Loading…
New: tenders and results on WhatsApp
New: Find tenders, results and companies on WhatsApp, by text or voice note
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹36.9 LAccepted-AOC | L1 | Accepted-AOC L1 Bidder | |
| 2 | Rejected-Technical | - | Rejected-Technical Not Qualified | |
| 3 | Rejected-Technical | - | Rejected-Technical Not Qualified |
| Sl No | Description | Qty | Unit | METRO ELEVATOR CO PVT LTD L1 |
|---|---|---|---|---|
| 1.00 | Earth work in excavation manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.
All kinds of soil.
Note: Excavation need to be done Manually as per site conditions and as directed by Engineer-in- charge. | 30.67 | Cum | 500 ₹15,337 Lowest |
| 2.00 | Earth work in excavation manual means beyond 1.5 m or part thereof in excavation in foundation trenches or drains including dressing of sides and ramming of bottoms, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.
All kinds of soil. | 4.87 | Cum | 600 ₹2,924.4 Lowest |
| 3.00 | Providing and laying in plain cement concrete of specified grade including the cost of centering and shuttering - All work up to plinth level :1:3:6 (1 Cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources). | 4.78 | Cum | 5,000 ₹23,900 Lowest |
| 4.00 | Providing and laying in position ready mixed or site batched, design mix or nominal mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete.
Concrete of M25 grade with minimum cement content of 330 kg /cum. Complete in all respect as directed by EIC.
NOTE: M25 (1 : 1 : 2 i.e. 1 cement : 1 coarse sand(zone-III) derived from natural sources : 2 graded stone aggregate 20 mm nominal size derived from natural sources), Complete in all respect as directed by EIC. | 11.61 | Cum | 15,000 ₹1,74,150 Lowest |
| 5.00 | Centering and shuttering including strutting, propping etc. and removal of form for Foundations, footings, pedestals, bases of columns, lift pit walls etc. for concrete. Complete all as per specifications or in all respect as directed by the EIC. | 55.01 | Sqm | 3,500 ₹1,92,542 Lowest |
| 6.00 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete up to all level Thermo-Mechanically Treated bars of grade Fe-500D or more. Complete in all respect as directed by EIC. | 1,154.4 | Kg | 110 ₹1,26,984 Lowest |
| 7.00 | Structural steel work in frames, covers, roofs using tubular section (round, square or rectangular hollow tubes etc.) tees, flats, bars, chequered plates, inserts fabricated out of mild steel bars, angles, pipes, plates, foundation bolts etc. of all shapes, sizes including supplying, cutting, fabricating, welding, erecting, making holes/ chases wherever required and fixing / embedding in position in concrete/ masonry work with necessary hold fasts/ screws & rawl plugs and finishing the concrete / masonry work after fixing / embedding including painting two coats of synthetic enamel paint of approved make and colour on all surfaces over a coat of approved steel primer etc. complete as per specifications, drawings and as directed by the Engineer in charge.(YSt-310 steel grade / as per approved drawings, as directed by EIC) . | 8,053.75 | Kg | 180 ₹14,49,674.82 Lowest |
| 8.00 | Providing and fixing 12mm thick frameless toughened glass Cladding / door shutter of approved brand and manufacture, including providing and fixing arrangement and making necessary holes, supporting pins/hinges etc. for fixing required Cladding/ door fittings, all complete as per direction of Engineer in charge. (Door handle, lock and Stopper etc.to be paid separately).
Note: Cladding work of LIFT Shaft shall be completely leak proof. | 76.39 | Sqm | 3,800 ₹2,90,282 Lowest |
| 9.00 | Demolishing brick work in cement mortar manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material outside IPR campus lead as per direction of Engineer-in-charge.
Work shall be done with out damaging other parts of the building and services except designated part by EIC. Complete for all heights and all leads as directed by the EIC.
Note: The quoted rate shall be inclusive the cost of Scaffolding as required to complete the work. | 6.57 | Cum | 3,000 ₹19,716 Lowest |
| 10.00 | Demolishing Cement Concrete, stone flooring manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material out side IPR campus as per direction of Engineer - in- charge.
Work shall be done with out damaging other parts of the building and services except designated part by EIC. | 3.61 | Cum | 5,000 ₹18,035 Lowest |
Tender Value
₹38.4 L
EMD Value
₹76,862
Closing Date
8 Apr 2025, 3:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Dean (Admin)
Institute for Plasma Research (IPR), Near Indira Bridge, Bhat, Gandhinagar-382428
Construction of Lift Shaft, SITC of Six Person Passenger Lift and Structural Steel Staircase for Emergency Exits at G plus 2 Guest House building in IPR, Bhat, Gandhinagar.
2025_IPR_848570_1
IPR/TN/CIVIL-PR/01/2025
Open Tender
Civil Works - Buildings
Item Rate
210 days
IPR Campus, Bhat, Gandhinagar
As per Tender Documents
8 documents required · 8 mandatory
₹0
₹76,862
10 Sept 2025
13 Feb 2025
11 Apr 2025
13 Feb 2025
8 Apr 2025
6 Mar 2025
13 Feb 2025 - 26 Feb 2025
Amount
Earth work in excavation manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil. Note: Excavation need to be done Manually as per site conditions and as directed by Engineer-in- charge.
Earth work in excavation manual means beyond 1.5 m or part thereof in excavation in foundation trenches or drains including dressing of sides and ramming of bottoms, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil.
Providing and laying in plain cement concrete of specified grade including the cost of centering and shuttering - All work up to plinth level :1:3:6 (1 Cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources).
Providing and laying in position ready mixed or site batched, design mix or nominal mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete. Concrete of M25 grade with minimum cement content of 330 kg /cum. Complete in all respect as directed by EIC. NOTE: M25 (1 : 1 : 2 i.e. 1 cement : 1 coarse sand(zone-III) derived from natural sources : 2 graded stone aggregate 20 mm nominal size derived from natural sources), Complete in all respect as directed by EIC.
Centering and shuttering including strutting, propping etc. and removal of form for Foundations, footings, pedestals, bases of columns, lift pit walls etc. for concrete. Complete all as per specifications or in all respect as directed by the EIC.
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete up to all level Thermo-Mechanically Treated bars of grade Fe-500D or more. Complete in all respect as directed by EIC.
Structural steel work in frames, covers, roofs using tubular section (round, square or rectangular hollow tubes etc.) tees, flats, bars, chequered plates, inserts fabricated out of mild steel bars, angles, pipes, plates, foundation bolts etc. of all shapes, sizes including supplying, cutting, fabricating, welding, erecting, making holes/ chases wherever required and fixing / embedding in position in concrete/ masonry work with necessary hold fasts/ screws & rawl plugs and finishing the concrete / masonry work after fixing / embedding including painting two coats of synthetic enamel paint of approved make and colour on all surfaces over a coat of approved steel primer etc. complete as per specifications, drawings and as directed by the Engineer in charge.(YSt-310 steel grade / as per approved drawings, as directed by EIC) .
Providing and fixing 12mm thick frameless toughened glass Cladding / door shutter of approved brand and manufacture, including providing and fixing arrangement and making necessary holes, supporting pins/hinges etc. for fixing required Cladding/ door fittings, all complete as per direction of Engineer in charge. (Door handle, lock and Stopper etc.to be paid separately). Note: Cladding work of LIFT Shaft shall be completely leak proof.
Demolishing brick work in cement mortar manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material outside IPR campus lead as per direction of Engineer-in-charge. Work shall be done with out damaging other parts of the building and services except designated part by EIC. Complete for all heights and all leads as directed by the EIC. Note: The quoted rate shall be inclusive the cost of Scaffolding as required to complete the work.
Demolishing Cement Concrete, stone flooring manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material out side IPR campus as per direction of Engineer - in- charge. Work shall be done with out damaging other parts of the building and services except designated part by EIC.
Demolishing R.C.C. work manually/ by mechanical means including cutting, stacking of steel bars and disposal of unserviceable material out side IPR campus as per direction of Engineer - in- charge. Work shall be done with out damaging other parts of the building and services except designated part by EIC.
Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and including stacking of serviceable material within IPR campus and disposal of unserviceable material out side IPR campus as per direction of EIC: Of area 3 sq. metres and below. Work shall be done with out damaging other parts of the building and services except designated part by EIC.
Providing & Grouting of Columns/foundations bolts/ base plates/ dowel tubes / Shear keys / Joints of precast members with GP2 cementitious grout (Non Shrink) of approved make by suitable means ( Free flowing /pump),curing etc. Complete as per directions of Engineer-in-charge. (The payment shall be made on the basis of actual weight of approved grout injected.) Stirrer mixed cementitious grout (non shrink) of approved make in column/foundations bolts/ dowel tubes / Shear keys / Joints of precast members.
Providing and laying of 12 mm Cement Plaster of mix:1:4 (1cement:4sand),Complete in all respect as directed by Engineer-In-Charge. Note: The Plaster should be of single coat Smooth Mala finished.
Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound ) content. With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre. Complete in all respect as directed by EIC.
Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. Two coat or More. Complete in all respect as directed by EIC.
Supplying and filling in plinth, any other locations with sand under floors, including watering, ramming, consolidating and dressing complete. Complete in all respect as directed by EIC.
25 mm thick Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing, rough complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand). Complete in all respect as directed by EIC.
Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete. On concrete work: Complete in all respect as directed by EIC.
Providing and fixing fire resistant door frame of section 143 x 57 mm having built in rebate made out of 16 SWG G.I. sheet (zinc coating not less than 120 gm/sqm) duly filled with vermiculite based concrete mix, suitable for mounting 60 minutes fire rated door shutters. The frame is fitted with intumescent fire seal strip of size 10x4 mm (minimum) all-round the frame and fixing with dash fastener of approved size and make, including applying a coat of approved brand fire resistant primer and powder coated finish etc. Complete as per direction of Engineer-in-charge
Providing and fixing 50 mm thick glazed fire resistant door shutters of 60 minutes fire rating conforming to IS:3614 (Part-II), tested and certified as per laboratory approved by Engineer-in-charge, with suitable mounting on door frame, consisting of vertical styles, lock rail, top rail 100 mm wide, bottom rail 200 mm wide, made out of 16 SWG G.I. sheet (zinc coating not less than 120 gm/m2) duly filled Fire Resistant insulation material (rock wool /mineral wool ) and fixing with necessary stainless steel ball bearing hinges of approved make, including applying a coat of approved fire resistant primer with powder coated finish, including all necessary items, vision panels (size 200 mm x 300 mm, 6 mm glass) etc. all complete as per direction of Engineer-in-charge.
Providing and fixing panic bar / latch (Double point) fitted with a single body, Trim Latch & Lock on back side of the Panic Latch of reputed brand and manufacture to be approved by the Engineer- in- charge, all complete.
Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer (as per IS code : 3564 / relevant IS code, suitable to single leaf fire door), with double speed adjustment with necessary accessories and screws etc. complete. Approved by the Engineer- in- charge, all complete.
Constructing brick masonry chamber for underground C.I. inspection chamber and bends with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg), R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 fine sand : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement: 3 coarse sand), finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design. Inside dimensions 500x 700 mm and 45 cm deep for pipe line with three or more inlets : With common burnt clay F.P.S. (non modular) bricks of class designation 5.0, Complete in all respect as directed by EIC.
Extra for depth beyond 45 cm of brick masonry chamber
Supplying, assembling and fixing in any position, unplasticized PVC medium well casing (CM) pipe of required dia, conforming to IS: 12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer -in-charge. 150 mm nominal size dia.
Supplying Installation, Testing & Commissioning of lift having contract speed 1 MPS serving different floors in the lift shaft as per detailed specifications enclosed and as under: Note:- The building is (G+2) A. Basic Door Operation : Auto Classification: Passenger Lift Machine Room less-Gearless with Belt Number of Passengers: 6 Rated Load : min 408 Kg Control: Microprocessor Based Controller With VVVF Operations: Down Collective Speed (m/s): 1.0 Number of Stops: 3 Floors Served Front 3 No Of Opening 3 Floor marking G, 1, 2 Power Supply 400 Volts 3 Phase 50 Hertz A. C. Light Supply:230 Volts,50 Hertz Single Phase Machine Room: N/A Car Entrance Type: Opposite Side
B. Dimensions Door Width : min 700 mm Door Height : min 2000 mm Shaft Width : min 1500 mm Shaft Depth : min 1500 mm Lift Car Width : min 1000 mm Lift Car Depth : min 1100 mm Lift Car Height: min 2200 mm Travel Height : G+2 Building Pit Depth : As per IS Standard Headroom : As per IS Standard Shaft Details M.S. Structure as per design and along with Toughened Glass cladding. C. Car & Landing Details Car Door Type: Automatic Center Opening Big Vision Car Door Finish : Stainless Steel- Hairline Landing Door Type :Automatic Center Opening Big Vision Landing Door Finish :Stainless Steel Hairline at all landings Landing Door Frame: Stainless Steel Hairline at all landings Car Panels - Shade / Finish Transparent Glass with Stainless Steel Frame False Ceiling Stainless Steel- Hairline False Ceiling - Shade / Finish LED Panel Lights Car Ventilation- Blower Flooring- PVC tiles Handrail: SS mirror finish handrail on left side & right side (38 mm to 50mm dia)
LOP: Touch COP: Touch Display In COP: 7 Segment D. Standard Control Functions / Features Digital Floor Position Indicator in Car and at all floors - Yes Door Sensor -Yes Door Open/Close Buttons In COP-Yes Alarm Button In COP (With Battery Back-Up)-Yes Emergency Light In Car-Yes Intercom- Between Car & Ground Floor Auto Rescue Device In Case Of Power Failure-Yes Auto/Attendant operation-Yes Auto/Manual Fan and Lights On/Off -Yes Voice Announcement system - Required Providing and fixing Photo luminescent signage boards - as per standard/as directed by EIC. Power Supply: Supply, installation, testing, fixing of Supply of 3-Phase and 1-Phase Power (Rating of switchgears and cables to be provided by the contractor as per Original Equipment Manufacturer (OEM) requirement) Supply in the lift shaft along with placing Bulkhead Light fixtures, any other accessories and Sockets and Switches at each floor. Scope of work is also including supply of material (i.e. MCB, RCCB, Cables, DB, etc.) and installation of the same.
Earthing System: Supply, installation, testing, commissioning of 2 nos. Copper earthing system & 2 run of 25x3 mm electrical grade cu. Earthing strip up to Electrical installation, associated accessories, etc complete in all respect for the lift as per IS:3043. Earth Resistance value will be measured after installation and the same should be less as per relevant standard/lift inspector. Complete in all respect as per specifications and as directed by EIC. NOTE: 1. The Lift shall be installed in a structural steel shaft with toughened glass cladding as per relevant IS (with latest amendment). 2. Structural Steel & Toughened Glass for cladding of Shaft only shall be measured separately and paid in the respective item of Tender.
Designing and submission of Architectural and Structural drawings of Structural steel staircase and Structural steel lift shaft for installing 6 person capacity passenger lift for a G+2 building, from an AMC/ GMC approved qualified Structural Engineer, including liasioning and obtaining Lift license/ NOC for operation of passenger lift, from statutory body, including preparing submission drawings (in .dwg / any other format as required) or modifying existing building drawings for submission and approval etc, complete, in all respect or as directed by EIC. Note: 1. The contractor shall submit the design drawing from structure engineer/ Architect to Institute for clearance before start of execution of work at site. Modification or suggestion if any shall be incorporated and revised drawing shall be submitted for clearance to Institute. 2. If Required, Existing Guest House building drawings shall be shared with Contractor. 3.Statutory fees for obtaining NOC from Lift Inspector/ statutory body shall be paid by Institute upon submission of challan from statutory body.
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .