Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Infra Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹66.9 LAccepted-AOC 13 29 304 3RD FLOOR EAST PATEL NAGAR OPP SIDDHARTHA HOTEL NEW DELHI 08 | NEW DELHI | NEW DELHI | DELHI | 110008 | L1 | Accepted-AOC Being lowest | |
| 2 | L2₹67.6 L+₹62,147 (0.93%)Rejected-Finance 61 ABHAY GARH SCHEME AIR FORCE JODHPUR 342001 RAJ | JODHPUR | JODHPUR | RAJASTHAN | 342001 | L2 | Rejected-Finance Being Not Lowest | |
| 3 | L3₹68.5 L+₹1.6 L (2.37%)Rejected-Finance SHIV BARI ROAD NEAR KASUMAL HOTEL BIKANER 334003 RAJASTHAN | BIKANER | BIKANER | RAJASTHAN | 334003 | L3 | Rejected-Finance Being Not Lowest | |
| 4 | L4₹71.7 L+₹4.8 L (7.14%)Rejected-Finance 10 ABHAY GARH SCHEME CENTRAL SCHOOL AIR FORCE JODHPUR 342001 RAJ | JODHPUR | JODHPUR | RAJASTHAN | 342001 | L4 | Rejected-Finance Being Not Lowest | |
| 5 | L5₹73.0 L+₹6.1 L (9.04%)Rejected-Finance 0 NEAR SHIV MANDIR KALYANIPURA KRIPAL NAGAR AJMER RAJASTHAN 305001 UDYAM RJ 01 0091182 | AJMER | RAJASTHAN | 305001 | L5 | Rejected-Finance Being Not Lowest |
Tender Value
₹77.7 L
EMD Value
₹1.4 L
Closing Date
12 Dec 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE AF JODHPUR
HQ CWE AF JODHPUR 342011 Rajasthan
PROVN OF STANDBY POWER SUPPLY FOR REGIONAL RADIO NETWORK MANAGEMENT CENTRE BUILDING (TROPO) AT AFS MANDORE JODHPUR
2023_MES_627073_1
86053/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE AF NO 2 JODHPUR
As per NIT
8 documents required · 8 mandatory
₹1,000
GE AF NO 2 JODHPUR
₹1.4 L
Yes
12 Feb 2024
6 Nov 2023
19 Dec 2023
6 Nov 2023
12 Dec 2023
27 Nov 2023
Amount
Supplying, installing, testing & commissioning of factory assembled Diesel Engine driven generating set including acoustic enclosure as per current CPCB norms automatic mains faillure panel fully wired alternator AC to give an output of 250 KVA /200 KW ,continuously rating at a PF of 0.8 lagging, 415 volts , AC 3 phase 4 wire 50 HZ ,1500 RPM, directly coupled with diesel engine water cooled mounted on common base frame complete with floor mounting fuel tank (service tank) of adequate capacity with fuel line & accessories, PCC foundation work as per manufacturer's instructions, vibration damper pads & other accessories etc comprising of following:- Diesel engine : Water cooled turbocharger of suitable BHP at 1500 RPM confirming to BS 5514 & ISO 3046 with an overload capacity of 10 % for one hour in any 12 continuous hours operation and designed and tested for 50°C ambient temperature with standard fittings. Alternator:-250 KVA alternator, 3 phase, Power factor:- 0.8, Rated generating voltage:- 230/415V, screened protected, revolving field, self excited, self regulated through an AVR, the alternator has following features:-(i) 'H' class insulation (ii) IP23 protection with insulation class H (iii) +/- 1.0% voltage regulation (maximum) in static condition (iv) permissible overload of 10% for one hour in 12 hours of operations Control Panel : Control panel is manufactured with 14/16 gauge CRCA sheet and is powder coated for weather-proof and long lasting finish. including the following:- PowerCommand Controller Aluminum bus bars with suitable capacity with incoming/ outgoing terminals Indicating lamps for ‘Load ON’ and ‘Set Running’ Instrument fuses duly wired and ferruled MCCB of suitable rating with overload and short circuit protections AMF panel AMF Panel outdoor type, 250 KVA DG Set with alluminium busbar of capacity 500 Amps, TPN powder coated (coloured ) heat shrinkable sleeves, 3.15 mm CRCA sheet steel enclosure duly powder coated and inbuilt on load change over switch of 400Amps consisting the following:- INCOMING from 250 KVA (i) MCCB 400 Amp FP 35 KA - 01 No (ii) Spreaders 400 Amps FP - 01 Set (iii) Extended Rotary handle 400 Amps FP - 01 No (iv) Earth fault module - 01 No (v) Power Contactor 400 Amp FP AC1 Duty with 2 NO and 2 NC Aux block coil voltage 220 Volts AC - 01 No (vi) C.T. 250/5A CL-1.0 10 VA - 03 Nos (vii) Digital MF meter 96 x 96 mm with 485 Port CL 1.0 - 01 No (viii) Indicating lights (Red-4, Yellow-2. Green-2) (ix) Control MCB 6A SP 10 KA C curve (x) VMR - 01 No (xi) In built on load change over switch 400 A for bypassing of AMF panel - 01 No Outgoing (i) MCCB 400 Amp FP 35 KA - 01 No (ii) Power Contactor 400 Amps FP AC1 Duty with 2 NO and 2 NC Aux block coil voltage 220 V AC - 01 No (iiI) AMF relay (iv) SMPS 12V, DC, 10A - 01 No (v) Emergency stop P.B - 01 No (vi) Digital Amp meter 12, DC - 01 No (vii) Digital Volt meter 12V, DC - 01 No (viii) Control MCB 6A SP 10 KA C Curve (ix) Hooter - 01 No(x) PROCOM UNIT (DGC6D) FOR control - 01 No Acoustic Enclosure : Powder coated weather proof canopy. Engine and alternator mounted on AVM mounts, with silencer and SS exhaust below optimised to meet stringent CPCB norms for sound and emission, Baserail with drawout type fuel tank, drain plug, inlet and outlet connections, airvent, level gauge etc.PCC Plateform : size as per OEM recommendation Batteries : Volts and AH as per OEM.
Supply laying and testing XLPE insulated screened PVC bedded, galvanized steel strip or wire armored heavy duty 11000 Volts grade with stranded aluminium conductor 95 Sqmm 3 core complete all as specified and as directed.
Supply & jointing cable jointing kit for 11 KV (Earthed) grade cable for indoor termination cold shrinkable type joint complete with jointing material & accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 Sqmm complete all as specified and as directed.
Supply & jointing cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination cold shrinkable type joint complete with jointing material & accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 Sqmm complete all as specified and as directed.
Supply, laying, testing and jointing of cable XLPE insulated screened PVC beaded, galvanized steel strip or wire armoured, electric power cable (heavy duty) with aluminium stranded conductor, 1100V grade of size 300 sqmm 3.5 core complete.
Supply, laying, testing and jointing of cable XLPE insulated screened PVC beaded, galvanized steel strip or wire armoured, electric power cable (heavy duty) with aluminium stranded conductor, 1100V grade of size 120 sqmm 3.5 core complete.
M & L for construction of cable duct with bricks & cement and fine finishing by cement mortar of ratio 1:5 for running UG cable including RCC cover with handle, Excavation complete all as specified and directed
Material and labour for earthing complete with galvanized steel earth plate electrode 60cmx60cmx6mm thick, buried directly in ground, vertically to a dpeth not less than 2.25 mtr deep below ground level with top edge of the earth plate at depth not lss than 1.5 mtr below ground level earth plate surrounded by 15 cm thick and packed layers of charcoal, dust and common salt, earth lead GI strip 32 x 6mm by means of bolts, nuts, check-nuts and wahsers of galvanised iron and thimbles and of earth wire protected by galvanised iron pipe light grade 40mm bore and water pipe 20mm bore GI medium grade with funnel and wire mesh complete 1:3:6 type C-1 using 20mm graded stone aggregate in lieu of CI cover and frame etc all as specified and shown in electrical plate No 3 of SSR- 2009 (Part-1)
Material & Labour for Chemical Earthing complete with copper earth plate electrode 90cm x 60cm x 5mm thickness burried directly in ground (earth pit not less than 2.5mtr deep below normal ground level) with top edge of earth plate not less than 1.5 mtr below normal ground level connected to and incl copper strip 32x6mm by means of nuts & bolts, check nuts and washers of brass made of copper and connected to test point and earth dolly al as shown in electrical plate no 3 SSR part I 2009 ans specified or indicating including providing charcoal dust 100 kgs ,common salt 150 kgs ,magnisum sulphate 200 kgs and all around the plate 15CM depth and wide upto 650mm height in continuous layer ,balance pit will be filled with vegaetable soil upto groundlevel including excavation and earth work in any type of soil PCC (1:3;6) type C1 in chamber ,precast concrete (1:2:4) type B1,reinforced with welded steel wire fabric or XPM weight not less than 4 Kg/Sqm with cast iron frame ,funnel with wire mesh 40 mm bore light grade GI watering pipe all as specified and testing on completion.(Note:- the earth resistance should be less than one ohms and GI protection pipe and earth lead more than 7.5 RM shall be measure and paid separately)
Supply and installation ,Testing and commossioning of 250 KVA ,ISOLATION Transformer ,double wound core type ,three phase,50 hz,mineral oil cooling IS 335/1972 , normal HV supply voltage 415 V ,phase to phase ,NO load voltage ratio of 415/415 V complete all as specified and as directed.
Supplying and laying synthetic Rubber insulated mats 2.5 mm thick for voltage upto 11 kv for electrical purpose as per IS 15652-2006, (superseding IS 5424) suitable for electrical shock safety of sizes 2m x 1m complete all as specified and as directed.
M& L for taking down existing RMU 3 way ,630 Amps including all assessories and cables from position after disconnecting incoming and outgoing connections and shifted/installed carefully where as directed in cantonment area including PCC foundations as suitable and directed by Engr in charge.
S & F double wall corrugated (DWC) high density polythene pipes having corrugation on the outer wall and plain surface on the inner wall confirming to ISI 14930 (Part I and II) for protection of underground cable having outer dia of pipe 100 mm with all fitting laid in trenches/ road/ nallah or fixed along wall, poles or laid under floor for cable protection all as specified & directed. Note : Road cutting/floor cutting /cutting holes etc in walls required for laying/fixing of cable etc shall be made good as per existing. Nothing extra shall be admissible on this account. Quoted rates shall be inclusive of the above provisions.
PCC 1:4:8 type D-2 using 40 mm graded crushed stone aggregates as in foundation of poles etc filling and mess concrete complete all as specified.
PCC 1:2:4 type B-1 using 20 mm graded crushed stone aggregates as in foundation of poles etc filling and mess concrete complete all as specified.
M & L for precast cable route indicator made out of cement concrete 1:2:4 type B1, using (20mm graded stone aggregate) having 15 cm square shape at top and 30 cm square shape at bottom and total height of 100 cm febricated as per direction of Engeer-in-charghe and grouted into PCC 1:2:4 type B1 as per site requirement including embossed with HT 11 KV cable end LT cable 1100V at 50 meters in synthetic enamel paint red coloured and necessary excavation and earth work in any type of soil as directed by Engineer-in-charge.
SANJOLI CONSTRUCTION COMPANY
M/s Rohit Construction Co.
RISING ELECTRICALS
M/S JAGDAMBA ENTERPRISES
Shri Electrical Enterprises
SHISHODIA ENTERPRISES
Vijaypower Generators Limited
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .