work; using coarse aggregate and fine aggregate derived from
natural sources, Portland Pozzolana/ Ordinary Portland/ Portland Slag cement, admixtures
in recommended proportions as per IS: 9103 to accelerate/ retard setting of concrete, to
improve durability and workability without impairing strength; including pumping of
concrete to site of laying, curing, carriage for all floor to floor heights and all leads; but
excluding the cost of centering, shuttering, finishing and reinforcement as per direction of
the engineer-in-charge; for the following grades of concrete.
Note: Extra cement up to 10% of the minimum specified cement content in design mix shall
be payable separately. In case the cement content in design mix is more than 110% of the
specified minimum cement content, the contractor shall have discretion to either re-design
the mix or bear the cost of extra cement.
5.33.2 a) All works above plinth level upto floor V level -
5.33.2.1 i) Concrete of M25 grade with minimum cement content of 330 kg /cum. Cum 1,490 9,860.40 14,691,996.00
5.33.2.2 ii) Concrete of M30 grade with minimum cement content of 350 kg/cum. Cum 261 10,011.35 2,612,962.35
Extra for R.C.C./ B.M.C/ R.M.C. work above floor V level for each four floors or part thereof.
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in
position and binding all complete above plinth level.
5.22A.6 a) Thermo-Mechanically Treated bars of grade Fe-500 D or more. Kg. 193,813 107.85 20,902,732.05
Centering and shuttering including strutting propping etc and removal of form for upto
3.6m floor to floor heights for:
5.9.3 a) Suspended floors, shelves, roofs, landings, balconies and access platform Sqm 6,507 927.25 6,033,615.75
5.9.5 b) Lintels, beams plinth beams, girders, bressumers and cantilevers Sqm 3,431 736.40 2,526,588.40
5.9.6 c) Columns, pillars, piers, abutments, posts and struts Sqm 3,166 961.30 3,043,475.80
5.9.7 d) Stairs, (excluding landings) except spiral staircases Sqm 232 764.95 177,468.40
Total Carried Over to Summary: - 50,081,663.40 -
6.0 Masonry Work -
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in
foundation and plinth in:
6.1.1 a) Cement mortar 1:4 (1 cement : 4 coarse sand). Cum 26 7,370.65 191,636.90 -
Digitally signed by ARTI
DSR Item Ref. S. No. Description of Items Unit Quantity Rate (INR)
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5
above plinth level up to floor V level in all shapes and sizes in:
6.4.1 a) Cement mortar 1:4 (1 cement : 4 coarse sand). Cum 498 9,344.35 4,653,486.30 -
Extra for brick work/ AAC block masonry/ Tile brick masonry in superstructure above floor V
level, for each four floors or part thereof by mechanical means.
Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation
7.5 in superstructure above plinth level up to floor V level.
6.13.2 a) Cement mortar 1:4 (1 cement :4 coarse sand) Sqm 564 1,123.80 633,823.20 -
Extra for brick work/ AAC block masonry/ Tile brick masonry in superstructure above floor V
level, for each four floors or part thereof by mechanical means.
Extra for providing and placing in position 2 Nos 6 mm dia. M.S. bars at every third course of
half brick masonry.
Brick work with clay flyash F.P.S. (non modular) bricks of class designation 7.5 in
superstructure above plinth level up to floor five level in:
6.32.1 a) Cement mortar 1:4 (1 cement : 4 coarse sand). Cum 1,037 9,333.45 9,678,787.65 -
Half brick masonry with non modular flyash bricks of class designation 10, confirming to IS:
12894, in superstructure above plinth level up to floor V level.
6.45.2 a) Cement mortar 1:4 (1 cement :4 coarse sand) Sqm 70 1,105.80 77,406.00 -
Total Carried Over to Summary: - 15,332,949.60 -
7.0 Flooring: -
Providing and fixing 10mm thick acid and/ or alkali resistant tiles of approved make and
11.21 7.1 colour using acid and/ or alkali resisting mortar bedding, and joints filled with acid and/ or -
alkali resisting cement as per IS: 4457, complete as per the directions of Engineer-in-Charge.
In flooring on a bed of 10mm thick mortar 1:4 (1 acid proof cement cement: 4 coarse sand) -
Acid and Alkali resistant tile.
In dado/ skirting on 12mm thick mortar 1:4 (1 acid proof cement: 4 coarse sand) - Acid and
Alkali resistant tile.
Providing and laying Vitrified tiles in floor and wall in different sizes (thickness to be
specified by the manufacturer) with water absorption less than 0.08% and conforming to
IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick
cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm
including providing uniform grooves, grouting the joints with white cement and matching
pigments etc complete as per approved design, drawing. The tiles must be cut with the zero
chipping diamond cutter only. Laying of tiles will be done with the notch trowel, plier,
wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles
gently and easily.
11.41A.1.1 a) Double charged vitrified tile polished finish of size 600 x 600mm as per approved sample. Sqm 475 1,453.65 690,483.75
Digitally signed by ARTI
DSR Item Ref. S. No. Description of Items Unit Quantity Rate (INR)
Providing and laying Ceramic glazed floor tiles of size 300x300mm (thickness to be specified
by the manufacturer) of 1st quality confirming to IS: 15622 of approved make in colours
such as White, Ivory, Grey, Fume Red Brown, laid on 20mm thick cement mortar 1:4 (1
11.37 7.3 Cement: 4 Coarse Sand), jointing with grey cement slurry @3.3 kg/ sqm including pointing Sqm 152 1,096.55 166,675.60
the joints with white cement and matching pigment etc. complete as per approved sample.
(On inside walls and floors of Under Ground and Over Head Water Tanks etc. complete).
Providing and fixing Heat Resistant Terrace Tiles (300 mm x 300 mm x 20 mm) with SRI
(solar refractive index) > 78, solar reflection > 0.70 and initial emittance > 0.75 on
waterproof and sloped surface of terrace, laid on 20 mm thick cement sand mortar in the
ratio of 1:4 (1 cement : 4 coarse sand) and grouting the joints with mix of white cement &
marble powder in ratio of 1:1, including rubbing and polishing of the surface upto 3 cuts
complete, including providing skirting upto 150 mm height along the parapet walls in the
Providing and laying Kota stone slab flooring over 20mm (average) thick base laid over and
jointed with grey cement slurry mixed with pigment to match the shade of the slab,
including rubbing and polishing complete with base of cement mortar 1:4 (1 cement: 4
Providing and laying Kota stone slab 20mm thick in risers of steps, skirting, dado and pillars
11.27 7.6 laid on 12mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with Sqm 562 2,354.70 1,323,341.40
grey cement slurry mixed with pigment to match the shade of the slab, including rubbing
and polishing complete.
11.31 7.7 Extra for pre-finished nosing in treads of steps of Sand stone slabs. Metre 797 191.40 152,545.80
Extra for Kota stone in treads of steps and risers using single length above normal size upto
Providing and fixing 18mm thick gang saw cut mirror polished premoulded and prepolished)
machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations
of required size of approved shade, colour and texture laid over 20mm thick base cement
mortar 1:4 (1 cement: 4 coarse sand) with joints treated with white cement, mixed with
matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to
edge to give high gloss finish etc complete at all levels.
8.2.2 a) Granite stone slab of all colur black, cherry/ ruby red. -
ii) Area of Slab over 0.50 Sqm Sqm 73 5,136.30 374,949.90
Providing and fixing 1st quality ceramic glazed floor tiles confirming to IS: 15622 (thickness
to be specified by the manufacturer) of apporved sizes, make in all colours, shades except
burgundy, bottle green, black of any size as approved by Engineer-in-Charge in skirting,
risers of steps and dados over 12mm thick bed of cement mortar 1:3 (1 cement: 3 coarse
sand) and jointing with grey cement slurry @ 3.3 kg per sqm including pointing in white
cement mixed with pigment of matching shade complete.
Digitally signed by ARTI
DSR Item Ref. S. No. Description of Items Unit Quantity Rate (INR)
Providing and fixing machine cut, mirror/ eggshell polished, granite stone work for wall
lining (veneer work) including dado, skirting, risers of steps etc., in required design and
pattern wherever required, stones of different finished surface texture, on 12 mm (average)
thick cement mortar 1:3 (1 cement : 3 coarse sand) laid and jointed with white cement
DSR Based - 8.11 7.11 slurry @ 3.3 kg/sqm including pointing with white cement slurry admixed with pigment of -
matching shade, including providing moulding, rubbing, curing, polishing etc. all complete as
per Architectural drawings, and as directed by the Engineer-in-Charge. (Wall Dado and
Polished Granite stone slab of colour Black, Cherry/ Ruby Red or approved equivalent as per
approved sample.
Total Carried Over to Summary: - 18,540,035.43 -
8.0 Wood Work: -
Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-
9.21 8.1 decorative type, core of block board construction with frame of 1st class hard wood and -
well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on
both faces of shutters:
9.21.1 a) 35 mm thick including ISI marked Stainless Steel butt hinges with necessary SS screws. Sqm 95 2,392.65 227,301.75
35 mm thick including ISI marked stainless steel butt hinges with necessary screws and
cutting rebate in double leaf flush door shutters.
Deduct for not providing hinges in doors, windows or clerestory window shutters with ISI
9.15.1.1 8.2 marked Stainless Steel butt hinges with stainless steel screws for wooden doors and Sqm 409 -253.30 -103,599.70
Extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all
9.23 8.3 edges of flush door shutters (over all area of door shutter to be measured). Sqm 386 462.35 178,467.10
Providing 40x5 mm flat iron hold fast 400 mm long including fixing to frame with 10 mm
9.53 8.4 diameter bolts, nuts and wooden plugs and embedding in cement concrete block Nos. 1,445 228.85 330,688.25
300x100x150 mm 1:3:6 mix (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm
Extra for providing vision panel not exceeding 0.1 sqm in all type of flush doors (cost of glass
excluded) (overall area of door shutter to be measured)
9.24.1 a) Rectangular or square sqm 388 199.15 77,270.20
Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats,
9.48.1 8.6 square or round bars etc. including priming coat with approved steel primer all complete. Kg 5,658 219.10 1,239,667.80
Fixed to steel windows by welding.
Providing and fixing chrome plasted bright finished brass door latch of size 300 x 16 x 5mm
with necessary SS screws etc. complete.
Providing and fixing bright finished brass hanging type floor door stopper with necessary
screws etc complete
9.92 8.9 Providing and fixing chromium plated brass handles with necessary screws etc. complete. - -
DSR Item Ref. S. No. Description of Items Unit Quantity Rate (INR)
Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws
Providing and fixing non load bearing fixed frame for fire resistant doors for 120 minutes
fire rating, made out to a profile of dimension 60 mm x 70 mm of 1.6 mm thick galvanised
steel sheet as per test evidence suitable for fixing fire rated door for 120 minutes of both
integrity & radiation control (EW120) & minimum 20 minutes of insulation (EI20).The profile
has to be fixed to the supporting construction by means of anchor fasteners of size M10 x
80, every 150 mm from the edges and every 500 mm (approx) c/c. Linear measurement of
9.163 8.11 frame shall be measured for payment. The frame shall be filled with mineral wool insulation Rmt 113 2,202.90 248,927.70
of density minimum 96kg/ cum and finished with a approved fire resistant primer or powder
coating of not less than 30 micron in desired shade as per NBC 2016, IS 16231 (Part 3):2016
and directions of Engineer - in- Charge.
Providing and fixing 60mm thick glazed fire resistance door of 120 minutes Fire rating
confirming to IS: 3614 (Part II) or EN1634-1:1999, tested and certified as per laboratory
approved by Engineer-in-Charge, with suitable mounting on door frame, consisting of
vertical styles, top rail & side rail 60mm x 60mm wide and bottom rail of 110mm x 60mm
made out of 1.6mm thick G.I. sheet (zinc coating not less than 120 gm/ sqm) duly filled
9.162 8.12 mineral wool insulation having density monimum 96 kg/ cum and fixing with necessary Sqm 76 12,017.90 913,360.40
stainless steel ball bearing hinges of size 100x89x3mm of approved make, including applying
a coat of approved fire resistant primer or powder coating not less than 30 micron etc. all
complete as per direction of Engineer-in-Charge.
Providing and fixing glazing in fire resistant door shutters, fixed panels & partitions etc., with
G.I. beading made out of 1.6 mm thick G.I. sheet (zinc coating not less than 120 gm/sqm) of
size 20 x 33 mm screwed with M4 x 38 mm SS screws at distance 75 mm from the edges
and 150 mm c/c , including applying a coat of approved fire resistant primer/ powder
coating of not less than 30 micron on G.I. beading, & special ceramic tape of 5 x 20 mm size
etc complete in all respect as per NBC 2016, IS 16231 (Part 3):2016 and as per direction of
Engineer-in-Charge with glass of required thickness having 120 minutes of fire resistance
9.164 8.13 both integrity & radiation control (EW120) and minimum 20 minutes of insulation (EI20). Sqm 2 43,677.65 87,355.30
The manufacturer have to give test report/certification of fire glass and the glass should
have the stamp showing the value of E, EW & EI. The glass shall be tested in approved NABL
accredited lab or by any other accreditation body which operates in accordance with
ISO/IEC 17011 and accredited labs as per ISO/IEC 17025 for testing and calibration scopes
shall be eligible. The maximum glazing size shall not be more than 1100x2200 mm (w x h) or
Digitally signed by ARTI
DSR Item Ref. S. No. Description of Items Unit Quantity Rate (INR)
Providing and fixing panic bar/ latch (Double point) fitted with a single body, Trim Latch &
9.139 8.14 Lock on back side of the Panic Latch of reputed brand and manufacture to be approved by Nos. 25 8,366.15 209,153.75
the Engineer- in- charge, all complete.
Providing and fixing Fiber Glass Reinforced plastic (FRP) Door Frames of cross-section 90mm
x 45mm having single rebate of 32mm x 15mm to received shutter of 30mm thickness. The
laminate shall be moulded with fire resistant grade unsaturated polyester resin and
chopped mat. Door frame laminate shall be 2mm thick and shall be filled with suitable
wooden block in all the three legs. The frame shall be covered with fibre glass from all sides.
M.S. stay shall be provided at the bottom to steady the frame.
Providing and fixing to existing door frames 30mm thick Fibreglass Reinforced Plastic (F.R.P.)
flush door shutter in different plain and wood finish made with fire retardant grade
unsaturates polyester resin, moulded to 3 mm thick FRP laminate all around, with suitable
9.122.2 8.16 wooden blocks inside at required places for fixing of fittings and polyurethane foam (PUF)/ Sqm 111 4,488.95 498,273.45
polystyrene foam to be used as filler material throughout the hollow panel, casted
monolithically with testing parameters of F.R.P. laminate confirming to table - 3 of IS:
14856, complete as per directions of Engineer-in-Charge.
Total Carried Over to Summary: - 5,820,274.30 -
9.0 Steel Work: -
Providing and fixing factory made ISI marked steel glazed doors, windows and ventillators,
side/ top/ centre hung, with beading and all members such as F7D, F4B, K11B and K12B etc.
complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars
tenoned and riveted, including providing and fixing of hinges, pivots, priming coat of
approved steel primer, but excluding the cost of other fittings, glass panes complete all as
per approved design, (sectional weight of only steel members shall be measured for
Fixing with 15x3mm lugs 10cm long embedded in cement concrete block 15x10x10 cm of
C.C. 1:3:6 (1 cement: 3 coarse sand: 6 graded stone aggregate 20mm nominal size).
Providing and fixing angle iron/ T iron frames for doors, windows and ventillators of mild
steel Angle sections of size 40 x 40 x 5mm, joints mitred and welded by angle iron 40 x 40 x
10.31 9.2 5mm or 40 x 5mm flat pieces to the existing T-iron frame or to the wall with dash fasteners, Kg 3,531 130.50 460,795.50
including fixing of necessary butt hinges and screws and applying a priming coat of
approved steel primer, all complete as per the direction of Engineer-in-Charge.
Steel work welded in built up sections/ framed work including cutting, hoisting, fixing in
position and applying a priming coat of approved steel primer using structural steel etc as
required - In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works
all complete as per design and drawing and instructions of Engineer-in-Charge.
Digitally signed by ARTI
DSR Item Ref. S. No. Description of Items Unit Quantity Rate (INR)
Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes, channels,
plates etc., including welding, grinding, buffing, polishing and making curvature (wherever
required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c
fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel
10.28 9.4 bolts etc., of required size, on the top of the floor or the side of waist slab with suitable Kg 4,262 772.40 3,291,968.80 -
arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of
stainless steel members shall be considered excluding fixing accessories such as nuts, bolts,
fasteners etc.).
Providing and fixing glass panes with putty and glazing clips in steel doors, windows,
clerestory windows, all complete with 4.0 mm thick glass panes.
Supplying and fixing rolling shutters of approved make, made of required size M.S. laths,
interlocked together through their entire length and jointed together at the end by end
locks, mounted on specially designed pipe shaft with brackets, side guides and
arrangements for inside and outside locking with push and pull operation complete,
10.6.1 9.6 including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured Sqm 2 3,653.20 7,306.40 -
from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S.
top cover of required thickness for rolling shutters. 80 x 1.25mm MS laths with 1.25mm
thick top cover.
ProvidingmmandM.S. laths
fixing ballwith 1.25for
bearing mm thick shutters.
rolling top cover Each 2 492.35 984.70 -
Extra for providing mechanical device chain and crack operation for operating rolling
Extra for providing grilled rolling shutters manufactured out of 8mm dia MS bars instead of
laths as per design approved by Engineer-in-Charge. (Area of grill to be measured).
Total Carried Over to Summary: - 6,372,060.15 -
10.0 Finishing: -
18mm cement plaster in 2 coats under layer 12mm thick cement plaster 1: 5 (1 cement: 5
coarse sand) finished with a top layer 6mm thick cement plaster 1: 6 (1 cement: fine sand).
Extra for providing and mixing water proofing material in cement plaster work in proportion
recommended by the manufacturers.
Extra for plastering exterior walls of height more than 10 m from ground level for every
additional height of 3 m or part thereof.
Providing and fixing chicken wire mesh 24 gauge & 12 mm mesh and 300 mm width for
construction joints, RCC and masonry joints and chasing in brick work for electrical conduits
or water supply pipes including cement slurry and pegs/nails with nailing machine as
required before plastering etc. complete
5.30 10.5 Add for plaster drip course/ groove in plastered surface or moulding to R.C.C. projections. Rm 1,129 78.40 88,513.60 -
15 mm cement plaster on the rough side of single or half brick wall of mix 1:6 (1 cement: 6
coarse sand) 10
13.16.1 10.7 6 mm thick cement plaster of mix 1:3 (1 cement : 3 fine sand) Sqm 6,797 300.45Digitally signed by ARTI
DSR Item Ref. S. No. Description of Items Unit Quantity Rate (INR)
Providing and applying white cement based putty of average thickness 1 mm, of approved
13.80 10.8 brand and manufacturer, over the plastered wall surface to prepare the surface even and Sqm 23,315 156.05 3,638,305.75
smooth complete.
Wall painting with acrylic emulsion paint of interior grade, having VOC (Volatile Organic
Compund) content less than 50 grams/ litre of approved brand and manufacture to give an
even shade: Including applying Two or additional wherever required to achieve even shade
Applying priming coat with primer of approved brand and manufacture, having low VOC
(Volatile Organic Compound) conten. With water thinnable cement primer on wall surface
having VOC content less than 50 grams/ litre including preparation of surfaces etc. complete
in all respect.
Finishing walls with Acrylic Smooth exterior paint of required shade: New work (Two or
13.46.1 10.11 more coats applied @ 1.67 ltr/ 10 sqm) over and including priming coat of exterior primer Sqm 8,433 160.60 1,354,339.80
applied @ 0.90 kg/ 10 sqm.
Material and labour for finishing with Deluxe Multi surface paint system for interiors and
exteriors using Primer as per manufacturers specifications :
Painting wood work with Deluxe Multi Surface Paint of required shade. Two or more coat
applied @ 0.90 ltr/10 sqm over an under coat of primer applied @0.75 ltr/10 sqm of
approved brand and manufacture including preparation of surfaces etc. complete in all
Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more
13.48.3 b) coat applied @ 0.90 ltr/ 10 sqm over an under coat of primer applied @ 0.80 ltr/ 10 sqm of Sqm 1,598 170.70 272,778.60
approved brand and manufacture including preparation of surfaces complete in all respect.
13.37 10.13 White washing with lime to give an even shade: - -
i) New work (three or more coats) Sqm 1,136 39.05 44,360.80
Providing and applying creative artwork painting on walls and elsewhere required in
approved design and pattern with acrylic smooth exterior grade paint of approved shade
with necessary base preparation, priming coat of exterior primer, sealing the entire work
with non-yellowing acrylic varnish as sealer including the cost of T&P, scaffolding etc. all
complete to satisfaction of Engineer-in-Charge.
Total Carried Over to Summary: - 19,928,167.23 -
11.0 Road Works: -
Preparation and consolidaion of sub grade with power road roller of 8 to 12 tonne capacity
after excavating earth to an average of 22.5 cm depth, dressing to camber and consolidating
16.1 11.1 with road roller including making good the undulations etc. and re-rolling the sub garde and Sqm 3,720 218.90 814,308.00 -
disposal of surplus earth lead upto 50 metres.
Extra for compaction of earth work in embankment under optimum moisture conditions to
give atleast 95% of the maximum dry density (proctor density).
16.3 11.3 Supplying and stacking at site - -
16.3.1 a) 90mm to 45mm size stone aggregate Cum 471 2,098.40 988,346.40 11
Digitally signed by ARTI
DSR Item Ref. S. No. Description of Items Unit Quantity Rate (INR)
16.3.2 b) 63mm to 45mm size stone aggregate Cum 471 1,636.05 770,579.55
16.3.6 c) Stone screening 13.2mm nominal size (type A) Cum 154 2,034.35 313,289.90
Laying spreading and compacting stone aggregate of specified sizes to WBM specifications
including spreading in uniform thickness, hand picking, rolling with 3 wheeled
road/vibratory roller 8-10 tonne in stages to proper grade and camber applying and
brooming requisite type of screening/binding material to fill up interstices of coarse
aggregate watering and compacting to the required density.
Supplying, stacking and spreading 6mm thick red bajri, watering and rolling complete
including preparation of the surface and rolling With road roller/hand roller.
Providing and laying design mix cement concrete of M30 grade in roads, taxi tracks/
runways, using cement content as per design mix, using coarse sand and graded stone
aggregate of 40mm nominal size in appropriate proportions as per specified design criteria,
providing dowel bars with sleeves/ tie bars wherever required, laying at site, spreading and
compacting mechanically by using needle and surface vibrators, levelling to required slope/
camber, finished with required texture including steel form work with sturdy MS channel
16.43.1 11.6 sections, curing, making provisions for contraction/ expansion, construction & longitudinal Cum 613 10,529.35 6,454,491.55
joints (10mm wide x 50mm deep) by groove cutting machine, providing and filling joints
with approved joint filler and sealant, complete all as per directions of Engineer-in-Charge.
(Note: Cement content considered in M30 is @340 kg/cum. Excess/ less cement used as per
design mix is payable/ recoverable separately).
Extra for providing and mixing hardening compound of approved quality as per
manufactures specification in cement concrete.
Providing and fixing in position pre - moulded joint filler in expansion joints of RCC roads/
CC pavements after making the joints dust free with high pressure air jet cleaners, all per cm
complete as per the directions of Engineer-in-Charge. (Pre-moulded joint fillers shall be depth per
16.45 11.8 made of bitumen hot sealing compund impregnated fibre board having impregnation more cm width 420 5.30 2,226.00 -
than 35% confirming to IS: 1838 for fibre board and IS: 1834 for hot sealing bitumen per m
compound grade A). length
Providing and filling in position rubberised bitumen hot sealing compound for sealing of depth per
16.46.1 11.9 expansion joints in roads/ pavements all complete as per the directions of Engineer-in- cm width 420 8.65 3,633.00 -
Digitally signed by ARTI
DSR Item Ref. S. No. Description of Items Unit Quantity Rate (INR)
Providing and laying at or near ground level factory made kerb stone of M-25 grade cement
in position to the required line, level and curvature jointed with cement mortar 1:3 (1 cemnt
: 3 coarse sand) including making joints with or without grooves (thickness of joints except
16.69 11.10 at sharp curve shall not to more than 5mm) including making drainage opening wherever Cum 72 10,117.60 728,467.20 -
required complete etc. as per direction of engineer in charge (length of finished kerb edging
shall be measured to calculate volume for payment). (Pre cast C.C kerb stone shall be
approved by engineer in charge).
Paver Block: Providing and laying factory made chamfered edge Cement Concrete paver
blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength,
thickness & size/ shape, made by table vibratory method using PU mould, laid in required
colour & pattern over 50mm thick compacted bed of sand, compacting and proper
embedding/laying of inter locking paver blocks into the sand bedding layer through
vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver
blocks as per required size and pattern, finishing and sweeping extra sand. complete all as
per direction of Engineer-in-Charge.
60mm thick cement concrete paver block of M-35 grade with approved colour, design &
Painting runway/ taxi track/ apron marking with adequate nos. of coats to give uniform
finish with road marking paint of superior make as approved by the Engineer-in-Charge,
including cleaning the surface of all dirt, scales, oil, grease and othger foreign material etc.
and lining out complete. New work (Two or more coats).
Providing and fixing concertina coil fencing with punched tape concertina coil 600mm dia 10
metre openable length (total length 90m), having 50 nos. round per 6 metre length, upto 3
m height of wall with existing angle iron 'Y' shaped placed 2.4 m or 3.00 m apart and with 9
horizontal R.B.T. reinforced barbed wire, stud tied with G.I. staples and G.I. clips to retain
horizontal, including necessary bolts or G.I. barbed wire tied to angle iron, all complete as
per direction of Engineer-in-Charge, with reinforced barbed tape (R.B.T.)/ spring core (2.5
mm thick) wire of high tensile strength of 165 kg/sq. mm with tape (0.52 mm thick) and
weight 43.478 gm/ metre (cost of M.S. angle, C.C. blocks shall be paid seperately).
Total Carried Over to Summary: - 12,309,880.30 -
12.0 Water Proofing -
All Waterproofing works shall be executed through specialised agency approved by
Engineer-in-Charge as per approved specification to the entire satisfaction all complete. -
Work performance shall carry guarantee for minimum 10 years against any leakage.
Guarantee shall be executed on a non-judicial stamp paper of Rs. 100/-
Providing & applying terrace slab watrproofing system comprising of 1.2mm thick single-
component polyurethane (PU) membrane combined with 1mm thick PVC membrane on the
NDSR 12.1 RCC slab, ensurig high elongation, tensile strength, and long-term durability, with all surface Sqm 1,554 2,019.00 - 3,137,526.00
cleaned to expose hairline cracks and aggregate texture prior to application.
Providing & applying eco-friendly epoxy primer and two coats of single-component PU
NDSR 12.2 waterproofing with 0.3mm PVC membrane, total thickness > 1.2mm on prepared concrete. Sqm 417 818.00 - 341,106.00 13
Digitally signed by ARTI
DSR Item Ref. S. No. Description of Items Unit Quantity Rate (INR)
Providing and laying protective screeding/ grading for water proofing treatment with
22.14 12.3 cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal cum 42 8,042.30 337,776.60
Providing and laying integral cement based treatment for waterproofing on horizontal
22.1 12.4 surface at all depth below ground level for under ground structures as directed by Engineer- -
in-charge and consisting of:
i) Ist layer of 22 mm to 25 mm thick approved and specified rough stone slab over a 25mm
thick base of cement mortar 1:3 (1 cement : 3 coarse sand) including applying twice (at
base and top of mortar) cement slurry @ 2.2kg/sqm (each time) mixed with water proofing
compound conforming to IS:2645 in the recommended proportion over the levelling course -
(levelling course to be paid seperately). Joints sealed and grouted with cement slurry mixed
with water proofing compound.
ii) 2nd layer of 25mm thick cement mortar 1:3 (1 cement : 3 coarse sand) mixed with water
proofing compound in recommended proportions.
iii) Finishing top with stone aggregate of 10mm to 12mm nominal size spreading @ 8
cudm/sqm thoroughly embedded in the 2nd layer.
i) Using rough Kota stone Sqm 74 1,515.60 112,154.40
Providing and laying integral cement based treatment for water proofing on the vertical
surface by fixing specified stone slab 22mm to 25 mm thick with cement slurry mixed with
water proofing compound conforming to IS:2645 in recommended proportions with a gap
of 20mm (minimum) between stone slabs and the receiving surfaces and filling the gaps
with neat cement slurry mixed with water proofing compound and finishing the exterior of
stone slab with cement mortor 1:3 (1 cement:3 coarse sand) 20mm thick with neat cement
punning mixed with water proofing compound in recommended proportion complete at all
levels and as directed by Engineer-in-charge.
i) Using rough Kota stone Sqm 129 2,024.70 261,186.30
Providing water proofing treatment by chemical injection grout process on horizontal &
vertical surfaces like rafts, retaining walls & other similar locations using 25mm dia . G.I
nozzles, minimum 1/4th thickness of raft 40mm(long) whichever is more inside the raft
fixed @ 0.75m c/c in both the directions. The injection grout which consist of injection
cement slurries of different viscosities & expansive plasticizing agent (a non shrinkage
compensating grout) is to be pumped in to the nozzles under pressure with a pump . The
nozzles to be sealed off after the injection operation with suitable admixture. Providing &
applying two coats of acrylic latex cementitious coatings in the ratio 3:1 (3 parts of cement
:1 part acrylic polymer latex) keeping water cement ratio as per manufacture's
specifications , 20mm cement plaster of mix 1:4 (1 cement :4 coarse sand) mixed with liquid
waterproofing admixture & finally embedding with 12mm size stone aggregate @ 8cudm
per sqm complete as per manufacturer's specifications & as directed.
Digitally signed by ARTI
DSR Item Ref. S. No. Description of Items Unit Quantity Rate (INR)
Bore Packing: All the borehole gaps between concrete surface and pvc pipe of various dia
upto the neck level shall be filled with non-shrink free flow grout - SmartCare GP Grout or
approved equivalent having dual shrinkage compensation property and than apply epoxy
primer at perferi of the pipe than apply two quote of FlexiSeal PU US or approved equiv.
coating. Before the bore packing, surface of the pvc pipe and concrete surface will be made
rough and sand will be sprinkled with polymer bonding agent.
Providing & applying two coats of 2-component acrylic cementitious coating followed by
food-grade epoxy coating on the inner side of the tank.
Providing & applying two coats of 2-component acrylic cementitious coating followed by
coal tar epoxy coating on the inner side of the tank.
Providing and placing in position suitable PVC water stops confirming to IS: 12200 for
22.4.1 12.10 construction/ expansion joints between two RCC members and fixed to the reinforcement Rmt. 49 327.65 16,054.85
with binding wire before pouring concrete etc. complete: Serrated with central bulb
(225mm wide, 8-11mm thick).
Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4
(1 cement: 2 coarse sand: 4 graded stone aggregate of 20mm nominal size) over PVC sheet
12.22 12.11 1mx1mx400 micron, finished with 12mm cement plaster 1:3 (1 cement: 3 coarse sand) and Each 29 298.25 8,649.25
a coat of neat cement, rounding the edges and making and finishing the outlet complete.
Total Carried Over to Summary: - 735,821.40 3,993,452.00
13.0 Structural Glazing & Façade Works -
Providing and supplying aluminium extruded tubular and other aluminium sections as per
the architectural drawings and approved shop drawings, the aluminium quality as per grade
25.1 13.1 6063 T5 or T6 as per BS 1474, including super durable powder coating of 60-80 microns -
conforming to AAMA 2604 of required colour and shade as approved by the Engineer in
(The item includes cost of material such as cleats, sleeves, screws etc. necessary for
fabrication of extruded aluminium frame work. Nothing extra shall be paid on this account). Kg 485 414.30 200,935.50
The weight of aluminium extruded section shall be taken for purpose of payment.
Designing, fabricating, testing, protection, installing and fixing in position semi (grid)
unitized system of structural glazing (with open joints) for linear as well as curvilinear
portions of the building for all heights and all levels including:
Structural analysis, design and preparation of shop drawings for the specified design loads
conforming to IS 875 part III (the system must passed the proof test at 1.5 times design
wind pressure without any failure) including functional design of the aluminium sections for
fixing glazing panels of various thicknesses, aluminium cleats, sleeves and splice plates etc.
a) gaskets, screws, toggles, nuts, bolts, clamps etc. structural and weather silicone sealants, - -
flashings, fire stop (barrier) cum smoke seals, microwave cured EPDM gaskets for water
tightness, pressure equalisation and drainge and protection against fire hazard including:
Digitally signed by ARTI
DSR Item Ref. S. No. Description of Items Unit Quantity Rate (INR)
Fabricating and supplying serrated MS hot dip galvanized/ aluminium alloy of 6005 T5
brackets of required sizes, sections and profiles etc. to accommodate 3 dimentional
movement for achieving perfect vertically and proper fixing of structural glazing system with
b) the RCC/ masonary/ structural steel framework of building structure, using stainless steel - -
anchor fasteners/ bolts, nylon seperator to prevent bimetallic contacts with nuts and
washers etc. of stainless steel grade 316, of the required capacity and in required numbers.
Providing and filling, two part pump filled, structural silicone sealant and one part weather
silicone sealant compatible with the structural silicone sealant of required bite size in a
c) clean and controlled factory/ work shop environment, including double sided spacer tape, - -
setting blocks and backer rod, all of approved grade, brand and manufacturer, as per the
approved sealant design, within and all around the perimeter for holding glass.
Providing and fixing in position flashings of solid aluminium sheet 1 mm thick and of sizes,
d) shapes and profiles, as required as per the site conditions, to seal the gap between the - -
building structure and all its interfaces with curtain glazing to make it watertight.
Making provision for drainage of moisture/ water that enters the curtain glazing system to
e) make it watertight, by incorporating principles of pressure equilization, providing suitable - -
gutter profiles at bottom (if required) making necessary holes of required sizes and of
required numbers etc. complete.
This item includes cost of all inputs of designing, labour for fabricating and installation of
aluminium grid, installation of glazed units, T & P, scaffolding and other incidental charges
including wastages etc. enabling temporary structures and services, cranes or cradles etc. as - -
described above and as specified. The item includes the cost of getting all the structural and
functional design including shop drawings checked by a Structural designer, duly approved
by Engineer-in-Charge.
The item also includes the cost of all mock ups at site, cost of all samples of the individual
components for testing in an approved laboratory, field tests on the assembled working
structural glazing as specified, cleaning and protection till the handing over of the building
for occupation. In the end, the contractor shall provide a water tight structural glazing sqm 111 3,510.50 389,665.50
having all the performance characteristics etc. all complete as required, as per the
Architectural drawings, as per item description, as specified, as per the approved shop
drawings and as directed by the Engineer in Charge.
Extra for openable side/ top hung vision glass panels (GUs) including providing and
supplying at site all accessories and hardwares for the openable panels as specified and of
the approved make such as heavy duty stainless steel friction hinges, min 4 point cremone
locking sets with stainless steel plates, handles, buffer etc. incluiding necessary stainless
25.4 13.3 steel screws/ fasteners, nuts, bolts, washers etc. all complete as per the approved shop sqm 7 3,671.50 25,700.50
drawings, as specified and as directed by the Engineer in Charge.
Digitally signed by ARTI
DSR Item Ref. S. No. Description of Items Unit Quantity Rate (INR)
Providing and supplying Glass Panels comprising of 6mm thick heat strengthened monolithic
float glass of approved colour and shade with reflective soft coating on surface # 2 of
approved colour and shade so as to match the spandrel glass colour and shade of the GUs in
the vision panels etc., all complete for the required performances as specified, as per the
Architectural drawings, as per the approved shop drawings, as specified, and as directed by
25.6 13.4 the Engineer- in- Charge. For payment, only the actual area of glass on face # 1 of the glass - -
panels (but excluding the area of grooves and weather silicone sealant) provided and fixied
in position, shall be measured in sqm. (Payment for fixing of Glass Panels in the curtain
glazing is included in cost of relevent item").
i) Coloured tinted float glass 6mm thick substrate with reflective soft coating on face # 2 of
approved make and properties as Visible Light transmittance (VLT) of 25 to 35%, Light
reflection internal 10 to 15% light reflection external 10 to 20%, shading coefficient (0.25 - sqm 111 2,450.15 271,966.65
0.28) and U value of 3.0 to 3.3 W/m2 degree K etc. The properties of performance glass
shall be decided by technical sanctioning authority as per the site requirement.
Designing, fabricating, testing, installing and fixing in position Curtain wall with Aluminium
8.32 13.5 Composite Panel Cladding, with open grooves for linear as well as curvilinear portions of the - -
building, for all heights and all levels etc. including:
a) Structural analysis & design and preparation of shop drawings for pressure equalisation
or rain screen principle as required, proper drainage of water to make it watertight - -
including checking of all the structural and functional design.
b) Providing, fabricating and supplying and fixing panels of aluminium composite panel
cladding in pan shape in metalic colour of approved shades made out of 4mm thick
aluminium composite panel material consisting of 3mm thick FR grade mineral core
sandwiched between two aluminium sheets (each 0.5mm thick). The aluminium composite
panel cladding sheet shall be coil coated, with Kynar 500 based PVDF/ Lumiflon based - -
flyoropolymer resin coating of approved colour and shade on face # 1 and polymer (service)
coating on face # 2 as specified using stainless steel screws, nuts, bolts, washers, cleats,
weather silicone sealant, backer rods etc."
c) The fastening brackets of Aluminium alloy 6005 T5/MS with Hot Dip Galvanised with
serrations and serrated washers to arrest the wind load movement, fasteners, SS 316 Pins
and anchor bolts of approved make in SS 316, Nylon separators to prevent bi-metallic - -
contacts all complete required to perform as per specification and drawing.
The item includes cost of all material and labour component, the cost of all mock ups at site,
cost of all smaples of the individual components for testing in an approved laboratory, field
tests on the assembled working curtain wall with aluminuium composite panel cladding,
cleaning and protection of the curtain wall with aluminium composite panel cladding till the - -
handing over of the building for occupation. Base frame work for ACP cladding is payable
under the relevant aluminium item.
Digitally signed by ARTI
DSR Item Ref. S. No. Description of Items Unit Quantity Rate (INR)
The Contractor shall provide curtain wall with aluminium composite panel cladding, having
all the performance characteristics all complete, as per the Architectural drawings, as per - -
item description, as specified, as per the approved shop drawings and as directed by the
Engineer-in-Charge.
However, for the purpose of payment, only the actual area on the external face of the
curtain wall with Aluminium Composite Panel Cladding (including width of groove) shall be sqm 118 5,015.05 591,775.90
measured in sqm. upto two decimal places.
Designing, fabricating, installing and fixing in facade elevation factory made 18mm thick
single extruded WPC (Wood Polymer Composite) solid plain white colour board Jali, CNC
(Computer numeric control) routed of approved design by Engineer-in-charge which are
machine cut for duct/ shaft covering, partitions and facades comprising of virgin polymer of
K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/
rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms)
having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face)
NDSR 13.6 minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and Sqm 76 5,221.00 - 396,796.00
resistance to spread of flame of Class A category with properties of being termite/ borer
proof, water/ moisture proof and fire retardant and fixing on M.S (mild steel) frame made of
25 x 25 x 1.5 mm square hollow box section with necessary stainless steel fasteners and SS
screws etc., all complete as per direction of Engineer-In-Charge. (Note: M.S. framework
required for support and shall be paid in basic item).
Total Carried Over to Summary: - 1,480,044.05 396,796.00
13.0 Dismantling and Demolishing: -
Demolishing RCC work manually/ by mechanical means including stacking of steel bars and
15.3 13.1 disposal of unserviceable material within 50 metres lead as per direction of Engineer-in- Cum 8 3,551.25 28,410.00
Demolishing 1:4:8 cement concrete work manually/ by mechanical including disposal of
material within 50 metres lead as per direction of Engineer-in-Charge.
Demolishing brick work in cement mortar manually/ by mechanical means including stacking
15.7.4 13.3 of serviceable material and disposal of unserviceable material within 50 metres lead as per Cum 10 2,060.20 20,602.00
direction of Engineer-in-Charge.
Disposal of building rubbish/ malba/ similar unserviceable, dismantled or waste material by
mechanical means, including loading, transporting, unloading to approved municipal
dumping ground or as approved by Engineer-in-charge, beyond 50m initial lead, for all leads
inluding all lifts involved.
Total Carried Over to Summary: - 60,833.30 -
14.0 Rain Water Harvesting: -
Digitally signed by ARTI
DSR Item Ref. S. No. Description of Items Unit Quantity Rate (INR)
Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in
foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including
2.8.1 14.1 dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the Cum 198 260.30 51,539.40
excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m., All
Providing and laying in position cement concrete of specified grade excluding the cost of
centering and shuttering - All work up to plinth level :, 1:4:8 (1 Cement : 4 coarse sand (zone-
III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived
from natural sources).
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in
foundation and plinth in:, Cement mortar 1:4 (1 cement : 4 coarse sand)
12 mm cement plaster finished with a floating coat of neat cement of mix 1:3 (1 cement: 3
Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method
prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing
and submitting strata chart/ bore log, including hire & running charges of all equipments,
tools, plants & machineries required for the job, all complete as per direction of Engineer -in-
charge,beyond 90 metre & upto 150 metre depth below ground level., All types of soil, 300
Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) with
R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 coarse sand (zone-III) : 3 graded stone
aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand
(zone-III) : 8 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick
with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat
19.7.1.1 14.6 cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand: 4 graded Nos. 12 12,770.55 153,246.60
stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete
as per standard design :, Inside size 90x80 cm and 45 cm deep including C.I. cover with
frame (light duty) 455x610 mm internal dimensions, total weight of cover and frame to be
not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) :, With common burnt
clay F.P.S. (non modular) bricks of class designation 7.5.
Providing, laying and jointing of 160mm dia PVC pressure pipe of 10 kgf/ sqcm, specials
couplings and fittings to site of work. Lowering the same in to the trenches and laying true
in alignment and gradient including testing of the pipe line. (excluding the cost of trenching
but including the cutting of pipes for making up the length and making joints (Supreme
make or equvalent). Sanctioned Rate.
Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in
23.5 14.8 recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Cum 33 1,509.80 49,823.40
Engineer-in-charge.
Supplying, filling, spreading & leveling gravels of size range 5 mm to 10 mm, in the recharge
23.6 14.9 pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all Cum 18 1,538.25 27,688.50
complete as per direction of Engineer-in-charge. Digitally signed by ARTI
DSR Item Ref. S. No. Description of Items Unit Quantity Rate (INR)
Providing and fixing M.S. clamp of required dia to the top of casing/ housing pipe of
23.14.2 14.10 tubewell as per IS: 2800 (part I), including necessary bolts & nuts of required size complete., No. 1 2,019.05 2,019.05
Supplying, filling, spreading & leveling coarse sand of size range 1.5 mm to 2 mm in recharge
23.7 14.11 pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction Cum 14 1,538.25 21,535.50
of Engineer -in-charge.
Providing and fixing Bail plug/ Bottom plug of required dia to the bottom of pipe assembly
of tubewell as per IS:2800 (part I)., 150 mm dia.
Development of tube well in accordance with IS : 2800 (part I) and IS:11189, to establish
maximum rate of usable water yield without sand content (beyond permissible limit), with
required capacity air compressor, running the compressor for required time till well is fully
developed, measuring yield of well by “V” notch method or any other approved method,
measuring static level & draw down etc. by step draw down method, collecting water
samples & getting tested in approved laboratory, i/c disinfection of tubewell, all complete,
including hire & labour charges of air compressor, tools & accessories etc., all as per
requirement and direction of Engineer-in-charge.
Total Carried Over to Summary: - 718,194.75 -
15.0 Horticulture Work: -
Trenching in ordinary soil up to a depth of 60 cm including removal and stacking of
serviceable materials and then disposing of surplus soil, by spreading and neatly levelling
15.1 within a lead of 50 m and making up the trenched area to proper levels by filling with earth Cum 1,012 119.00 120,428
or earth mixed with sludge or/ and manure before and after flooding trench with water
(excluding cost of imported earth, sludge or manure).
2.2/ DSR 2025 Supplying and stacking of good earth at site including royalty and carriage upto 5 km lead
(H&L) complete (earth measured in stacks will be reduced by 20% for payment).
Supplying and stacking at site dump manure from approved source, including carriage upto
15.3 5 km lead complete (manure measured in stacks will be reduced by 8% for payment): Cum 254 491.65 124,879
Screened through sieve of I.S. designation 4.75 mm.
2.9/ DSR 2025 Mixing earth and sludge or manure in the required proportion specified or directed by the
(H&L) Officer-in-charge
2.8/ DSR 2025 Spreading of sludge, dump manure and/or good earth in required thickness as per direction
(H&L) of officer-in-charge (cost of sludge, dump manure and/ or good earth to be paid separately).
15.6 Rough dressing the trenched ground including breaking clods. Sqm 1,687 2.30 3,880
15.7 Fine dressing the ground Sqm 1,687 5.60 9,447
Digitally signed by ARTI
DSR Item Ref. S. No. Description of Items Unit Quantity Rate (INR)
Grassing with selection No. 1 Doob grass including watering and maintenance of the lawn
2.10.2/ DSR 2025 for 30 days or more till the grass forms a thick lawn, free from weeds and fit for mowing
(H&L) including supplying good earth, if needed (the grass and good earth shall be paid for
separately) - With Turf Grass.
2.6/ DSR 2025 Uprooting weeds from the trenched area after 10 to 15 days of its flooding with water
(H&L) including disposal of uprooted vegetation.
Providing & laying of Selection no. 1 Doob grass turf with earth 50mm to 60mm thickness of
existing ground prepared with proper level and ramming with required tools wooden and
15.10 than rolling the surface with light roller make the surface smoothen and light watering the Sqm 1,687 113.70 191,812
same and maintenance for 30 days or more till the grass establish properly, as per direction
of the officer-in-charge.
Preparation of mounds of various size and shape by available excavated/ supplied earth in
15.11 layers not exceeding 20 cm in depth, breaking clods, watering of each layer, dressing etc., Cum 85 696.20 59,177
lead upto 50 meter and lift upto 1.5 m complete as per direction of Officer-in-charge.
Digging holes in ordinary soil and refilling the same with the excavated earth mixed with
manure or sludge in the ratio of 2:1 by volume (2 parts of stacked volume of earth after
2.14.2/ DSR 2025 reduction by 20% : 1 part of stacked volume of manure after reduction by 8%) flooding with
(H&L) water, dressing including removal of rubbish and surplus earth, if any, with all leads and lifts
(cost of manure, sludge or extra good earth if needed to be paid for separately): Holes 90
cm dia, and 90 cm deep
Preparation of beds for hedging and shrubbery by excavating 60 cm deep and trenching the
excavated base to a further depth of 30 cm, refilling the excavated earth after breaking
clods and mixing with sludge or manure in the ratio of 8:1 (8 parts of stacked volume of
2.13/ DSR 2025 earth after reduction by 20% : one part of stacked volume of sludge or manure after
(H&L) reduction by 8%), flooding with water, filling with earth if necessary, watering and finally
fine dressing, leveling etc. including stacking and disposal of materials declared
unserviceable and surplus earth by spreading and leveling as directed, within a lead of 50 m,
lift up to 1.5 m complete (cost of sludge, manure or extra earth to be paid for separately).
Plantation of Trees, Shrubs, Hedge, ground covers and seasonal plants at site i/c watering
15.14 and removal of unserviceable materials as per direction of officer in charge (excluding cost - -
of plant & water).
2.57.2 b) Shrubs Plant Nos. 345 4.70 1,622
7.11/ DSR 2025 Providing and stacking of Bottle palm ht. 210-240 cm bottom girth 30-35 cm well developed
(H&L) in big HDPE bag as per direction of the officer-incharge.
7.16/ DSR 2025 Providing and stacking of Cassia fistula (Amaltash) height 120-135 cm. in poly bag size 25 cm
(H&L) as per direction of the officer-in-charge.
7.24/ DSR 2025 Providing and stacking of Delonix regia (Gulmohar) height 150-165 cm. in poly bag size 25
(H&L) cm as per direction of the officer-in-charge. 21
Digitally signed by ARTI
DSR Item Ref. S. No. Description of Items Unit Quantity Rate (INR)
Providing and stacking of Ficus benjamina (green) height 150-165 cm., bushy with healthy
15.18 branches and lush green foliage in big size HDPE bag as per direction of the officer-in- each 15 195.00 2,925
7.32/ DSR 2025 Providing and stacking of Ficus infectoria (Pilkhan) height 150-165 cm. in polybag size 25 cm
(H&L) as per direction of the officer-in-charge.
7.34/ DSR 2025 Providing and stacking of Ficus nuda height 120-135 cm. with 6-8 branches and lush green
(H&L) foliage in gunny bag size 25 cm as per direction of the officer-in-charge.
7.44/ DSR 2025 Providing and stacking of Foxtail palm of ht. 240-270 cm bottom girth 35 - 40 cm well
(H&L) developed in big size HDPE bags as per direction of the officer-in-charge.
7.45/ DSR 2025 Providing and stacking of Grevillea Robusta (Silver Oak) height 150-165 cm. in poly bag size
(H&L) 25 cm as per direction of the officer-in-charge.
7.48/ DSR 2025 Providing and stacking of Jacaranda mimosifolia height 150-165 cm. in poly bag size 25 cm
(H&L) as per direction of the officer-in-charge.
7.77/ DSR 2025 Providing and stacking of Polyalthia pendula (Ashok Pendula) height 180-195 cm. in gunny
(H&L) bag size 30 cm as per direction of the officer-incharge.
7.84/ DSR 2025 Providing and stacking of Tabebuia sp. height 150-165 cm. in polybag size 25 cm as per
(H&L) direction of the officer-in-charge.
7.85/ DSR 2025 Providing and stacking of Tamarindus indica (Imli) height 120-150 cm. in polybag size 25 cm
(H&L) as per direction of the officer-in-charge.
7.86/ DSR 2025 Providing and stacking of Tecoma argentea height 120-135 cm. in poly bag size 25 cm as per
(H&L) direction of the officer-in-charge.
8.28/ DSR 2025 Providing and stacking of Ficus panda of height 90-105 cm. with 10-12 branches and healthy
(H&L) foliage, well formed in cement pots of size 30 cm as per direction of the officer-in-charge.
8.24/ DSR 2025 Providing and stacking of Ficus reginald well branched, bushy of height 60-75 cm. in earthen
(H&L) pots of size 25 cm as per direction of the officer-in-charge.
Providing and stacking Duranta Golden, having ht. 15 cm to 20 cm bushy shape with fresh
15.30 and healthy leaves in 15 cm size of Earthen Pot/ Plastic Pot and as per direction of the each 42 22.85 960
officer-in-charge.
6.30/ DSR 2025 Providing and stacking Tradescantia zebrina having in 15 cm size of Earthen Pot/ Plastic Pot
(H&L) and as per direction of the officer-in-charge.
6.31/ DSR 2025 Providing and stacking Wadelia trilobata, full of leaves in 15 cm size of earthen Pot/ Plastic
(H&L) Pot and as per direction of the officer-in-charge.
6.4/ DSR 2025 Providing and stacking Asparagus sprengeri of height 30 cm to 45 cm, full of leafy branches
(H&L) in 20 cm size of Earthen Pot / Plastic Pot and as per direction of the officer-in-charge.
6.21/ DSR 2025 Providing and stacking Ophiopogon jaburan (variegated), full of variegated leaves in 20 cm
(H&L) Earthen Pot/Plastic Pot and as per direction of the officer-in-charge.
Providing and stacking of Washingtonia filifea palm stem ht. 120-135 cm with 8-10 healthy
15.35 leaves lush green leaves well developed in big size HDPE Bags as per direction of the officer- each 50 704.20 35,210
Digitally signed by ARTI
DSR Item Ref. S. No. Description of Items Unit Quantity Rate (INR)
Total Carried Over to Summary: 1,001,704 -
Digitally signed by ARTI
Project Name:- Construction of Kendriya Vidhyalaya at Khajuri Khas, Delhi
DETAILED ESTIMATE OF INTERNAL PLUMBING ESTIMATE
S. No. Description
Amount (in Rs.)
1 SANITARY FIXTURES & FITTINGS 1,566,071 1,028,853
2 INTERNAL WATER SUPPLY 2,113,337 296,109
3 SOIL, WASTE, VENT PIPES, RAIN WATER PIPES & FITTINGS. 173,447 2,156,619
MODIFIED ESTIMATED COST AFTER USING CORRECTION FACTOR ON
DSR 2023 ON ACCOUNT OF GST @0.973
GRAND TOTAL (DSR +NSR) 7,230,409.01
GRAND TOTAL (DSR +NSR) 7,230,409.01
Project Name:- Construction of Kendriya Vidhyalaya at Khajuri Khas, Delhi
Schedule Of Quantity
Total DSR Rate (in DSR Amount (in MR Rate MR Amount
S. No. DSR 2023 Description Unit
Quantity Rs.) Rs.) (in Rs.) (in Rs.)
1.0 SANITARY FIXTURES & FITTINGS
Providing and fixing water closet squatting pan (Indian type W.C. pan) with 100 mm sand
cast iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flushing pipe,
1.1A 17.1 with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and
fixtures complete, including cutting and making good the walls and floors wherever
White Vitreous china Orissa pattern W.C. pan of size 580×440 mm with integral type foot
Providing and fixing white vitreous china extended wall mounting water closet of size
780x370x690mm of approved shape including providing and fixing white vitreous china
1.1 17.78 cistern with dual flushing fitting,of flushing capacity 3 litre/6 litre( adjustable to 4 litre/8 Each 39 14,999.15 584,966.85 -
litres),including seat cover and cistern fittings,nuts,bolts and gasket etc. complete.
Providing and fixing white vitreous china pedestal type water closet (European type) with
seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with
fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard
make and mosquito proof coupling of approved municipal design complete, including
painting of fittings and brackets, cutting and making good the walls and floors wherever
17.3.1 W.C. pan with ISI marked white solid plastic seat & lid. Each 8,006.60 -
Providing and fixing wash basin with C.I. brackets, 15 mm dia CP Brass single hole basin
1.2 17.7A mixer of approved quality and make, including painting of fittings and brackets, cutting and -
making good the walls wherever required:-
a) White Vitreous China Wash basin size 630x450 mm with a 15 mm CP Brass single hole
Providing and fixing kitchen sink with C.I. brackets, C.P. brass chain with rubber plug, 40
mm C.P. brass waste complete, including painting the fittings and brackets, cutting and
making good the walls wherever required:
17.9.1 White glazed fire clay kitchen sink of size 600x450x 250 mm Each 3 3,892.75 11,678.25 -
Providing & Fixing of C.P WALL MOUNTED SWIVEL SPOUT KITCHEN SINK MIXER
with all accessories as per approved specifications, Material: Brass,Size(mm):180(L) x
185(W) x 225(D),Spout Length(mm):135,Mounted : Wall mounted,Series : Rivera , Origin
Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube upto 1 metre long with S.S.
triangular plate to Eureopean type W.C. of quality and make as approved by Engineer - in -
Providing and fixing CP Brass 32mm size bottle trap of approved quality & make and as
per the direction of engineer in charge.
Providing and fixing C.P. brass long nose bib cock of approved quality conforming to IS
standards and weighing not less than 810 gms
1.8 17.34 Providing and fixing toilet paper holder - -
Supply & Installation of Twin Coat Hook:Material:18-8 S, type-304, stainless
steel,Application:WC Cubicle Area,Warranty:1 year , Origin Made In India
Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved
1.1 18.53 quality conforming to IS:8931. - -
Providing and fixing unplasticised P.V.C. connection pipe with PTMT Nuts, collar and
1.11 18.74 bush of approved quality and colour. - -
18.74.2 15 mm nominal bore with 45 cm length Each 163 121.90 19,869.70 -
Providing & fixing of C.P Towel ring, cost inclusive of CP flange, fasteners, complete as per
manufacturer recommendation as per approved specifications , Origin Made In India.
Providing & Fixing of C.P Towel rail with all accessories as per approved specifications,
1.13 MR-4 with 600 mm length, SS 304, and making good the walls wherever required. , Origin Made Each 3 - 950.00 2,850.00
Supply & Installation of S.STEEL SOAP DISPENSER (HEAVY TRAFFFIC) Container : 18-
1.14 MR-5 8 S, Type-304, Stainless Steel Material : Non Corrosive Steel, Capacity : 400 ML, Dispense Each 51 - 2,970.00 151,470.00
Volume : 2 ML , Origin Made In India
Providing and fixing white vitreous china flat back or wall corner type lipped front urinal
basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing
1.15 17.4 cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps -
complete, including painting of fittings and brackets, cutting and making good the walls and
floors wherever required :
17.4.1 One urinal basin with 5 litre white P.V.C. automatic flushing cistern. Each 42 6,258.75 262,867.50 -
Digitally signed by ARTI
Total DSR Rate (in DSR Amount (in MR Rate MR Amount
S. No. DSR 2023 Description Unit
Quantity Rs.) Rs.) (in Rs.) (in Rs.)
Providing and fixing 75 mm high, 50 mm deep and 18 mm thick stone slab table rubbed,
edges rounded and polished, fixed in urinal partitions by cutting a chase of appropriate
1.16 8.10 width with chase cutter and embedding the stone in the chase with epoxy grout or with - -
cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 6 mm nominal
size) as per direction of Engineer-in-charge and finished smooth.
8.10.2 Granite Stone of approved shade Sqm 42 4,051.85 170,177.70 -
Supply and fixing of water cooler fully stainless steel of 60 litres cooling capacity and 120
1.17 MR 6 litres storage capacity, with in-built R.O. system, to be operated on single phase supply with Each 8 - 77,851.00 622,808.00
ISI mark. Each cooler shall be provided with 4 Nos. pressmatic taps for drinking purpose.
Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved
1.18 17.31 quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass Each 51 1,607.95 82,005.45 -
screws and washers complete.
Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste
fittings complete.
17.28.2 Flexible pipe - -
Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS
standards and weighing not less than 690 gms.
Supply & Installation of Disabled S.STEEL GRAB RAIL – 600 MM,32MM DIA.Material
1.21 MR-7 : 18-8 S, Type-304, Stainless Steel, Application : WC Area, Diameter : 32 mm , Origin Each 10 - 2,305.00 23,050.00
Supply & Installation of Auto Closing System Bib Cock, Range:Pressmatic Tap,Flow Rate
1.22 MR-8 (Litre Per Minute),0.5 Bar:7.21,1.0 Bar:9.91,2.0 Bar:13.93,3.0 Bar:17.00 , Origin Made In Each 39 - 2,575.00 100,425.00
Providing & Fixing of Soap Dish with all accessories as per approved specifications of
1.23 MR-9 material 304 stainless steel with chrome plating and making good the walls wherever Each 3 - 578.00 1,734.00
required. , Origin Made In India
Providing and Fixing Electric Hot Water Geyser of Stainless Steel Material Grade 316 with
Inlet and Outlet Connection with 15 mm dia Angle Valve and Geyser (25 LTR)shall be
equipped with inbuilt non return valve and insulation on inner and outer surfaces for
prevention of heat losses 2 nos CP round wall flange and CP Brass Screws and Rawl plugs
all other required accessories Complete in all respect as per direction of Engineer - in -
10.1 Electric Geyser 15 Litre Capacity Each 3 - 10,213.00 30,639.00
10.2 Electric Geyser 25 Litre Capacity Each 3 - 11,659.00 34,977.00
10.3 Electric Geyser 3 Litre instant capacity Each - 7,708.00 -
TOTAL CARRIED OVER TO SUMMARY 1,566,070.70 1,028,853.00
2 INTERNAL WATER SUPPLY
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal
stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c
2.1 18.8 fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with
one step CPVC solvent cement and the cost of cutting chases and making good the same
including testing of joints complete as per direction of Engineer in Charge.
Concealed work, including cutting chases and making good the walls etc. - -
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal
stability for hot & cold water supply, including all CPVC plain & brass threaded fittings,
2.2 18.7 including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & - -
fittings with one step CPVC solvent cement and testing of joints complete as per direction
of Engineer in Charge.
Internal work - Exposed on wall - -
a) 18.7.1 15mm nominal bore Mtr. 286.80 - - -
b) 18.7.2 20mm nominal bore Mtr. 335.00 - -
Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed
Providing and fixing ball valve (brass) of approved quality, High or low pressure, with
plastic floats complete :
18.18.1 15 mm nominal bore Each 406.86 - -
Derrived 32 mm nominal bore Each 51 - 1,789.00 91,239.00
Derrived 40 mm nominal bore Each 52 - 2,382.00 123,864.00
DSR E&M- Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with
2.5 2022 bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets - -
(18.11) conforming to IS 13095 of following sizes as required
Digitally signed by ARTI
Total DSR Rate (in DSR Amount (in MR Rate MR Amount
S. No. DSR 2023 Description Unit
Quantity Rs.) Rs.) (in Rs.) (in Rs.)
Providing and fixing motorized valve with sensor of approved quality, to complete the
a) 40 mm dia ( Flushing Riser) Each 2 - 19,366.00 38,732.00
b) 50 mm dia ( Flushing Riser) Each 2 21,137.00 42,274.00
Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS :
2.7 18.48 12701 marked, with cover and suitable locking arrangement and making necessary holes for 31700 11.00 348,700.00 -
inlet, outlet and overflow pipes but without fittings and the base support for tank.
TOTAL CARRIED OVER TO SUMMARY 2,113,337.14 296,109.00
3 SOIL, WASTE, VENT PIPES, RAIN WATER PIPES & FITTINGS.
Providing and fixing soil, waste and vent pipes
Supplying, Installation, Testing and Commissioning of uPVC pipes type -B conforming to
IS 13592 (1992) for soil, waste and vent pipes including all fittings rubber ring type (plain
3.1 MR-12 or with access door) e.g. bends, junctions, cowls, offsets, access pieces, jointing with rubber
ring joints with lubricant etc. fixed with clamps to walls with cement concrete 1:2:4 blocks
complete in all respects. (For Soil & Waste Pipe)
a) 75 OD mm Metre 424.00 -
c) 160 OD mm Metre 1,674.00 -
Providing, laying, Jointing, Testing and commissioning of uPVC pressure pipes of
6Kg/Sqcm pressure rating class 5 (IS : 4985-2000) including fittings, tees, bends, clamps,
coupling and adaptors supports, and jointing with solvent joint, testing and necessary earth
3.2 MR-13 work in excavation, backfilling, disposal of surplus earth with a lead upto 50m complete, -
compaction and consolidation Including laying cement concrete 1:2:4 alround UPVC pipe
including bed concrete and thrust blocks at bends as per standard design (For Soil & Waste
Supplying, Installation, Testing and Commissioning of uPVC, P or S trap of self cleansing
3.3 MR-14 design with / without vent. arm Setting in cement concrete 1:2:4 mix complete including -
cost of cutting & making good the Wall / Floors wherever required.
Providing and fixing floor drain with jali size 110X50 size inlet and outlet including
cutting and making good the walls and floors wherever required complete in all respects.
Providing and fixing 125 mm dia, 3 mm thick Stainless steel grating with frame for floor
traps or drains of required pattern including cutting and making good the floors complete.
Providing and fixing cast brass Cleanout plug with suitable insert keys for opening in brass
3.6 MR-17 cap, male threaded joint/reducer with G.I. socket caulked to Pipe/fittings of CI pipe -
including cost of lead joints etc. complete in all respect.
Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4
(1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C.
3.7 12.22 sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse each 18 298.25 5,368.50 -
sand) and a coat of neat cement, rounding the edges and making and finishing the outlet
complete.450 X 450mm -
Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS
3.8 12.41 : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm -
gap for thermal expansion, (i) Single socketed pipes.
12.41.1 75 mm diameter Metre 248.80 - -
Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diameter
and weighing not less than 440 grams.
TOTAL CARRIED OVER TO SUMMARY 173,446.95 2,156,619.30
Digitally signed by ARTI
Project Name:- Construction of Kendriya Vidhyalaya at Khajuri Khas, Delhi
Detailed estimate of External Plumbing Services
S. No. Description
Amount (in Rs.)
1 EXTERNAL SEWERAGE AND STORM WATER DRAINAGE 3,329,520 1,211,078
2 EXTERNAL WATER SUPPLY 532,550 5,161
3 RAIN WATER HARVESTING PIT 911,857
MODIFIED ESTIMATED COST AFTER USING CORRECTION
FACTOR ON DSR 2023 ON ACCOUNT OF GST @0.973
GRAND TOTAL (DSR +NSR) ₹ 6,915,332.38
GRAND TOTAL (DSR +NSR) ₹ 6,915,332.38
Digitally signed by ARTI
Project Name:- Construction of Kendriya Vidhyalaya at Khajuri Khas, Delhi
Schedule Of Quantity
TOTAL DSR Rate (in DSR Amount (in MR Rate MR Amount
S. No. DSR 2023 Description Unit
QUANTITY Rs.) Rs.) (in Rs.) (in Rs.)
EXTERNAL SEWERAGE AND STORM
Excavating trenches of required width for
pipes, cables, etc including excavation for
sockets, and dressing of sides, ramming of
bottoms, depth upto 1.5 m, including getting
out the excavated soil, and then returning the
1.1 2.10.1 soil as required, in layers not exceeding 20 cm
in depth, including consolidating each
deposited layer by ramming, watering, etc. and
disposing of surplus excavated soil as directed,
within a lead of 50 m :
All kinds of soil
Pipes, cables etc. exceeding 80 mm dia. but
not exceeding 300 mm dia
Supplying and laying of following size DWC
SN8 pipe ISI marked along with all
accessories like socket, bend, couplers etc.
conforming to IS 16098, Part II complete with
1.2 MR-1 fitting and cutting,jointing etc.direct in ground
(75 cm below ground level) including
excavation and refilling the trench but
excluding sand cushioning and protective
covering etc., complete as required.
250 mm dia. Pipe Metre 220 1499.00 329780
Providing and laying cement concrete 1:5:10
(1 cement : 5 coarse sand : 10 graded stone
1.3 19.2 aggregate 40 mm nominal size) all-round
DWC pipes including bed concrete as per
standard design :
19.2.4 250 mm dia. DWC & RCC Pipe Metre 495 1590.55 787322.25
Derrived 300 mm dia. DWC & RCC Pipe Metre 258.5 1795 464007.5
Derrived 450 mm dia. DWC & RCC Pipe Metre 165 2099 346335
Providing and laying non-pressure NP2 class
(light duty) R.C.C.
pipes with collars jointed with stiff mixture of
cement mortar in the proportion of 1:2 (1
cement : 2 fine sand) including testing of
joints etc. complete :
Constructing brick masonry manhole in
cement mortar 1:4 ( 1cement : 4 coarse sand )
with R.C.C. top slab with 1:1.5:3 mix
(1cement : 1.5 coarse sand (zone-III) : 3
graded stone aggregate 20mm nominal size),
foundation concrete 1:4:8 mix (1 cement :
4coarse sand (zone-III) : 8 graded stone
aggregate 40 mm nominalsize), inside
plastering 12 mm thick with cement mortar
1:3 (1 cement: 3 coarse sand) finished with
floating coat of neat cement andmaking
channels in cement concrete 1:2:4 (1 cement :
2 coarse sand : 4 graded stone aggregate 20
mm nominal size) finished with a floating coat
of neat cement complete as per standard
Digitally signed by ARTI
TOTAL DSR Rate (in DSR Amount (in MR Rate MR Amount
S. No. DSR 2023 Description Unit
QUANTITY Rs.) Rs.) (in Rs.) (in Rs.)
Inside size 90x80 cm and 45 cm deep
including C.I. cover with frame (light duty)
455x610 mm internal dimensions, total weight
19.7.1.1 of cover and frame to be not less than 38 kg Each 100 12770.55 1277055
(weight of cover 23 kg and weight of frame 15
kg) : 19.7.1.1 With common burnt clay F.P.S.
(non modular) bricks of class designation 7.5
19.8 Extra for depth for manholes :
19.8.1 Size 90x80 cm
With common burnt clay F.P.S. (non modular)
bricks of class designation 7.5
Providing and fixing square-mouth S.W. gully
trap class SP-1 complete with C.I. grating
brick masonry chamber with water tight C.I.
1.10 19.4 cover with frame of 300 x300 mm size (inside)
the weight of cover to be not less than 4.50 kg
and frame to be not less than 2.70 kg as per
standard design :
19.4.2 150 x 100mm size P-type
With common burnt clay F.P.S. (non modular)
bricks of class designation 7.5
Making connection of drain or sewer line
with existing manhole
including breaking into and making good the
walls, floors with cement concrete 1:2:4 mix
(1 cement : 2 coarse sand : 4 graded stone
1.14 19.21 aggregate 20 mm nominal size) cement
plastered on both sides with cement mortar 1:3
(1 cement : 3 coarse sand), finished with a
floating coat of neat cement and making
necessary channels for the drain etc. complete
19.21.2 For pipes 250 to 300 mm diameter Each 2 922.4 1844.8
19.21.3 For pipes 350 to 450 mm diameter Each 2 1328.45 2656.9
TOTAL CARRIED TO SUMMARY 3329519.725 1211078
2 EXTERNAL WATER SUPPLY
Providing and fixing Chlorinated Polyvinyl
Chloride (CPVC) pipes, having thermal
stability for hot & cold water supply including
all CPVC plain & brass threaded fittings This
includes jointing of pipes & fittings with one
step CPVC solvent cement, trenching, refilling
& testing of joints complete as per direction of
Engineer in Charge.
18.9.3 25 mm nominal dia Pipe Metre 355.40
18.9.5 40 mm nominal dia Pipe Metre 563.05
18.9.6 50 mm nominal dia Pipe Metre 115 794.25 91338.75
18.9.7 65 mm nominal dia Pipe Metre 1674.40
18.9.8 80 mm nominal dia Pipe Metre 149.5 2166.35 323869.325
Providing and fixing in position garden
hydrant hose outlet consisting of 25mm ball
valve full bore type with lever and female
screwed ends, tested to 20 Kg/cm2 of approved
quality, including G.I. elbow, G.I. threaded
hose receiver etc. complete.
Digitally signed by ARTI
TOTAL DSR Rate (in DSR Amount (in MR Rate MR Amount
S. No. DSR 2023 Description Unit
QUANTITY Rs.) Rs.) (in Rs.) (in Rs.)
Providing and fixing enclosed type water
meter (bulk type) conforming to IS : 2373 and
2.3 18.60 tested by Municipal Board complete with
bolts, nuts, rubber insertions etc. (The tail
pieces if required will be paid separately) :
18.60..1 100 mm dia nominal bore Each 1 3627.65 3627.65
Constructing masonry Chamber 30x30x50
cm inside, in brick work in cement mortar 1:4
(1 cement :4 coarse sand) for stop cock, with
C. I. surface box 100x100 x75 mm (inside)
with hinged cover fixed in cement concrete
slab 1:2:4 mix (1 cement : 2 coarse sand : 4
graded stone aggregate 20 mm nominal size),
i/c necessary excavation, foundation concrete
1:5:10 ( 1 cement : 5 fine sand : 10 graded
stone aggregate 40mm nominal size ) and
inside plastering with cement mortar 1:3 (1
cement : 3 coarse sand) 12mm thick, finished
with a floating coat of neat cement complete
as per standard design :
With common burnt clay F.P.S.(non modular)
class designation 7.5
Constructing masonry Chamber 60x60x75
cm inside, in brick work in cement mortar 1:4
(1 cement : 4 coarse sand) for sluice valve,
with C.I. surface box 100mm top diameter,
160 mm bottom diameter and 180 mm deep (
inside) with chained lid and RCC top slab
1:2:4 mix (1 cement : 2 coarse sand : 4 graded
2.5 18.33 stone aggregate 20mm nominal size ) , i/c
necessary excavation, foundation concrete
1:5:10 (1 cement : 5 fine sand : 10 graded
stone aggregate 40 mm nominal size) and
inside plastering with cement mortar 1:3 (1
cement : 3 coarse sand) 12 mm thick, finished
with a floating coat of neat cement
complete as per standard design :
With common burnt clay F.P.S.(non modular)
class designation 7.5
Constructing masonry Chamber 60x45x50
cm inside, in brick work in cement mortar 1:4
(1 cement : 4 coarse sand) for water meter
complete with C.I. double flap surface box
400x200x200 mm (inside) with locking
arrangement and RCC top slab 1:2:4 mix (1
cement : 2 coarse sand : 4 graded stone
2.6 18.37 aggregate 20 mm nominal size) , i/c necessary
excavation, foundation concrete 1:5:10 ( 1
cement : 5 fine sand:10 graded stone aggregate
40 mm nominal size) and inside plastering
with cement mortar 1:3 (1 cement : 3 coarse
sand) 12 mm thick, finished with a floating
coat of neat cement complete as
per standard design :
With common burnt clay F.P.S.(non modular)
class designation 7.5
TOTAL CARRIED TO SUMMARY 532549.615 5161.2
3 RAIN WATER HARVESTING PIT
Digitally signed by ARTI
TOTAL DSR Rate (in DSR Amount (in MR Rate MR Amount
S. No. DSR 2023 Description Unit
QUANTITY Rs.) Rs.) (in Rs.) (in Rs.)
Boring/ drilling bore well of required dia for
casing/ strainer pipe, by suitable method
prescribed in IS: 2800(part 1), including
collecting samples from different strata,
preparing and submitting strata chart/ bore
log, including hire and running charges of all
equipment tools plants and machineries
required for the job, all complete as per
direction of Engineer-in-charge upto 90 m
depth below ground level.
23.1.2 Rockey Strata including Boulders
Supplying, assembling, lowering and fixing in
vertical position in bore well, unplasticized
PVC medium well casing (CM) pipe of
3.2 23.3 required dia, conforming to IS: 12818,
including required hire and labour charges,
fittings and accessories etc all complete for all
depths as per direction of Engineer-in-charge.
23.3.1 100 mm nominal size dia. Metre 200 672.3 134460
Supplying, assembling, lowering and fixing in
vertical position in bore well, unplasticized
PVC medium well screen (RMS) pipe with
3.3 23.4 ribs, conforming to IS: 12818, including hire
and labour charges, fittings and accessories etc
all complete for all depths as per direction of
Engineer-in-charge
23.4.1 100 mm nominal size dia. Metre 200 686.55 137310
Supplying , filling , spreading and levelling
stone boulders of size range 5 cm to 20 cm , in
3.4 23.5 recharge pit in the required thickness for all Cum 20 1509.8 30196
leads and lifts all complete as per direction of
engineer - in - charge .
Supplying , filling , spreading and levelling
stone boulders of size range 5 mm to 10 mm ,
in the recharge pit over the existing layers of
boulders in required thickness for all lead and
lifts all complete as per direction of engineer -
Supplying , filling , spreading and levelling
coarse sand of size range 1.5 mm to 2 mm , in
3.6 23.7 the recharge pit in required thickness over Cum 20 1538.25 30765
gravel layer for all leads and lifts all complete
as per direction of engineer - in - charge .
Gravel packing in tube well construction in
accordance with IS: 4097, including providing
gravel fine/medium/coarse in required grading
and sizes as per actual requirement all
complete as per direction of Engineerin-
Digitally signed by ARTI
TOTAL DSR Rate (in DSR Amount (in MR Rate MR Amount
S. No. DSR 2023 Description Unit
QUANTITY Rs.) Rs.) (in Rs.) (in Rs.)
Development to tube well in accordance with
IS: 2800(part 1) and IS:11189 to establish
maximum rate of usable water yield without
sand content ( beyond permissible limit) with
required capacity air compressor, running the
compressor for required time till well is fully
developed measuring yield of well by “V”
notch method or any other approved method,
3.8 23.12 measuring static level & draw down etc. by Hour 42 1085.05 45572.1
step draw down method collecting water
samples & getting tested in approved
laboratory, i/c disinfection of tube well, all
complete including required hire & labour
charges of air compressor tools & accessories,
etc. all, as per direction of engineer - in -
Providing and fixing suitable size threaded
mild steel cap or spot welded plate to the top
of bore well housing/ casing pipe removable as
per requirement all complete for bore well of :
Providing and fixing M.S clamp of required
dia to the top of casing/ housing pipe of tube
3.10 23.14 well as per IS:2800 (part 1), including
necessary bolts & nuts of required size
Providing and fixing Bail plug/ Bottom plug
3.11 23.15 of required dia to the bottom of pipe assembly
of tube well as per IS: 2800 (part 1)
TOTAL CARRIED TO SUMMARY 911857.1
4 BOREWELL (1 Nos.)
Boring/drilling bore well of required dia for
casing/ strainer pipe, by suitable method
prescribed in IS: 2800 (part I), including
collecting samples from different strata,
preparing and submitting strata chart/ bore
4.1 23.2 log, including hire & running charges of all
equipments, tools, plants & machineries
required for the job, all complete as per
direction of Engineer -in-charge, beyond 90
metre & upto 150 metre depth below ground
23.1 All Types of Soil
23.2 Rocky strata including boulders
Supplying, assembling, lowering and fixing in
vertical position in bore well, ERW (Electric
Resistance Welded) FE 410 mild steel screwed
and socketed/plain ended casing pipes of
required dia, conforming to IS: 4270, of
reputed & approved make, including painted
with outside surface with two coats of
anticorrosive paint of approved brand and
manufacture, including required hire & labour
charges, fittings & accessories, all complete,
for all depths, as per direction
of Engineer-in-charge.
Digitally signed by ARTI
TOTAL DSR Rate (in DSR Amount (in MR Rate MR Amount
S. No. DSR 2023 Description Unit
QUANTITY Rs.) Rs.) (in Rs.) (in Rs.)
200 mm nominal size dia having minimum
23.10.3 wall thickness Metre 95 2,442.75 232,061.25
Supplying, assembling, lowering and fixing in
vertical position in bore well, ERW (Electric
Resistance Welded) FE 410 plain slotted
(having slot of size 1.6/3.2 mm) mild steel
threaded and socketed/ plain bevel ended pipe
(type A) of required dia, conforming to IS:
8110, of reputed and approved make, having
wall thickness not less than 5.40 mm,
including painted with outside surface with
two coats of anticorrosive bitumestic paint of
approved brand and manufacture,
including hire & labour charges, fittings &
accessories, all complete, for all depths, as per
direction of Engineer -in-charge.
23.11.3 200 mm nominal size dia Metre 60 2,571.05 154,263.00
Supplying, filling, spreading & leveling stone
boulders of size range 5 cm to 20 cm, in
4.4 23.5 recharge pit, in the required thickness, for all cum 5 1,509.80 7,549.00
leads & lifts, all complete as per direction of
Engineer-in-charge.
Supplying, filling, spreading & leveling
gravels of size range 5 mm to 10 mm, in the
recharge pit, over the existing layer of
boulders, in required thickness, for all leads &
lifts, all complete as per direction of Engineer-
Supplying, filling, spreading & leveling coarse
sand of size range 1.5 mm to 2 mm in recharge
4.6 23.7 pit, in required thickness over gravel layer, for cum 5 1,538.25 7,691.25
all leads & lifts, all complete as per direction
of Engineer -in-charge.
Gravel packing in tubewell construction in
accordance with IS: 4097, including providing
gravel fine/ medium/ coarse, in required
grading & sizes as per actual requirement, all
complete as per direction of Engineer-in-
Development of tube well in accordance with
IS : 2800 (part I) and IS: 11189, to establish
maximum rate of usable water yield without
sand content (beyond permissible limit), with
required capacity air compressor, running the
compressor for required time till well is fully
developed, measuring yield of well by "V"
notch method or any other approved method,
measuring static level & draw down etc. by
step draw down method, collecting water
samples & getting tested in approved
laboratory, i/c disinfection of tubewell, all
complete, including hire & labour charges of
air compressor, tools & accessories etc., all as
per requirement and direction of Engineer-in-
Providing and fixing suitable size threaded
mild steel cap or spot welded plate to the top
4.9 23.13 of bore well housing/ casing pipe, removable
as per requirement, all complete for borewell
Digitally signed by ARTI
TOTAL DSR Rate (in DSR Amount (in MR Rate MR Amount
S. No. DSR 2023 Description Unit
QUANTITY Rs.) Rs.) (in Rs.) (in Rs.)
Providing and fixing M.S. clamp of required
dia to the top of casing/ housing pipe of
4.10 23.14 tubewell as per IS: 2800 (part I), including
necessary bolts & nuts of required size
Providing and fixing Bail plug/ Bottom plug
4.11 23.15 of required dia to the bottom of pipe assembly
of tubewell as per IS:2800 (part I).
Supply, installation testing & commissioning
of submersible pumping set complete in ss
suitable to operate on 410 volts 3 phase 50 HZ
A.C. power supply, Motor efficiency IE 3
4.12 MR-3 including water proof joint free flat
submersible cooper cable,of 6 sqmm including
earthing connection motor control panel
complete in all respect as per details given
below : (For Borewell)(1NOS)
Discharge 300 LPM.
TOTAL CARRIED TO SUMMARY (1Nos) 674,318.35 397,951.00
Digitally signed by ARTI
PROJECT- CONSTRUCTION KENDRIYA VIDHYALYA AT KHAJURI KHAS, DELHI
SUMMARY FOR INTERNAL FIRE FIGHTING SYSTEM
SN DESCRIPTION OF ITEMS
DSR E&M 2025 MR
1 INTERNAL FIRE FIGHTING SYSTEM 2175318.60 1318051.00
TOTAL OF DSR + NON DSR ITEM 3493369.60
SAY TOTAL 3493370.00
PROJECT- CONSTRUCTION KENDRIYA VIDHYALYA AT KHAJURI KHAS, DELHI
PACKAGE - INTERNAL FIRE FIGHTING SYSTEM SCHEDULE OF QUANTITIES
S.No UNIT QTY RATE AMOUNT
Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip
earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer
1.00 5.9 etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt Metre 30 160.00 4800.00
& spring washer spaced at 50mm)
Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as
Supplying and installing following size of perforated painted with powder coating M.S.
cable trays with perforation not more than 17.5%, in convenient sections, joined with
3.00 4.1 connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts,
painting suspenders etc as required.
a) 4.1.2 150mm width x 50mm depth x 1.6 mm thickness. Metre 30 686.00 20580.00
Providing and fixing in position the industrial type pressure gauges with gun metal /
brass valves complete as required
(A) Supplying, installation, testing and commissioning of electric driven terrace pump
5.00 27.4 with Electrical Panel suitable for automatic operation and consisting of following,
complete in all respects, as required: (Terrace Pump)
(B) Horizontal type, multistage, centrifugal, split casing pump of cast iron body &
bronze impeller with stainless steel shaft, mechanical confirming to IS : 1520
(C) Suitable HP squirell cage induction motor TEFC type suitable for operation on 415
volts, 3 phase, 50 Hz, AC supply with IP55 class of protection for enclosure, horiziontal
foot mounted type with Class-'F' insulation, conforming to IS-325.
(D) M.S.fabricated common base plate, coupling, coupling guard, foundation bolts
etc.as required.
(E ) Suitable cement concrete foundation duly plastered and with anti vibration pads.
Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe
conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees,
flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with
6.00 27.7 suitable clamp/support frame and painting with two or more coats of synthetic
enamel paint of required shade complete as required :
Supplying and fixing single headed internal hydrant valve with instantaneous
Gunmetal/Stainless Steel coupling of 63 mm dia with cast iron wheel ISI marked
7.00 27.9 conforming to IS 5290 (Type -A) with blank Gunmetal/Stainless Steel cap
and chain as required :
a) 27.9.2 Single headed Stainless steel Each 19 6632.00 126008.00
Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with
8.00 27.11 bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets
conforming to IS 13095 of following sizes as required :
Providing, installation, testing and commissioning of non-return valve of
9.00 27.14 following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts,
nuts, washers etc.as required :
Providing, installation, testing and commissioning of stainless steel Y-strainer
10.00 27.15 fabricated out of 1.6 mm thick stainless steel, Grade 304, sheet with 3 mm dia
holes with stainless steel flange.
Supplying and fixing 63 mm dia, 15 m long RRL hose pipe with 63 mm dia male
11.00 27.16 and female couplings duly bound with GI wire, rivets etc. conforming to IS 636 Each
(type-A) as required :
a) 27.16.2 Stainless Steel (Grade 304) Each 38 4667.00 177346.00
Supplying and fixing first-aid Hose Reel with MS construction spray painted
12.00 27.17 in post office red, conforming to IS 884 complete with the following as Each
Digitally signed by ARTI
PROJECT- CONSTRUCTION KENDRIYA VIDHYALYA AT KHAJURI KHAS, DELHI
PACKAGE - INTERNAL FIRE FIGHTING SYSTEM SCHEDULE OF QUANTITIES
S.No UNIT QTY RATE AMOUNT
20 mm nominal internal dia water hose thermoplastic (Textile reinforced) type -2
as per IS: 12585
20 mm nominal internal dia gun metal globe valve & nozzle.
Drum and brackets for fixing the equipmets on wall.
Connections from riser with 25 mm dia stop gun metal valve & M.S. Pipe and socket.
Supplying & fixing 63 mm dia gun metal short branch pipe with 20 mm nominal
internal diameter size nozzle conforming to IS 903 suitable for instantaneous
13.00 27.18 connection to interconnect hose pipe coupling as required :
a) 27.18.2 Stainless Steel (Grade 304) Each 19 3402.00 64638.00
Supplying and fixing of fire brigade connection of cast iron body with gun metal
14.00 27.19 male instantaneous inlet couplings complete with cap and chain as reqd. for
suitable dia MS pipe connection conforming to IS 904 as required :
Supplying and fixing air vessel made of 250 mm dia, 8 mm thick MS sheet, 1200 mm
in height with air release valve on top and flanged connection to riser, drain
15.00 27.20 arrangement with 25 mm dia gun metal wheel valve with required accessories, Set 4 19402.00 77608.00
pressure gauge and painting with synthetic enamel paint of approved shade as
Providing & fixing of pressure switch in M.S. pipe line including connection etc. as
Providing and fixing gun metal gate valve with C.I. wheel of approved quality
17.00 (screwed end) :
a) 18.17.1 25 mm nominal bore Each 19 622.40 11825.60
TOTAL OF DSR ITEM 2175319
Providing and fixing angle iron (40mmx40mmx5mm) door frame and MS sheet (6mm
thick) cum glass shutter of size 2.1mtrx0.9mtr(N.S.) with 25mmx25mmx3mm angle
frame all around and stiffened in between i/c hinges, handle, locking arrangement,
MR-1/DSR painting with approved synthetic enamel paint i/c sign writing on glass at internal
BASED hydrant including providing & fixing S.S. sheet 2mm thick on remaining portion above
door to close opening i/c painting etc. as required. Glass shall be 6 mm thick.
Providing and fixing stainless steel standard fireman's axe with heavy insulated
19.00 MR-2 rubber handle tested to 20000 volts as per IS : 926 complete. Each 19 2943.00 55917.00
Providing and fixing reinforced neoprene rubber vibration eliminators / expansion
20.00 MR-3 joints (to provide relief from stresses at pipe flanges) suitable for upto 20 kg/cm2
pressure, complete as per specification.
Providing and fixing heavy duty copper armored cables 1.1 KVA grade including
21.00 MR-4 necessary support clamps at ceiling level and connection legs complete in all
a) Power cable 3 core 16 Sq.mm Metre 30 1976.00 59280.00
Supply, installation, testing and commissioning ISI marked (IS:15683) Fire
Extinguisher, Carbon-di-oxide type capacity 4.5 Kg. Flat base including valve,
22.00 MR-5 discharge hose of not less than 10 mm dia, 1M long and complete in all respects Each 39 18256.00 711984.00
including initial fill with CO2 gas conforming to IS:307-1966 and walll suspension
braket as required as per specifications.
Supply, installation, testing and commissioning of 6kg ABC (Powder Type) Fire
Extinguisher. Mild Steel Cylinders ISI marked fitted with pressure indicating gauge,
internal tube, squeeze lever type valve fully charged with ABC 90 powder (Mono
23.00 MR-6 Ammonium Phosphate) pressured by Nitrogen complete in all respects including wall Each 39 5777.00 225303.00
suspension bracket and conforming to IS:15683 as required as per specifications.
Digitally signed by ARTI
PROJECT- CONSTRUCTION KENDRIYA VIDHYALYA AT KHAJURI KHAS, DELHI
PACKAGE - INTERNAL FIRE FIGHTING SYSTEM SCHEDULE OF QUANTITIES
S.No UNIT QTY RATE AMOUNT
Providing, fixing, testing and commissioning of control panel for Terrace Booster
Incoming: MCCB 125A 1 set of Phase indicating lamps, 1 set of 125A Al bus bars,
24.00 MR-7 3No Ammeter, 3No Voltmeter with phase selector switch Feeder for Booster Pumps - 2 Each 1 59878.00 59878.00
No. 2 No. 50A TP MCCB without releases. DOL starter with over load relay, single
phase preventor and indicating lamps with ON/OFF push buttons. 2 No. Automanual
selector switch. Suitable for booster pumps
TOTAL OF NON DSR ITEM 1318051.00
Digitally signed by ARTI
Project Name:- Construction of Kendriya Vidhyalaya at Khajuri Khas, Delhi
INTERNAL ELECTRICAL WORKS (AS PER DSR 2025)
S.NO NAME OF SUB-HEAD
DSR 2025 items Non Scheduled items
1 SUBHEAD- I: DISTRIBUTION BOARD 413498.00 0.00
2 SUB-HEAD - II : INTERNAL WIRING 6391542.80 30960.00
3 SUB-HEAD III - FANS & LIGHT FIXTURES: 1079420.00 804098.00
4 SUB HEAD - IV : LIGHTNING PROTECTION SYSTEM 173522.00 137100.00
5 SUB HEAD - V: LIFT 1684225.72 0.00
6 SUB HEAD - VI: UPS 337012.00 0.00
7 SUB HEAD-VII: ADVANCED VENTILATION & DISINFECTION SYSTEM 0.00 2640000.00
8 SUB HEAD-VIII:FIRE ALARM & CCTV SYSTEM 1016134.00 1234889.00
Project Name:- Construction of Kendriya Vidhyalaya at Khajuri Khas, Delhi
SCHEDULE OF QUANTITIES FOR SUPPLY, ERECTION, TESTING AND COMMISSIONING
INTERNAL ELECTRICAL WORKS (AS PER DSR 2025)
AS PER DSR-2025 AS PER MARKET RATE
S.NO DSR ITEMS DESCRIPTION OF ITEM UNIT
QUANTITY RATE (RS.) AMOUNT (RS.) RATE (RS.) AMOUNT (RS.)
1 SUBHEAD- I: DISTRIBUTION BOARD
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/
1 2.3 recess complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted
including earthing etc. as required. (But without MCB/RCCB/Isolator)
a) 2.3.1 6 way, Double door Each 0.00 2,390.00 0.00
c) 2.3.3 12 way, Double door Each 0.00 2,871.00 0.00
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415
2 2.4 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections,
powder painted including earthing etc. as required. (But without MCB/RCCB/ Isolator)
Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with
connections, testing and commissioning etc. as required.
Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with
connections, testing and commissioning etc. as required.
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for
6 2.10 inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc.
Supplying and fixing following rating, double pole, single phase and neutral, 240 volts, residual current circuit breaker
7 2.14 ( RCCB), having a sensitivity current upto 30 milliamperes in the existing MCB DB complete with connections,
testing and commissioning etc as required.
Supplying and fixing following rating, four pole, three phase and neutral, 415 volts, residual current circuit breaker (
8 2.15 RCCB), having a sensitivity current upto 30 milliamperes in the existing MCB DB complete with connections, testing
and commissioning etc as required.
Total carried over to Summary 413,498.00 0.00
SUB-HEAD - II : INTERNAL WIRING
Digitally signed by ARTI
1 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR PVC insulate copper
conductor single core cable in surface/ recessed medium class PVC conduit, with modular switch, modular plate,
suitable GI box and earthing the point with 1.5 sq.mm FRLS/HFFR PVC insulated
copper conductor single core cable etc. as required.
Wiring for group controlled (looped) light point/f point/exhaust fan point/ call bell point ( without independent switch
etc.) with 1.5 sq. mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/ recessed PVC
conduit, and earthing the point with 1.5 sq. mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as
3 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper
conductor, single core cable in surface/ recessed medium class PVC conduit as required
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including
4 1.31 providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. Each 294.00 545.00 160,230.00
(For light plugs to be used in residential buildings).
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including
5 1.32 providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. Each 186.00 659.00 122,574.00
Supplying and fixing 20 amps, 240 volts, SPN industrial type, socket outlet, with 2 pole and earth, metal enclosed
6 2.18 plug top along with 20 amps "C" curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal Each 19.00 1,806.00 34,314.00
cover for the socket out let and complete with connections, testing and commissioning etc. as required.
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including
providing and fixing 32 amps modular socket outlet and 32 amps modular switch, connection etc. as required.
Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/
7 1.12 recessed medium class PVC conduit alongwith 1 No 4 sq. mm FRLS PVC insulated copper conductor single core Metre 1640.00 373 611,720.00
cable for loop earthing as required.Make:KEI,Worldcab,RR Kable,Bonton
Wiring for light/ power plug with 4X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/
8 1.13 recessed medium class PVC conduit alongwith 2 Nos 4 sq. mm FRLS PVC insulated copper conductor single core Metre 820.00 587 481,340.00
cable for loop earthing as required.Make:KEI,Worldcab,RR Kable,Bonton
9 1.38 Supplying and fixing of call bell / buzzer suitable for single phase,230 volt complete as required. Each 7.00 112.00 784.00
3 SUB-HEAD III - FANS & LIGHT FIXTURES:
DSR2025-1.2 LED Down lighter (SMD Type) (System lumen efficacy ≥120 <135 lm/Watt )
Digitally signed by ARTI
Supplying, installation, Testing & Commissioning of LED Recessed /
surface Down lighter (Round / square/ Rectangular) SMD type of following
body material with PMMA and prismatic diffuser and construction as per IS :
10322 with driver as per the requirement with Driver efficiency >85%,
Operating voltage AC 140-270 Volt, freq 50/60 hz, Operating temp range
-15 deg to 40 deg centigrade, internal surge protection of 2.5 KV with
Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80 ,
UGR (Unified Glare Rating) < 19, Flicker free (flicker should
be below 5 %), life time (LED,Driver & electrical circuitry), life time of
minimum 50000 Burning Hours with , 70% of initial Lumen maintained
till life ends , CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per
ANSI Bin), SDCM(Standard Deviation Color Matching) <3, Maximum
power consumption should not more than the specified rating and Fixture
shall be of relevant BIS standard and trade mark certificate ( T.C.).
Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on
housing. OEM must have its own in house NABL lab setup for all
testing facilities for LED fixtures. "complete in all respect i/c
connections with 1.5 sq mm FRLS, PVC insulated copper conductor
single core cable and earthing etc. as required with Minimum 5 year OEM
warranty. System lumen efficacy ≥120 <135 lm/Watt output . LM79 & LM80
Test report from NABL lab for all testing required for LED fixtures as
per BIS shall be submitted. Shape size and CCT shall be as approved by
Engineer-in-Charge as per requirement. (Thermal management: heat sink
of aluminum housing such that LED junction temperature shall not rise
Powder coated die cast /Extruded aluminum Body including trim .
Supply installation testing and comissioning 4ft LED (Light Emitting Diode) tube light system power: 20W, luminous
3 NDSR-1.3 flux of luminaire 2000lm or more, colour temperature of min 5700K , CRI>80, 230V constant current driver, Each 567.00 1,142.00 647,514.00
luminaire profile powder coated in white. Protection class I, L = 1175 mm (min),
Supply installation testing and comissioning LED Tube, Wall / Surface / Celling Mounted, 10W(MIRROR LIGHT),
luminous flux of luminaire 900lm, IP 20,1200mm, Direct light emission, 230V, Electronic Control Gear, 5700K, Satin
Diffuser, L=600mm (Min)
Digitally signed by ARTI
Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less
Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle
kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CM/M/W) minimum 6.00, Air
5 DSR-19.1 delivery minimum 210 Cum/Min , 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or Each 266.40 2730 727,272.00
electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers,
temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single
phase AC Supply, earthing etc. complete as r
Supply, Installation, Testing & Commissioning of LED bulkhead with LED (Light Emitting Diode) system power:
10W, luminous flux of luminaire 800lm, 5700K, cool white, CRI 80, 230V, Direct light emission, white housing, opal
diffuser, integral electronic control gear, Protection class I, IP65, IK08, L=215mm, B=132mm, H=55mm
8 NDSR-1.8 Supply, Installation, Testing & Commissioning of 15W LED WALL BRACKET LIGHT Each 2.00 1,713.00 3,426.00
10 NDSR-1.10 Supply, Installation, Testing & Commissioning of exhaust fan Each 23.00 2,595.00 59,685.00
Total carried over to Summary 1079420.00 804,098.00
4 SUB HEAD - IV : LIGHTNING PROTECTION SYSTEM
1 Providing and fixing of lightning conductor finial, made of 25mm dia 300mm long, copper tube, having single prong
6.1 at top, with 85mm dia 6 mm thick copper base plate including holes etc. complete as required. Each 20.00 609.00 12,180.00
2 Jointing copper / G.I. tape (with another copper/ G I tape, base of the finial or any other metallic object) by riveting /
6.3 nut bolting/ sweating and soldering etc as required. Each 18.00 139.00 2,502.00
3 Providing and fixing GI tape 20mm x 3mm thick on parapet or surface of wall for lightning conductor as required.
(for horizontal run).
4 Providing and fixing G.I. tape 20mm x 3mm thick on parapet or surface of wall for lightning conductor as required.
(For vertical run.)
5 Providing and fixing testing joint, made of 20mm x 3mm thick G.I. strip, 125mm long with 4 Nos. of G.I. bolts, nuts,
check nuts and spring washers etc. complete as required.
6 6.11 Providing and laying G.I. tape, 32mm x 6mm thick, from earth electrode directly in ground as required. Metre 200.00 221.00 44,200.00
7 Earthing with G.I. earth pipe 4.5 metre long, 40mm dia including accessories, and providing masonry enclosure with
cover plate having locking arrangement etc. with charcoal or coke and salt complete as required.
Total carried over to Summary 173522 137100
5 SUB HEAD - V: LIFT
Digitally signed by ARTI
DSR- 2025, 21.1 Supplying, Installation, Testing & Commissioning of following capacity passenger Machine room less MRL) lift with
regenerative drive as per CPWD General Specification for Electrical Works (Part-III Lift & Escalator) 2003, BIS
Codes, NBC 2016 as amended upto date having provision for barrier free access as per Harmonised Guidelines &
Standards for Universal Accessibility in India - 2021 of MoHUA, serving different floors in the lift shaft as per
detailed specifications enclosed and as under including all other equipment and accessories complete as
Design of lifts:- Passengers Type
Capacity:-13Passengers
Door Operation - Full Height Infra-red cross-multi beam
Floor -5 (G+4) = 5stops
Travel - 17 Meters (approx
Stop & Opening - 5 Stops & 5 Openings
Controller: A.C. variable voltage & variable
Automatic rescue device (ARD) complete with dry
maintenance free batteries as required.
Operation: Microprocessor based single automatic push button/simplex selective collective/duplex collective selective
with/without attendant
Power-415 Volts+10%, 3 phase, 50 Hz, 4 wires system
Car Enclosure: Stainless steel scratch proof (Moon Rock/Honeycomb/ Hairline Finish) on all sides and stainless steel
decorative ceiling with fans (indirct throw) and LED fitting.
The car flooring should be smooth and antiskid as approved by engineer-in-charge
Car: Power operated, centre opening horizontal sliding stainless steel scratch proof (Moon Rock/Honeycomb/ Hairline
Closed loop Control System, protection against power fluctuation, self diagnostic control, Landing doors 2 hours Fire
rated, Overload detection and protection, Overspeed Governer, Dot Matrix LED D &
P Indicators In Car & Landings, BMS Compatibility, tamper proof infrared curtain covering almost the entire height
of the lift car door, Alarm horn, Anti Nuisance Operation, CCTV camera system with 4 MP IP camera, suitable NVR
and HDD for 30 days storage backup , Firemen switch, 2/3 way intercom, Emergency Stop Switch with battery
backup for fanand light fitting for 1 hour, pit ladder.
The lift doors shall have a vision panel to enable persons with hearing impairment to signal for help or assistance in
the event of an emergency.
An appropriate technological support be provided
emergency messaging |services or alarms etc.) to respond to the emergency requirements of person with hearing
impairment or deafness.
In case of failure of ARD or other electronic devices, a provision of manual rescue be provided
Total carried over to Summary 1684226 0
SUB HEAD - VI: UPS
Digitally signed by ARTI
DSR-26.1 Online UPS - Input supply: Single Phase, OutputSupply: Single Phase.
Supplying, installation, Testing & Commissioning of following capacity at full load (Unity Power Factor) ON LINE
Uninterrupted Power Supply (UPS) system suitable for Single Phase input, Single Phase output AC Supply. The UPS
shall include a Rectifier, inverter, battery bank suitable for 30 minutes back up (Battery VAH capacity shall not be less
than 1600 VAH per KVA of UPS rating per Hour backup time) on full load (Battery shall be VRLA, SMF in ABS
Container) and Static Bypass switch along with provision for manual bypass, suitable isolation transformer for
additional protection against neutral faults etc. The UPS systems shall be Microprocessor based Digital Control, using
Insulated Gate Bipolar Transistor (IGBT)'s both for the rectifier & inverter with PWM (Pulse Width Modulation)
Technology. The quality of design,manufacturing and inspection process should confirm to the relevant Inter-national
standards such as IEC/EN/VDE. The operating efficiency of the UPS systems shall be >95% at 100% non-linear
loads. Current total harmonic distortion(ITHD)/ total demand distortion (TDD) on the input grid shall be < 5% at 100
%load. (The required LC filters shall be included in UPS cost), extreme power factor kit to be include to limit the
input pf to 0.99 and output power factor shall be unity (i.e. kw rating of the UPS shall be kva rating x 1 ) however
UPS shall be suitable to take load at 0.7 laging to 0.7 leading power factor loads. UPS shall be suitable for incoming
supply AC single phase 160-270V 50 Hz and delivering output AC supply true sine wave single phase 220/230/240
Volt, 50 Hz +/- 0.2Hz, Overload capacity of 120% for 10 mins and 150% for 1 minute. Operating temperature 0 to 40
0C, Relative humidity 0-95% non condensing, noise level less than 60db at 1 meter distance, Protection for Under
voltage, over voltage, abnormal output voltage, battery over charging, output over current, short circuit, battery deep
discharge , 10 KV surge. Display for watt/VA,Amp and Voltage powerparameters etc. UPS shall comply with low
voltage electromagnetic compatibility (EMC) achieved as per EN 6204, EN6204 Part I and Part 2, it shall be a Voltage
and Frequency Independent (VFI) type UPS (as per standard IEC 62040-1, 2 & 3) . The UPS should be with IGBT
Based Inverter Technology,
Communication RS232/ RS485/ SNMP port open protocol for BMS integration as per approved by Engineering in
charge. Required battery racks, DC breaker of suitable rating and interconnecting copper conductor cable of suitable
size and connectors and all required accessories are inclusive in the cost. The UPS should have QR code which should
contain drawing, test report OEM manual, Geo- Tag of manufacturing location etc
Total of Sub-Head - VI 337,012.00 0.00
SUB HEAD-VII: ADVANCED VENTILATION & DISINFECTION SYSTEM
Supply, installation, testing & commissioning of centralised treated fresh air ceiling suspended unit the system should
NS-3 have a Pre filter + HEPA filter + Active carbon filter and Plasma ionization for purifying the intake air which would
restrict the infiltration of PM2.5 through CTFA.
Smart CTFA shall be a cloud-connected Treated Fresh Air Unit with intelligent PM2.5 and dew point-based control,
enabling optimized indoor air quality, remote monitoring, configuration, and analytics through a web platform.
Fresh air outlet design must be in between 150 to 250 mm
CTFA shall be complete with 1-1.5 meters wire & 6A top plug
Digitally signed by ARTI
Plasma ionization for CTFA will help in reducing viruses/bacteria, microbial load, Odors, TVOCs, and Ultrafine
particles present in space carrying the following certifications-UL 2998 (for zero ozone emission) , UL 2043 (for Fire
and Smoke Safety), ISO 16000, CSA C22.2# 187.
Intelligreen/ Airultra / Ecogreen Engineers
Total of Sub-Head VII 2,640,000.00
SUB HEAD-VIII:FIRE ALARM & CCTV SYSTEM
Supplying, installation, testing and commissioning of micro processor based intelligent addressable main fire alarm panel, central
processing unit with the following loop modules and capable of supporting not less than 240 devices (including detectors) and
minimum 120 detectors per loop and loop length up to 2 km, network communication card, minimum 320 character graphics/
LCD display with touch screen or other keypad and minimum 4000 events history log in the non volatile memory (EPROM),
28.2 power supply unit (230 ± 5% V, 50 hz), 48 hrs back-up with 24 volt sealed maintenance free batteries with automatic charger.
The panel shall have facility to connect printer to printout log and facility to have seamless integration with analog/digital voice
evacuation system (which is part of the schedule of work under SH: PA System) and shall be complete with all accessories . The
panel shall be compatible for IBMS system with open protocol BACnet/ Modbus over IP complete as per specifications
Supplying, installation, testing & commissioning of intelligent analog addressable photothermal detector complete with
mounting base complete as required.
Supplying, installation, testing & commissioning of response indicator on surface/recessed MS Box having two LED,
metallic cover complete with all connections etc as required.
Supplying, installation, testing & commissioning sector panel suitable for following zones, complete with visual
28.1.9.1 indications for short circuit fault, open circuit fault, fire condition and all other standard facilities as per IS:2189 with No. 1.00 9,808.00 9808.00
mimic diagram for all area/zone covered, complete with all connections, interconnections as required.
28.2.14 Supplying, installation, testing & commissioning of addressable manual call point complete as required. No. 3.00 4,063.00 12189.00
28.2.15 Supplying, installation, testing & commissioning of addressable horn cum strobe complete as required. No. 3.00 3,682.00 11046.00
Supplying & laying of 2x1.5 sqmm fire survival armoured cable, 600/1000V rated with annealed copper conductor
having glass mica fire barrier tape covered by an extruded
layer of Cross Linkable Ethylene Propylene Rubber (EPR) insulation and LSZH inner bedding, steel wire armouring
& LSZH outer sheath complete as required.
4MP @ 25/30fps@1440P (2560 x 1440) Dome Camera with 2.8/ 3.6/ 6/8/12 mm fixed lens (as per site requirement).
4MP @ 25/30fps@1440P (2560 x 1440) Outdoor Bullet Camera with 2.8/ 3.6/6/8/12 mm fixed lens (as per site
Digitally signed by ARTI
Unmanaged Network Switches (24 port) Minimum 4/8 nos. 10/100/1000 BASE-T Ethernet Ports. Uplink port should
have sufficient speed to avoid network congestion, preferably network should not be
NS-4 loaded more than 70% at any stage, fully IEEE 802.3 compliant,Protocols and compliances , The switch should 2.00 22,313.00 44,626.00
provide all standard protocols and compliances AND Mounting Shall Be Rackmount, wall or desktop mounting
1 Mtr Cat 6 patch cord with 23 AWG suitable for Gigabit connection, it should be suitable to maintain the bending
radius as per relevant code.
Supplying, Installation,Testing & Commissioning of 40 " LED Full HD TV Resolution 1920 x 1080 ,Contrast Ratio
(Typical) 5000:1,Built-in Speaker (10W + 10W), Magic Clone (to USB), Auto Source Switching & Recovery, Lamp
Error Detection, Super Clear Coating, Temperature Sensor, Plug and Play (DDC2B), Pivot Display, Clock Battery,
NS-6 PIP/PBP, Video Wall (10x10), Image Rotation, Button Lock, HDCP Support, Smart Scheduling, Smart F/W update, 1.00 48,607.00 48,607.00
Built-In MagicInfo Premium-Swith Mounting Brackets as per Technical Specification complete in all respect.
Total of Sub-Head - VIII 1,016,134.00 1,234,889.00
Digitally signed by ARTI
Project Name:- Construction of Kendriya Vidhyalaya at Khajuri Khas, Delhi
EXTERNAL ELECTRICAL WORKS (AS PER DSR 2025)
S.NO NAME OF SUB-HEAD
DSR 2025 items Non Scheduled items
1 SUB HEAD -I SUBSTATION WORK 0.00 10267463.66
2 SUB-HEAD - II - DG SET WORK 777820.00 191527.21
3 SUB HEAD- III : EARTHING 538372.00 0.00
4 SUB HEAD-IV: CABLE & END TERMINATIONS 403921.00 1329118.35
5 SUB HEAD-V : EXTERNAL LIGHTING 184920.09 2502223.33
6 SUB HEAD-VI : ROOF TOP PHOTO VOLTAIC (SPV) SYSTEM 2714000.00 0.00
Project Name:- Construction of Kendriya Vidhyalaya at Khajuri Khas, Delhi
SCHEDULE OF QUANTITIES FOR SUPPLY, ERECTION, TESTING AND COMMISSIONING
EXTERNAL ELECTRICAL WORKS (AS PER DSR 2025)
FINAL AS PER MARKET RATE
S.NO DSR ITEMS DESCRIPTION OF ITEM UNIT QTY.
(RS.) AMOUNT (RS.) RATE (RS.) AMOUNT (RS.)
SUB HEAD -I SUBSTATION WORK
MR-01 HT Metering Panel (SEB's)
Supplying / Receiving, Installation, Testing and Commissioning of Powder coated, 14 SWG CRCA sheet
steel enclosed 11KV H.T. Metering Panel complete with the following:
1set of 11/ √3KV / 110/ √ 3 Volt, 100 VA burden & accuracy class 0.5, single phase construction, dry type cast
3 Nos. of dual core 50/5A, 15 VA burden, accuracy class CL 0.5, 33 KV cast resin CTs
One Set of Phase Indicating Lamps.
2 Sets of HRC fuses with fuse base (H.T. Fuse - 1A & LT fuse 2-6A).
2 Nos. indoor cable end box suitable for 3C x 240 sq.mm. 11 KV(E), aluminium conductor XLPE Ar. cable
(Incoming & Outgoing cable).
1 No. SEB approved digital Trivector meter with MDI in KVA of accuracy class - 0.5.(Accuracy class shall be as
per local board)
Note: The contractor shall get the Trivector meter, CTs' & PT tested by SEB and the charges for liasioning for the
same will be paid extra.
SITC Rate for Metering Panel as described above Set 1 308,139.77 308,139.77
MR -02 11 kV 2 POLE STRUCTURE
Supply,installation,testing and commissioning of two pole structure with required arrangement for terminating
11KV overhead conductor on one side and 11KV, 2R x 3 x 300 sq.mm. Al conductor XLPE cable on the other
side including providing triple pole ,mechanically operated mounted on insulators and steel frame with operating
mechanism worked from ground level,expulsion fuses of 11KV ,required rating along with 11KV 200 amp air
break isolator suitable for outdoor application ,earth switch, Metal oxide type Lightning arrester complete with all
fittings and discharge capacity 50 KA complete as required.
11 kV HT 'H' pole as per specification & as described above SET 1 220,099.84 220,099.84
MR -03 HT Panel Main Switchgear Room
Design, manufacture, supply, delivery including supervision during installation, testing and commssioning of 1
panel, 11KV HT VCB switch board with following accessories: type tested Indoor Air insulated 11KV up to
630A, 26.3kA / 40kA (3sec), 3 Phase, metal clad, horizontal draw out type Switchboard with vacuum circuit
a. One No. incoming panel equipped with following:-
630A, 11KV, VCB 25 KA, TP, totally enclosed, air insulated metal clad housing, cassette mounted horizontal
isolation, horizontal drawout type, motorised spring charged, manually operated, trip free, vaccum circuit breaker
(VCB) having double isolation features and control devices complete with mechanical with continous tripping &
closing, coil suitable for 24V DC, shunt trip coil, OFF/ON indicators, mechanical operation counter & provided
with following:
Spring charge / discharge mechanical OFF push buttons for emergency trip (test / service position limit switches
with 6 NO/6 NC breaker auxiliary contacts in service position and The cubicle shall be of LSC 2B (Loss of
Service Continuity) and PM (Partition Class) classes as defined by IEC standard 62271-200. And it shall
comprise three high voltage compartments and one LV cabinet
Digitally signed by ARTI
CT chamber with single wound single phase, dual core cast resin CT, 15VA burden with core-1 for metering (CL-
1) and core-2 for protection (CL-5P10) and of 110/5+5A ratio.
Wireless communication energy sensor that monitors and measures energy and power in real-time is required so
that can count on operational efficiency and uptime.
Microprocessor based relay, IDMT, Time delay with 3 elements for over current (50-200%) and 1 element for
earth fault protection(10-40%) .-1 Set
Antipumping relay & master trip relay- 1 Set
Digital Ammeter with selector switch.-1 Set
A set of breaker ON/OFF/Trip/DC control supply/ Spring Charged indication lamp. 1 Set
Emergency trip push button on front door 1 Set
Limit switches with 6 NO/ 6 NC breaker auxiliary contacts 1 Set
Control:- T-N-C (Trip, Neutral, Close) breaker control switch. 1 Set
Space heater with thermostat for moisture absorption. 1 Set
Suitable for connection to 2 Runs x 3 core x 240 sq.mm. Cross linked polythelene (XLPE) 11KV cables or as
called for. 1 Set
HT Danger Plate 1 Set
Hooter low intensity 24 Volt with acknowledge and reset push button 1 Set
6-window microprocessor based annunciation panel with audio and visual indicator.
Over current & earth fault - 2 windows
Master trip operated - 1 window
Spare - 3 windows
Surge Arrestor, 10KA, Class II 1 Set
Thermal monitoring shall be fitted on HV field cable/busbar connections,The monitoring shall be done by a
battery less sensor that communicates wirelessly using Zigbee Green Power protocol.
Incoming as described above.
630A, 11KV, 25 KA, 3 phase, air insulated Electrolytic grade copper bus bars
c.Feeder panel for, equipped with following :-
1 nos. 630A, VCB 11KV 25 KA, TP, Totally enclosed, air insulated, metal clad housing, cassette mounted
horizontal isolation, horizontal drawout type, motorised spring charged, manually operated, trip free,each vaccum
circuit breaker having double isolation features and control devices complete with mechanical with continous
tripping & closing, coil suitable for 24V DC, shunt trip coil OFF/ON indicators mechanical operation counter &
provided with each feeder following:
Spring charge / discharge mechanical OFF push buttons for emergency trip (shrouded) test / service position limit
switches with 6 NO / 6 NC breaker auxliary contacts in service position.The busbars shall be rated for continuous
current, at 40°C ambient temperature. Temperature rise shall be as per IEC 62271-200.
The bus bars shall be sleeved for full voltage. Sleeve shall be heat shrinkable BTPM type of Reychem / equivelent
make. No PVC sleeving in bus bar for 11KV is acceptable
CT chamber with Dual core, single phase, Single ratio cast resin CT, 15VA burden with core-1 for metering (CL-
.2S) ,core-2 for protection (CL-5P10)
Digital Ammeter with selector switch, shrouded terminals, square size.The busbars shall be located in a separate
metal clad chamber and shall be air insulated. Bus bars shall be extendible on either side
Microprocessor based IDMT instantaneous relay with 3 O/C (50-200%) & one E/F protection (10-40%). To
maintain safety of the Indoor switchgear & Human resources in case of any internal ARC fault and also minimize
the damage, maintenance cost and downtime of the system, the system should have ARC flash protection system
with ACTIVE Arc flash protection
Antipumping relay & master trip relay
A set of breaker ON/OFF/Trip/DC control supply/Trip circuit healthy & R,Y, B phase indication lamps.
Required Auxiliary relays for WTI (Winding temperature indication with alarm & trip)
8-window annunciation panel with audio and visual indication
Digitally signed by ARTI
Over current & earth fault - 2 windows
Winding temperature trip alarm - 2 window
Master trip operated - 1 window
Spare window - 2 1 Set
Emergency trip push button on front door 1 Set/Panel
Limit switches with 6 NO/ 6 NC breaker auxiliary contacts 1 Set/Panel
Control:- T-N-C (Trip, Neutral, Close) breaker control switch. 1 Set/Panel
All control wiring with protection & test terminal block as required. 1 Set/Panel
Space heater with thermostat for moisture absorption. 1 Set/Panel
Cable box suitable for connection for 3C x 240sq.mm 11KV XLPE Al. conductor cable.1 set/pan
HT Danger Plate 1 Set/Panel
75X6mmAl earth bus to be provided for full length of the panel
Outgoing as described above.
HT Panel as described above (1 No.Incoming / 2 No Outgoing Panel) Set 1 660,299.51 660,299.51
MR- 04 11/0.433KV OIL TYPE TRANSFORMER
Supplying, installation, testing and commissioning of following capacity (continuous loading) BEE 3 Star rated
(Corresponding Level as per BIS amended upto date of receipt of tender) , 11/0.433 KV step down, 3 Phase, 50
Hz, Dyn 11 vector group, ONAN (Oil Natural Air Natural) copper wound transformer (Electrolytic grade 99.9%
pure copper, Core made of first grade Cold Rolled Grain Oriented (CRGO) Core grade MOH or better, suitable
for out door/indoor applications with On Load Tap Changer (OLTC) on HV side having AVR relay and Remote
Tap Changer Control (RTCC) for automatic sensing of incoming voltage, automatic operation of OLTC and
facility for remote and manual operation of OLTC HV side in range of +5% to -15% in steps of 2.5%, having
cable end boxes on HV side suitable for 3x300 sqmm XLPE cable of 11 KV grade, including bus trunking
arrangement on LV side including supplying and laying of copper conductor multicore control cable from
transformer to HT breaker/panel for safety tripping, complete with all accessories and safety provisions as per
relevant IS Code including first filling of filtered dehydrated oil, i/c supplying and grouting of suitable M.S.
Channel with all accessories and transformer shall be confirming to IS : 2026 (Part 1 to Part 5), IS : 1180 and as
per CPWD specifications complete in all respects etc as required at site. The maximum flux density in any part of
the core and yoke at rated voltage and frequency shall be such that the flux density with + 12.5 percent combined
voltage and frequency variation from rated voltage and frequency does not exceed 1.9 Tesla. The permissible
temperature-rise shall not exceed 35 0C for oil and 40 0C up to 200 KVA and 40 0C for oil and 45 0C for above
200 KVA for winding. Inside of tank shall be painted with varnish or liquid resistant paint. For external surfaces
one coat of thermo setting powder paint or one coat of epoxy primer followed by two coats of polyurethane base
paint shall be used. IS: 1180 (Part 3) shall be referred to for paint thickness for normal to medium corrosive
atmosphere. For highly polluted atmosphere and special application external paint work shall be as per direction
of Engineer-in-Charge. Design ambient condition: a) air temperature 50 0C, b) Relative Humidity 90 % Max, c)
Seismic Zone as per location of site, d) Altitude as per location/site. Noise level Shall not exceed limits as per
NEMA TR-1 with all accessories running measured as per IEC 551 / NEMA standard. The transformer should
800 KVA, 11/0.433KV OIL TYPE TRANSFORMER Each 1 3991144 3991144
MR- 05 Supply, Installation, testing and commissioning of 100 AH capacity, 24V DC maintenance free SMF Batteries in
fully charged condition, including painted MS stand & spill proof plastic trays etc.complete as required as per Set 4 27,879.31 111517.25
specifications.
MR- 07 Supply, Installation, Testing & Commissioning of Battery Charger Unit with provisions of "Boost Charging" and
"Float Charging", suitable for 240V, single phase, AC, 50Hz supply system & 24V DC including providing No 2 23,477.32 46954.63
required MCB for DC supply distribution to panel complete as required.
MR- 08 Supply and fixing in position the approved "shock treatment charts" framed in teak wood frame and covered with
glass in front as required in two languages (Hindi & English)
MR- 09 Supply & fixing of Mimic diagram for overall schematic of power distribution complete as required. Set 2 7,336.66 14673.32
Digitally signed by ARTI
MR- 10 Supply and fixing in position the best quality "Danger Boards" of approved shape and size as specified by Local
Electricity Authorities written in English and Local languages.
Supply & Laying of non skid Electro mat 1 mtr wide and 3.0 mm thick 11 KV grade conforming to IS 15652 as
required including cutting to required length complete as per requirement of local electricity authorities.
MR- 14 Supply of fire buckets 5 nos. 15 litre capacity duly filled with fine sand and fixed on an angle iron frame as per
requirement of local authorities. The fire buckets shall be painted red from outside and white from inside, Set 2 9,537.66 19075.32
including lettered as FIRE with white colour with extra handle at bottom.
MR- 15 Supply & Laying of non skid Electro mat 1mtr wide and 2.0 mm thick 11 KV grade IS 15652 as required
including cutting to required length complete as per requirement of local electricity authorities.
MR- 16 Supply of Rubber hand gloves 11 KV grade, as per IS 4770-1968. Pair 5 1,760.80 8803.99
MR- 17 Supply of standard first aid box as approved by Indian red cross society/ St.John Ambulance Brigade and
conforming to IS 2217-1963.
MR- 18 Supply & Installation of Earthing Trucks (Casette type) of same Make as HT Panel complete as required. Set 2 176079.87 352159.74
MR- 19 Supply, Receiving, shifting, laying, testing and commissioning of following 1100V grade PVC insulated
armoured copper conductor control cables on existing cable tray/ trench as per specifications including of all
clamps/ saddles/screw and cable identification tags etc. complete as required including termination of the
following sizes of PVC insulated Copper conductor cable including providing terminal lugs,single compression
gland , crimping the joints ,providing insulation tape,effecting terminal connections to the equipment.(For HT
Panel controls, Transformer Protection, PLC controls.
A a. 2C X 2.5sq.mm Cu. Cable RM 60 513.57 30813.98
C c. 2C X 1.5sq.mm Cu. Cable RM 60 418.19 25091.38
D d. 12C X 1.5sq.mm Cu. Cable RM 50 953.77 47688.30
MR- 21 MAIN LT Panel
A INCOMER FROM TRANSFORMER
A From 800KVA Transformer
1 No. 1000A 4 pole microprocessor based EDO, ACB(50kA) with integral protection as per PRMB-1 mentioned
i) 1 set of 1000/5A, 15 VA, class-.2S CTs for APFC relay
ii) 1 set of R,Y,B phase indicating lamps each with 3 nos. 2A SP MCBs.
iii) 1 No. (0-500V) Voltmeter with Built-in VSS with 3 nos. 2A SP MCB
iv) 1 No. (0-1000A) Ammeter with ASS with 3 nos. 1000/5A CT's
v) 1Set- of ON/OFF/Trip/ Spring Charged & Trip circuit healthy indicating lamps.
vi) 240 V AC Motor wound spring closing mechanism
vii) 1 - 24 volts DC shunt trip coil
viii) 6 nos NO/NC contacts for remote opening & closing
ix) Terminals to receive XLPE insulated Aluminium cables
x) Class – B transient voltage surge suppression devices suitable for 3 phases as per specification.
xi) Multifunction meter with display of V,I,PF,Energy,Power, Harmonics up to 15th order & %THD with RS485
B From 62.50 KVA DG SET-1
1 No. 400A 4 pole microprocessor based EDO, ACB with integral protection as per PRMB-1 mentioned in Premable
1 set of 400/1A, 15 VA, class-.2s CTs for Metering
Digitally signed by ARTI
1 set of 400/1A, 15 VA, class-5P10 CTs for Protection Relay
1 set of R,Y,B phase indicating lamps each with 3 nos. 2A SP MCBs.
1 No. (0-500V) Voltmeter with Built-in VSS with 3 nos. 2A SP MCB
1 No. (0-400A) Ammeter with ASS with 3 nos. 630/5A CT's
Multifunction meter with display of V,I,PF,Energy,Power, Harmonics up to 15th order & %THD with RS485 port
240 V AC Motor wound spring closing mechanism
1 - 24 volts DC shunt trip coil
6 nos NO/NC contacts for remote opening & closing
Terminals to receive XLPE insulated Aluminium cables
Class – B transient voltage surge suppression devices suitable for 3 phases as per specification.
Multifunction meter with display of V,I,PF,Energy,Power, Harmonics up to 15th order & %THD with RS485 port
Emergency Push Button with Each Incomer
DG Sync as per PLC
Electrolytic high conductivity Aluminium three phase and neutral busbars with earthing rated at 1250 amps
having a maximum current density of 1 amp per sq mm suitable to with stand symmetrical fault level of 50 kA at
415 volts. The neutral busbar is to be of 50% capacity.
D OUTGOINGS-Bus Section-1
iii) 2 No. 315A TP+NL MCCB(35KA) complete with:
3 nos 400/5A Class - .2S, 15 VA Burden CT's for metering
ON / OFF indicating lamps with MCB as backup protection.
Digital Three Phase, four wire, multifunction Meter with V, A, KWH, 485 Communication Port, Class of
Accuracy-1 as specified.
iv) 2 No. 160A TP+NL MCCB(50KA) complete with:
3 nos 160/5A Class - .2S, 15 VA Burden CT's for metering
ON / OFF indicating lamps with MCB as backup protection.
Digital Three Phase, four wire, multifunction Meter with V, A, KWH, 485 Communication Port, Class of
Accuracy-1 as specified.
v) 2 No. 200A TP+NL MCCB(50KA) complete with:
3 nos 100/5A Class - .2S, 15 VA Burden CT's for metering
ON / OFF indicating lamps with MCB as backup protection.
Digital Three Phase, four wire, multifunction Meter with V, A, KWH, 485 Communication Port, Class of
Accuracy-1 as specified.
v) 3 No. 63A TP+NL MCCB(50KA) complete with:
3 nos 100/5A Class - .2S, 15 VA Burden CT's for metering
ON / OFF indicating lamps with MCB as backup protection.
Digital Three Phase, four wire, multifunction Meter with V, A, KWH, 485 Communication Port, Class of
Accuracy-1 as specified.
E BUS COUPLER - 1
i.1 No. 630A 4 pole microprocessor based EDO, MCCB(50kA) with integral protection as per PRMB-1
mentioned in Premable
a. 6 Nos. NO/NC contacts for remote opening & closing
b. Red/Green / Amber / ON/OFF / Trip indicating lamps with 2A SP MCB as backup protection.
c. Backup MCB and terminal blocks as required.
d. TNC Breaker Control switch
Digitally signed by ARTI
e. Required Interlocking with other incomers & Bus Coupler to be provided as per Interlocking / operation
A From 800KVA Transformer
1 No. 1000A 4 pole microprocessor based EDO, ACB(50kA) with integral protection as per PRMB-1 mentioned
i) 1 set of 1000/5A, 15 VA, class-.2S CTs for APFC relay
ii) 1 set of R,Y,B phase indicating lamps each with 3 nos. 2A SP MCBs.
iii) 1 No. (0-500V) Voltmeter with Built-in VSS with 3 nos. 2A SP MCB
iv) 1 No. (0-1000A) Ammeter with ASS with 3 nos. 1000/5A CT's
v) 1Set- of ON/OFF/Trip/ Spring Charged & Trip circuit healthy indicating lamps.
vi) 240 V AC Motor wound spring closing mechanism
vii) 1 - 24 volts DC shunt trip coil
viii) 6 nos NO/NC contacts for remote opening & closing
ix) Terminals to receive XLPE insulated Aluminium cables
x) Class – B transient voltage surge suppression devices suitable for 3 phases as per specification.
xi) Multifunction meter with display of V,I,PF,Energy,Power, Harmonics up to 15th order & %THD with RS485
B From 62.50KVA DG SET-1
1 No. 400A 4 pole microprocessor based EDO, ACB with integral protection as per PRMB-1 mentioned in Premable
1 set of 400/1A, 15 VA, class-.2s CTs for Metering
1 set of 400/1A, 15 VA, class-5P10 CTs for Protection Relay
1 set of R,Y,B phase indicating lamps each with 3 nos. 2A SP MCBs.
1 No. (0-500V) Voltmeter with Built-in VSS with 3 nos. 2A SP MCB
1 No. (0-400A) Ammeter with ASS with 3 nos. 630/5A CT's
Multifunction meter with display of V,I,PF,Energy,Power, Harmonics up to 15th order & %THD with RS485 port
240 V AC Motor wound spring closing mechanism
1 - 24 volts DC shunt trip coil
6 nos NO/NC contacts for remote opening & closing
Terminals to receive XLPE insulated Aluminium cables
Class – B transient voltage surge suppression devices suitable for 3 phases as per specification.
Multifunction meter with display of V,I,PF,Energy,Power, Harmonics up to 15th order & %THD with RS485 port
Emergency Push Button with Each Incomer
DG Sync as per PLC
Electrolytic high conductivity Aluminium three phase and neutral busbars with earthing rated at 1000 amps
having a maximum current density of 1 amp per sq mm suitable to with stand symmetrical fault level of 50 kA at
415 volts. The neutral busbar is to be of 50% capacity.
D OUTGOINGS-Bus Section-1
iii) 2 No. 315A TP+NL MCCB(35KA) complete with:
3 nos 400/5A Class - .2S, 15 VA Burden CT's for metering
ON / OFF indicating lamps with MCB as backup protection.
Digital Three Phase, four wire, multifunction Meter with V, A, KWH, 485 Communication Port, Class of
Accuracy-1 as specified.
iv) 2 No. 160A TP+NL MCCB(50KA) complete with:
Digitally signed by ARTI
3 nos 160/5A Class - .2S, 15 VA Burden CT's for metering
ON / OFF indicating lamps with MCB as backup protection.
Digital Three Phase, four wire, multifunction Meter with V, A, KWH, 485 Communication Port, Class of
Accuracy-1 as specified.
v) 3 No. 100A TP+NL MCCB(50KA) complete with:
3 nos 100/5A Class - .2S, 15 VA Burden CT's for metering
ON / OFF indicating lamps with MCB as backup protection.
Digital Three Phase, four wire, multifunction Meter with V, A, KWH, 485 Communication Port, Class of
Accuracy-1 as specified.
v) 3 No. 63A TP+NL MCCB(50KA) complete with:
3 nos 100/5A Class - .2S, 15 VA Burden CT's for metering
ON / OFF indicating lamps with MCB as backup protection.
Digital Three Phase, four wire, multifunction Meter with V, A, KWH, 485 Communication Port, Class of
Accuracy-1 as specified.
LT PANEL DESCRIVED ABOVE Set 1 1,320,599.02 1320599.02
MR- 22 SCHOOL MAIN PANEL
1 No. 315amps 4P MCCB(25KA) PRTM with Class-C transient voltage surge suppression device suitable for 3
phases as per specifications.
METERING & INDICATION for each Incomer
1 set of R,Y,B And ON/OFF phase indicating lamps
Multifunction digital meter (consisting of Voltage, Current, Frequency, PF, kWh, kVA, harmonics upto 15th
order & %THD) with RS-485 Port.
Sets of 500/5A, CL-1, 15VA CTs for measuring.
Sets of phase indicating lamp with 2A control MCBs.
500A TP+100%N Aluminium Bus Bar with colour coded PVC Sleeves
6 Nos. 100 Amp 4P MCCB
5 Nos. 63 Amp 4P MCB
PROVISION OF SPACE FOR 30 NOS METER
LIGHT POWER, PANEL DESCRIVED ABOVE set 1 660,299.51 660299.51
MR- 23 SCHOOL FLOOR PANEL
1 No. 100amps 4P MCCB(25KA) PRTM with Class-C transient voltage surge suppression device suitable for 3
phases as per specifications.
METERING & INDICATION for each Incomer
1 set of R,Y,B And ON/OFF phase indicating lamps
Multifunction digital meter (consisting of Voltage, Current, Frequency, PF, kWh, kVA, harmonics upto 15th
order & %THD) with RS-485 Port.
Sets of 100/5A, CL-1, 15VA CTs for measuring.
Sets of phase indicating lamp with 2A control MCBs.
125A TP+100%N Aluminium Bus Bar with colour coded PVC Sleeves
Digitally signed by ARTI
4 Nos. 63 Amp 4P MCCB
15 Nos. 63 Amp 4P MCB
PANEL DESCRIVED ABOVE set 4 308,139.77 1232559.08
1 No. 63amps 4P MCCB(25KA) PRTM with Class-C transient voltage surge suppression device suitable for 3
phases as per specifications.
METERING & INDICATION for each Incomer
1 set of R,Y,B And ON/OFF phase indicating lamps
Multifunction digital meter (consisting of Voltage, Current, Frequency, PF, kWh, kVA, harmonics upto 15th
order & %THD) with RS-485 Port.
Sets of 63/5A, CL-1, 15VA CTs for measuring.
Sets of phase indicating lamp with 2A control MCBs.
80A TP+100%N Aluminium Bus Bar with colour coded PVC Sleeves
4 Nos. 63 Amp 4P MCCB
4 Nos. 63 Amp 4P MCB
2Nos.40 Amp DP MCB
PROVISION OF SPACE FOR 4 NOS METER
MR- 24 LIFT PANEL
1 No. 63amps 4P MCCB(36KA) with thermal Magnetic release (PRTM) with Class-C transient voltage surge
suppression device suitable for 3 phases as per specifications.
METERING & INDICATION for each Incomer
1 set of R,Y,B phase indicating lamps
Multifunction digital meter (consisting of Voltage, Current, Frequency, PF, kWh, kVA, harmonics upto 15th
order & %THD) with RS-485 Port.
Sets of 60/5A, CL-.2S, 15VA CTs for measuring.
Sets of phase indicating lamp with 2A control MCBs.
100 A TPN Aluminium Bus Bar with colour coded PVC Sleeves
2 Nos. 40 Amp TP MPCB
2 Nos. 40 Amp TP MCB
2 Nos.40 Amp DP MCB
Lift Panel as described above Set 1 162,873.88 162873.88
MR- 25 Capacitor Panel (75kVAR)
1 No 160A MCCB TP 50KA
1 Nos. 0 to 440 Volt digital voltmeter with Voltmeter Selector Switch & Protective SP MCB 10KA C Curve
(96mm square) (one for each Incoming Breaker).
3 No. 0 to 160Amp digital ammeter (96mm square) with CT's.
1 Sets of phase indicating lights (RYB) with protection fuses (one set for each incoming breaker).
1 Sets breaker 'ON' & 'OFF' indicating lamp (one set for each incoming breaker).
Digitally signed by ARTI
8 Step Automatic Power Factor Correction relay (APFC relay).
160Amp TP busbars of aluminium alloy as per SLD.
1 Nos.125 Amp TP MCCB.
3 Nos. capacitor duty contactor (one for each 50 KVAR capacitor unit with APP type Capacitor bank)
2 Nos.63 Amp TP MCCB.
2 Nos. capacitor duty contactor (one for each 10KVAR ccapacitor unit with APP type Capacitor bank)
3 Nos. 40 Amp TP MCCB.
3 Nos. capacitor duty contactor (one for each 5KVAR capacitor unit with APP type Capacitor bank)
10 sets of push button stations Red and Green for manual operation of capacitor units with auto/manual selector
1 No. Indicating lamp for each 100 / 50/ 10 KVAR capacitor unit to indicate that the unit is 'ON'.
1 No. Toggle switch for changing automatic to manual operation of capacitor units.
Power factor meter.
Capacitor Panel Described as above set 1 220,099.84 220099.84
MR-26 PLUMBING PANEL
1 No. 63amps 4P MCCB(25KA) with thermal Magnetic release (PRTM) with Class-C transient voltage surge
suppression device suitable for 3 phases as per specifications.
METERING & INDICATION for each Incomer
1 set of R,Y,B phase indicating lamps
Multifunction digital meter (consisting of Voltage, Current, Frequency, PF, kWh, kVA, harmonics upto 15th
order & %THD) with RS-485 Port.
Sets of 63/5A, CL-.2s, 15VA CTs for measuring.
Sets of phase indicating lamp with 2A control MCBs.
80A TPN Aluminium Bus Bar with colour coded PVC Sleeves
6 No. 63amps 4P MCB
6nos suitable starter
PLUMBING PANEL DESCRIVED ABOVE set 1 132,059.90 132059.90
MR- 27 EXTERNAL LIGHTING PANEL
1 No. 63amps 4P MCCB(16KA) with thermal Magnetic release (PRTM) with Class-C transient voltage surge
suppression device suitable for 3 phases as per specifications.
METERING & INDICATION for each Incomer
1 set of R,Y,B phase indicating lamps
Multifunction digital meter (consisting of Voltage, Current, Frequency, PF, kWh, kVA, harmonics upto 15th
order & %THD) with RS-485 Port.
Sets of 60/5A, CL-.2s, 15VA CTs for measuring.
Sets of phase indicating lamp with 2A control MCBs.
100A TPN Aluminium Bus Bar with colour coded PVC Sleeves
Digitally signed by ARTI
8 No. 40amps 4P MCB
EXTERNAL LIGHTING PANEL DESCRIVED ABOVE set 1 205,426.51 205426.51
MR- 28 UPS FLOOR PANEL
1 No. 63amps 4P MCCB(16KA) with thermal Magnetic release (PRTM) with Class-C transient voltage surge
suppression device suitable for 3 phases as per specifications.
METERING & INDICATION for each Incomer
1 set of R,Y,B phase indicating lamps
Multifunction digital meter (consisting of Voltage, Current, Frequency, PF, kWh, kVA, harmonics upto 15th
order & %THD) with RS-485 Port.
Sets of 63/5A, CL-.2s, 15VA CTs for measuring.
Sets of phase indicating lamp with 2A control MCBs.
80A TPN Aluminium Bus Bar with colour coded PVC Sleeves
5 No. 63amps 4P MCB
3 No. 40amps DP MCB
UPS PANEL DESCRIVED ABOVE set 1 132,059.90 132059.90
Total of Sub-Head - I carried to summary sheet 0.00 10267464
SUB-HEAD - II - DG SET WORK
1.0 62.5 KVA RADIATOR COOLED D.G. SET IN ACOUSTIC ENCLOSURE
1.1 Providing, installation testing & commissioning of 'Silent Type' Diesel Generating Set along with having prime
power rating 62.5 KVA, 415 Volts at 1500RPM, 0.8 lagging Factor at 415 V suitable for 50 Hz, 3 phase system 0.00
and for 0.85 load factor and consisting of the following:-
a) Diesel Engine 0.00
Diesel Engine 4 stroke radiator cooled, electric start, of suitable BHP at 1500 RPM suitable for above output of
alternator at 400C, 50% RH & at 1000 metre MSL and confirming to BS 5514, BS 649, is 10000, capable of
taking 10% overloading for one hour after 12 hours of continuous operation. The engine will be fitted complete
with all the required accessories.
b) Engine Mounted Instrument Panel fitted with and having digital display for following:
(i) Start- stop switch with key.
(ii) Water Temperature indication
(iii) Lubrication Oil pressure indication
(Iv) Battery charging indication
(v) RPM indication
(vi) Over Speed trip Indication
(vii) Low lubrication oil trip indication
(viii) Engine Hours Indication
c) Alternator:
Synchronous alternator rated at sutable KVA, 415 Volts at 1500 RPM, 3 phase 50 Hz, AC Supply with 0.8
lagging power factor at 400C, 50% RH & at 1000 metre MSL. The alternator shall be having SPDB enclosure,
brushless, continuous duty, self-excited and self-regulated through AVR confirming to IS:4722/ BS 2613 suitable
for tropical conditions and with class- F insulation. Alternator shall have provision of end termination of
Aluminium Bus Duct.
d) Base Frame & Foundation
Digitally signed by ARTI
Both the engine and alternator shall be mounted on suitable base frame made of MS channel with necessary
reinforcement which shall be installed on suitable cement concrete foundation and vibration isolation arrangement
as per recommendations of manufacturer.
Daily service fuel tank of 850 litres capacity, fabricated out of 3mm thick M.S. sheet complete with all standard
accessories and fuel piping between fuel tank and diesel engine with MS class 'C pipes of suitable dia. Complete
with valves level indication & accessories as required as per specifications.
f) Exhaust System :
Dry exhaust mainfold with hospital grade exhaust silencer.
g) Starting System:
24V DC starting system comprising of starter motors: voltage regulator and arrangement for initial excitation
complete with 2 Nos. of batteries (25 plates, 160 AH lead Acid type) as required as per specifications.
h) Accoustic and weather proof enclosure with arrangement for fresh air intake for cooling of the engine &
alternator, extraction, discharging hot air into the atmosphere as per specifications. The Acoustic Enclosure shall
be factory fitted by the OEM.
i) The DG Set shall be provision of SCADA compatibility.
DSR 2025 Diesel Generating Set(62.5KVA) including Acoustic Enclosure. described as above.
2.0 EXHAUST PIPING
2.1 Supply, Installation, Testing and Commissioning of following sizes MS exhaust piping heavy duty conforming to
MR-29 IS:3589 complete with all accessories such as bends, flanges, stainless steel flexible bellows etc. as required.
2.2 MR- 30 200 mm dia MS pipe. (5.0 mm thick) Meter 15 4048 60 715
Providing & Fixing of Insulation and aluminium cladding for exhaust piping using 75 mm thick rockool of
density 150 Kg/ M3 & 24 SWG Aluminium Sheet.
2.4 DSR-CIVIL-10.25 Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a
priming coat of approved steel primer using structural steel etc. as required. The contractor shall submit the
structure strength calculation for approval before execution.
2.5 DSR-CIVIL-10.25.2 In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works. KG 1045 172.60 1 80 367
Total of Sub-Head - II carried to summary sheet 777820 191527
DSR-2025 SUB HEAD- III : EARTHING
1.0 Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure Set 61264
5.2 with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. 8 7658
2.0 5.4 Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry Set 6 50106
enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ 8351
coke and salt as required.
3.0 5.6 Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry Set 8 120032
enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ 15004
coke and salt as required.
4.0 5.7 Supplying and laying 6 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode, including Metre 100 6200
connection/ termination with GI thimble etc. as required.
5.0 5.10 Providing and fixing 25 mm X 5 mm copper strip in 40 mm dia G.I. pipe FRLSom earth electrode including Metre 50 81900
connection with brass nut, bolt, spring, washer excavation and re-filling etc. as required.
6.0 5.11 Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection Metre 100 75500
with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required.
7.0 5.12 Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe Metre 100 31300
from earth electrode including connection with G.I. thimble excavation and re-filling as required.
Digitally signed by ARTI
8.0 5.14 Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required. Metre 50 62300
9.0 5.15 Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required. Metre 150 287 43050
10.0 5.16 Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required. Metre 80 84 6720
Total of Sub-Head - III carried to summary sheet 538372 0
DSR- 2025 SUB HEAD-IV: CABLE & END TERMINATIONS
1.0 10.1 Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size
direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as
b 10.1.2 Above 35 sq. mm and upto 95 sq. mm Metre 30 475 14250
c 10.1.3 Above 95 sq. mm and upto 185 sq. mm Metre 75 497 37275
d 10.1.4 Above 185 sq. mm and upto 400 sq. mm Metre 150 564 84600
2.0 10.5 Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size
in the existing RCC/ HUME/ METAL pipe as required.
b 10.5.2 Above 35 sq. mm and upto 95 sq. mm Metre 50 72 3600
c 10.5.3 Above 95 sq. mm and upto 185 sq. mm Metre 50 97 4850
d 10.5.4 Above 185 sq. mm and upto 400 sq. mm Metre 80 170 13600
3.0 10.6 Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size
in the existing masonry open duct as required.
b 10.6.2 Above 35 sq. mm and upto 95 sq. mm Metre 100 58 5800
c 10.6.3 Above 95 sq. mm and upto 185 sq. mm Metre 100 80 8000
d 10.6.4 Above 185 sq. mm and upto 400 sq. mm Metre 75 146 10950
4.0 10.8 Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of
following size on cable tray as required.
a 10.8.1 Upto 35 sq. mm (clamped with 1mm thick saddle) Metre 100 53 5300
b 10.8.2 Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp) Metre 100 109 10900
c 10.8.3 Above 95 sq. mm and upto 185 sq. mm (clamped with 25/40x3mm MS flat clamp) Metre 50 138 6900
d 10.8.4 Above 185 sq. mm and upto 400 sq. mm (clamped with 40x3mm MS flat clamp) Metre 50 226 11300
e 10.10 Supplying and fixing cable route marker with 10 cm X 10 cm X 5 mm thick G.I. plate with inscription there on, Each 75 598 44850
bolted /welded to 35 mm X 35 mm X 6 mm angle iron, 60 cm long and fixing the same in ground as required.
7.0 11.1 Supplying and making end termination with brass compression gland and aluminium lugs for following size of
PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.
Digitally signed by ARTI
11.0 MR- 32 Supply of LT cable
Supply, following sizes of PVC sheathed PVC/XLPE insulated Aluminium conductor/copper conductor power/
multicore control armoured cable of 1.1 KV grade.
a MR-32.1 3.5C X 300 Sqmm Aluminium Cable Metre 52 5586 290479
b MR-32.2 3.5C X 240 Sqmm Aluminium Cable Metre 50 4519 225969
c MR-32.3 3.5C X 185 Sqmm Aluminium Cable Metre 50 3591 179528
d MR-32.4 3.5C X 150 Sqmm Aluminium Cable Metre 50 2891 144532
e MR-32.5 3.5C X 120 Sqmm Aluminium Cable Metre 50 2426 121275
f MR-32.6 3.5C X 95 Sqmm Aluminium Cable Metre 54 1927 104037
g MR-32.7 3.5C X 70 Sqmm Aluminium Cable Metre 35 1482 51870
h MR-32.8 3.5C X 50 Sqmm Aluminium Cable Metre 45 1096 49324
i MR-32.9 3.5C X 35 Sqmm Aluminium Cable Metre 45 832 37439
j MR-32.10 4C X 25 Sqmm Aluminium Cable Metre 25 660 16507
k MR-32.11 4C X 16 Sqmm Aluminium Cable Metre 40 524 20954
l MR-32.12 4C X 10 Sqmm Aluminium Cable Metre 50 406 20323
m MR-32.13 4C X 6 Sqmm Aluminium Cable Metre 45 333 14989
n MR-32.14 3C X 10 Sqmm Aluminium Cable Metre 50 371 18562
o MR-32.15 3C X 6 Sqmm Aluminium Cable Metre 45 289 13008
p MR-32.16 2C X10Sqmm Aluminium Cable Metre 50 406 20323
Total of Sub-Head - IVcarried to summary sheet 403921 1329118.349
SUB HEAD-V : EXTERNAL LIGHTING
1) Supply of following sizes XLPE insulated (Heavy duty) Cu conductor armoured cables suitable for working
voltage upto and including 1100 Volts complete as required and as per specifications.
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size
2 direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size
in the existing RCC/ HUME/ METAL pipe as required.
4) Termination of the following sizes of XLPE insulated Aluminium/ Copper conductor cable including providing
terminal lugs,double compression gland , crimping the joints ,providing insulation tape,effecting terminal
connections to the equipment complete as required.
a MR-35 2 x 6 sq,mm, Al conductor cable Nos. 33 953.77 31,474.28
5) Supply, laying and termination of the following sizes of 650/1100 volts grade PVC insulated copper conductor
wires in existing conduits including end terminations with copper lugs.
a. DSR-2022-1.17.12 3 x 2.5 sq.mm. Copper conductor ,PVC insulated PVC sheathed wires RM 130 148 19,242.09
b. DSR-2022-1.14.4 2 X 6 sq. mm + 1 x 6 sqmm earth wire RM 83 482 40,006.00
Digitally signed by ARTI
6) Supplying and fixing in position of the following sizes of GI conduit buried in ground 600 mm deep including all
accessories complete as required and as per specifications.
a. DSR-2022-1.20.2 25 mm dia GI conduit RM 50 256 12,800.00
Providing, laying and fixing following dia RCC pipe NP2 class (light duty) in ground complete with RCC collars,
7 jointing with cement mortar 1:2 (1 cement : 2 fine sand) including trenching (75 cm deep) and refilling etc as
8) Supply,fixing and laying of Heavy duty PVC pipes complete buried in floor with joints and other accessories as
a) MR-36 63 mm dia, 2mm thick RM 50 97 4,842.20
Including supply and installation of 6 ways-20A connector & 6A MCB mounted on 6mm thick painted M.S/GI
plate, insulated, and fixed inside the pole suitable for termination of armoured aluminium cable as required and
wiring to Luminaries from the 6A MCB, with 3x2.5 sq.mm. PVC insulated copper, stranded conductor
(P+N+PE) double sheathed wire including terminations.
4 meters high tubular pole with single arm of length 1 meter, smoothly curved making an angle of 10 deg to 15 Nos. 25
deg with the horizontal plane complete as required.
MR-37 Supply, erection, testing and commissioning of 6 M high Tubular pole as per Technical specifications and with following
Including supply and installation of 6 ways-20A connector & 6A MCB 10KA C Curve mounted on 6mm thick painted M.S/GI
plate, insulated, and fixed inside the pole suitable for termination of armoured aluminium cable as required and wiring to
Luminaries from the 6A MCB 10KA C Curve, with 3x2.5 sq.mm. PVC insulated copper, stranded conductor (P+N+PE) double
sheathed wire including terminations.
6 meters high tubular pole with single arm of length 1.5 meter, smoothly curved making an angle of 10 deg to 15 deg with the Nos. 0
horizontal plane complete as required.
10) LED Street light fixture, powder coated pressure die cast aluminium body (System lumen efficacy ≥120
Supplying of Street light LED fixture powder coated pressure die cast aluminium body with driver as per the
requirement with Driver efficiency >85%, Input voltage: 140-270 Volt AC, freq 50/60 hz, Operating temp range -
15 deg to 50 deg centigrade, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency
>85%,THD < 10% as per IEC 61000- 3-2 , P. F.≥0.95, IP-66,IK-10, CRI >80, 5-Star Rating under voltage and
over voltage protection, EMI-EMC As per CISPR 15 , lenses for beam angle as per IESNA type I/II/III as per the
width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (LED,Driver &
electrical circuitary) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per
LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin),
SDCM(Standard Deviation Color Matching) <5, Maximum power consumption should not more than the
specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c connections with 1.5 sq
mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year
OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output . LM79 & LM80 Test report from NABL lab
for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved
by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED
junction temperature shall not rise above 90°C).
11) MR LED Flood Light, powder coated pressure die cast aluminium (System lumen efficacy >135 lm/Watt)
Digitally signed by ARTI
Supplying of Flood Light, powder coated pressure die cast aluminium body with built in or separate driver as per
the requirement with Driver efficiency >85%, Input voltage: Input voltage: 140-270 Volt AC, freq 50/60 hz,
Operating temp range -15 deg to 50 deg centigrade, internal surge rotection of 5 KV L,N,E as per IEC 61000-4-5,
Driver efficiency >85%,THD < 10% as per IEC 61000-3-2 , P. F.≥0.95, IP-66,IK-10, CRI >80 , 5-Star Rating
under voltage and over voltage protection,EMI-EMC as per CISPR-15, lenses for beam angle 30 deg-120deg as
per the application and the project requirementdeg., suitable tilt able fitting, life time (LED,Driver & electrical
circuitary) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80
extrapolation IES TM-21-11 report , CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) ,
SDCM(Standard Deviation Color Matching) <5, Maximum power consumption should not more than the
specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c connections with 1.5 sq
mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year
OEM warranty. System lumen efficacy >135 lm/Watt output . LM79 & LM80 Test report from NABL lab for all
testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by
Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED
junction temperature shall not rise above 90°C).
12) MR-41 Supply,Receiving and fixing in position, effecting proper connections, testing and commissioning of 9W LED 20
13) MR-42 Supply,Receiving and fixing in position, effecting proper connections, testing and commissioning of 35 W GATE 4
14) MR-43 Supply, Installation & Commissioning of Solar PV stand alone Street Lighting System comprising of two 37 Wp / one 74 Wp SPV
module, one 12 V, 75 Ah Tubular Plate sealed maintenance free VRLA Gel Battery, one luminaries with inbuilt inverter, dusk to
dawn circuit for automatic switching on & off at dusk & dawn and 24 W LED Light, pole, one charge-regulator, module mounting Nos 10 124,723.24 1,247,232.41
structure, Pole mounted Battery box, cables and other fittings along with 5 (five) years guarantee / warranty period (25 years for
15) MR-44 Supply, installation Testing including civil foundation work & commissioning of fixed type high mast lighting
tower (16 mtr.) with 8 Nos. 300 watt LED flood light fittings for outdoor lighting application.
Total of Sub-Head - V carried to summary sheet 184,920.09 2,502,223.33
SUB HEAD-VI : ROOF TOP PHOTO VOLTAIC (SPV) SYSTEM
Digitally signed by ARTI
Supplying Installation, Testing and Commissioning of on-grid Solar Photovoltaic Power Plant conforming to
various applicable standards BIS, IEC, MNRE guidelines, the Central Electricity Authority Regulations and
CPWD Specifications as amended up to date, consisting of Mono/Poly Crystalline silicon solar cells module, net
metering facility, necessary control, protections, earthing, cabling, mounting structure, junction boxes, power
conditioning units,Real time online web interfaced Data Monitoring System, Distribution panels, grid
connectingarrangement, conduits, pipes, cable trays and other accessories etc. as required. a) High Energy
Efficiency Solar Photovoltaic Module of capacity 540 Wp or above, manufactured in India,conforming to IS
14286/IEC 61215, IS/IEC 61730- Part-1, IS/IEC 61730-Part-2. Solar PhotovoltaicModule conversion efficiency
shall not be less than 23% at STC with temperature coefficient of Pmax better than -0.30% per 0C. PV modules
used in solar power plants/ systems must be warranted for their output peak watt capacity, which should not be
DSR-2025 less than 90% at the end of 10 years and 80% at the end of 25 years. Solar Modules shall be designed to operate
17.1 in relative humidity upto 100% with temperature between -10 0C and +85 0C. Further, each PV module used in
any solar power project must have Radio frequency identification tag with information such as name of
manufacturer, month and year of manufacturing, country of origin (separately for Solar cell and module), I-V
curve, Unique Serial No and Model No of the module, Wattage, Im, Vm and FF, name of test lab issuing IEC
certificate. b)Power Conditioning Unit (PCU) of 350-800 V DC Input voltage range and 415 V AC, three phase,
4 wire, 50Hz +/- 2.5 Hz, output voltage suitable to generate AC with a variation of 10% at nominal voltage.
Power with efficiency not less than 97%, total harmonic distortion less than 3% and suitable for ambient
temperature from 0 to 50 0C, Minimum IP-65 for outdoor and Minimum IP 21 for indoor, Built-in meter and data
logger, MPPT, switching devices IGBT/MOSFETs and controller Microprocessor /DSP. PCU/inverter shall be
capable of complete automatic operation including wake-up, synchronization & shutdown. The PCU shall be able
to withstand unbalanced load conforming to IEC standard with shutdown/standby mode. It must be provided with
Minimum along with
protections: manual
Mains disconnect
Under pole isolation
/ Over Voltage, switch besides
Over current, automatic
Over/Under grid disconnection.
frequency, Over temperature,
Surge voltage induced at output due to external source,Short-circuit, Lightening, Anti Islanding (for grid
synch.Mode) and other protections as per applicable standards. LCD/LED display of minimum parameters: DC
input voltage, DC current, AC Voltage and current (all 3 phases, in case of 3 phase), Instantaneous & cumulative
AC output power, Daily DC energy produced and other parameters applicable standard.Communication interface
RS 485 / RS 232.c) Module mounting structure: The roof top solar plantgeneration units shall be installed by
using supporting Aluminium/Galvanized MS structure (mass of zinccoating shall be as per IS4759 ) having
minimum head room clearance of 2.4 meter above the terrace level /ground level. The mounting structure would
be designed to sustain wind load and seismic parameter of the site of installation. All the structure shall be design
as per applicable BIS code and the material shall also confirm the applicable BIS Code. Structural material shall
be corrosion resistant and electrolytically compatible with the materials used in the module frame, its fasteners,
nuts and bolts. The suitable arrangements for maintenance and cleaning shall be provided. d) Real time online
web interfaced Data Monitoring System complete with accessories for various parameters such as Solar
Irradiance, temperature, AC Output Voltage and current, Output Power, Power factor, DC Input Voltage and
Current, Time Active, Time disabled, Time Idle, Power produced and other parameters as per standard practices.
e) Array junction box & Main junction box with IP 65 protection and termination arrangement for incoming and
outgoing cable along with glands, lugs and other accessories etc. as required.
Each junction box shall be made of GRP/FRP/Powder Coated Aluminium /cast aluminium alloy with full dust,
water & vermin proof arrangement with High quality Suitable capacity Metal Oxide Varistors(MOVs)
(semiconductor diode with resistant applied voltage)/ surge arrestors and suitable Reverse Blocking Diodes,
isolation switches isolate the DC input to Inverter, copper bus bar etc. f) Lightning, surge voltage protection,
earthing protection and grid islanding. g) Cables: Connections & Interconnections by required size IR/UV
protected XLPE insulated copper conductor 1.1 kV grade armored power and control cables(ISI Marked) along
Total of Sub-Head - VI carried to summary sheet 2,714,000.00 0.00
Digitally signed by ARTI
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
detail.html
html • 0.06 MB
GCC 2026 contractor PMC with all amendments.pdf
Tender Document
Design circular 01 16.pdf
Tender Document
integrity pact khajuri khas.pdf
Tender Document
Make List 30102026khajuri khas.pdf
Tender Document
Milestone Jhajuri khas.pdf
Tender Document
NIT Khajuri Khas3010.pdf
Tender Document
SCC khajuri khas.pdf
Tender Document
Soil Report.pdf
Tender Document
Technical Circulars 01 to 37.pdf
Tender Document
Technical Specification KVS khajuri3010.pdf
Tender Document
Tender Drawings khajuri khas.pdf
Tender Document
KVS Khajuri Khas BOQ.pdf
Tender Document
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .