16 conditions · 4 needing a document upload
The tenderer must have minimum average annual contractual turnover of V/N or V which ever is less; where V= Advertised value of the tender in crores of Rupees N= Number of years prescribed for completion of work for which bids have been invited. The average annual contractual turnover shall be calculated as an average of "total contractual payments" in the previous three financial years, as per the audited balance sheet. However, in case balance sheet of the previous year is yet to be prepared/ audited, the audited balance sheet of the fourth previous year shall be considered for calculating average annual contractual turnover. The tenderers shall submit requisite information as per Annexure-VIB of IRGCC, along with copies of Audited Balance Sheets duly certified by the Chartered Accountant/ Certificate from Chartered Accountant duly supported by Audited Balance Sheet.
The tenderer should have valid electrical contractor's license for the required voltage level or above the required voltage level from any state / central government licensing board.
The contractor should submit valid electrical supervisory license issued by any state/central Government licensing board.
14 conditions · 3 needing a document upload
All the bidders / tenderers should ensure that they are GST compliant and their quoted tax structure / rates are as per GST law.
The tenderers are required to submit scanned copy of cancelled cheque and NEFT mandate form alongwith the offer.
The bidder should submit ESIC and EPFO registration certificate alongwith the offer.
The bidder should submit PAN/ADHAR alongwith the offer.
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
Tender Earnest money deposit: -All the tenderers / Contractors have to deposit full tender earnest money deposit as stipulated in the tender document through online modes only. Other option of deposition of EMD will not be accepted and will not be consider for tendering process.
Before submitting a tender, the tenderer will be deemed to have satisfied himself by actual inspection of the site and locality of the works, that all conditions liable to be encountered during the execution of the works are taken into account and that the rates he enters in the tender forms are adequate and all inclusive to accord with the provisions in Clause-37 of the Standard General Conditions of Contract for the completion of works to the entire satisfaction of the Engineer.
The balance sheet and all other financial documents attested/certified by the Charted Accountant (CA) to substantiate fulfilment of Financial Eligibility Criteria should be with UDIN, failing which the offer shall be considered as incomplete and will be summarily rejected without any further reference." (Ref: CE/Works/HJP letter no. ECR- HQ0ENGG(CONT)/0009/2025, dt- 18.11.2025)
The Railway reserves the right to verify all statements, information and documents submitted by the bidder in his tender offer, and the bidder shall, when so required by the Railway, make available all such information, evidence and documents as may be necessary for such verification. Any such verification or lack of such verification, by the railway shall not relieve the bidder of its obligations or liabilities hereunder nor will it affect any rights of the railway thereunder.
In case of any wrong information submitted by tenderer, the contract shall be terminated. Earnest Money Deposit (EMD), Performance Guarantee (PG) and Security Deposit (SD) of contract forfeited and agency banned for doing business on entire Indian Railway for 2 (Two) years.
If the e-tenderer/s deliberately give/s wrong information in his/their e-tender or creates/create circumstances for the acceptance of his/their e-tender, Railway reserves the right to reject such e-tender at any stage.
Railway reserves the right to either cancel the e-tender or reject any or all the e-tenders without assigning any reason thereof.
In addition to Indian Railway General Conditions of Contract 2022, as amended upto date, special conditions as per tender document shall also apply.
Tender related all document read be carefully and followed.
Provision of bi-directional line in diversion line/DDU by placing a X-over at EOC/DDU.
TRD-OT-16-Xover-EOC-26-27~ECR
TRD-OT-16-Xover-EOC-26-27
Open
Works - General
12 Months
Chandauli, Uttar Pradesh
₹0
₹3.1 L
22 Sept 2026
22 Sept 2026
1 Oct 2026
129 items across 1 schedule
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| — | — | — | 1,56,39,347.38 | ||
| — | 50.00 | — | — | ||
| Supply of OHE Structure Portal/Mast/TTC/Super Mast/AT Mast. As per RDSO no. ETI/OHE/13(4/84) or latest | — | — | — | 52,50,000 | |
| — | 50.00 | — | — | ||
| Erection of OHE Structure Portal/Mast/TTC/Super Mast/AT Mast. As per RDSO no. ETI/OHE/13(4/84) or latest | — | — | — | 1,70,000 | |
| — | 100.00 | — | — | ||
| Supply of Cantilever assembly complete with porcelain Insulators stay and bracket fitting assembly as per RDSODrg. no. ETI/OHE/G/02106 SH-1&3 or latest, spec.- TI/SPC/OHE/ 0070(4/07) or latest, drg- ETI/OHE/P/ 6030-1 , ETI/OHE/13(4/84) with slip A & C latest, RDSO specification No. TI/SPC/OHE/ INS/0070 [04/2007] and Drawing No. ETI/OHE/P/6030-1 Mod-C. | — | — | — | 20,66,667 | |
| — | 100.00 | — | — | ||
| Erection of Cantilever assembly complete with porcelain Insulators stay and bracket fitting assembly as per RDSODrg. no. ETI/OHE/G/02106 SH-1&3 or latest, spec.- TI/SPC/OHE/ 0070(4/07) or latest, drg- ETI/OHE/P/ 6030-1 , ETI/OHE/13(4/84) with slip A & C latest, RDSO specification No. TI/SPC/OHE/ INS/0070 [04/2007] and Drawing No. ETI/OHE/P/6030-1 Mod-C. | — | — | — | 69,511 | |
| — | 40.00 | — | — | ||
| Supply & Erection of Contact wire ending clamp. As per RDSO no.ETI/OHE/P/1120-2 or latest | — | — | — | 19,066.8 | |
| — | 40.00 | — | — | ||
| Supply & Erection of Catenary wire ending clamp. As per RDSO no. ETI/OHE/P/1120-2 or latest | — | — | — | 15,003.2 | |
| — | 140.00 | — | — | ||
| Supply of 5mm HD copper dropper wire. As per RDSO no. ETI/OHE/P/1193 or latest | — | — | — | 88,313.4 | |
| — | 140.00 | — | — | ||
| Erection of 5mm HD copper dropper wire. As per RDSO no. ETI/OHE/P/1193 or latest | — | — | — | 4,172 | |
| — | 500.00 | — | — | ||
| Supply & Erection of Contact wire dropper clip with U Pin. As per RDSO no. ETI/OHE/P/1180 or latest | — | — | — | 39,470 | |
| — | 500.00 | — | — | ||
| Supply & Erection of Catenary wire dropper clip with nut & bolts. As per RDSO no. ETI/OHE/P/11/92 or latest | — | — | — | 43,070 | |
| — | 600.00 | — | — | ||
| Foundation (PCC) (a) 1:3:6 ( 1 cement:3 sand:6 graded stone size 40 nominal size ) in which cement 220 Kg per M3 OPC 53 grade | — | — | — | 27,79,998 | |
| — | 60.00 | — | — | ||
| Foundation 1:2:4 ( 1 cement:2 sand:4 graded stone size 20 nominal size ) in which cement 320 Kg per M3 | — | — | — | 2,80,000.2 | |
| — | — | — | Above/ 156618.40 Below/P | ||
| Supply of Guy rod assembly complete suitable for Dwarf mast & ground anchor with all necessary attachment, fastenars & assembly RDSO no.ETI/OHE/G/01402 or latest | — | 40.00 | — | — | |
| — | 40.00 | — | — | ||
| Erection of Guy rod assembly complete suitable for Dwarf mast & ground anchor with all necessary attachment, fastenars & assembly RDSO no.ETI/OHE/G/01402 or latest | — | — | — | 7,871.2 | |
| — | 50.00 | — | — | ||
| Supply of MCC assembly complete. As per RDSO Drg no. ETI/OHE/P/3121or latest | — | — | — | 1,51,333.5 | |
| — | 50.00 | — | — | ||
| Erection of MCC assembly complete. As per RDSO Drg no. ETI/OHE/P/3121 or latest | — | — | — | 10,750 | |
| — | 4.00 | — | — | ||
| Supply & Erection of 25 kv single pole 1600 amp isolator including insulators with all fitting and accessories including & Erection of isolator as per Drg no. ETI/OHE/G/05513 sh-1 | — | — | — | 1,63,152.12 | |
| — | 4.00 | — | — | ||
| Supply of operating rod insulator | — | — | — | 12,201.28 | |
| — | 16.00 | — | — | ||
| Supply and Erection TI/SPC/OHE/INS/00700(04/07) or latest | — | — | — | 70,168.8 | |
| — | — | — | RDSO | ||
| — | — | — | Spec. | ||
| — | 8.00 | — | — | ||
| Supply of section insulator complete with core insulator. As per RDSO no. ETI/OHE/27(8/84) or latest | — | — | — | 3,00,169.6 | |
| — | 8.00 | — | — | ||
| Erection of section insulator complete with core insulator. As per RDSO no. ETI/OHE/27(8/84) or latest | — | — | — | 20,214 | |
| — | 10.00 | — | — | ||
| Supply & Erection of single Termination (Single celvis, distant rod, Turn Buckle, double strap, Catenary ending ) assly. As per RDSO no. ETI/OHE/G/03120 or latest | — | — | — | 27,824.9 | |
| — | 10.00 | — | — | ||
| Supply & Erection of double Termination assembly (Single celvis, distant rod, Turn Buckle, Equilizig plate, double strap, Catenary & Contact ending). As per RDSO no. ETI/OHE/G/03120 or latest | — | — | — | 37,494.6 | |
| — | 50.00 | — | — | ||
| Supply & Erection of 40x6 MS flat structure bonds 4.75 m imp as per RDSO Spec. ETI/OHE/P/7000 or latest6 | — | — | — | 30,932.5 | |
| — | 100.00 | — | — | ||
| Supply & Erection of 40x6 MS flat structure bonds 3 m as per RDSO Spec. ETI/OHE/P/7000 or latest6 | — | — | — | 53,924 | |
| — | 20.00 | — | — | ||
| Supply & Erection of 40x6 MS flat Z bonds 4m | — | — | — | 9,186.6 | |
| — | 20.00 | — | — | ||
| Supply & Erection of 40x6 MS flat intertrack bonds 5m | — | — | — | 8,933.8 | |
| — | 20.00 | — | — | ||
| Supply & Erection of 40x6 MS flat Longitudinal bonds 1.7M | — | — | — | 5,591.8 | |
| — | 1500.00 | — | — | ||
| Erection of copper catenary wire 65 sq mm. As per RDSO no. TI/SPC/OHE/CAT CU-CD 0971 and STR No TI/STR/020 Rev 01 or latest | — | — | — | 25,695 | |
| — | 1500.00 | — | — | ||
| Erection of HD groved copper Contact wire 107 sq mm. As per RDSO no. TI/SPC/OHE/CW/0971 or latest | — | — | — | 23,070 | |
| — | 11.00 | — | — | ||
| Supply & Erection of small part of steel. As per RDSO no. ETI/OHE/13(4/84) & 49(9/95)or latest | — | — | — | 11,73,333.37 | |
| — | 200.00 | — | — | ||
| Supply & Erection of Copper Jumper 160 sq mm. As per RDSO Spec. no. ETI/OHE/3(2/94) Rev -1 or latest | — | — | — | 3,06,328 | |
| — | 6.00 | — | — | ||
| Supply of ATD(3 Pulley type) 3:1 complete with SS wire rope & counter weight assembly. | — | — | — | 2,83,073.34 | |
| — | 6.00 | — | — | ||
| Erection of ATD (3 Pulley type) 3:1 complete with SS wire rope & counter weight assembly. | — | — | — | 15,866.1 | |
| — | 40.00 | — | — | ||
| Supply of 9 Ton insulator. As per RDSO no. TI/SPC/OHE/0070(4/07) or latest | — | — | — | 3,23,859.2 | |
| — | 40.00 | — | — | ||
| Erection of 9 Ton insulator. As per RDSO no. TI/SPC/OHE/0070(4/07) or latest | — | — | — | 8,933.2 | |
| — | 200.00 | — | — | ||
| Supply & Erection of PG clamp (1030/1040). As per RDSO no. ETI/OHE/G/SK/231 or latest | — | — | — | 61,334 | |
| — | 100.00 | — | — | ||
| Supply & Erection of Retro Refelctive type OHE structure NUMBER Plate including all fixing accessories. | — | — | — | 67,500 | |
| — | 100.00 | — | — | ||
| OHE foundation broken | — | — | — | 1,62,643 | |
| — | 15.00 | — | — | ||
| Dismantling/cutting of portal structures complete including boom and associated small parts steel work complete | — | — | — | 2,70,155.85 | |
| — | 30.00 | — | — | ||
| Transportaion of Realease material to central depot including loading and unloading | — | — | — | 1,55,721.3 | |
| — | 20.00 | — | — | ||
| Febrication, supply & erection of SWR/Sectioning diagram board on suitable acrylic/FRP sheets framed in wood/metal frame as per approved diagram with coloring as per code of section. | — | — | — | 12,107.2 | |
| — | 1.00 | — | — | ||
| Preperation and designing of Traction station working rule/ Sectioning diagram through Autocad software for DDU-MPO section and ARA-SSM section, SEB-GHD section and supply final drawing on good quality tracing paper with approval concerned divisional officers and also provide soft copy on pdf and AUTOCAD | — | — | — | 5,403.01 | |
| — | 1.00 | — | — | ||
| Preparation of bi-lingual (Hindi & English) Traction Station working rule and printing of booklet (Scroll binding) of SWR consisting of literature and Appendix- G with aprroval of concerned divisional officers of DDU division. (colour) | — | — | — | 4,291 | |
| — | 250.00 | — | — | ||
| Xerox copy of SWR consisting of literature and Appendix-'G' | — | — | — | 370 | |
| — | 5.00 | — | — | ||
| Booklet (Spiral binding ) of SWR consisting of literature and Appendix-'G' | — | — | — | 370.9 | |
| — | 5.00 | — | — | ||
| Preparation all drawing and design for overhead equipment including preparation of pre pegging, pegging and OHE layout plan with submission of 3 copy colour drawning including as erected SED. | — | — | — | 84,126.3 | |
| — | 1.00 | — | — | ||
| Supply of all aluminum 'SPIDER' conductor of size 234 sq mm | — | — | — | 1,70,927.4 | |
| — | 1.00 | — | — | ||
| Erection of all aluminum 'SPIDER' conductor of size 234 sq mm | — | — | — | 17,092.4 | |
| — | 1.00 | — | — | ||
| Supply of 12.24 mm dia ACSR Raccoon (AEC) with mast fitting as per RDSO drg | — | — | — | 58,276.03 | |
| — | 1.00 | — | — | ||
| Erection of 12.24 mm dia ACSR Raccoon (AEC) with mast fitting as per RDSO drg | — | — | — | 2,913.63 | |
| — | 1.10 | — | — | ||
| Supply of 20 mm dia galvanized steel conductor (BEC) as per RDSO drg. | — | — | — | 33,387.23 | |
| — | 1.10 | — | — | ||
| Erection of 20 mm dia galvanized steel conductor (BEC) as per RDSO drg. | — | — | — | 1,668.48 | |
| — | 22.00 | — | — | ||
| Supply & Erection of Tee connector for BEC end and lug for connection | — | — | — | 33,892.76 | |
| — | 40.00 | — | — | ||
| Removal of cantilever Assembly | — | — | — | 21,466.8 | |
| — | 10.00 | — | — | ||
| Charges for road crane work under power block for special type heavy portal erection and dismantling | — | — | — | 2,88,553.1 | |
| — | 2.00 | — | — | ||
| Erection of 25 KV/240V 1- phase 25 KVA capacity Aux. transformer as per RDSO Spec. with first filling of oil & provided all stander fitting with all testing. | — | — | — | 13,030.42 | |
| — | 2.00 | — | — | ||
| Supply & Erection of 25KV D.O.fuse assly complete with barrel fuse RDSO Drg no.ETI/PSI/032 or Latest | — | — | — | 27,400 | |
| — | 4.00 | — | — | ||
| Supply & Erection of 25KV caution, board as per RDSO DRG.no. ETI/OHE/P/7531 or latest | — | — | — | 2,560 | |
| — | 2.00 | — | — | ||
| Supply & Erection of Cat. Sus. Clamp. As per RDSO no.RE/33/P/1160 or latest | — | — | — | 1,426.66 | |
| — | 4.00 | — | — | ||
| Supply & Erection of anticlimbing device. As per RDSO no. ETI/OHE/P/106 or latest | — | — | — | 7,120 | |
| — | 2.00 | — | — | ||
| Supply & Erection of Catenary copper jumper or latest | — | — | — | 6,413 | |
| — | 60.00 | — | — | ||
| Dismantling/cutting of released OHE/AT mast/Portal(per leg) /TTC & transporting of released mast from site to nearest depot including loading & unloading. | — | — | — | 77,400 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
AnnexureVVA.pdf
ATTACHMENT
formatofe-BG.pdf
ATTACHMENT
GCC-2022.pdf
ATTACHMENT
ACS11GCCWorks.pdf
ATTACHMENT
ACS12GCCWorks.pdf
ATTACHMENT
GCCamendwithCslip.pdf
ATTACHMENT
TenderDoc1.pdf
ATTACHMENT
TenderDoc2.pdf
ATTACHMENT
TenderDoc3.pdf
ATTACHMENT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .