ARC work of Attend the cable fault at site within 03 HRS from receiving the message from D.E OF concern S/DN AND Locating the Fault underground Cable for ALL scheme in the jurisdiction of Kim S/dn & any others sdn of KIM Division. Through outsourced agency for existing DGVCL Network for SDN under Kim Division.
320459
KIM/O&M/TECH/N-PROCURE/26-27/01/SR-48 DT:03-07-2026
Open
Electrical and Maintenance Works
Surat
5 documents required · 5 mandatory
3 Jul 2026
3 Jul 2026
3 Jul 2026
13 Jul 2026
3 Jul 2026
ARC work of Attend the cable fault at site within 03 HRS from receiving the message from D.E OF concern S/DN
AND Locating the Fault underground Cable for ALL scheme in the jurisdiction of Kim S/dn & any others sdn of
Item Code No. Description Unit Rate Amount
Labour charge for excavation of cable trench of 400mm width x Meter
1200mm depth, in any type of soil for laying of cable of size up to
1 9925000001 mm2 (For additional cable 200 mm additional width shall be considered
i.e. half trench length is to be considered
Labour charge for excavation of cable trench of 600mm width x Meter
1200mm depth, in any type of soil for laying of cable of size up to
2 9925000002 mm2 (For additional cable 200 mm additional width shall be considered
i.e. half trench length is to be considered
Labour charge for excavation of cable trench of 400mm width x Meter
1500mm depth, in any type of soil for laying of cable of size up to
3 9925000003 mm2 (For additional cable 200 mm additional width shall be considered
i.e. half trench leng th is to be considered
Labour charge for laying of 11kV / 22 kV XLPE Cable of size up to 240 Meter
mm2 & preparation of sand layer 100mm thick, in the cable trench &
covering the cable with 150 mm dia (Outer), thickness 25 mm,
meter long RCC half round muffs and providing and fixing of 4inch
4 9925000004 width yellow colour polyethylene tape with printing"CAUTION
ELECTRIC CABLE BELOW' at 0.75 m depth from ground surface after
laying cable in trench. This will provide indication that electric cable is
passing underground so as to protect cable from mechanical injuries,
refilling the same, as per Instruction of E gineer in Charge (EIC) .
Labour charge for horizontal drilling using Auger machine without Meter
damage to surface road at max 2.0 mtrs depth & putting of
kg/cm2 , class-4,Green color, 110mm 0.D. 8.5mm thickness H.D.P.E.
pipe confirms to IS 4984-1987(3rd revision) and BIS certification and
laying of 11KV/22KV XLPE cable of size up to 240 mm2 in HDPE pipe,
5 9925000005 as per Site Condition (excluding cost of pipe). The detail map obtained
from HDD machine and excel sheet hard and soft copy) indicating the
respective depth and distance from adjacent landmark for each
segment for HDD is must require to be submitted. HDD to be carried
out at depth 1.5 mtrs to 2.0 mtrs as per site conditions and as er
instruction of EIC.
File No: DGVCLDOKI/TND/e-file/6817/2026/3421/Technical
Approved By: Executive Engineer,Technical,DGVCLDOKI
Letter No: DGVCLDOKI/0075/07/2026 Approved Date: 03-07-2026 01:56
Labour charge for horizontal drilling manually without damage to Meter
surface road at max 2.0 mtrs depth & putting of 6.11 kg/cm2 , class-
4,Green color, 110mm O.D. , 8.5mm thickness H.D.P.E. pipe confirms
to IS 4984-1987(3rd revision) and BIS certification and laying of
11KV/22KV XLPE cable of size up to 240 mm2 size, as per Site
Condition (excluding cost of pipe). The detail map and excel sheet
(hard and soft copy) indicating the respective depth and distance from
adjacent landmark for each segment of cable to be submitted. Drilling
to be carried out at depth Minimum 1.2 mtrs to 2.0 mtrs as per site
conditions as per instruction of EIC.
Supply of 6.11kg/cm2 , class-4,Green color, 110mm O.D. , 8.5 mm Meter
7 9925000007 thickness H.D.P.E. pipe confirms to IS 4984 and BIS certification for
laying of underground 11KV/ 22KV XLPE cable up to 240 mm 2 size.
Labour work for RCC concreting on disputed location and repairing of CMT
8 9925000008 damage portion of road crossing for the work carried out for roads
crossing as well as concreting & muffing of poles including all materials
Providing & fixing concrete stone route marker of 300 mm width x 150 No
mm thick x 650 mm height embedded in earth at least 300 mm below &
350 mm above ground level respectively at distance approx. 50 meters
along the length of cable. The RCC concreting (1:2:4)(all necessary
materials will be in bidder's scope) of route marker is to be carried out
300 mm width x 150 mm thick x 300 mm below ground level as per
instruction of EIC. The route marker should be with name of company
with approved yellow colour-DGVCL. The distance from marker to
cable and cable depth with feeder name etc., marked with arrow sign is
to be painted on it. The route marker is to be fixed at location near to
any fixed permanent location (not necessary to fix exact on top of
cable) as per instruction of EIC.
Labour charge for erecting of 11kV / 22 kV XLPE cable of size up to perJob
240 mm 2 on DP Structure with fixing of 02 Nos polymer cleats on top
and middle part. Polymer cleats, nut bolts etc. fixing material to be
provided by contractor.
Providing & fixing of 6.11kg/cm2 , class4,Green color, 110mm O.D. perJob
8.5mm thickness H.D.P.E. pipe confirms to IS 4984 and BIS
certification on the erected DP structure for the mechanical protection
of cable by inserting the cable inside HDPE pipe. The HDPE pipe shall
be erected in such a way that 300mm shall be below the ground level
and the rest 2700 mm shall be supported on the DP Structure with
No Polymer cleat. All materials including polymer cleat and Nut bolt to
be provided by contractor.
Providing and fixing of pipe type earthing from 80 mm dia class-B GI No
pipe with pit to be filled with salt & coke and construction of chamber as
1 9925000016 per DGVCL Drg. No. dg /100 for DP and cable. The earthing pit should
be joined with cable by G.I. strip of size 1" width & 2 mm thick. All
material GI pipe, Coke Salt etc will be supplied by bidder.
Supply & fixing of heat shrink type end terminations (outdoor) for up to No
1 9925000017 11kV 3C x 185 mm2 size XLPE cable as per DGVCL technical s
Supply & fixing of heat & shrinkable end terminations (outdoor) for up No
2 9925000018 to 22 kV 3C x 185 mm 2 size XLPE cable ( as per DGVCL technical
Supply & fixing of heat shrinkable type end terminations (indoor) for up No
3 9925000019 to 11kV 3C x 185 mm 2 size XLPE cable as per DGVCL technical
Supply & fixing of heat & shrinkable end terminations (indoor) for up to No
4 9925000020 22 kV 3C x 185 mm 2 size XLPE cable as per DGVCL technical
Supply & fixing of heat shrinkable straight through joint for up to 11kV No
5 9925000021 3C x 185 mm 2 size XLPE cables as per DGVCL technical
File No: DGVCLDOKI/TND/e-file/6817/2026/3421/Technical
Approved By: Executive Engineer,Technical,DGVCLDOKI
Letter No: DGVCLDOKI/0075/07/2026 Approved Date: 03-07-2026 01:56
Supply & fixing of heat shrinkable straight through joint type for up to No
6 9925000022 22kV 3C x 185 mm 2 size XLPE cable as per DGVCL technical
Labour charge for excavation of 2100mm long x 1200mm wide x 1200 No
mm deep joint pits for installation of 11kV / 22kV Straight through joints
7 9925000023 as per instruction of engineer-in-charge & covering the cable with
mm dia (Outer), thickness 25 mm, 1.0 meter long RCC half round
muffs & refilling same as per instruction of EIC .
Providing and fixing of insulating bus bar, made from 11KV/22KV No
XLPE cable after removal of semi conducting layer and applying of
PVC heat shrinkable antitracking core insulating tubing (1.1KV), on
both end terminal using Aluminium long barrel heavy duty up to 240 sq
9 9925000024 mm lugs, Aluminium bus connector. Taping with PGclamp for bus
conductor as per drawing and as per instruction of EIC. The
Allurninium lugs and PG clamp shall be covered with 11KV/22KV HT
insulating tapes.(11KV/22KV XLPE cable will be in scope of DGVCL
while all other materials will be in bidder's scope.
Testing of cable at various points and commissioning the feeder as per No
8 9925000025 instruction of engineer-in-charge.Test result shall be submitted by
contractor with bill.
Preparation and submission of 6 (six) copies, of complete layout Set
11 9925000026 drawings with GIS mapping as per actual cable routing showing road
crossing, HDPE pipe sleeving, jointing locations, markers etc.
To Attend the cable fault at site within 03 hrs from receiving the No
9 9925000047 message from D.E of concern S/dn and locating the fault under ground
TOTAL AMOUNT :-Twenty Four Lacs Only 24,00,000/-
TOTAL AMOUNT :-Twenty Four Lacs Only 24,00,000/-
Executive Engineer (O&M)
DGVCL, KIM IND DIVISION.
File No: DGVCLDOKI/TND/e-file/6817/2026/3421/Technical
Approved By: Executive Engineer,Technical,DGVCLDOKI
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
RAW_HTML
2.1 Kim and any others sdn.pdf
2.2 N-procure.pdf
2.3 Kim and any others sdn.pdf
2.4 Kim and any others sdn.pdf
Schedule B Kim and any others sdn.pdf
Download all tender documents and submit your bid