Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹15.9 CrAccepted-AOC | ₹15.9 Cr | L-1 | Accepted-AOC AOC amount (after deduction of Sch of credit 612474.00) 159135380.92 |
| 2 | L-2₹16.6 CrRejected-Finance | ₹16.6 Cr | L-2 | Rejected-Finance Other than lowest quoted bidder |
| 3 | L-3₹16.9 CrRejected-Finance | ₹16.9 Cr | L-3 | Rejected-Finance Other than lowest quoted bidder |
| 4 | L-4₹17.7 CrRejected-Finance | ₹17.7 Cr | L-4 | Rejected-Finance Other than lowest quoted bidder |
| 5 | L-5₹18.1 CrRejected-Finance NOT SPECIFIED | ₹18.1 Cr | L-5 | Rejected-Finance Other than lowest quoted bidder |
Tender Value
Refer Docs
EMD Value
₹10.4 L
Closing Date
4 Jan 2021, 6:00 pmClosed
CE Navy Visakhapatnam
CE Navy Visakhapatnam Station Road Visakhapatnam-530 004
DEMOLITION_RECONSTRUCTION OF SAILORS MARRIED ACCN AT SVN COLONY VISAKHAPATNAM
2020_MES_371234_2
CE(NAVY)/VIZ/TOKEN/ 26 OF 2019-2020
Open Tender
Civil Works
660 days
Visakhapatnam
Please refer Tender documents.
9 documents required · 9 mandatory
₹3,000
Yes
GE (P) (N) Visakhapatnam
₹10.4 L
Yes
1 Feb 2021
14 Dec 2020
5 Jan 2021
14 Dec 2020
4 Jan 2021
23 Dec 2020
Amount
Schedule 'A' Part-I to Schedule 'A' Part-XIX: Note: Schedule 'A' Part-I to Part-XIV are prepriced by MES. Bidders shall insert their lump sum amount in green coloured field under Column 6 only.
Lumpsum price worked out by the contractor for 'Buildings & Structures', as listed in Schedule 'A' Part-I on Serial Page No.31[R]
Lumpsum price worked out by the contractor for 'Site Clearance,Earthwork and Excavation', as listed in Schedule 'A' Part-II on Serial Page No. 34.
Lumpsum price worked out by the contractor for 'Pile Foundation', as listed in Schedule 'A' Part-III on Serial Page No. 36
Lumpsum price worked out by the contractor for 'Internal Water Supply', as listed in Schedule 'A' Part-IV on Serial Page No. 39.
Lumpsum price worked out by the contractor for 'Internal Electric supply', as listed in Schedule 'A' Part-V on Serial Page No. 44[R].
Lumpsum price worked out by the contractor for 'External Water Supply, as listed in Schedule 'A' Part-VI on Serial Page No. 45[R]
Lumpsum price worked out by the contractor for 'External Electric supply', as listed in Schedule 'A' Part-VII on Serial Page No. 48[R].
Lumpsum price worked out by the contractor for 'Road,Path,Hard Standing and Culvert', as listed in Schedule 'A' Part-VIII on Serial Page No. 51[R]
Lumpsum price worked out by the contractor for 'Sewage Disposal', as listed in Schedule 'A' Part-IX on Serial Page No. 54[R]
Lumpsum price worked out by the contractor for 'Area Drainage', as listed in Schedule 'A' Part-X on Serial Page No. 56[R]
Lumpsum price worked out by the contractor for 'Solar Water Heater', as listed in Schedule 'A' Part-XI on Serial Page No. 57.
Lumpsum price worked out by the contractor for 'Internal Fire Fighting & Fire Alarm System', as listed in Schedule 'A' Part-XII on Serial Page No. 58.
Lumpsum price worked out by the contractor for 'External Fire Fighting ', as listed in Schedule 'A' Part-XIII on Serial Page No. 59.
umpsum price worked out by the contractor for 'Demolition', as listed in Schedule 'A' Part-XIV on Serial Page No. 61[R].
Schedule 'A' Part - XV: [Miscellaneous Items] [Pile foundation , Internal Water Supply, External Water Supply, Internal Electric Supply, External Electric Supply,Road/Path/Hard Standing and Culvert, Lightning Protection, Internal Fire Fighting and Fire Alaram System, External Fire Fighting, , Solar Water Heater,DG Set,Lifts, Arboriculture,Demolition and Aviation lights]:
Boring for bored cast-in-situ piles 600mm dia. in any strata except SDR/hard rock and getting out and disposal of spoil out side MD land using Hydraulic system of boring method, complete all as specified and directed.
Chipping out pile up to cut off level & disposal outside MD land all as specified and directed.
Boring for bored cast-in-situ piles 600mm dia. in hard rock and getting out and disposal of spoil out side MD land using hydraulic system of boaring method complete all as specified and directed.
Carrying out initial load test on 600mm dia. pile as per IS 2911 Part IV, complete all as specified and directed.
Carrying out routine load test on 600mm dia. pile as per IS 2911 Part IV, complete all as specified and directed.
Carrying out lateral load test on cast in situ piles 600mm dia. piles as specified in IS and directed by Engr-in-Charge.
Carrying out pull out test on cast on situ piles 600mm dia. pile as per specified in IS ,complete all as specified and directed by Engr - in- charge.
Carrying out low strain integrity test on bored cast in situ piles including analysing the result as per ASTM D 5882 and as directed by Engr - in- Charge.
S&F bib taps of size 15mm, long body cast copper alloy chromium plated fancy type, screwed down for pipes all as directed.
S&F PVC Hot water pipe duly insulated with glass wool and aluminium cladding 20 mm bore fixed on wall, with and inclussive of necessary fixing material complete all as specified and as directed.
S&F PVC Hot water pipe duly insulated with glass wool and aluminium cladding 25 mm bore fixed on wall, with and inclussive of necessary fixing material complete all as specified and as directed.
S&F angular cock of size 15mm, fancy type cast copper alloy, with capstan heads, chromimum plated, screwed down high pressure pipes all as directed.
S&F Health faucet, ABS rubbit cleaning system, with 1.25 m long PVC flexible tube and ABS wall hook 15 mm complete all as specefied and directed.
Supply and fix Telephone socket with shutter glossy white with terminal box and fixing plate complete all as specefied and directed.
Point wiring with 1.5 Sq mm FRLS PVC insulated and unsheathed multi stranded copper conductor, 1100 volt grade,ISI marking drawn thorugh and including non metallic rigid PVC concealed conduit and conduit accessories, medium grade, ISI marked, concaled including provn of pressed steel terminal box of suitable size fabricated out of 2 mm thick MS sheet and 3 mm thick lamianted hylam sheet top cover for fixing switches, sockets, as requied at site including one run of 1.5 sqmm PVC insulated unsheathed copper cable for earth continuity connected to earth dolly complete as directed and specified for the following :-
(a) One light point controlled by one switch
(b) One bell point controlled by one bell push
(c) One fan (ceiling/Wall/Ex fan) point controlled by one switch
(d) One 3 Pin socket outlet 5 amps socket on independent board
(e) One 3 pin socket outlet 15 amps socket on independent board with 2.5 sqmm FRLS PVC wire and one run of 2.5 sqmm copper cable for earth continuty.
All as per item No. 33 here-in-before but controlled by two Nos two way switches complete all as specefied and directed.
S&F Switch Socket combination 2 in 1, flush type 3 pin 5 amps and 15 amps
S&F switch piano ,flush type two way 5 amps
Supply and fix TV socket glossy white with terminal box and fixing plate complete all as specefied and directed.
S & F Energy efficient 4 ft LED light fitting with tube 20 watt ,240V surface mounted LED batten type with extruded aluminium/CRCA housing and robust constrution with necessary acrylic cover as diffuser complete with mounting bracket etc including connecting up with 1.0 sq mm 3 core copper conductor cable with suitable size.
S & F 2 ft Energy efficient LED light fitting with tube 09 watt ,240V surface mounted LED batten type with extruded aluminium/CRCA housing and robust constrution with necessary acrylic cover as diffuser complete with mounting bracket etc including connecting up with 1.0 sq mm 3 core copper conductor cable with suitable size.
S & F Energy efficient LED light fitting with tube 05 watt ,240V surface/wall mounted LED batten type with extruded aluminium/CRCA housing and robust constrution with necessary acrylic cover as diffuser complete with mounting bracket etc including connecting up with 1.0 sq mm 3 core copper conductor cable with suitable size.(for mirror light)
Supply and fixing LED bulb 15 watts, 240 volt, B22 base type,pin type siutable for angle holder.
S/F LED Security light fitting of AC 240 Volts, LED bulb of 30W New generation Energy saving & environmental frindly long life versatile pressure die cast aluminium housing with high power LED as lighting source and PC cover having TOP opening seperate driver compartment with IP66 protection pre wired with 1.0 Sq mm copper conductor cable upto connector including 2 Mtr long GI Tubing Med grade suitable dia bend to shape fixing on wall with suitable MS brackets compelte all as specified and as directed.
Supply and fixing ceiling fans AC single phase 230 V of size 1200 mm sweep with complete set with fixtures, 5 Star rating, metallic body complete all as specefied and directed.
S&F Exhaust fan 250 mm sweep plastic body(Heavy duty), complete with louvers suitable for operation on 230 V AC, 50 Hz AC supply fixed on wall making opening, fixing, making electrical connetion from ceiling rose to fan through suitable copper flexible wire and making good the disturbed surfaces etc complete all as spcified and as directed.
S&F Exhaust fan 300 mm sweep metallic body(Heavy duty), complete with louvers suitable for operation on 230 V AC, 50 Hz AC supply fixed on wall making opening, fixing, making electrical connetion from ceiling rose to fan through suitable copper flexible wire and making good the disturbed surfaces etc complete all as spcified and as directed.(for Kitchen)
S&F Exhaust fan 380 mm sweep metallic body(Heavy duty), complete with louvers suitable for operation on 230 V AC, 50 Hz AC supply fixed on wall making opening, fixing, making electrical connetion from ceiling rose to fan through suitable copper flexible wire and making good the disturbed surfaces etc complete all as spcified and as directed.(lfor lift machine room)
S&F concealed in wall Vertical DB double door TPN 4 way 415V, 50Hz double door, IP 43 protection with 200A rated bus bar , including provision for MCCB TP 63 amp as incommer and outgoing circuits MCB SP/TP complete, fill empty with blanks complete all as specefied and directed. Note: MCBs and MCCB shall be measured and paid seperately ( for each floor)
S&F MCB SP 6 to 32 Amps 240 Volts
S&F MCB SPN 6 to 32 Amps 240 Volts , 10KA complete all as specified and directed.
Supply and fixing single phase electronic energy meter tamper proof, AC, 240 Volts 50 Hz of currrent rating 5 to 30 amps with LED display as per IS 13779 complete all as specified and as directed
Supply and fixing energy meter box of FRP material to accommodate six energy meter fixed on wall with provision for small opening to each meter covered with glass for taking meter reading without opening the box complete all as specified and as directed.
M&L for earthing complete with copper plate electrode 600X600X3mm thick, burried directly in ground (earth pit not less than 2.25 metres deep below ground level)with top edge of the plate not less than 1.5 metres below normal groundlevel, connected to copper strip of 20x3mm by means of bolts, nuts, check nuts and washers of copper all as shown in electrical plate No-5 of SSR Part-I connected to earthing test point all as specified or indicated including excavation and connected earth work in hard/dense soil, PCC M-10 type C-1 as in pit, 20mm dia GI pipe medium grade for watering pipe, 25 mm bore GI light grade earth lead protection pipe connected upto LT pannel, and suitable C.I top cover with handle, funnel, strainer,charcoal and testing on completion all as specified and directed. Note: Rate quoted deemed to be include GI protection pipe, funnel, excavation and earth work, in any type of soil with PCC type B2 in pad and pit complete all as specefied and directed.
M&L for laying of Ductile Iron pipe with spigot and socket end centrifugally cast(spun) class K-9 of 100mm dia pipe conforming to IS-8329 including provision of fittings, such as tees, elbows,bends reducers, taper pieces, including testing and commissioning all as specified and directed.
Masonry valve chamber of internal 750 x 750 x 750 mm comprising of 50mm thick PCC M-5 type E2 foundation, 200mm thick brick wall in CM (1:6) ,15 mm thick plastering in CM (1:4) internal and externally up to 50mm below GL, 100mm thick PCC M-10 type B1 as in coping . 3 mm thick MS sheet cover with suitable hinges and locking arrangement, painting steel surface with two coat of synthetic enamel paint over a coat of primer including necessary earth work and excavation in any type of soil complete all as specified and as directed.
Cutting existing DI pipe line for altrations or additions necessarily done in position without taking down and inserting 'Tee of 150x150x100 mm' and Tee for tapping all as specified and directed.
Supply and installation of electric driven centrifugal pump set of head 50 Mtr, 1950 LPM suitable for 415V, 3 phase for 440 V, confirming to IS 12469:1988 with CI casing bronze impeller and stainless steel shaft mounted on heavy duty bearings of suitable capacity not less than 10 HP including starter panel all as specified and as directed.
Supply and fix flanged end lift type Foot Valve 100 mm dia with brass strainer, suitable flanges, nuts, bolts, gaskets complete all as specified and as directed.
Supply and fix aviation obstruction light LED type filament-less bulb with 10 Watt bulb complete including standard fixing arrangements all as specified and as directed
Supply and fix cable PVC insulated PVC sheathed LT 1100 V grade with copper conductor of size 3 core 2.5 sqmm multi stranded conductor laid in ground fixed to wall roof etc with suitable calmps spacers bolts nuts etc. all as specified and as directed
Supply and fix time switches 250 V single Phase of 20 Amp rating with contactor Fitted inside steel enclosure all as specified and as directed
Silent engine generating set with accoustic enclosure as per CPCB norms 415 volts 100 kVA 3 phase 0.8 power factor 50 Hz, 1500 RPM self excited self regulated brushless AC generator including accoustic enclosure suitable for ambient condition and conforming to condition under IS 4722, BS 5514/ 2613 /5000 with and including the following:-
(i) The capacity of Generator set shall be net after all due de-rating factors as per relevant ISI design
(ii) Rate quoted shall be deemed to be inclusive of cable and terminations form Generator to the AMF Panel, with necessary holes to wall including making good to disturbed surfaces so as to match with the existing finishes all as specified and directed.
(A) Alternator :- Standard design alternator rated at 100 kVA net output at site after considering de-rating as per site conditions at 0.8 (lag) power factor AC, 3 - phase 4 - wire 415 volts 50 Hz, 1500 RPM, self excited self regulated screen protected drip proof IP 23 enclosure brushless design with winding in pole faces, insulating class 'H' and voltage regulation of +/- 1% at rated voltage from no load to full load. The alternator shall be conforming to BS 2613/5000 and shall be imposition to generate supply with frequency regulation with in +/- 1% tolerance. The alternator will be suitable for tropical climate and shall generally conform to BS - 2613/5000/ IS – 4722
i) Insualation class - 'H‘
ii) Temparature rise Class - 'H‘ iii) Excitation : Self Excited iv) Regulation performance: The voltage is kept constant with +/- 1%, manual voltage adjustment within +/- 5% v) Frequency regulation +/- 1%
(B) Diesel Engine: - Adequate capacity of Diesel engine as accosted by the accepting officer basing on manufacturers technical details water cooled to drive independently above alternator and after considering de-rating as per site conditions after generating and reducing power consumed by accessories directly coupled through flexible coupling multi cylinder multi stroke direct injection, cold starting 1500 RPM, as per relevant ISI/BS - 5514 with an overload capacity of 10% for half an hour in 12 hours continuous running complete with standard accessories all as specified and required for safe handling and operation salient features of accessories shall be as under
i)Fly wheel with housing
ii) Cooling system :- Moulded radiator with fan & belts iii) Cooling Water pump : - Centrifugal type belt driven iv) Exhaust System :- Exhaust System complete with exhaust piping of 150mm dia with MS pipe light grade upto & outside and 1meter away from the enclosure, covered with asbestos rope and aluminium foil of 28 SWG complete with in the enclosure for safe exhaust without transforming vibration to the wall of the enclosure. Exhaust gas turbo charger type. Exhaust manifold Silencer : Residual type Bellows
iv) Fuel System :- Fuel injection system with fuel injectors, fuel injection solenoid switch controlled by electronic governor for 1% speed /frequency regulation, Fuel filters, Fuel hoses. v) Lub oil System : Lubricating oil filter Lubricating oil pump
vi) Air Intake System : Air intake Manifold Air cleaner dry type vii) Governor :- Electronic Governor viii) Starting System :- Electric Self starter with maintenance free battery including battery charging alternator
ix) Batteries :- Batteries of maintenance free of capacity as recommended by the manufacturer complete with copper conductor multi stranded leads of suitable length from self starter to the battery terminals complete with initial charge and initial fill of electrolyte all as specified and Starter gear ring Start and stop push button, Ignition key / Switch Handling and operation : Salient features of accessories shall be as under: Radiator with blower fan
Corrosion inhibitor coolant Paper element filters for fuel, lub oil and by pass Electronic governor controlled direct fuel injection system Fly wheel housing and fly wheel
x) Generator Monitoring Panel : - Comprising of all standard items as mentioned under this schedule or asper standard practice iginiton key switch and start / stop arrangement, indications for Engine parametes, hour run meter, RPM meter, Engine oil pressure indicator, water/coolent temparature indicator, Battary volt display.
xi) Safety Controls : - Engine low lube oil pressure high water temparature and over speeding of engine
xii) Coupling arrangement : - Flexible coupling, fly wheel to suit flexible coupling
xiii) Accessories :- AVM Pads built in enclosure and for entire unit on platform. xiv) Base Frame : - Shall be provided as per OEM norms
C) AMF Panel :- Factory made Double door outdoor AMF Panel control cubical made out of 2mm thick CRCA sheet dust and vermin proof totally enclosed with front opening of 415 volts 3 -phase 4 - wire AC 50 Hz, including powder coated, copper bus bar of one and half times the rated load of 100 KVA alternator complete with internal wiring with PVC insulated single core copper conductor multi stranded wire of 1100 volts grade of suitable capacity, fuses, name plates consisting of 4 pole MCCBs and Contactors of capacity as recommended by the manufacturer. Detachable cable gland plates, all controls, indicators and standardstandard microprocessor based LED/LCD display for indicating voltage, current, frequency, speed, kW, kWH, pf, temperature, Battery voltage, etc
g) Annuciation with indication lamps for : (i) Low lub oil pressure.
(ii) High Water Temparature. (iii) Engine over speed. (iv) Battery low voltage
Controls :- a) Load on Indication b) Load off indication c) Engine start push button d) Engine stop push button e) Fault accept / reset push button
f) Battary Charger : (i) Transformer (ii) Rectifier
D) Accoustic Enclosure:- Manufactured by OEM suitable for 100 KVA DG Set (i) NAL approved as per CPCB (ii) It Should be as per latest rules and regulations of Ministry of Environment and Forest and Pollution control board
(iii) The generating set battaries and control panel shall be inside the enclosure. (iv) Blank (v) Construction Details/specification are as follows: a) Outer body :- CRCA Sheet of 1.6mm thick b) Doors :- CRCA sheet of 1.6 mm thick
c) Sound Insulation :- As per OEM Norms vi) The accoustic shall be composite in construction and fully assembled integral unit
vii) The batteries shall be placed inside the enclosure beside the DG Set on a suitable insulated plat form viii) The fuel tank is to be located in Sub Station Building and cost of the fuel lines is deemed to be included in the offer.
ix) The DG Set shall be provided with external Emergency stop push button x) The enclosure shall be suitably illuminated by LED Lamp fittings. xi) The noise level shall be 75 dba at 1m under free field conditions.
xii) The acoustic enclosure parts shall be of powder coated after pre treatment process. The powder coating shade should be Gen set Green. The base frame should be painted with epoxy based black shade
E) The coated rate include excavation, removing of soft soil and PCC, Cement Concrete foundation, filling and mass concrete type B2 M 15 using 40 mm graded aggregate of size as per OEM but not less than 4.6 x 2. 4 x 0.8 m for placing of DG Set complete all as specified and directed.
Material and Labour for earthing complete with galvanised steel earth plate electrode 600×600×6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below normal ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected to galvanised earth lead strip of 32 X 6 mm by means of bolts, nuts, check nuts and washers of galvanised iron or steel and 50 mm dia light grade GI pipe upto test point or 7.5 mtr for protection of earth electrode and GI pipe 20 mm medium grade for watering pipe with watering funnel all as specifird and shown in electrical plate No. 3 of SSR part-I including charcoal and rock salt with necessary excavation and earth work in any type of soil PCC M-10 type C1 chamber with CI cover of 10 mm thick with MS rod 6 mm dia 150mm long reinforcement all as specified and as directed on completion.
Earthing complete with galvanised steel earth plate electrode 600×600× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below normal ground level) with top edge of the plate not less'than 1.5 metres below normal ground level connected to galvanised earth lead strip of 25x4 mm by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as specified and shown in electrical plate no 3 of SSR part-I including charcoal and rock salt with necessary excavation and earth work in any type of soil PCC M-10 type C1 chamber with C1 cover of 10 mm thick with MS rod 6 mm dia 150mm long reinforment ,watering funnel with 15 mm dia light grade for watering and for protection of earth electrode 32 mm dia GI pipe all as specified and as directed and tested on completion.
Supply, Installation, testing and commissioning of following capacity Solar Water Heating system at 60 degree centigrate with solar flat plat collectors complete with 304 grade stainless steel storage tank, insulated with 75mm thick poly urethane foam(PUF) and supporting frames for solar panels with MS angle iron of size 40mm X 40mm X 4mm (normal size) and for storage tank with 50mm X 50mm X 5mm thick angle iron and 50mm X 6mm thick flat iron,painting the metal parts with one coat of metal primer and two coats of synthetic enamel paint of approved brand and shade, required control valves like NRV, strainer and gate valves for storage tank, temprature gauge, including providing suitable cement concrete foundation for supporting stands of Solar panels and storage tank, interconecting the individual system as per specifications and conditions attached.
a) SWH system of 2 X 300 LPD capacity with suitable solar flat plate collectors and storage tank of 300 Liters capacity.
b) Necessary MS angle structure and PCC work shall included in the unit rate.
Supply ,fixing and testing PVC insulated, PVC sheathed cable galvanized steel strip or wire armoured, electric control cables with stranded copper conductor of size 1.5 sq mm ,2 core, 1100 Volts grade all as specified and as directed.
Supply and fix addressable single action manual call station having an integrally mounted addressable module that monitors and reports contact status all as specified and as directed.
Supply, install and commissioning analogue addressable type Fire alarm control panel along with network interface card and with Lead acid battery back up for 08 hours normal operation and 15 minutes alarm operation. (The control panel, battery charger, etc shall be UL listed) Complying with BS EN 54 double loop panel with 99 detectors & 99 modules & upto 200 detectors and modules (per each loop) complete all as specified.
Material and Laboure for laying of Ductile pipe with double flanged centrifugally cast(spun) class K-9 of 150mm dia pipe conforming to IS-8329 including provision of specials, such as tees, elbows,bends reducers, taper pieces, including testing and commissioning (For external Ring main and upto Bldg) all as specified and as directed.
Supply and fix MS flanged pipe 150mm NB heavy duty duly painted with 2 coats of synthetic enamel paint over coat of zinc chromate primer all as specified and as directed.
Supply and fix MS ERW pipes, "Heavy Class", complete including fittings 100mm all as specified and as directed.
Supply and fix MS ERW pipes, "Heavy Class", complete including fittings 80mm all as specified and as directed.
Supply & fix fire hydrant landing valve type A (single head outlet) of 63 mm dia conforming to IS 5290 including PVC blank cap and GI chain,CI hand wheel complete all as specified and directed.
Supply and fix MS cabinet (approx 800mm x 600mm x 250mm) fabricated from 16 gauge sheet with full front glass door and locking arrangement painted and mounted on masonry platform complete all as specified and as directed.
Supply and fix 63 mm dia 15 meter long hose conforming to IS 636 complete with male and female coupling conforming to IS 903 including all jointing materials complete all as specified and as directed.
Supply and fix Yard hydrant Post / Stand Post 80/100 mm Dia GI / MS both flanged type 1.5m Height with provn of single outlet conforming to IS 908 all as specified and directed.
Supply and fix Butterfly valve of 80 mm dia, double flanged conforming to IS 14846 PN 1.6 complete all as specified and as directed.
Supply and fix first aid hose reel drum of swing type with hose reel of size not less than 20 mm dia rubber braided hose confirming to IS 884 of 30 mtr length including nozzle complete all as specified and directed.
Supply and fix of Fire pump diesel engine driven horizontal end suction, centrifugal type confirming to IS- 12469 1988 with CI casing , bronze impeller and stainless steel shaft mounted on heavy duty bearings suitable for continuous operation with 'range of operation' 0 % to 150 % of rated capacity for 440 V , 3 phase, 50 Hz, 70 m Head. 2280 LPM discharge at 3.5 kg/sqcm along with 180 AH batteries ( 02 Nos of 12 Volts 180 AH Batteries) all as specified.
Supply and fix Fire pump electrically driven horizontal end Suction, centrifugal type confirming to IS- 12469 :1988 with CI Casing , bronze impeller and Stainless steel shaft mounted on heavy duty bearings Suitable for continuous operation with 'range of operation' 0 % to 150 % of rated capacity for 440 V , 3 Phase. 50 Hz AC supply 70m Head, 2280 LPM discharge at 3.5 kg/sqcm.
Supply and fix Jockey pump vertical end suction centrifugal type Confirming to IS- 12469: 1988 with CI casing , bronze impeller and stainless steel shaft mounted on heavy duty bearings suitable for automatic operation with nonover loading power characteristics for frequent start / stop operations for 440 V , 3 phase, 50 Hz 70 head 180 LPM discharge at 7.0 kg/sqcm. all as specified and as directed.
Supply and fixing PLC controlled LT Panel board made out of CRCA sheet 2.0 mm thick indoor Pedestal type totally enclosed with front and rear opening, hinged doors with projected an raised platform of suitable size weather and water proof with necessary locking arrangements along with lugs, cable glands of various sizes for cables, danger notice plate, strickering of Switcher gear about termination of switch gear, and the nuts/ bolts etc used are to be made of rust proof material including as per IS: 8623 Aluminium bus bar with heat proof colour code, insulators suitable for three phase and four wire LT AC, 50 Hz 415 V , 300 A capacity complete with powder coating, necessary internal electric connection as required and as specified and directed. The Bus Bar rating shall be 300 Amp along with all accessories as specified hereunder:
Incoming: [a] LT 440 volts 3 phase, 4 wire 50 cycles, 25kA, Adjustable type MCCB of 160 Amp rated complete with overload protection, no-volt thermal based release. Outgoing: [a] LT 440 volts 3 phase, 4 wire 50 cycles, 25kA, Adjustable type MCCB of 125 Amp rated complete with overload protection, no-volt thermal based release - 02 Nos. (01 No Spare). [b] LT 440 volts 3 phase, 4 wire 50 cycles, 16 kA, Adjustable type MCCB of 63 Amp rated complete with overload protection, no-volt thermal based release - 06 Nos. (02 Nos for fresh water Pump, 01 No for DB-1,01 No for Jockey Pump and 02 No for Spare ]. [c]Star delta starter of capacity 75 HP for electric driven fire pump - 01 Nos. [d] Starter of suitable capacity for electric driven Jockey Pump - 01 Nos [e] LED Indicating Lamps for ech phase with colour code Red Yellow Blue for R, Y and B Phases [f] Multifunctional Intelligent Panel Meter digital type for measuring Volts, Current, Hz, pf, power along with connected CTs.
Supply and fix gun metal Fire brigade inlet connection (sunction collecting head ) consisting of 4 Nos 63mm dia instantaneous male coupling with built in check valves and 150mm dia sluice valve (one no 150mm dia NRV) and 150mm dia flanged outlet complete with all accessories all as specified and directed.
Supply and fix non return valve of 100 mm dia, double flanged conforming to IS 8321 Part-I PN 1.6 complete all as specified ( at tapping of wet riser from ring main, Fire bridge inlets ) and as directed.
Supply and fix non return valve of 150 mm dia, double flanged conforming to IS 8321 Part-I PN 1.6 complete all as specified and as directed.( fire pumps)
Supply and fix non return valve of 80 mm dia, double flanged conforming to IS 8321 Part-I PN 1.6 complete all as specified and as directed.( Jockey pumps)
Supply and fix Air cushioning tank (Air vessel) 250mm dia x 1000mm high with dished top, made of minimum 6mm thick MS pipe /plate complete with 20mm dia. Brass air valve (ball type), 20mm dia stop valve, pressure gauge with brass stop cock, nipple tees elbows and all accessories complete all as specified and as directed.
Supply and fix water pressure gauges of 0-25 kg/sq.cm standard dia at delivery side of pump sets complete with connecting tubing, fitted with stop cocks etc all standard practice all as specified and as directed.
Supply and fix Electrically operated water pressure switch Universal type with necessary mounting/connection with control wiring with conductor and mechanical connection to operate at pressure range of 0 to 10 Kg/sqcm for automation all as specified and as directed.
Supply and fix Gun Metal gate valve of 50mm dia, double flanged confirming to IS 8321 Part-I PN 1.6 complete all as specified and directed.
Supply and fix CI Sluice Valves of 150 mm dia ,double flanged confirming to IS 14846 PN 1.6 complete, all as specified and as directed.
Supply and Fix CI sluice valve of 100 mm dia, double flanged confirming to IS 14846 PN 1.6 complete all as specified and directed.
Supply and Fix CI sluice valve of 80 mm dia, double flanged confirming to IS 14846 PN 1.6 complete all as specified and directed.
Supply and fix flanged end lift type Foot valve 150 mm dia with brass strainer, suitable flanges, nuts, bolts, gaskets complete all as specified and as directed.
Supply and fix flanged end lift type Foot valve 80 mm dia with brass strainer, suitable flanges, nuts, bolts, gaskets complete all as specified and as directed.
Supply and fix MS cabinet (approx 750mm x 600mm x 450mm) to encl fire brigade inlet connections fabricated from 16 gauge sheet with full front glass door and locking arrangement painted and mounted on masonry platform complete all as specified and as directed.
Cutting existing pipeany size/type not lessthan 150mm dia for altrations or additions necessarily done in position without taking down and inserting 'Tee of 150x150x150 mm' and Tee of 100 x 100x 100mm for tapping all as specified and directed.
Supply & Planting carpet Grass by piece turfing including preparation of ground upto 30 cm deep and filling soft soil, cow dung and watering etc complete (loose soil and cow dung will measured separately) by the Engr-in-charge
Supply only approved loose soil best quality for plantation
Supply only approved manure (cow dung) best quality
Supply only approved vermi compost best quality
Supply and plantation of foxtail palm (height of plant not less than 2.0m above ground level) incl preparation of ground up to 30cm deep and filling of good earth, cow dung vermi compost and watering etc complete all as directed by the Engineer-in-charge.
All as per item No.99 above but royal palm of height not less than 1.5 m
Supply, install, test and commissioning of LT Feeder Pillar Box CPRI approved , made out of CRCA sheet 3.15 mm thick outdoor Pedestal type totally enclosed with front and rear opening, hinged doors with projected an raised platform of suitable size weather and water proof with necessary locking arrangements along with lugs, cable glands of various sizes for cables, danger notice plate, strickering of Switcher gear about termination of switch gear, and the nuts/ bolts etc used are to be made of rust proof material incl as per IS: 8623 aluminium bus bar with insulators suitable for three phase and four wire LT AC, 50 Hz 415 V 400 A capacity complete with powder coating, necessary internal electric connection as required and provision of the following:
Incoming:
(a)MCCB AC 3 Phase 415V , 50Hz 4 pole 250A capacity 35KA with microprocessor based-1 No
Outgoing:
a) Adjustable type MCCB 4 pole, 160 Amp 50Hz 415 V with rupturing capacity 25 KA, 4 Nos (Bldg -01, AMF-01 and spare) b) MCCB AC 3 Phase 415 V, 50Hz 4 pole 100 A capactiy 25kA, with adjustable type thermal and magnetic setting relays - 02 Nos ( APFC Panel-01 and spare).
c) Intelligent Panel meter to measure voltage, current, frequency, power factor, etc with all connected CTs
d) LED Indicating Lamps for each phase with colour coed Red Yellow Blue for R, Y and B Phases for each breakers
Supply and installation,testing and commisioning distribution Transformer step down 11/0.433 KV with HT 3 phase and LT 3 phase 4 wire system copper wound with off load tap changing arrangement on HT side for a variation of secondary voltage +/- 7.5% insteps of 2.5% continuous rating of 160 KVA outdoor type conforming to "IS 1180 (Part-1)-2014"with energy efficiency of level 2 with and including the following:-
(a) Lifting lugs/hooks for transformer and tank (b) Earthing terminal rating and diagram plate.(c) Air release device.(d) Oil filling inlet pipe with plug(e) Drain outlet pipe with brass gate valve with dummy plug(f) Conservator with level gauge(g) Silica gel breather(h) First oil fill up upto the recommended level by manufacturer with new oil conforming to IS 335 (j) Type of connection : Delta/Star (k) Type of cooling : ONAN (l) Vector Group : DYN 11(m) Type of connecting arrangement : Cable termination boxes on both HT and LT side (n) Temperature rise over an ambient of 50 degree centigrade maximum (o) All necessary arrangements with devices for measuring the temprature of core, winding and oil. (p) In addition to the above all standard fittings shall be provided as per IS norms
Supply laying & testing cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) with stranded aluminum conductor 11000 volts grade, of size 3 core 95 sq mm.
Material and labour for providing sub-main wiring with 10.0 sqmm nominal area four single core pvc insulated unsheathed multi-stranded FRLS copper conductor cable including one 6.0 sqmm pvc insulated unsheathed multi-stranded copper conductor cable for earth wire drawn through pvc conduit complete all as specified and as directed. Note: Four run of 10.0 sqmm + one run of 6.0 sqmm cable + one run of pvc conduit shall be measured as an one unit.
M&L Submain wiring concealed conduit for single phase supply with PVC insulated FRLS copper conductor cable unsheathed for circuit along with earth wire incl PVC rigid conduit medium grade of suitable size with acessories complete for 2 runs 6.0 sq mm for phase and neutral and 1 runs of 6.0 sq mm green in colour for earth continuity conductor complete all as directed and making good the disturbed area.
M&L Submain wiring concealed conduit for single phase supply with PVC insulated FRLS copper conductor cable unsheathed for circuit along with earth wire incl PVC rigid conduit medium grade of suitable size with acessories complete for2 runs 4.0 sq mm for phase and neutral and 1 runs of 4.0 sq mm green in colour for earth continuity conductor complete all as directed and making good the disturbed area.
Supply and fix cable jointing kit for 11kV grade cable for outdoor termination cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured Al conductor cable of size 95 sqmm
Supply and lay cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of following sizes (a) 3.5 core 240 sqmm
(b) 3.5 core 150 sqmm
b) 3.5 core 120 sqmm
b) 3.5 core 50 sqmm
b) 4 core 16 sqmm
Supply and Install Gang oprated Air break switch for 11000 volts ,200 Amps with two fixed type insulators and movable insulator connected with base operating rod of suitable length and GI pipe arrangment to control from the ground all as specified.
Supply and Fix Lightning arresters 9 KV metal oxide(Gapless type), heavy duty, single pole self supporting as per IEC 99.4,for a rated system voltage of 12KV at 50Hz supply,outdoor type with discharge current of 10 KA (peak) at max residual voltage of 40KVP complete with all fittings,transmissions class II all as specified.
Material and labour aluminium conductor, steel reinforced for two pole structure as specified and as directed
Supply & install steel tubular swaged poles Type 410 SP-31 (11.0 metres long) complete with CI base plate and final including foundation all as specified
APFC Panel with MD-XL capacitor and MCCB as incomer (Auto/ Manual option) with 80 KVAR with 4 steps (4x20KVAR) all as specified and as directed.
Material and labour for earth continuity conductor or main earthing lead made of Galvanised iron strip 32X6mm, fixed to wall on batten or recess or chases or burried in ground or fixed to poles or any other indicated situation including drawing through GI Pipe for earthing etc. complete all as specified and as directed.
Supply & install steel tubular swaged poles Type 410 SP-31 (9.0 metres long) complete with CI base plate and final and single swan neck including foundation all as specified and as directed.
Supply and Spreading clean dry sand over and around the cable protection in trenches , leveled and punned down for cable cusioning in trenches complete all as specified and directed. (Note: Punned thickness only shall be measured.)
Supplying and laying re-inforced precast concrete cable covers, class LV, type 1 with peak, size 250mm x 150mm x 40mm in trenches for cable protection, embossed with "ELECTRIC" on the top surface complete all as specified and directed.
Supplying and laying un-reinforced precast concrete cable covers, class HV, type 1 with peak, size 300mm x 180mm x 40mm in trenches for cable protection, embossed with "ELECTRIC" on the top surface complete all as specified and directed.
M&L for PCC M-15, Type B–1, using (20mm graded stone aggregate) for coping of poles up to 30 cm above ground including necessary form work, and finishing the surface even and smooth without using extra cement PCC coping complete all as specified and as directed.
Supply, install, test and commissioning of LT Panel Board CPRI approved , made out of CRCA sheet 3.15 mm thick outdoor Pedestal type totally enclosed with front and rear opening, hinged doors with projected an raised platform of suitable size weather and water proof with necessary locking arrangements along with lugs, cable glands of various sizes for cables, danger notice plate, strickering of Switcher gear about termination of switch gear,cable connector for connecting multi cables located in cable chamber terminated from the switchergear and the nuts/ bolts etc used are to be made of rust proof material incl as per IS: 8623 aluminium bus bar with insulators suitable for three phase and four wire LT AC, 50 Hz 415 V 200 A capacity complete with powder coating, necessary internal electric connection as required and provision of the following:
Incoming:
a) MCCB AC 3 Phase 415 V, 50Hz 4 pole 160 A capactiy 25KA adjustable type thermal and magnetic setting release - 01 No. Outgoing: a) MCCB AC 3 Phase 415 V, 50Hz 4 pole 125 A capactiy 25KA adjustable type thermal and magnetic setting relays - 02 No.( F/F panel -01 & spare) b) MCCB AC 3 Phase 415 V, 50Hz 4 pole 63 A capactiy 25kA adjustable type thermal and magnetic setting relays - 02 No.( Lift panel -01 & spare) c) MCCB AC 3 Phase 415 V, 50Hz 4 pole 32 A capactiy 25KA adjustable type thermal and magnetic setting release - 02 No.( Street light -01 & spare)
e) Multifunctional panel meter to measure voltage, current, frequency, power factor, kWH, etc with all connected CTs
f) LED Indicating Lamps for each phase with colour coed Red Yellow Blue for R, Y and B Phases
Supply and fix bus bar trunking system for the complete bldg power supply duly insulated three phase of rating 250 Amps, 25 KA 415 Volts aluminium conductor galvanised GI enclosure 0.8mm thick (Non painted) and lightning bus trunking with galvanised steel enclosure (0.45mm thick), non painted through service shaft including end feed unit with MCCB 250 A 25 KA 4P with rotary handle, termination links of bldg comprising of followings:
a) Supply and fix Straight feeder
b) Supply and fix Flange end
c) Supply and fix end cover- 01 Nos (for main riser )
d) Supply and fix Brackets
e) Supply and fix Springs Hangers
f) Supply and fix Fire barrier complete for BBT
g) Supply and fix Adopter Box
h) Supply and fix Copper braided flexible complete for BBT
i) Supply and fix External GI erath strip 32x6 mm
j) Supply and fix 63A 4P lightning trunking - 3 Nos length
k) Supply and fix Flexible elbow as required at site
l) Supply and fix Harizaontal elbow
m)Supply and fix MS 100A center feed Unit with IP55
n)Supply and fix 63A TAP OFF Box prov for MCB
o) Supply and fix End cover for 63A feeder
p) Supply and fix MS Sleeve IP 55-10Nos
q) Supply and fix MS plug point gasket IP 55-10Nos
r) Supply and fix suspenssion bracket all as directed
s) Supply and fix 125 A tap off box with MCCB 63A 4P, 16 KA
t)Supply and fix 250 A 25 KA 4P MCCB
Supply and fix sheet metal encloser ,provision of fixing incoming and out going cables with bus bar for cable connection alluminium bus bar with insulators suitable for three phase and four wire LT AC, 50 Hz 415 V 100 A capacity complete with powder coating, necessary internal electric connection as required and provision of the following:(Block Panel) all as specified and as directed. (For lift machine room) Incomming:- (a) MCCB 63 Amps,25 KA - 01 Nos Outgoing:- (a) MCB 32 Amp,16 KA TP - 03 Nos(for two lift panel + 01 Spare) (b) LED Indicating Lamps for each phase with colour coed Red Yellow Blue for R, Y and B Phases
Boring of holes under road, pavement, hard standing by trenchless technology using ultra sound technique and necessary machine including HDPE pipe of 150 mm dia suitable for 0.4 mpa working pressure all as specified and as directed.
Supply and fix Integral LED street light Luminaire 40 Watts, comprising of epoxy powder coated, Pressure die cast aluminium housing enclosed with glass cover in frame, with suitable size of bracket, nut and bolts, PVC insulated three core flexible cable of suitable size and length duly connected to light fitting complete and including installation and testing all as specified and directed.
Supply and fix Loop in loop out box of FRP made with IP 65 protection of thermoplasic circuit breaker boxes with metric knockouts for cable entry and exit,combi climate Cable Glands of IP 66/ IP 67 for cable entry and Grommets IP 65 for conduit for cable exit with MCB 6 Amps, 10 kA, C Curve Overload and Short Circuit protection, terminals as bus terminals for cable with necessary fixing arrangemets and with cable glands, etc all as specified and as directed.
Supply and fix time switche 415 V, 50 Hz of 20 Amps rating, with contractor fitting inside steel enclosur all as specified and as directed.
Supply and Fix HT cable rout indicator including with PCC all as specified and directed
Masonry plat form for transformer of size 1.5x1.5x1.2 Mtr with RR masonary in CM 1:6, in foundation base 75mm thick PCC M-7.5 type D2 with 40mm graded aggregate and 100mm thick PCC 1:2:4 type B1 with 20mm graded aggregate at top of the platform, 20mm thick plastering in CM 1:6 externally upto 50mm below GL and three coats of white wash including earth work excavation complete and specified and directed by Engineer-in-Charge.
M&L for Painting lines, dashes, arrows, letters, etc. on road surface with hot applied retro reflective thermoplastic paint confirming to MORTH (Clause. 803.40) all as specified with 8% glass beads using special applicator machine with heating arrangement upto 160 Degress C, including cleaning and drying the road surfaces to ensure dust,oil,grease and moisture free surface before applying paint complete all as specified as directed.
S&F PVC (SWR) type-B pipes of dia 160mm single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified and as directed.
Supply and fix single pointed air terminal aluminium rod 12mm dia 300mm long with aluminium box plate of size of 125x125x10mm including necessary fasters fixed for lighting protection with necessary connections to earthing etc. complete all as specified and as directed.
Supply and fix horizontal roof conductor and down conductor of size 25x3 mm Aluminium strip fixed to Walls/ columns/ projections /roof including porcelain blocks/DMC insulator spaced at 1 Mtr interval complete all as specified and as directed.
Supply and fix test point terminal box of size 200 x 100 x 100 mm made out of 2 mm thick hot dip galvanised sheet drilled and screwed including 6 Nos 15 mm long hexagonal head screws complete with test point terminal block made out of Gun metal or Phosphorus Bronze size 75x75x25 mm drilled and screwed including 3 Nos 8 mm dia 25 mm long hexagonal head screws , etc complete. all as specified and as directed.
(a) Fire man switch
(b) Automatic rescue devide (ARD) during power failure including manual operation provision with suitable capacity of battery designed for funnign the lift with full load.
c) Battery operated emergency light (Led ceiling fitting), alarm (speaker for emergency alarm sustem to be fixed) and stop button in car with rechargeable arrangement for battery.
d) Four sleek circular 5 Watt LED light fitting in false ceiling .
e) One Sleek circular PVC heavy duty fan in false ceiling.
f) Aluminium chequered plate (3 mm thick) as flooring joint in chequered palte should not more than one and top covering with granite flooring complete.
g) Non stop button / independent operation.
h) Over load warning indicator both audio and visual type with tripping sustem having relays etc (overload protectin / tripping system).
j) Front landing door of stainless steel mirror finish operations with a minimum time of 10 seconds and up to a maximum time of 30 seconds.
k) Car size shall be conformity with IS-3534-1976 and body to be stainless steel of 16 gauge mirror finish with stainless steel hand rail 38 mm hairline finish.
l) Set of three in number limit swithces at the bottom and top most position of lift hoist ways as specified in IS.
m) Mirror of 4 mm thickness of suitable size as specified.
n) Opening with mirror of 5mm thick 200 x 800 mm size in all the doors (Car/Landing doors).
o) Specification plate with complete details .
p) Contineuos earthing for machine and equipments.
q) Steel wire rope of adequate sixze as per relevant IS and as per manufacturerer specifications.
r) Other standard fixtures and fitting like guide rails, sheaves, counter weights with guards, buffers, gear unit breakes, control panel, locks, governor, car operational panel, power, control and trailing cables complete.
s) Full length display indicator panle.
t) Main drives and control shall be of latest, high effective and low power consumption.
u) Suitable phase reversal relay shall be provided on the controller to protect lift / equipment against phase reversal, phase failure and low voltage.
v) Stainless steel fron opend landing door with small opening for vision of size 200 mm x 800 mm with toughended galss not lkess than 8mm thick.
w) Intercome be connected with nearest security post.
All as per item No.132.00 as above but suitable to carry 13 passengers (884 Kg) at a speed of 1.5 M/sec to serve upto 10 floors (G+9 floors).
Dismanting MCB DB/Main swicthes of any type and any capacity with MCBs complete all a s specified and directed.
Dismanting of earthing of any type complete all a s specified and directed.
Dismanting of light fittings any type complete all a s specified and directed.
Dismanting of street lighting brackets complete all a s specified and directed.
Dismanting of DBs enclosures complete all a s specified and directed.
Taking out Brass Stop cock any type and any position complete all as specified and directed.
Taking out Brass Bib cock any type and any position complete all as specified and directed.
Taking out Brass Shower rose any type and any position complete all as specified and directed.
PHASE -II: SCHEDULE 'A' PART-XVI: MAINTENANCE OF ARBORICULTURE WORKS DURING DEFECT LIABILITY PERIOD OF WORK UNDER PHASE-II Maintenance of Arboriculture as provided under Serial Item No. 95 to 100 of BoQ by weeding, hosing, saucer melding once in every 15 days, planting new plants / grass in place of dead plants / grass of same species and height with out any extra cost to the department and as directed complete for the period of maintenance period of 12(Twevel) Months complete all as specified and as directed. Note: Rate quoted shall be deemed to include for all labour, materials, tools & plants and regular watering, using sprinklers, including supply and spreading / spraying organic manure, chemical fertilizers, pesticides to the required extent complete all as specified.
PHASE -III: SCHEDULE 'A' PART-XVII: COMPREHENSIVE MAINTANCE OF LIFT [13 AND 8 PASSENGERS LIFTS] INCLUDING ARD AND ALL CONECTED COMPONENTS AS PROVIDED UNDER THIS CONTRACT AS PER SERIAL ITEM Nos.132 & 133 OF THIS BOQ / SCHEDULE 'A' PART-XV [i.e. FIRST YEAR AFTER SUCCESSFUL COMPLETION OF DEFECT LIABILITY PERIOD OF WORK ]
(a) Comprehensive maintenance of electrically operated lift for 13 passengers (884 kg) of (G+9 Floors)-01 No. including ARD and all connected components of lift during First Year after successful completion of defect liability period of work.
(b) Comprehensive maintenance of electrically operated lift for 08 passengers (544 kg) of (G+9 floors)-01 No. including ARD and all connected components of lift during First Year after successful completion of defect liability period of work.
PHASE -IV: SCHEDULE 'A' PART-XVIII: COMPREHENSIVE MAINTANCE OF LIFT [13 AND 8 PASSENGERS LIFTS] INCLUDING ARD AND ALL CONECTED COMPONENTS AS PROVIDED UNDER THIS CONTRACT AS PER SERIAL ITEM Nos.132 & 133 OF THIS BOQ / SCHEDULE 'A' PART-XV [i.e. SECOND YEAR AFTER SUCCESSFUL COMPLETION OF DEFECT LIABILITY PERIOD OF WORK ]
(a) Comprehensive maintenance of electrically operated lift for 13 passengers (884 kg) of (G+9 Floors)-01 No. including ARD and all connected components of lift during Second Year after successful completion of defect liability period of work.
(b) Comprehensive maintenance of electrically operated lift for 08 passengers (544 kg) of (G+9 floors)-01 No. including ARD and all connected components of lift during Second Year after successful completion of defect liability period of work.
PHASE -V: SCHEDULE 'A' PART-XIX: COMPREHENSIVE MAINTANCE OF LIFT [13 AND 8 PASSENGERS LIFTS] INCLUDING ARD AND ALL CONECTED COMPONENTS AS PROVIDED UNDER THIS CONTRACT AS PER SERIAL ITEM Nos.132 & 133 OF THIS BOQ / SCHEDULE 'A' PART-XV [i.e. THIRD YEAR AFTER SUCCESSFUL COMPLETION OF DEFECT LIABILITY PERIOD OF WORK ]
(a) Comprehensive maintenance of electrically operated lift for 13 passengers (884 kg) of (G+9 Floors)-01 No. including ARD and all connected components of lift during Third Year after successful completion of defect liability period of work.
(b) Comprehensive maintenance of electrically operated lift for 08 passengers (544 kg) of (G+9 floors)-01 No. including ARD and all connected components of lift during Third Year after successful completion of defect liability period of work.
Note for Sl. Nos.143 to 148: Comprehensive maintenace consists of preventive and breakdown services including replacement of material and labour for major / minor spare parts and consumables like topping of gear oils/grease/door reollers/relays/door belts/gate lock contacts and hardware like bolts and nuts including load testing of lift for satisfactory performence once in a year complete and rate quoted by the tenderer includes for the above Lifts
(ii) Preventive maintance consists of carrying out routine check by skilled personnel as specified in Paticular specifications and as recommened by Engineer-in-Charge and lubricating to all moving parts, topping parts, topping up of oils as per Lubrication Chart including material and labour for all consumable and major / minor spare parts.
(iii) Breakdown maintance consists of attending to the faults that may occur and carrying out necessary repairs to electrical and control circuits and mechanical components of the lift that may occur diring the operation.
(iv) Fortnightly, quarterly maintaince registers shall be maintained and signed by the site engineer and contractor
(v) Load testing shall be arranged by the contractor to the Lift for whose repairs were carriedout as and when directed by Engr -in-Charge.
(vi) All mintenance works carried out by well qualifed tradesman and supervisor of OEM
Venkateswara Electricals
SVS PROJECTS
K KUMAR RAJA PROJECTS P LIMITED
United Sales Corporation
GOPAL TEKNOCON PRIVATE LIMITED
CH.VEERARAGHAVULU CONSTRUCTION PVT LTD
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid