Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹37.8 LAccepted-AOC 362 SUBHASH NAGAR PO CLEMENT TOWN DEHRADUN UTTARAKHAND | ₹37.8 L | L1 | Accepted-AOC AOC accepted |
| 2 | L2₹40.1 L+₹2.3 L (5.95%)Rejected-AOC FLAT NO C 401 LORD KRISHNA GREEN OPPOSITE DOON SCHOLAR SCHOOL KEDARPUR DEHRADUN UK 248001 | DEHRADUN | DEHRADUN | UTTARAKHAND | 248001 | ₹40.1 L+₹2.3 L (5.95%) | L2 | Rejected-AOC AOC rejected. |
| 3 | L3₹44.8 L+₹7.0 L (18.4%)Rejected-AOC UPPER SARTHI VIHAR AJABPUR KALAN PO NEHRUGRAM HARIDWAR ROAD DEHRADUN 248001 UK | DEHRADUN | UTTARAKHAND | 248001 | ₹44.8 L+₹7.0 L (18.4%) | L3 | Rejected-AOC AOC rejected. |
| 4 | L4₹45.4 L+₹7.6 L (20.0%)Rejected-AOC | ₹45.4 L+₹7.6 L (20.0%) | L4 | Rejected-AOC AOC rejected. |
| 5 | Rejected-Technical SHOP NO 5 OPP SHANI MANDIR PROFESSOR COLONY DISTT YAMUNA NAGAR HARYANA 135001 | YAMUNANAGAR | HARYANA | 135001 | - | - | Rejected-Technical Balance work more than twice the tendering limit. |
Tender Value
Refer Docs
EMD Value
₹96,880
Closing Date
23 Apr 2021, 6:00 pmClosed
GE DEHRADUN
GE DEHRADUN, GARHI CANTT, MALL ROAD, TELE - 01352750580
Repair/ maintenance of Electrical Fittings/ Fixtures, Ceiling Fan, Gyesers and Allied works in Birpur/ Ghunghora area of AGE E/M-I under GE Dehradun.
2021_MES_432942_1
8268/A/E8
Open Tender
Civil Works
Item Rate
240 days
GE DEHRADUN
Class D cat b(i)
8 documents required · 8 mandatory
₹500
GE DEHRADUN
₹96,880
Yes
2 Jul 2021
25 Mar 2021
26 Apr 2021
25 Mar 2021
23 Apr 2021
9 Apr 2021
Amount
Dismantling electric and water connection of the 25/50 ltr's geyser, taking down from its original position on ground, opening up and removing apparatus plate from the tank, descaling the geyser inner tank and apparatus plate complete, checking for defects, replacement of unserviceable parts such as heating element, syphon assembly, thermostat, rubber gasket etc., reassembling and installation of the geyser into its original position and connecting all electric and water supply connection and testing on completion all as directed by Engineer-in-Charge
(a) Inspection opening, dismantling, descaling, washing with chemical solution and cleaning of storage tank. (b) Checking water tightness of storage tank after cleaning at designed pressure. (c) Checking stopcock, pressure reducing valve etc to ensure free movement of their parts. (d) Replacing washers and glands of bib taps, stopcock and inspecting over flow vent pipe connections to ensure water-tightness and proper flow. (e) Checking and correct earth continuity of electrical items (f) Checking functioning and correct setting adjustment of thermostat (g) Adjustment of reducing valves, checking of dead weight type high pressure release valve and visual check of fusible plug for its intactness.
(h) The cost of fixing of parts under item No. 2 to 9 shall be deemed to be included in the unit rate quoted under item 1 by the contractor. Cost of parts shall be paid as supply only under respective items here under. (i) Nut, bolts and hold fastners if required to be replaced shall be deemed to be included in the quoted rates of this item. (j) All repairs shall be carried out on complaint basis. (k) The contractor shall collect the complaint slip from JE E/M by 1100 hrs daily. (l) Payment for a geyser will be made only once through out the contract period irrespective number of repair carried out in same Geyser.
Supply only heating element 1.5 KW 230 volts, ISI marked suitable for 25/50 ltrs geysers complete all as specified and directed by Engineer-in-Charge. Make :- Theeta/Bajaj/Recold.
All as per Srl item 2 herein before but 2.0 KW complete all as specified and directed.
Supply only syphon assembly for geyser any type of hole (6/7/9) all complete as per existing make & size as per site requirement all complete all as directed by Engr-in-Charge. Make:- Dashmesh/Theta/Newton/Bajaj.
Supply & fixing of indicator lamp for geyser of any type.
S&F plug top 3 pin 15 Amp in repair. ISI marked Make Anchor/ Cona/ Plaza
Supply only bottom cover of MS sheet 20 gauge suitable for 25 ltrs cap geysers and providing a coat of red oxide to inner surface and applying one coat of synthetic enamel paint by spray painting to outer surface complete all as specified and directed by Engineer-in-Charge.
Supply only thermostat for geyser long type 11" in length as per site requirement temp setting on 60 degree centigrade ISI Marked, complete all as specified and directed. Make: Dashmesh/Indofors/Donfoss/Bajaj
Supply only Apparatus plate for 25/50 liters capacity geyser made out of brass, chromium plated complete all as directed.
Supply only split plate for 25/50 ltrs capacity geyser as per site requirement and made out of 20 guage MS sheet duly painted complete all as specified and directed.
Supply only fusible plug made out of brass and lead complete all as specified and directed. Make : Dashmesh/Theta/Newton
S&F three core PVC insulated flexible and over all PVC round cable of size 40/0.0060 with multi stranded copper conductor complete all as specified and directed.
S&F in replacement of sheet metal enclosure single pole and neutral with 3 pin earth metal plug and socket complete with one single pole MCB 10 Amps, 240 volts (for geyser) complete all as specified and directed by Engineer-in-Charge. Make L&T, ABB, Legrand, GE
Supply only pressure release valve as per existing make and size geyser spring loaded 15 mm dia complete all as specified and directed.
Supply only rubber Gasket as per existing make/size site requirement suitable for 25/50 Ltr capacity geyser complete all as specified and directed.
S&F in replacement of Geyser vertical mount type 25 Ltrs capacity five star rated , shockproof and rust proof metal body compact size including two nos PVC connection heavy duty and connecting with all fixing arrangement of nuts & bolts and fixing on wall complete all as specified & directed . MAKE: BAJAJ, RECOLD,/ HAVELLS . ( Note: old unserviceable Geyser will be deposited in E/ M store yard )
S&F in replacement of sheet metal enclosure single pole and neutral with 3 pin earth metal plug and socket complete with one single pole MCB 20 Amps, 240 volts complete all as specified and directed by Engineer-in-Charge. Make L&T, ABB, Legrand, GE
S&F GI tubing medium grade 15 mm bore ISI marked, fixed on floor /wall complete all as specified including all fittings complete all as specified and directed.
M&L for painting of outer surface of 25/50 ltrs storage type water geysers after cleaning of dust & other organic/inorganic materials if any and applying one coat of synthetic enamel white paint by spray painting and writing MES No on the geyser complete all as specified and directed by Engineer-in-Charge.
S&F in repairs chromium plated brass bib cock 15 mm bore complete all as specified and directed.
S&F in repairs chromium plated brass non-return valve 15 mm bore ISI marked screwed both ends and connecting to iron pipe complete all as specified and directed by Engineer-in-Charge.
S&F in repairs brass stop cock chromium plated 15 mm bore ISI marked, screwed down high pressure with crutch handle, screwed both ends for iron pipe complete all as specified and directed by Engineer-in-Charge.
S&F in repairs chromium plated copper connecting pipe 450 mm long with nuts and rubber washers suitable for 15 mm bore pipe complete all as specified and directed by Engineer-in-Charge. Make:- Polo/Havells/Prayag
S&F in replacement of water supply PVC flexible connection Nylon braided with suitable threaded check nut with washer complete suitable for hot/ cold water 15mm dia alongwith threaded Brass nuts and washers 45 cm long complete all as specified and directed. Make:- Polo/Havells/Prayag
S&F in replacement of 3 core PVC insulated copper cable of size 40/0.0076 multi standard in repairs complete all as specified and directed by Engineer-in-Charge. Make Plaza, National, Shalimar.
Disconnecting electric connection and taking down of ceiling fan / Exhaust fan of any sweep complete carefully for overhauling, removing capacitor, split pins checking of bearings/bush, cleaning the fan blades with cleaning solution, replacing the unserviceable bearing, bush, capacitor , safety split pin and nuts, bolts, washer etc, cutting threading down rod if required, reassembling the ceiling fan complete after greasing/servicing, oiling testing the same making the fan in serviceable condition and refixing/ hanging the same complete all as specified and directed by Engineer-in-Charge (Note: Bush, bearing, capacitor, down rod, hanging clamps, will be paid under relevant item of this Schedule). Cost of split pins, nut bolts and threading of down rod pipe rates are included in quoted rate)
Cutting of all copper coils & taking out burnt/damaged wire from ceiling fan motor of any make and M&L for rewinding of ceiling fans motor of any make with super enameled copper winding wire of appropriate size same gauge as original incl packing insulating material soldering varnishing assembling and testing complete all as specified of the following sweeps:- Make of wire: Jyoti/
(a) 1200 mm sweep
(b) 1400 mm sweep
S&F standard ball bearing of ceiling fans of 1200/1400 mm sweep to suitable for different makes of fans of approved quality including necessary greasing complete all as specified and directed. Make : NBC-117 or SKF , NORE
Cutting of all copper coils & taking out burnt/damaged wire of exhaust fan motor of any make & M&L for rewinding of exhaust fans of 450 mm sweep with super enameled copper winding wire of same size, gauge & weight including varnishing & insulating complete all as specified and directed . Make of wire: Jyoti/
All as per Srl item No. 29 above but 380/350mm sweep
All as per srl item No. 29 above but PVC fresh air fan.
Cutting of all copper coils & taking out burnt/damaged wire of motor of the air circulator fan (Wall mounted/pedestal fan) of 450 mm sweep and M&L for ewinding of motor with super enameled copper wire of suitable/existing gauge including replacement of insulation tape, paper etc, varnishing and heat treatment complete and reassembling the motor and testing at desired RPM complete all as specified all as directed . Note : All ceiling fans/Exhaust fans/Cabin fans/Pedestal fan shall be repaired in MES Store yard.
S&F in replacement of old unsv armature shaft for ceiling fans of 1200/1400 mm sweep of any make complete all as specified.
S&F down rod 30 cms long made out of heavy grade M.S pipe with necessary threading at both ends holes as required with suitable matching colour of ceiling fan 1200mm/1400 mm as directed by Engineer-in-Charge
All as per Srl item No. 34 above but 60 cm long.
S&F rubber bushes and real type synthetic rubber with 14.5 mm hole suitable for fan hooks for hanging of ceiling fans.complete all as specified and directed.
S&F in repair nut bolts & washers with clamp with complete set of appropriate size for hanging of ceiling fan.complete all as specified and directed.
S&F in replacement blade made out of aluminium suitable for any make and sweep and colour of set of three ceiling fan as directed at site by Engineer-in-Charge.
S&F in replacement blade made out of aluminium suitable for any make and sweep and colour of exhaust fan as directed at site by Engineer-in-Charge.
S&F in replacement blade made out of aluminium suitable for any make and sweep and colour of cabin fan of any make and size of wall fan, table fan, pedestal fan etc.complete all as specified and directed.
S&F as in replacement and upper & lower canopy made of good quality PVC of required size complete set for ceiling fan with tightening screws complete all as specified and directed. .
S&F in replacement condenser/capacitor suitable for 230volts single phase ceiling fan/exhaust fan/cabin fan/pedestal fen incl necessary connection Make Asain//Usha/Baja) complete all as following capacity
M&L in replacement for providing three core 23/.0076 with copper conductor ceiling fan to ceiling rose and making connection complete all as specified and directed by Engineer-in-Charge. Make: Plaza, Finolex and Kalinga.
M&L for painting one coat of synthetic enamel paint by spraying to ceiling fans of any type in MES store yard including preparation to old painted surfaces by filling cavities etc complete incl making/writing of MES No all as directed by Engineer-in-charge. (Note: Painting of fans shall be done in MES stores Yard/Stores).
M&L for Painting of exhaust fans complete of any sweep in situ with synthetic enemel paint by spraying including filling cavities with filler one coat after cleaning solution dust/dirt/oil etc including writing MES No complete all as specified and directed
S&F exhaust fan frame made out of M.S sheet of any make and size of exhaust fan with suitable size of nuts, bolts & washers complete all as specified and directed. .
S&F in replacement of super quality louver made out of alumn for 450mm sweep exhaust fan of any make all as specified & directed.
All as per Srl item No. 47 above but for 300/380mm sweep exhaust fan complete all as specified and directed.
S&F fan hook split type fabricated out of 12mm dia steel bar of length 30cm duly painted with rod oxide old black paint complete all as specified and directed. .
S&F in replacement of ceiling fan 1200 mm sweep single phase 230 volts double ball bearing with down rod , canopy, blades etc BEE 5 star rated including connecting with twisted three cord flaxible copper conductor cable (23/.0076 ) from ceiling rose to connector of fan comlete all as specified and directed Make Havells/ Crompton/ Orient/ GEC.( Note: Old unserviceable ceiling fan will be deposited in E/M store yard. )
S&F in replacement of Air ventilation fan single phase 230V 300 mm sweep with louvers with provision of making hole as required size in existing wall and making good complete including connecting with three core 23/0076 copper wire from ceiling rose to fan complete all as directed. Make :- Havells/ Crompton/ Usha. ( Note: Old unserviceable fan will be deposited in E/M store yard. )
S&F in replacement of wall mounted fan oscillating type 400mm sweep single phase 230 Volt complete all as specified and directed.Make :- Havells/ Crompton/ Usha( Note: Old unserviceable fan will be deposited in E/M store yard. )
Taking down carefully copper/Aluminum point wiring (light, fan socket and power) complete including switches, ceiling rose lamp holder and regulator etc and removing from site and making good disturbed surfaces of walls floors etc. complete all as specified and directed by Engr-in-charge.
M&L for point wiring with 1.5 Sqmm (nominal area) two single core PVC insulated unsheathed multistranded copper conductor cable 1100 volts grade, FRLS grade in and including medium duty concealed PVC conduit 20 mm dia or higher and conduit fittings and all accessories with suitable size of pressed steel terminal box 1.2mm thick, duly painted for mounting of switches, sockets, fan regulator etc with 3 mm thick plastic laminated sheet as top cover, including continous earth wire PVC insulated, unsheathed, multi stranded copper conductor cable 1.5 sqmm (nominal area) FRLS grade, green colour, up to common earth and connected to earth dolly compete all as specified and directed by Eng.-in-charge of following. (Note: Colour code shall be maintained as per IE rule)
(a) One light point/ ceiling fan point/ Exhaust fan point controlled by one-one way switch.
(b) One bell point controlled by one-one way switch.
(c) One three pin 5 Amp socket on same board with other switches.
(d) One three pin 5 Amp socket on independent board
(e) One light point controlled by two two way switch
All as per item No. 54 above but one 3 pin socket outlet 15 Amp independent, cable 2.5 Sqmm Pvc insulated unsheathed multistranded copper cable FRLS for phase & neutral, with 2.5Sqmm PVC insulated unsheathed multistranded copper conductor cable FRLS as earth continuity conductor.
M&L for point wiring with 1.5 Sqmm. (nominal area) FRLS, two single core PVC insulated unsheathed multistranded copper conductor cable 1100 volt grade, FRLS grade in existing PVC / Steel, concealed conduit including MS box of thickness not less than 1.2mm for, mounting of switches, sockets, fan regulator etc including 3 mm thick bakelite hylam laminated sheet as top cover, one green colour FRLS cable of 1.5 Sqmm PVC insulated unsheathed multistranded copper conductor cable FRLS grade as earth wire up to common earth and connected to earth dolly compete all as specified and directed by Engr-in-charge . The wiring to be done as per IE rule and maintain colour code accordingly
(a) One light point /Ceiling fan point/ Exhaust fan point controlled by one-one way switch.
(b) One bell point controlled by one-one way switch.
(C) One three pin 5 Amp socket on same board with other switches.
(d) One three pin 5 Amp socket on independent board
(e) One light point controlled by two two way switch
All as per item No. 56 above but one 3 pin socket outlet 15 Amp independent, with 2.5 Sqmm PVC insulated unsheathed multistranded copper conductor cable FRLS as phase and neutral, with 1.5 Sqmm PVC insulated unsheathed multistranded copper conductor cable FRLS as earth continuity conductor.
S&F switch piano flush, button type 5 Amp SP 250 Volt AC complete all as specified & directed.
S&F switch piano flush button type 15 Amps SP 250 Volt AC complete all as specified & directed.
S&F socket outlet multipurpose 3 Pin 5 Amp and 2 Pin 5 Amps 250 V AC complete all as specified & directed.
S&F socket outlet 2-in1,3 pin 5 and 15 Amp flush type 250V AC complete all as specified & directed.
S&F Bell push flush, button type 5 Amp SP 250 Volt AC complete all as specified & directed.
S&F Bell Ding dong 250V AC complete all as specified & directed.
S&F switch piano flush button type 5 Amps two way SP 250 Volt AC complete all as specified & directed.
S&F ceiling rose surface bakelite 3 terminals of size 65x25mm complete all as specified and directed.
S&F step type, electronic fan regulator 120 watts, 5 step for ceiling fan 1200/1400 mm sweep 230 volts AC. complete all as specified and directed.
S&F lamp holder PVC/polycarbonate type with LED lamp 9/10 watt complete all as specified & directed.
S&F ceiling rose, 3 terminal/PVC/polycarbonate, isolated body 250 V AC complete all as specified and directed. .
S&F in relacement LED decorative post top lantern for Garden light 40 watt IP 65 protection resistance to impact and corrosion glare, free and better uniformity milky version as per CG cat part No LPTO40CDL/ Bajaj model No. BGCTW4LEDWW including taking down old unserviceable post of lantern.complete all as specified and directed.
M&L for sub main wiring with 2 Single core PVC insulated unsheathed cable 1100 Volts grade heavy duty copper conductor multistranded of size 10 Sqmm (nominal area) and one single core green colour PVC Insulated unsheathed cable copper conductor multistranded of size 10 Sq mm as earth wire upto common earth and connected to earth dolly drawing through in existing concealed conduit complete incl taking out old unserviceable submain all as specified & directed.
-do all as per Item No 70 but two 6 sqmm with 6.0 sqmm earthwire
M&L for sub main wiring with 2 Single core PVC insulated unsheathed cable 1100 Volts grade heavy duty copper conductor multistranded of size 10 Sqmm (nominal area) and one single core green colour PVC Insulated unsheathed cable copper conductor multistranded of size 10 Sq mm as earth wire upto common earth and connected to earth dolly drawing through and incuding PVC medium grade conduit 25 mm dia complete incl taking out old unserviceable submain all as specified & directed. Make: Havells/Finolex/L&T
-do all as per Item No 72 but two 6 sqmm with 6.0 sqmm earthwire
M&L in replacement for service cable 6 sq mm twin core weather proof aluminium multistranded conductor cable PVC sheathed PVC insulated hanging wire duly connected with earthing and clamp etc from Pole to pole complete all as specified and directed.
All as per item No 74 here in above but 10x2 Sqm.
Earthing complete with galvanized mild steel earth plate (electrode) 600 x 600 x 6.00 mm thick buried directly in ground, earth pit not less than 2.25 mtr deep below ground level surrounded with adequate quantity of charcoal dust mixed with salt to a packed thickness of 15 cm all round the plate using 4 mm dia GI wire as earth wire moulded and riveted to earth plate at one end and connected to main switch/control switch of the building at another end, GI earth wire incased in and including 15 mm dia GI ‘light grade’ pipe from upper end of earth plate uopto main switch/control of the building including 20 mm dia bore GI pipe ‘light grade’ as water pipe from earth chamber to upper edge of earth plate, CI funnel with wire mesh fixed on water pipe and provision of PCC chamber and RCC pit cover with lifting handle, excavation, earth work including laying the GI pipe concealed in floor /wall all as described in electrical plate No 5 of SSR Part I.
M&L for excavation in trenches n. exc. 1.5 mtr wide and n. exc. 1.5 mtr in depth for laying of underground cable, foundation of pole and getting out in soft/loose soil complete all as specified and directed.
M&L for returning, filling in excavated soil in trenches including spreading, levelling, watering and well ramming in layers n. exc. 25 cm thick complete all as specified and directed.
M&L for Removing of excavated soil to a distance n. exc. 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed.
M&L for laying local dry clean sand filling for cushioning in trenches around under ground cable complete all as specified and directed.
M&L for laying well burnt brick, old size in trenches, as protection of under ground cable complete all as specified and directed.
Supplying, laying in replacement , jointing and testing LT underground cable, heavy duty, 1100 Volts, PVC insulated and sheathed, armoured with multi-stranded aluminium conductor cable conforming to latest IS , laid in trenches/ducts or fixed to poles/walls or laid under roads/paths/drains/culverts duly protected in galvanised steel pipe of suitable sizes all bare conductor of cable duly insulated 1.1 KV grade heat shrinkable sleeve including cable gland and lugging etc at both ends, including disconnecting and taking out unserviceable damaged cable of any size complete all as specified and directed of following sizes. Make: Havells/Polycab/Grandlay. Note : Excavation, earth work, cable sand cushioning & cable protection shall be measured separately under relevant items of this schedule.
(a) 10 Sqmm 4 Core
(a) 10 Sqmm 2 Core
(b) 50 Sqmm 4 core
(c) 35 Sqmm 4 core
(d) 25 Sqmm 4 core
(e) 16 Sqmm 4 core
(f) 16 Sqmm 2 core
Supply & Laying in replacement GI tubing light grade in trenches/ fixed to poles/wall laid in trenches with mild steel clamps made out 50X6mm flat iron, bolts/nuts/washers, sealing at the ends with wooden / rubber bushes, MS clamps nuts and bolt shall be painted with two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer complete all as specified and directed of the following size :-
(a) 100mm bore
(b) 80mm bore
(c) 50mm bore
S&F factory fabricated bus bar chamber out door pedestal type made out of 2.0 mm thick CRCA sheet of size 750x500x400 mm duly painted with powder coating, simens grey/RAL fitted with four Nos aluminium bus bar of capacity 400 Amps duly mounted epoxy insulator , Cable connections of incoming and outgoing cables duly insulated PVC heat shrinkable sleeve 1.1 KV grade including one No MCCB, 200 Amps, 4 pole, 16 KA, with adjustable thermal setting Ics=100% Icu, including glands c/p lugs etc including 50x50x6mm angle iron frame 450mm height above ground level and 450mm below ground level, angle iron frame shall be embeded in PCC (1:2:4) type B 1 block of size 200x200x200mm complete all as specified and directed including taking out old unserviceable bus bar chamber.
S&F in replacement sheet metal enclosures 240 volt with suitable rated bus bar for double door 8 way IP-43 DB's mounting flush on wall/concealed and making good distubed surfaces incl taking out Unserviceable DB any capacity. complete all as specified and directed by Engr-in-charge.
All as per Item No 85.00 here in above but 6 way complete all as specified and directed.
S&F in replacement sheet metal enclosures for MCB DBs single pole and neutral 2 way complete all as specified and directed.
S&F in replacement TPN DB VTPN 4 way 415 Volts, 50 Hz indoor type double door Sheet metal enclosure IP-43 DB's flush mounted with 250 Amp Copper busbar for each phase with two neutral bar & two earthbar and cable ties for cable managenment including mounting arrangement for 04 pole MCCB as incomer including connection terminal strip complete pre wired with suitable size copper conductor. The DB's should hold type test certificate (CPRI) as per IEC 61439-3 complete all as specified and directed by Engr-in-charge incl taking out Unserviceable DBs, MCCB and MCBs of any capacity complete all as specified and directed. (MCB and MCCB shall be paid for separately)
S&F MCCB 63 Amps four pole 415 volts thermal magnetic trip release ICU=100% ICS having breaking capacity 16KA including connection terminal strip complete all as specified & directed
S&F MCB TPN 415 Volts 16 KA four pole 63m magnetic trip release and setting as incoming with fixing arrangement complete all as specified and directed.
S&F MCB SPN 240 Volt 10 KA 40 Amp 'B' series complete all as specified & directed.
S&F MCB SPN 240 Volt 10 KA 63 Amp 'B' series complete all as specified & directed.
S&F MCB single pole 240 Volt 10 KA 6 to 40 Amp 'B' series complete all as specified & directed.
S&F grouting with nut & bolts sheet metal box of size 60cmx90cmx25 cm fabricated made out of 2 mm thick MS sheet and suitable of angle iron and M S flat and provn of 6 mm thick bakelite sheet for fixing of main switches and DBs with double locking arrangement incl one coat of red oxide primer and two coats of synthetic enamel paint incl making good disturbed surfaces and taking down the unserviceable of wooden boxes all as specified and directed by Engineer-inp-Charge
S&F in replacement wall mounted tube light fitting 1x20/22 watts extruded aluminium polycarbonate covers PF 0.9 and above operating voltage 140V-270V colour temp 6500K & lumen input output 95 Lumen per watt and connected to ceiling rose with required length of two core flexible copper cable 23/0.0076 fixed on wall/roof complete all as specified and directed. Make: Philips cat part No TMC 501P1xT LED 22WP-3241(Tube Batten) and MAS LE$D 1200mm 18W-865-T-81 (Tube) / Wipro Cat part No WI0922208 (Tube Batten) LL13-181-65SE (Tube)/ Havells Cat Part No LUMILINEPLUSBS20WLED865SPCSS (Tube Batten)CRYSTAL1213T8DSTL20WLED865SGLASS(TUBE DOUBLE SIDE)
S&F in replacement LED down lighter recessed mounted 2x2 feet36W ultra modern designed LED luminaire which provide soft light and glair free symmetrical illumination suitable for grid ceiling and connected to ceiling rose with required length of two core flexible copper cable 23/0.0076 complete all as specified and directed. Make: Havells Cat Part no: ENDURASLIMPROPLUS2x2PLR28/36WLED 840MOD or equivelent make of PHILIPs/ CROMPTON
S&F in replacement LED light fitting 1x10 w bulk head fitting complete with accessories and including connecting up with twin core twisted flexible copper conductor cable of suitable size complete all as specified and directed. Make:WIPRO CAT PART NO-LW07-141-XXX-57XXor equivelent , HAVELLS/CROMPTON
S&F in replacement mirror light decorative compact luminarious with decorative ends caps 9/10 Watt LED with all accessories and including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed. . Make Havells Cat No Edgelite or equilent in Philips/Wipro
S&F in replacement LED light fitting decorative wall mounting SS brush finish fixture with frosted glass suitable for upto 1x40 watt mini glass lamp with and including one no 12 watt LED lamp. complete with accessories and including connecting up with twin core twisted flexible copper conductor cable of suitable size complete all as specified and directed. Make: Havells Cat Part NO LHFOAJE1TN1IO60 or equivelent of Bajaj/ Philips.
S & F lamp holder PVC/polycarbonate type with LED lamp 9/10 watt complete all as specified and directed.Make : Havells/HPL/Anchor high efficiency LED
Supply only inner copper tank of 20 gauge sheet rated pressure not less than 7kg/cum suitable for 25 ltrs capacity geysers complete all as specified and directed by Engineer-in-Charge. (Wt approx 3.75kg).
Supply only glass wool of same quantity and quality as for 25 ltrs cap geysers complete all as specified and directed by Engineer-in-Charge
M&L replacement of steel inner tank of minimum 20 gauge sheet rated pressure not less than 7 kg/con suitable for 25 ltrs capacity geysers (wt not less than 3.75 kg) as per sample.
M& L replacement of outer body MS Sheet not less than 20 gauge suitable for 25 ltr geyser painted with white synthetic enameled paints complete all as specified and as directed by Engineer-in-Charge..
Fixing only water storage heater capacity 25/50 ltrs of any make inclusive making all connection of electric and water in position and testing complete all as specified and as directed by Engineer-in-Charge (Geysers shall be issued under 'B')
Ansh Enterprises
M/S Garhwal Enterprises
M/s Ram Chander Gupta
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .