Loading…
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Tender Value
₹15.8 L
EMD Value
₹16,000
Closing Date
28 Jan 2026, 12:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
EXECUIVE ENGINEER, Capital Project Electrical Division, Gandhinagar
Providing Lift in Gujarat Environment Management Institute,Sector 25,Gandhinagar. [3rd attempt]
265821
21/01 OF 2025/2026
Open
Electrical
Works
Gandhinagar
12 documents required · 12 mandatory
₹900
Yes
Executive Engineer, Capital Project Electrical Division, Gandhinagar.
₹16,000
Yes
17 Jan 2026
17 Jan 2026
17 Jan 2026
28 Jan 2026
17 Jan 2026
Name of work :- Providing Lift in Gujarat Environment Management Institute,Sector 25,Gandhinagar.
Fund Head:- Deposited
Place:- Gandhinagar
Item Quantity Particulars Issue Rate Amount
Signature of Contractor Deputy Executive Engineer
C.P.Electrical Sub Division
Executive Engineer
C.P.Electrical Division
Name of work :- Providing Lift in Gujarat Environment Management Institute,Sector 25,Gandhinagar. [3RD attempt]
Sr. Qty. Units Item of work Net Rate Rate in word Per Amount
1 1 Nos Supplying, Erecting, Testing & Commissioning the passenger / stretcher MRL lift having following 1575617.17 Rupees Fifteen Lakh Ea.
main features:[1] GEAR LESS LIFT DRIVE comprising of High Starting torque Lift 3 phase 440 V A. Seventy Five Thousand
C. Permanent Magnet Synchronous motor of proper rating with high efficiency shall be used.[2] Six hundred Seventeen
Micro processor based / PLC, ACVVVF, vector control drive with encoder feedback closed loop and Seventeen paisa
system shall be used for lift car and door operation which shall be full collective selective operation only
hall call demand response, UP/DOWN hall stops, Main, Up/ Down Contactor with overload and
phase reversal relay and safety controls.[3] Car with M S platform with bracings of adequate size
and to sustain the impact load cabin + passenger with safety factor of fire for steel and side panels
of Stainless steel of sheet of grade 304 duty. Car ceiling will be S.S. finishes with aesthetic
appearance with LED ceiling lights. Car flooring shall be of anti skid PVC with choice of colour of
engineer in charge. Car doors shall be of stainless steel grade 304, hairline finish with centre
opening / telescopic automatic doors. Car panel will also be S.S. 304 finished with emergency stop
device, mechanical door safety device, facility of auto/ attended mode. All car panel buttons and all
floor switches must be with brail language as per lift act.[4] All landing doors must be fire rated for
hour shall be fully automatic centre opening/ telescopic opening made of hairline finish steel grade
of 304 with key holes and infrared curtains with Unlocking facility from outside [5] Appropriate
battery operated emergency light in the car along with alarm switch shall be provided.
Also, Emergency Light & Fan should start immediately without any Time Delay as soon as power
fails.[6] Digital scrolling indicator system for up-down arrow along with floor position indicator shall
be provided inside the car and at all floors.[7] Full height infra red curtain with multiple cross /
crossing light beams shall be provided.[8] Automatic Rescue Device (ARD) shall be provided
accordingly of passenger capacity with Manual Rescue Operation ( Manual Cranking Facility).[9]
Audio visual indication in the lift car showing over loading shall be provided such that doors kept
open till excess load is removed.[10] Spring buffers/PU Buffers shall be provided.[11] Car fan as per
passenger capacity with automatic sleep timer shall be provided.
[12] Voice annunciator with suitable music shall be provided in lift car.[13] Self diagnostics system
for operational and safety parameters shall be provided in control panel.[14] Mechanical over speed
governor with governor calibration as per actual site parameters and submission of calibration
certificate submission, door key holes in the floor doors, fireman switch shall be provided.[15] Lift
machine hoisting arrangement in the lift machine room and monkey ladder for lift pit should be
provided by the lift agency, along with the other steel structure works, foundations for the machine
etc.[16] In the hoist way fascia plate shall be provided without any extra cost, where ever required
as / if directed by engineer in charge.[17] Permanent wiring with necessary safety devices like
RCCB in all circuit, Over Voltage Under Voltage protection and THD eliminator in circuit for lift
Sr. Qty. Units Item of work Net Rate Rate in word Per Amount
and lift well with proper numbers of light points, with fixtures, exhaust fan and plug points shall be
provided by the agency. Only 3 phase Power Supply shall be made available by department in lift
machine room. Necessary Earthing as per Lift Act/Rules shall be arranged by Lift Agency.[18] Any
civil/ electrical works for additional and alteration in lift shaft and machine room related to erection of
lift shall be made by lift agency without any extra cost. (granite/marble fixing around all landing door
openings are not in lift agency’s scope.)[19] Agency has to provide all working drawings and
documents and liaison services for obtaining all necessary permission from lift inspector and other
authorities. [20] acrylic transparent licence/display A4 size holder in lift car[20A] As per statutory
requirement of Govt. Of Gujarat lift & escalator act 2000, lift agency has to provide 1. Car top safety
barricade2. Push & talk communication system.3. Fireman's switch operation at Ground Floor.
4.carrying out third party lift inspection during/after lift erection and provide report by third party
authorized by concern licensing authority5.agency has to provide third party insurance upto
completion of free maintenance period and submit the document for the same.[21] Car Panel
Operating Buttons with floor position indicator/buttons must be of Auto Glow type clearly visible
when view from inside cabin.[22] For Physically Handicapped person Full Length Handrails of
hairline finish steel grade of 304 should be provided at appropriate height on the Rear & Side Wall
Panels in Lift Car.Special features for premium catagory:
1. Advanced control system dual 64 bit embedded microprocessor with CANBUS Serial
Communication mode including Regenerative power efficient operation,on site programming facility,
Anti nuisance, Pte-opening, BMS/RMS with necessary online real time monitoring system having
necessary connectivity for remote monitoring & other suitable supporting hardware & software
devices to fulfil the purpose.2. Floor Indication LCD Display with call registration & brail mark with
arrival gong and hall lantern & TFT Screen in the car with MP3 Voice Announcer.3. CAR Panel
should be Scratch resistive SS Moonrock finish / Hair Line / Honeycomb for car and all Doors, All
landing doors must have fire rating up to 2 hours and car door must have multi-level crisscross
beam door protection. 4. To & fro communication system & wiring (i.e. car , control room & guard
room ) and Each elevator are equipped with remote monitoring system.agency has to provide
mobile app and user id and password for monitoring. (S) 8 / 10 Passengers, Ground plus 3 upper
floor with Rated Speed of 1.0 m/sec.,(C) With General PLUS ADDITIONAL SPECIAL FEATURES
attached herewith. Prem. Cat.
Rupees Fifteen Lakh Seventy Five Thousand Six hundred Seventeen and Seventeen paisa only Amount Put to tender Rs.
Deputy Executive Engineer Executive Engineer
C.P.Electrical Sub Division 21 C.P.Electrical Division
Gandhinagar Gandhinagar
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
RAW_HTML
AMC.pdf
G S T LTR.pdf
GR.pdf
NOTICE NO 21 - 2025-26.pdf
PERFOMA-FORM.pdf
Specification.pdf
SBD Document.pdf
Latter of Transmital.pdf
PQ.pdf
SCHEDULE A AND B.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .