Tender Value
₹65.9 L
EMD Value
₹1.3 L
Closing Date
12 Sept 2025, 2:00 pmClosed
Chief Engineer and DCE NFC
Chief Engineer DCE Nuclear Fuel Complex ECIL Post Hyderabad 500062
Providing VRF VRV AC System for ZFP first Floor Cabins and Renovation of AC system at CFFP(A) NFC Hyderabad
2025_NFC_875309_1
63089
Open Tender
Machineries/ Mechanical Engg Items
Item Rate
Hyderabad
Please refer Tender documents.
6 documents required · 6 mandatory
₹0
₹1.3 L
Yes
13 Sept 2025
30 Aug 2025
13 Sept 2025
30 Aug 2025
12 Sept 2025
5 Sept 2025
31 Aug 2025 - 4 Sept 2025
Amount
Supply & installation including Lifting shifting & transportation of VRF/VRV Outdoor machines for air conditioning system, based on variable refrigerant flow-R410a, comprising of one or more variable output compressors (Inverter Scroll type), condenser coil & fins provided with special anti-corrosive treatment, necessary accessories for oil separation, moisture removal, flow control, interconnecting piping, condenser air fan, electrical and microprocessor based panel, interconnecting cabling, all housed inside a weather-proof cabinet suitable for exposed installation on terrace. The panel must be 100% compatible with BMS. The unit/s provided with self-addressable control system for control of indoor & other outdoor machines. The capacity & power consumption curves deration / correction factor curves / charts for indoor temperature and piping derations must be submitted with offer, along with duly filled up data sheet in the attached format. The combination of ODUs should be in a way to achieve more than 3.6 COP at 100% capacity, and maximum 2 ODU / compressor models. OEM Suggested suitable MCBDB for each unit in the scope of contractor. Filter sections with Fine Filters (95 to 99% down to 5 Micron) Approved make : Carrier/Voltas/Daikin/Hitachi/equivalent NOTE: The entire project 's Scaffolding requirements fall under the contractor's scope of work
Supply: 18.0 HP VRF Outdoor Unit
Erection: 18.0 HP VRF Outdoor Unit
Supply & Installation including Lifting Shifting & transportation of Indoor machines of Ceiling Suspended Air Handling Unit with AHU expansion Kit – 8 TR capacity, double skin construction with 25 mm PUF insulation, high-efficiency EC plug fan suitable for 80 mmWC external static pressure, DX cooling coil with copper tubes and aluminium fins, VRF compatible, airflow 2500–2800 CFM, G4 pre-filter, SS-304 insulated drain pan, vibration isolators, and hinged access panels. , quoted price to include all controls, valves & necessary accessories required to connet the IDU to the copper piping. rigging to respective locations, installation, testing, commissioning of indoor units, supply of mounting arrangement to be considered in the rate. Approved Make: Carrier/Voltas/Daikin/Equivalent
Supply:
Erection:
VRF INDOOR UNITS (IDU): Supply, installing, testing and commissioning of Cassette VRF/VRV type unit complete with return air grill and remote control . Outdoor unit consisting of hermetically sealed rotary compressor,necessary safety devices, adequate capacity of air cooled condenser,all mounted on M S Frame and enclosed with a weather type enclosure to protect the electrical circuit and fan winding The indoor unit consists of evaporator fan capable of developing min static pressure,copper refrigerant piping with insulation (not exceeding 9m for each unit) connecting indoor and outdoor units and wired & wireless both type remote controller, includes necessary accessories for fixing and mounting etc all complete as required. The installation to include the breaking and making good walls for refrigerant piping with insulation, indoor to outdoor cabling and wiring to nearest power source as per site conditions. Cost shall include drain pump and necessary arrangement. SITC of Metal MCB sockets for each IDUs. Approved Make: Carrier/Voltas/Daikin/equivalent
Supply: 2 TR
Erection: 2 TR
Supply: 1.5 TR
Erection: 1.5 TR
Copper pipe with Insulation: Supply, installation, testing and commissioning of refrigerant gas & liquid piping using eddy current free Copper pipes and fittings like elbows, couplers, tee joints, required Refnet joints, brass fittings, "U" loops, expansion loops etc. Supports consisting of GI box / "C" sections & female anchor fasteners with full threaded GI rods, insulation of suction / liquid pipes using 25 mm thick elastomeric closed cell Nitrile Rubber insulation material having class "O" for fire properties along with protective coating as per specifications, structural clamps with hard PVC pipe sleeves under the clamps to protect insulation at supports, tagging to enable tracing connectivity to respective units as per shop drawings to be generated by contractor and approved by consultant. Submission of test reports in approved format forms a part of this item scope
Supply
Erection
Nitrogen Pressure testing & Additional gas charging for the entire length of copper pipes - Refrigerant R410A / Environmental friendly refrigerant.
Supply
Erection
Supply & installation of CPVC pipe of with 6mm thick nitrile rubber insulation and necessary supports and fixing accessories etc.
Supply : 25mm
Erection: 25mm
Supply : 40mm
Erection: 40mm
Supply : 50mm
Erection: 50mm
SITC of hot dipped galvanised perforated cable tray of 1.6 mm thk. and 100 mm height. The width of the cable tray shall be as under. All required supports, fittings, bends, offsets, bolt & nuts, etc. shall be included. This cable tray is meant for laying the copper piping inside the building the building.
Supply :300 mm width
Erection:300 mm width
Supply :150 mm width
Erection :150 mm width
STRUCTURAL FABRICATED STEEL WORK: : Supply, Fabrication , Cutting, Welding , Erection at site and painting of M. S. Angle structural steel work for required truss, AHU/ODU /Supporting structurer/etec. & as per site requirements, etc. based on the approved drawings. The work should be carried out as per good manufacturing and installation practices in concurrence with approved drawings. The structural steel materials should confirm to IS : 2062 (latest version) as per drawings. All welding electrodes to confirm to relevant IS codes. Fabrication and erection of the structural steel works shall be as per IS: 800 and welding work as per IS:816 and IS: 822. Finally all steel work to be painted with one coat of zinc chromate primer and two coats of Metal primer paint.
Supply
Erection
Communication cable for VRF 1.5x3 core with shielded cable with PVC conduits
Supply
Erection
Control Cable: 2C x 1.5 sq mm shielded Copper control cabling with saddles/ supports & PVC conduits to connect outdoor units with respective indoor units & remote controller units. Shield to be grounded on both ends for each circuit.
Supply
Erection
POWER CABLES: 3C x 4 Sq mm FR LS armoured Copper Cable For :Supply, Installation, Testing & Commissioning of BIS Certified FRLS , PVC insulated Armoured Copper Power Cables of suitable ratings/sizes between the distribution board, AHU, ERV and Condensing Units and Interlocking etc., including lugs, crimping and terminations identifying labels duly clamped.
Supply
Erection
Supply, Installation, Commissioning and Testing of Supply wire between indoor unit to the socket
Supply
Erection
Dismantling of Old Package AC Units and Shift to AC Maint Section
RCC Civil work:Reinforced Cement Concrete (R.C.C) 1:1.5:3 by insitu mixing using Weigh Batching or RMC of Grade M-20 using Ordinary Portland Cement(OPC) conforming to IS 269 or Portland Pozzolana Cement (PPC) conforming to IS 1489 Part-1 with Minimum Cementitious Content not less than 320 Kg/Cum (M/s. ACC,Ultra Tech, Raasi, Birla, Coromandal, Andhra Cements Ltd. make) with crushed stone sand and graded stone aggregates of 20mm maximum size at all depths/heights below/above plinth level including consolidation, finishing smooth/broom finish as applicable, curing, etc., Wall breaking, closing, plastering etc to run duct as per site required and complete as specified and directed.
Fresh Air Tecnologies (BID ID -3279947)
ETA Engineering Pvt Ltd (BID ID -3281176)
A GOVERDHAN (BID ID -3279092)
stage.html
html • 0.02 MB
finance_920167.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .