Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹26.8 LAccepted-AOC D NO 39 33 88 2 PLOT NO MIG 208 MADHAVADHARA VUDA COLONY VISAKHAPATNAM 530018 | VISAKHAPATANAM | ANDHRA PRADESH | 530018 | L1 | Accepted-AOC THE LOWEST BIDDER | |
| 2 | L2₹29.5 L+₹2.6 L (9.49%)Rejected-Finance D NO 71 31 252 DURGANAGAR MALKAPURAM VISAKHAPATNAM 530011 | VISAKHAPATANAM | ANDHRA PRADESH | 530011 | L2 | Rejected-Finance OTHER THAN THE LOWEST BIDDER | |
| 3 | L3₹30.7 L+₹3.7 L (13.6%)Rejected-Finance | L3 | Rejected-Finance OTHER THAN THE LOWEST BIDDER | |
| 4 | L4₹30.7 L+₹3.7 L (13.8%)Rejected-Finance | L4 | Rejected-Finance OTHER THAN THE LOWEST BIDDER | |
| 5 | L5₹3.3 Cr+₹3.0 Cr (1120.9%)Rejected-Finance | L5 | Rejected-Finance OTHER THAN THE LOWEST BIDDER |
Tender Value
₹38.1 L
EMD Value
₹76,240
Closing Date
14 Jun 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
AGE (I) (CG) Vizag
AGE (I) (CG) Vizag Military Engineer Services CGWO, 530014
IMPROVEMENT OF CHANGING ROOM CUM DINNING HALL FOR ENROLLED PERSONNEL AT ICGS VISAKHAPATNAM UNDER AGE(I)(CG) VIZAG
2023_MES_596295_1
AGE(I)CG/VIZ/TOKEN 11 OF 2023-24
Open Tender
Miscellaneous Works
Item Rate
180 days
VISAKHAPATNAM
DETAILS AS PER NIT OF THIS TENDER
9 documents required · 9 mandatory
₹500
AGE (I) (CG) Vizag
₹76,240
Yes
19 Jun 2023
18 May 2023
16 Jun 2023
18 May 2023
14 Jun 2023
1 Jun 2023
Amount
Dismantling of plain corrugated steel sheeting any gauge thickness including Nainital and similar pattern complete all as specified and directed.
Taking down chowkats or frames exc 1.5 sqm but not exc. 4 sqm each with shutters (without taking off shutters from the frame) complete all as specified and directed.
Dismantling Structural steel work including doors, gates, grills but excluding framed truss etc.
Dismantling of floor or wall tiles, stone slab of any description or thickness laid, bedded and pointed in anymorter all as specified.
Demolition of brick work or stone/ boulder masonry, built in cement mortar including all quoins, pillars etc.
Excavation in trenches, not exceeding 1.5 meter wide and not exceeding 1.5 meter depth for foundation, etc., and getting out in hard/ dense soil.
M&L for plain cement concrete type D-2, 1:4:8 (using 40 mm graded stone aggregate) in foundations, filling and mass concrete.
M&L for reinforced cement concrete M-30 (nominal mix) (using 20 mm graded granite stone aggregate) in foundations including rafts, footings and plinth beams mass concrete.
M&L for reinforced cement concrete M-30 (nominal mix) (using 20 mm graded granite stone aggregate) in columns, piers, posts and struts.
M&L for reinforced cement concrete M-30 (nominal mix) (using 20 mm graded granite stone aggregate) in beams, cantilevers, lintels over 1.5 M span.
Use and waste of formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and so fits (if any) of foundation and plinth beams; and similar work; vertical or to batter for rough finished flat surface of concrete all as directed and as specified.
Use and waste of form to square, rectangular or polygonal Form work to sides of pillars, posts, struts, columns and stanchions.
Use and waste of form work to sides and soffits of floor or roof beams, lintels, cantilevers, shelves including supports etc.
Use and waste of form work to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping)
M&L for TMT bars 10 mm dia., and over cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia., or securing
M&L for TMT bars 6 to 8 mm dia., cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia., or securing
M&L for TMT bars 5 mm to 10 mm dia., cut to length, bent to shape required, in stirrups, spacers and binders and binding with mild steel wire (annealed) not less than 0.9 mm dia., or securing with clips.
M&L for brickwork with fly ash bricks, straight or curved on plan exc 6m mean radius, built in cement mortar 1:6
M&L for rendering 15 mm thick in cement mortar 1:4 on fair faces of brick work or concrete surfaces, finished even and smooth without using extra cement including mixing with liquid WPC all as per manufacturers instructions complete all as specified and as directed.. Note :- WPC will be measured and paid separately.
M&L rendering 15 mm thick in cement mortar 1:6 on stone masonry surfaces or surface other than fair face of brickwork finished even and smooth without using extra cement.
Supply only integral liquid water proofing compound.
M&L for factory made UPVC white colour sliding window three track (3 panel middle fixed with glass and both side sliding with mesh and glass) made of extrded profiles with wall thickness of 2.3mm+/-0.2mm. Window profile with hollow section with multi chmber. Frame (112mm*52mm), sliding sash (42mm+67mm), sliding mesh sash (42mm+57mm), sliding interlock (One vertical length in each shutters) (45.50mmx28mm). Glazing bead (24.50mm*16mm) will be mitred cut and fusion welded at all corneres including railing of holes ffor fixing hardware and drainage of water of etc. Making arrangement for fixing of hardware EPDM gascade 1.2+/-0.2mm thick galvanized steel frame (30mm*18mm) 2Nos, Sliding sash (30mm*18mm), Sliding mesh sash (26mm*10mm) profile to inserted in required profile, frame will be fixed to wall with 8mm*100mm long fastneres. Hardware (touch lock of zink alloyed (white powder coated), teel roller system, stainnless steel wire cloth of 0.36mm nominal dia of wire and avg width of aperature 1.40mm and required accessories). To be provided with proper operative and locking hardware mechanism, frame to be fixed to wall with high quality fasteners and silicon glue is to be applied to fill up gap between frame and wall to make leak proof area exceeding 2.0 sqm complete all as specifed and as per Manufacturer instructions. Note: The unit rate quoted by contractor excludes cost of 6mm thick tinted black glass, mesh includes all other connected accessories. Net opening will be measured for payment purpose.
M&L for anodised aluminium frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc complete all as spd and directed
M&L for rubber beading for fixing glass panes in aluminium frame work complete all as specified and directed
S&F 12mm thick Prelaminatd particle board, interior grade, prelaminated both side with decorative choice lamination fixed with screws to timber/aluminium frame work complete all as specified and directed.
S&F 5mm thick sheet glass, fixed to aluminum frame work in panels exc 0.5 sqm in each pane complete all as specified and directed
S&F Floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring. Fixed in floor (140mm size) complete all as specified and directed
S&F 200mm long Aluminium, anodised, barrel tower bolts of extruded section and fixed complete all as specified and directed.
S&F 125mm long Extruded aluminium alloy handles, fabricated type., anodised complete all as specified and directed.
M&L for Door closer hydraulically regulated (dia cast) body, designation No 3, universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between (61 to 80)kg and fixed complete all as specified and directed.
M&L for mortice lock, vertical type, size 100mm, 2 lever vertical complete all as specified and directed.
Supply and fixing including fabrication, in position, false ceiling comprising of grid system of armstrong/gypsum india etc for frame work with GI powder coated angle wall runners of size 19X19mm, cross tee of size (24X24) mm & main tee of size (34X24) mm at 600 mm c/c to form grid of (600X600)mm filled with 15mm thick tegular edges of insulation ARMSTRONG ceiling tiles of mineral woll rock / fibres make of approved designer false ceiling shall be suspended from roofs on main runners @ 0.9M c/c by means of suitable fasteners 4mm GI wire with adjustable cleats of 'J' hooks including making provn of housing light fitting etc all complete including cost of materials and labour T&P etc complete all as specified and directed. (Note :- Light fittings shall be measured and paid separately).
M&L for applying two coats of exterior emulsion paint over a coat of primer including preparation of newly plastered surfaces of walls.
M&L preparing the newly plastered surfaces and applying two coats of oil bound distemper over a coat of primer on walls.
M&L for excavating in post holes each n exc. 0.5 cum in soft/loose soil, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers n exc. 25cm, watering and removing surplus soil to distance n exc50m and making good surface.
M&L for plain cement concrete 1:2:4 type B-2 (using 40 mm graded aggregate ,in posts complete all as specified and directed.
M&L for joist, channel, angle, or tee sections, fixed independently, without connecting plates, etc. (cut to ordinary lengths i.e. within 20 mm of the length indicated) confirming to Fe-410-W Gde-E-250 quality A.
M&L for Plates (plain or chequered Fe 410-W (Gde E-250), Quality A, channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment complete all as specified and directed
M&L for roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc confirming to Fe-410-W Gde-E-250 quality A.
M&L for rolled sections as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates
S&F mild steel bolts purpose made with hexagonal or square head one end and screwed the other, or screwed both ends; each screwed end to be fitted with washers and one hexagonal or square nut, exc 30 cm long, neck diameter exc 20 mm not exc 25 mm.
S&F pre-printed galvalume aluminum zinc coating GI based corrugated steel sheeting of 0.50 mm thick fixed with self tapping screw with washers as roof covering.
All as per Srl Item No. 42 here-in-before but plain sheet on ridges fixed with screw with washers on roof.
S&F plain, galvanised, mild steel sheeting, in ridges, hips, valley gutters, drip and straight flashings (length and girth as fixed) with grade of zinc coating 275g/Sqm
S&F 110 mm bore PVC (SWR) Soil, waste and vent pipes single socketed in any length with rubber ring joints fixed to walls complete all as specified and as directed.
S&F in repairs 110 mm bore PVC (SWR) bends complete all as specified and as directed.
M&L for preparing new steel surfaces of any description, not otherwise described, over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of primer of red oxide complete all as specified and directed
M&L for hard core of gauge n exc 63 mm, deposited, spread and levelled in layers n exc 15cm thick, watered and rammed to a true surface.
M&L for 100 mm thick plain cement concrete type C-2, 1:3:6 (using 40 mm graded granite stone aggregate) in sub base flooring/plinth protection
M&L 25 mm thick plain cement concrete, type B-1, 1:2:4 (using 20 mm graded aggregate) as in sub base of floor, finished even and smooth without using extra cement
M&L 15 mm thick screed bed or bedding layer of mortar for laying tiles in cement mortar 1:4
M&L vitrified ceramic tiles 10 mm thick square/ rectangular) polished ultra charged, area of each tiles exceeding 0.36 sqm but not exceeding 0.42 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match all as per specified and directed
M&L granite 18-20 mm thick (of any type) tiles machine cut in skirting/ dado/ cladding/ tread and riser of stair case laid over 10mm thick cement mortar 1:3 and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including cutting and polishing
M&L for rounding to edges of granite 18-20 mm thick stone slabs one edge,such as in steps,cooking platform, and other similar situations
Surface excavation in soft/loose soil n exc 30 cm deep and averaging 15 cm deep and getting out complete.
M&L for 100 mm thick plain cement concrete type D-2, 1:4:8 (using 40 mm graded granite stone aggregate) in sub base of flooring/ hard standing
M&L sand filling under floors or in foundation including watering and consolidation.
M&L 60 mm thick M-35 machine pressed precast concrete coloured interlocking pavor block any shape and size confirming to IS-15658-2006 using with grey cement and pigment.
M&L for 15mm thick screed bed or bedding layer in cement mortar 1:4 for laying floor tiles
M&L chequered designed cement concrete tiles of size 300mmx300mmx20mm thick, with grey cement and pigment set, jointed and pointed in neat cement slurry in floor.
M&L 75 mm thick plain cement concrete 1:3:6 type C-2 (using 40 mm graded stone agg) as in flooring/plinth protection/sub-base finishing concrete surface even and smooth without using extra cement.
S&F glass dividing strips, 3mm thick 38mm width inserted in position confirm to design
M&L for providing plain cement concrete 1:2:4 type B-1 (using 20 mm graded aggregate) in copings/benching and other similar works all as specified and directed
M&L for 15mm dia of bore galvanised steel tubes, medium grade with all fitting and fixed complete to walls ceilings and or laid in floors complete all as specified and directed.
S&F PVC connections 15mm size with PTMT nuts of length 450mm complete all as specified and directed
M&L for 15mm dia of bore stop valves, fancy type, chromium plated, screwed pressure, with crutch of butterfly handle, screwed both ends for iron pipe for unions and fixed complete all as specified and directed.
S&F 15mm pillar taps, cast copper alloy, with capstand heads, chromium plated, screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly-nuts, screwed for iron pipe and fixed to 15 mm size pipe complete all as specified and directed.
S&F PVC waste pipe 32mm dia complete all as specifed and directed.
S&F sinks with drainage board made of stainless steel 1mm thick kitchen or laboratory with plugs, washers and waste; including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe overall size 915mm x 460mm bowl size 410mm x 330mm x 160mm complete all as specified and directed.
S&F waste coupling of PTMT 32mm size (half or full threaded) suitable for urinals and wash basin (minimum weight 32mm-45gms complete all as specified and directed.
S&F in repairs of 100mm Cast iron floor trap, with grating including jointing to waste pipe fixed in cement concrete type B-1 (1:2:4).
S&F grating doom 100mm dia of PTMT (Minimum weight 25 gms) complete all as specified and directed.
S&F in repairs rotational moulded polythene water storage tanks, multi layered 1000 Ltrs capacity (cylindrical, vertical with closed top) hoisted and fixed in position all as specified in SSR Part I.
S&F in repairs 25 mm bore dia ball brass valves, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed.
S&F in repairs gun-metal, globe or gate valves of 25mm bore dia, with iron wheel head, screwed both ends for iron pipe and fixed.
M&L for moorum/red bajri filling in floors or pavings, laid in layers n exc. 15 cm thick, spread, levelled and rammed including watering
S&F 12mm thick toughned & frosted glass with etching and frosting as per design for glass partition/door fixed with necessary screws, sealent, stainless steel patch,and all fittings etc complete with all stainless steel hardware used as per site requirement and complete all as specified and directed Note:- Unit rate to be deemed to include for cost of all materials & labour and no other item shall be measured and paid separately.
M&L for providing and fixing stainless steel (Grade 304) railing made of hollow tubes,channels, plates etc., including welding, grinding, buffing, polishing and making curvature (where ever required) and fitting the same with necessary stainless steel nuts and bolts complete, including fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of floor or the side of waist slab with suitable arrangement.
Holes drilled up to exc. 25mm and n exc.40mm dia if tapped in addition (with standard or gas thread, as directed) and depth of hole Exc 25 mm but n exc 40 mm
Taking down old unserviceable/deteriorated batten/PVC conduit point wiring from existing place i.e. light, fan, socket or power points complete with all unserviceable fittings such as switches, sockets, ceiling rose, pendants, Holders, etc and making good all disturbed surface to wall, floor etc by means of cement mortar (1 : 3) or plaster of Paris and to match / finish new surface as the existing surface either by using same colour distemper, Putty or white / colour wash all as required and directed by Engineer-in-Charge at site.
Taking down MCB DBs including MCB TPN / SPN /SP etc.complete all as specified and as directed.
S&F double door metallic sheet metal enclosure for DB when MCBs to be used TPN 4 ways, 415 V with 200Amps rated bus bar complete fixed properly on in concealed position and to provide required sizes of flexible conduit at any open surfaces near DBs of cables/wires complete all as specified and as directed.
S&F double door metallic sheet metal enclosure for DB when MCBs to be used SPN 8ways, 240 V with 200Amps rated bus bar complete fixed properly on in concealed position and to provide required sizes of flexible conduit at any open surfaces near DBs of cables/wires complete all as specified and as directed.
S&F in repairs, testing and commissioning of MCB TPN 415 volt 63 amp 10 KA capacity having C-curve characteristics connected with suitable lugs complete all as specified and as directed.
S&F in repairs, testing and commissioning of MCB SPN 240 volt 6 Amp to 32 amp 10 KA capacity having C-curve characteristics connected with suitable lugs complete all as specified and as directed.
S&F in repairs, testing and commissioning of MCB SP 240 volt 6 Amp to 32 amp 10 KA capacity having C-curve characteristics connected with suitable lugs complete all as specified and as directed.
S&F modular AC box (white) plug and 3 pin socket two in one, all in one type, SPN box with one single pole MCB 25Amp, 230 volts complete all as specified and as directed.
M&L sub main wiring on surface with 2 runs of single core PVC-FRLS insulated unsheathed multi stranded copper conductor cable of size 6 sqmm drawn in MS/ /PVC conduit ( ISI Marked) of size not less than 20 mm dia with 1 run of 6 Sqmm PVC-FRLS insulated unsheathed multi stranded copper conductor as a continuous earth wire complete in concealed / surface wiring inclusive all fitting such as tee, bends, reducer, elbow, bell mouth, tube ends and all fixing accessories such as couplers lock, nuts, saddles, pipe hooks etc. fixed properly including taking down old unserviceable sub main wiring complete all as specified and as directed. Note :- (i) Two runs of 6 sqmm and one run of 6 sqmm cable along with PVC conduit will be measured as one length
M&L for modular concealed point wiring on wall and surface wiring on ceiling/roof with necessary fixing arrangements with multi stranded PVC-FRLS insulated and unsheathed copper multi stranded conductor of size 1.5 Sqmm, 1100 volts grade drawn in and including rigid non metallic white / ivory PVC conduit medium grade ISI marked not less than 19 mm dia with all conduit accessories/ fittings such as junction boxes, bends, tee, elbow etc including anodized MS sunken boxes made out of MS sheet of thickness as per manufacturer design with earth dolly and Grid,Crown and cover Plate for fixing of modular switches / sockets, fan regulators with captive screw including PVC-FRLS insulated and unsheathed copper multi stranded conductor of size 1.5 Sqmm, 1100 volts grade for continuous earthing including cutting the chases and making good the surface by cement mortar (1:3) and for matching / finishing of new surfaces either by means of plaster of paris/ Putti or distemper / colour wash with same existing colour surfaces all as specified and directed by Engineer-in-Charge. For one light, fan, call bell point, 5 amps Socket on Independent Board controlled by one switch complete all as specified and as directed Make of Modular Accesories: Havells ( Crabtree)/Anchor(Woods)/Legrand
All as per item No. 89 here-in-before but for power point wiring with 4 Sqmm PVC-FRLS insulated, unsheathed, copper conductor, multi stranded 1100 volt grade cable
S&F Modular switch single pole one way 5/6 Amps, 240 volts, white finish complete all as specified and as directed.
S&F Modular switch 15 Amps, 240 Volts single pole white finish complete all as specified.
S&F Socket outlet 5 pin, 5/6 amp Modular type white finish complete all as specified
S&F Socket outlet 5 pin, 16 amp Modular type white finish complete all as specified
S&F ceiling rose, surface backlite, 65 x 20 mm three terminal complete all as specified and as directed.
S&F ceiling fan 1200 mm sweep complete with down rods & accessories w/o regulator 230 V single phase including required fixing arrangements and electrical connection , three core copper cable from ceiling rose to light fitting complete all as specified and as directed.
S&F in repairs Modular electronic socket size, rotary, 5 speed step type regulator, 120-230 V white finish complete all as specified and as directed.
S&F wall mounting fan oscillating type 400mm sweep, 900 RPM, 230 volts single phase
S&F down lighter 10 watt recessed in false ceiling 230 volts single phase
Supply, fixing and connecting exhaust fan, steel body AC single Phase. 230V, of size 300mm sweep with, blades, 900 RPM and frame and louvers complete all as specified and as directed.
M&L for making circular holes suitable for fixing of 12” sweep Exhaust fans by cutting the wall any thickness/ required circumstances for exhaust of air and including grouting of rag bolts and nuts complete including finishing of disturbed surfaces by using cement mortar 1:3 complete all as required at site and directed.
S&F of LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete watt cool white including connecting up with suitable copper cable of three core 1 Sqmm white coulor PVC insulated cable flexible type complete all as specified and as directed.
S&F in repairs LED security light with high energy saving LED, powder coated pressure die cast aluminium housing specially designed specular anodized super high purity, faceted alumnium reflector of size 35 watt, 230 volts complete all as specified and as directed.
S&F in repairs GI Bracket made out of 25 mm dia medium grade GI tube up to 0.90 m long bend to shape 115 degree off set shape, fixed with 2 nos of suitable MS Flat clame of size 25x4 mm with necessary nut bolts & washers and applying two coats of aluminum enameled paint over one coat of zinc oxide primer for clamp complete all as specified and as directed.
S&F AC single phase Static Energy meter of accuracy class 1.0, 240 v, 50Hz with backlit LCD Display of rating 10-61A (Measures & Displays kWh, kVAh, V, I, kW, PF, last month history of kWh &MD in KW) with special features like TOD, tamper logging, optical communicatio Port & Display in absence of Power with transparent Hinge type box. complete conforming to IS: 13779 as specified and directed.
Supply, installation,commissioning of water cooler fully stainless steel, electric driven single phase having approx storage and nominal cooling capacity of 40 ltrs
S&F voltage stabilizer for automatic operation of capacity 1 KVA, single phase neutral air cooled indoor type and designed for input variation between 175V to 250 volt and output voltage stabilizer between 215 V to 240 V with accuracy of + 2.5% all as specified and as directed.
S&F PVC connection 15 mm dia size with PTMT, 450 mm long with nut and bolt at both ends for hot and cold water complete all as specifie and as directed.
Supply, fixing, jointing and testing of 20 mm outer dia 3-layer PP-R Polypropylene random copolymer) concealed pipes SDR 7.4 (PN16) UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded polypropylene random fittings fixed complete to walls, ceilings or in floors etc. including all fittings complete all as ditected.
Supply, fixing, jointing and testing of 20 mm bore PP-R Gate valves (brass insert) complete allas specified and as directed.
M&L for earthing complete with M.S. galvanized earth plate electrode (600 x 600 x 6) mm thick buried directly in ground (earth pit not less than 2.25 M deep below normal GL) with top edge of the earth plate not less than 1.5M below normal GL, connected to galvanized earth lead wire 4 mm dia by means of bolts, nuts, check nuts & washers of GI or steel incl excavation, PCC (1:3:6) type C-1 chamber with RCC cover (1:2:4) type B-0, 40 mm thick reinforced with 6 mm dia bar, 3 Nos. both way, 15 mm dia light grade GI protection pipe, funnel with wire mesh,watering pipe of size 20 mm dia med. grade, lugs, main Earthing lead upto 7.5 mtr incl. Charcoal dust, salt etc. all as shown in electrical plate No. 3 of SSR Pt-I, 2009 specification.
M&L for XLPE insulated, LT armoured electric cable with aluminium standared conductor 1100 volts grade, cross-sectional area 16 sqmm, 4 core laid in trenches/pipes/ducts/wall/boarings with necessary cable lugs and glands,nuts,bolts and washers etc. and testing complete all as specified and directed. Note :- Excavation, earth work, cable protection, sand fillings, cable joint shall be measured and paid separately under respective items of schedule.
Excavation in trenches soft/loose soil not exceeding 1.5 mtr wide and not exceeding 1.5mtr in depth for foundation etc or for shaft well, cesspits, manholes, fire hole etc n.exc 10 sqm on plan and not exceeding 1.5mtr in depth and getting out complete all as directed.
Returning filling in soil including spreading leveling watering and well rammimg in layer n exc 25 cm complete all as specified and directed
Removing excavated soil not exc 50 mtr and depositing where directed at a level not exc 1.5 mtr above the starting point all as specified and as directed
M&L for dry river washed and screened dry sand for filling and spreading in trenches below and around the cable for cushioning including punned down as specified in relevant clause of SSR Part I. 2010 complete all as specified and as directed.
Supplying and laying un-reinforced precast concrete cable cover, class HV type 1, flat, size 250 mm x 150 mm x 40 mm complete all as specified and as directed.
SRI VENKATA SAI MANIKANTA CONSTRUCTIONS
JAHNAVI ASSOCIATES
HARSHA CONSTRUCTIONS AND ENGINEERING WORKS
VENKATA SHIVA RAJENDRA PRASAD ARAVALA
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .