Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹19.4 LAccepted-AOC 26 1 BINDABAN PAL LANE KOLKATA 700003 | KOLKATA | KOLKATA | WEST BENGAL | 700003 | L1 | Accepted-AOC L1 | |
| 2 | L2₹20.1 L+₹69,447 (3.57%)Rejected-Finance 230 S N ROY ROAD KOLKATA 700038 | KOLKATA | KOLKATA | WEST BENGAL | 700038 | L2 | Rejected-Finance QUOTED SECOND LOWEST AMOUNT | |
| 3 | L3₹20.5 L+₹1.1 L (5.55%)Rejected-Finance 2 BOSE PARA ROAD BARISHA KOLKATA WEST BENGAL 700008 | KOLKATA | WEST BENGAL | 700008 | L3 | Rejected-Finance QUOTED HIGHEST AMOUNT | |
| 4 | Rejected-Technical | - | Rejected-Technical TECHNICALLY DISQUALIFIED |
Tender Value
Refer Docs
EMD Value
₹45,000
Closing Date
27 Jul 2021, 5:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
THE GENERAL MANAGER NORTH WBTDCL
GENERAL MANAGER NORTH WBTDCL MAINAK TOURIST LODGE COMPLEX MALLAGURI DARJEELING 734003
BEAUTIFICATION OF COMPOUND AREA WITHIN THE TOURISM PROPERTY PREMISES BY USING NON CONVENTIONAL ENERGY SOURCE SOLAR INCLUDING SUPPLY INSTALLATION TESTING AND COMMISSIONING OF WHOLE SYSTEM AT BHORER ALO TOURISM PROPERTY IN THE DISTRICT OF JALPAIGURI
2021_WBTDC_334830_5
10/WBTDCL (North) of 2021-22
Open Tender
Miscellaneous Works
Item Rate
20 days
BHORER ALO TOURISM PROPERTY GAJOLEDOBA
Please refer Tender documents.
3 documents required · 3 mandatory
₹0
₹45,000
Yes
16 Sept 2021
13 Jul 2021
30 Jul 2021
13 Jul 2021
27 Jul 2021
13 Jul 2021
30 days
Amount
BOQ SL NO. 5 Beautification of Compound area within the Tourism Property premises by using Non-Conventional Energy source- Solar incl. Supply, Installation, Testing and Commissioning of whole system at Bhorer Alo Tourism Property, Gajoldoba in the dist. Of Jalpaiguri.
Supply of Solar Photovoltaic Panels.Mono Crystalline 50Wp (Each) (Make: Iysert/equivalent) The PV modules used must qualify to the latest edition of IEC PV module qualification test or equivalent BIS standards Crystalline Silicon Solar Cell Modules IEC 61215/IEC 61730.The rated output power of any supplied module shall have tolerance of +/- 3%.The peak-power point voltage and the peak-power point current of any supplied module and/or any module string (series connected modules) shall not vary by more than 2 (two) per cent from the respective arithmetic means for all modules and/or for all module strings, as the case may be.The module shall be provided with a junction box with either provision of external screw terminal connection or sealed type and with arrangement for provision of by-pass diode. The box shall have hinged, weather proof lid with captive screws and cable gland entry points or may be of sealed type and IP-65 rated.
Supply of Module Mounting Structure: Hot dip galvanized MS Pipe may be used for mounting the modules/ panels. Each structure should have angle of inclination as per the site conditions to take maximum insolation.The mounting structure steel shall be as per latest IS 2062: 1992 and galvanization of the mounting structure shall be in compliance of latest IS 4Structural material shall be corrosion resistant and electrolytically compatible with the materials used in the module frame, its Jbolt, nuts and bolts.Thiknes of Galvanization shall be more than 85µ and windstand should be more than 150KM/hr. Aluminium structures also can be used which can withstand the wind speed of respective wind zone. Necessary protection towards rusting need to be provided either by coating or anodization.The minimum clearance of the structure from the roof level should be 300 mm [Design to be approved by EIC before fabrication].
Supply of 1 Nos. PV Array Junction Box (AJB): a) The junction boxes are to be provided in the PV array for termination of connecting cables. The Boxes (JBs) shall be made of Powder Coated Aluminium /cast aluminium/M.S alloy with full dust, water & vermin proof arrangement. All wires/cables must be terminated through cable lugs. The JBs shall be such that input & output termination can be made through suitable cable glands.b) Each Junction Box shall have High quality Suitable capacity Metal Oxide Varistors (MOVs) / SPDs, suitable Reverse Blocking Diodes. The Junction Boxes shall have suitable arrangement monitoring and disconnection for each of the groups. Voltage: Max. 1000V DC [Make: Hensel/Spielberg/ABB/L & T/IYSERT/AVO].
Supply of ACDB : Designed for .5KWp solar power plant with all protections as per MNRE guidelines. DC DPBs shall have sheet from enclosure of dust & vermin proof conform to IP 65 protection. The bus bars are made of copper of suitable size. Suitable capacity fuse & MCBs/MCCB shall be provided for controlling the DC power output to the PCU along with necessary surge arrestors . AC Distribution Panel Board (DPB) shall control the AC power from PCU/ inverter, and should have necessary surge arrestors. Interconnection from ACDB to mains at LT Bus bar while in grid tied mode.All switches and the circuit breakers, connectors should conform to IEC 60947, part I, II and III/ IS60947 part I, II and III. All the Panel’s shall be metal clad, totally enclosed, rigid, floor mounted, air - insulated, cubical type suitable for operation on three phase / single phase, 415 or 230 volts, 50 Hz.All indoor panels will have protection of IP54 or better. All outdoor panels will have protection of IP65 or better. [Make: Hensel/Spielberg/Citel/ABB/L & T/IYSERT/AVO]
Supply of Hybrid Solar Inverter Rating: 0.75KW, 1Ph Inverter, Make: IYSER/AVO/Equivalent . Control : Microprocessor /DSP Capacity of Each Inverter: .75kW String Inverter .Nominal AC output voltage and frequency : 230V, 1 Phase, 50 Hz . Output frequency : 50 Hz . Max. DC input Power .5kW. Output Voltage Range - 180V - 230V AC. Grid Frequency Synchronization range : +/- 5 Hz. Ambient temperature considered : -20o C to 50o C. Humidity : 95 % Non-condensing. Protection of Enclosure :: IP-65(Minimum) for outdoor. Grid Frequency Tolerance range : +/- 5 Hz. Grid Voltage tolerance : 180 V to 230 V. No-load losses : Less than 1% of rated power. Inverter efficiency(minimum) : >80%. . THD : < 3%. Efficiency Measurement IEC 61683/ Equivalent BIS Std.Environmental testing IEC 60068-2 (1,2,14,30) / Equivalent BIS Std.Interfacing with utility grid IEC 61727. Islanding Prevention Measurement IEC 62116. EMI/EMC : IEC 61000-6-3>16 Amps IEC 61000-6-4<16 Amps. Safety: IEC - 62109-1 (2010/4) C - 62109-2 (2011/6). All above IEC’s should be from NABL/ IEC Accredited Testing Laboratories or MNRE Approved Test Centers/ International laboratories.
Supply of 12V 150AH Solar Tubler Battery
Supply of Earthings System : Each array structure of the PV yard should be grounded/ earthed properly as per IS:3043-1987. The array field, PCU, ACDB and AJB should also be earthed properly. Earth resistance shall not be more than 5 ohms. It shall be ensured that all the earthing points are bonded together to make them at the same potential. At least 4 nos ground pipe / plate electrod as per PWD schedule for system earthing with soil treatment & earth inspection pit and GI flat of suitable size & quantity should be considered [Make: SGI/OBO/Beterman/Gmax].
Operation and maintenance for 3 years incl. warranty period.
Installation, Testing and commissioning Supply of Civil material for foundation with 7feet dia and 3feet height.Supply of Cable lug, Gland, tie and ferrule etc. Installation of whole system with testing commissioning
switching avo Electro Power Ltd
Rajalakshmi Enterprise
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .