Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.6 LAccepted-Finance | L1 | Accepted-Finance Being L1 | |
| 2 | L2₹8.9 L+₹34,541.50 (4.03%)Rejected-Finance D NO 9 947 66 DOCTORS COLONY SHIVAJI PLEM VISAKHAPATNAM 530017 | VISAKHAPATANAM | ANDHRA PRADESH | 530017 | L2 | Rejected-Finance Being not L1 | |
| 3 | L3₹10.6 L+₹2.1 L (24.1%)Rejected-Finance 121 MADHAV SQUAR OPP AVANTIKA COMPLEX LIMDA LANE JAMNAGAR 361001 | JAMNAGAR | GUJARAT | 361001 | L3 | Rejected-Finance Being not L1 | |
| 4 | L4₹11.2 L+₹2.7 L (31.2%)Rejected-Finance D NO 65 6 500 2 MULAGADA COLONY HIMACHALNAGAR GAJUWAKA VISAKHAPATNAM 530 026 | VISAKHAPATANAM | ANDHRA PRADESH | 530026 | L4 | Rejected-Finance Being not L1 | |
| 5 | Rejected-Technical D NO 38 22 40 NEAR LAKSHMI NARASHIMA THEATER 104 AREA VISAKHAPATNAM 530007 | VISAKHAPATANAM | ANDHRA PRADESH | 530007 | - | Rejected-Technical Not enlisted in requisite category |
Tender Value
₹9.6 L
EMD Value
₹19,200
Closing Date
27 Jun 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Nitesh Kumar Singh, IDSE AEE(Civ)
AGE (I) R and D, NSTL Complex, Visakhapatnam 530027
8452 REPAIRS / REPLACEMENT TO CENTRAL/ PACKAGE TYPE AC PLANTS AND ALLIED WORKS IN VARIOUS TECHNICAL BUILDINGS AT DRDL KALINGA UNDER AGE (I) RnD NSTL, VISAKHAPATNAM
2023_MES_602833_1
AGE I R AND D NSTL VIZAG 8452
Open Tender
Electrical and Maintenance Works
Item Rate
210 days
Visakhapatnam
Class E, category c(i)
7 documents required · 7 mandatory
₹500
AGE I R and D NSTL Visakhapatnam
₹19,200
Yes
20 Jul 2023
13 Jun 2023
29 Jun 2023
13 Jun 2023
27 Jun 2023
20 Jun 2023
Amount
M & L for de-scaling the condenser unit, capacity upto 70 TR by circulating the approved cleaning agent / diluted hydrochloric acid at the appropriate ratio depending up on the scale deposits till removal inside the copper tube by means of circulating the de-scaling chemical through condenser by pressure feeding method after disconnecting condenser water lines, opening the end covers, scraping/cleaning the condenser water tubing, removing the scales and refixing the dismantled part, end cover with 3mm thick rubber gasket set, re-connecting with the system etc. including minor repairs all as specified and as directed.
M & L for cleaning/ servicing the cooling coil/ blower fan of AHU of 140 TR AC plant at VIB - I (2 units) and MCC Bldg (2 units) by air pressure method using air pressure and cleaning the cooling coil with suitable cleaning agent, cleaning the AHU internally/externally, AHU Motors, scraping the corosion parts of AHU, Motors, tray ets complete , remove the scrap and applying two coat of synthetic enamel paint internally and externally to the AHU, Motors including greasing to AHU blower shaft bearing for smooth functioning, cleaning the AHU filter, replacement of unserviceable V belts etc. all as directed. Note:- V belts shall be measured and paid separately as supply only under respective items of this Schedule.
M&L for cleaning/ servicing of cooling tower, FRP type of 140 TR AC (3 x 70 TR) plant, cleaning of PVC/ FRP louvers by scraping inside and outside, cleaning of water tank, cleaning and replacement of damaged/ choked nozzles, replacement of PVC pipe n. exc. 3 mtr in length; arranging, refixing in position of all louvers in correct manner and applying one coat of black bituminous paint inside and outside of water tank, replacement of float valves with new one, cleaning of CT Fan blades, replacement of corroded nuts and bolts as per existing size including replacement of damaged/ broken louvers and unserviceable nozzles all as specified and as directed.
Supply and fixing in replacement of cooling tower fan motor suitable for 70 TR AC plant for 7.5 HP (5.5 KW), 415 volts, 1440 RPM, 50 Hz with suitable fan blade and mounting arrangement with existing cooling tower all as specified and directed by Engr - in - Charge. (Note:- All necessay work for dismantling and fixing of fan blade with material is deemed to be included in quoted rate).
M&L for complete leak testing the entire chiller unit of any capcity upto 70 TR consisting of compressors, condensers, chillers with connected chilled piping, expansion valves and all accessories by flushing out the refrigerant gas present in the system, pumping Nitrogen gas at requisite pressure, locating leak positions, rectifying the leaks, including pressure testing and holding the pressure for 48 Hrs for observation for any pressure drop in the system and flushing out the complete system on rectification of leaks if any, vacuumising & de-hydration the complete system with heavy duty vacuum pump and removal of moisture and other foreign particles from the system complete including checking of all safety controls and parameters, testing & commissioning of the AC plant after charging the refrigerant gas all as directed by the Engineer-in-Charge. [Note: Supply & charging refrigerant gas/ Nitrogen gas will be measured and paid separately]
M & L for de-scaling the condenser units of air cooled screw type AC plants of capacity of 320 TR (2 x 160) TR by circulating the approved cleaning agent / diluted chemical cleaning agent to a container of water. Apply the diluted solution to the condenser by pouring it along the fins. wait for 10 minutes so that the chemical can be absorbed inside the coil. Rinse the coil with water till removal inside the condenser coil, removing the scrap and dry all components, refixing the dismantled part, re-connecting with the system etc. including minor repairs all as specified and as directed.
M&L for complete leak testing the entire chiller unit of any capcity above 160 TR per unit consisting of compressors, condensers, chillers, AHUs with connected chilled piping, expansion valves and all accessories by flushing out the refrigerant gas present in the system, pumping Nitrogen gas at requisite pressure, locating leak positions, rectifying the leaks, including pressure testing and holding the pressure for 48 Hrs for observation for any pressure drop in the system and flushing out the complete system on rectification of leaks if any, vaccumising & de-hydration the complete system with heavy duty vaccum pump and removal of moisture and other foreign particles from the system complete including checking of all safety controls and parameters, testing & commissioning of the AC plant after charging the refrigerant gas all as directed by the Engineer-in-Charge. [Note: Supply only refrigerant gas will be measured and paid separately]
M & L for cleaning/ servicing the cooling coil/ blower fan, Filter of AHUs capacity upto 50 TR plant at VIB - II, MPPTF, ASH - I & ASH - II (4 units) by air pressure method using air pressure and cleaning the cooling coil with suitable cleaning agent, cleaning the AHU internally/externally, AHU Motors, scraping the corosion parts of AHU, Motors, tray ets complete , remove the scrap and applying two coat of synthetic enamel paint internally and externally to the AHU, Motors including greasing to AHU blower shaft bearing for smooth functioning, cleaning the AHU filter, replacement of unserviceable V belts etc. all as directed. Note:- V belts shall be measured and paid separately as supply only under respective items of this Schedule.
Supply and fixing Pre-filters box type with an efficiency rating of 80 to 90% to capture 10 Micron to 25 Micon size particles of synthetic fiber material of the Size of pre - filter 24'' x 24" x 2'' with aluminium frame all as specified and directed by Engr in Charge.
All as per Item 9.00 here-in-above but of size 25'' x 20'' x 2''
All as per Item 9.00 here-in-above but of size 20'' x 20'' x 2'
M & L for disconnecting/ Dismantlig (electrically & mechanically) 3 phase, 440 volts, 50 Hz electrical motor from the monoblock pump set of 5 HP capacity and shifting to workshop, opening the motor end cover, taking out rotor, taking out burnt stator winding, cleaning the stator and rewinding the motor with appropriate gauge, weight and turns of super enamelled copper wire using proper insulating material, varnishing with Class-I varnish, heating/ baking, reassembling the motor completely and brought back to site, fixing back duly coupled with the pump in prope aignment, connecting and testing complete all as specified. Note: Insulation of windng shall be Class 'B' upto 7.5 HP and Class 'F' for 10 HP and above.
M & L for disconnecting/ Dismantlig (electrically & mechanically) 3 phase, 440 volts, 50 Hz electrical motor from the monoblock pump set of 7.5 HP capacity and shifting to workshop, opening the motor end cover, taking out rotor, taking out burnt stator winding, cleaning the stator and rewinding the motor with appropriate gauge, weight and turns of super enamelled copper wire using proper insulating material, varnishing with Class-I varnish, heating/ baking, reassembling the motor completely and brought back to site, fixing back duly coupled with the pump in prope aignment, connecting and testing complete all as specified. Note: Insulation of windng shall be Class 'B' upto 7.5 HP and Class 'F' for 10 HP and above.
M & L for Descaling of entire package AC plant of capacity 3 x 22 TR at K - 4 Bldg Package AC Plant complete condensors (outdoor unit) , evaprators (indoor unit), with connected chilled/gas piping, expansion valves and all accessories complete with descaling chemical and filters with fresh water all as specified and directed.
M & L for Removal of complete corrosion of body and electrical connections of Package Plant 3 x 22 TR (Blue Star) and applying two coats of synthetic enemel paint over a coat of redoxide and fixing with damaging the existing auxilaries/ pipe lines and electrical connections and complete fxing of the compressor / condnser unit fan controll units and testing complete all as specified and directed.
Material & Labour for complete leak testing the entire Package AC plant system consisting of 3 x 22 TR capacity consisting of variour makes for compressors, condensors, evaprators, with connected chilled/gas piping, expansion valves and all accessories complete with Nitrogen gas, locating leaks positions, rectifing the leaks and flushing out the complete system including pressure testing and holding the pressure for 48 Hrs for observation for any pressure drop in the system and rectifying complete and filling the regrigrent gas to desired pressure and testing complete all as directed by the Engr in charge
S & F microprocessor based controller suitable for existing package type AC Plant of bluestar 22 TR capacity for safety operation for controlling temperature using parameters such as phase sequence, voltage, OC Protection, HP/LP Cutouts, Suction/ discharge pressure of compressors, indicating ON/ OFF, trip complete including replacement of control wiring, defective thermostat, pressure cut-outs all as specified and as directed.
Dismantling AHU of 50 TR capacity AC plant carefully by removing side and top panel removing unserviceable blower shaft bearings,removing motor & blower assembly, replacement of new AHU blower shaft and bearings reassembling blower assembly and refixing electric motor & top side panel in original position with new nut bolts washers & shafts keys & checking the shafts balancing & testing for smooth running all as specified and directed
Supply only Wedge (V) Belts B-2253 LP /B87 for compressor & motor/ AHU & motor. [Make: Fenner/ Yule/ ContiTech]
Supply only Wedge (V) Belts B - 95 for compressor & motor/ AHU & motor. [Make: Fenner/ Yule/ ContiTech]
S&F in replacement Single phase preventer Heavy duty relay for protection against single phasing, phase reversal condition, unbalance condition, with inbuilt timer working on 440V, 50Hz power supply complete all as specified and directed. [Make: Minilec 3NA-30-323 or equivalent in Siemens]
S&F Starter Push Button switch with 1 NO + 1 NC complete working on DC/ AC supply up to 16 Amps capacity by removing of the defective unit all as specified and as directed. [Make: L&T ESBEE/ Siemens]
S&F in replacement 4 pole contactors AC operated rating at 415 Volts, AC1 45 Amps rating with 2NO + 2NC auxiliary contacts with operatabe coil voltage 24 volts to 415 volts AC/DC with front/ side mounted Add On blocks as per site requirement. [Make: ABB/ Siemens/ Schneider/ L&T]
All as per Item 24.00 here-in-above but of AC1 rating 30 Amps
All as per Item 24.00 here-in-above but of AC1 rating 60 Amps
S&F in replacement Thermal Overload relay, 18 to 42 Amps, direct mounted on contactors [TA42DU series of make: ABB or equivalent in GE/ L&T]
S&F in repplacement Thermal Overload relay, 22 to 80 Amps, direct mounted on contactors [TA75DU series of make: ABB or equivalent in GE/ L&T]
Supply only Refrigerant gas 'R- 407C' in manufacturer's sealed cylinder.
Supply only Refrigerant gas 'R- 134a' in manufacturer's sealed cylinder. Note (i) Empty cylinder will be returned to contractor on completion of work (ii) Net weight of refrigerant gas shall be measured and paid under these items.
Supply and Replacement of compressor oil for chiller of AC plants of capacity upto 160 TR of Blue star make all as specified and directed by Engr in Charge. NOTE:- Compressor oil will only be used of make recommended by OEM
Supply only Nitrogen gas in manufacturer's sealed cylinder for leak testing. [Note:- (i) Empty cylinder will be returned to contractor on completion of work. (ii) Net weight of refrigerant gas shall be measured and paid.]
S&F 25 mm bore ball brass valves, high pressure, with polythene float and fly nut complete, screwed for iron pipe or brass ferrule and fixed in repairs. [Make: Leader/ Zoloto/ Lakshmi/ Sakthi]
S&F 20 mm bore ball brass valves, high pressure, with polythene float and fly nut complete, screwed for iron pipe or brass ferrule and fixed in repairs. [Make: Leader/ Zoloto/ Lakshmi/ Sakthi]
S&F 15 mm bore ball brass valves, high pressure, with polythene float and fly nut complete, screwed for iron pipe or brass ferrule and fixed in repairs. [Make: Leader/ Zoloto/ Lakshmi/ Sakthi]
S&F in replacement pneumatic safety valve for condensers of central AC plants of capacity of 140 TR. [Make: As recommended by OEM of AC plant]
S&F in replacement flow control limit switch/ sensor as per the existing make/ model complete all as specified and as directed. [Make:As recommended by OEM of AC plant]
Supply and fixing of water pressure meter dial type up to 14 Kg/cm2 complete all as specified and directed. Make: Guru/Danfoss
Supply and fixing of temperature meter dail type with stop valve 0 to 30 degree centigrade with complete acessories by removing of the old unserviceable meter complete all as specified and directed. Make: H- guru / danfoss/ universal
Removal of the damaged HP/LP cut out, supply and fixing of High Pressure cut out on the compressed / pressurised gas lines complete all as specified and directed.
Removing of the defective unserviceable temperature sensor and supply and fixing of temprature sensor / thermostat controller along with necessary controll wiring and acessories. Make: Simens/ Honey well
M&L for dismantling the existing rusted MS pipe line of any size from their existing position including all accessories complete all specified and directed by Eng in charge.
M & L for Insulation of M S Pipe with PUF slab 30 mm thick with and including applying bituminuous compound and GI cladding with 26 gauge GI sheet complete of size 125 mm dia
M & L for Insulation of M S Pipe with PUF slab 40 mm thick with and including applying bituminuous compound and GI cladding with 26 gauge GI sheet complete of size 80 mm dia
M&L for painting the entire air cooled screw/central type AC plants of the following capacities consisting of compressor units, condenser units,control panel, LT Panel (Power supply) , pumps and suction/disharge pipe lines by scrapping and cleaning the old painted surfaces, removing grease/ oil stains with cleaning agents and applying two coats of synthetic enamel paint of approved tint all as specified and as directed. (a) VIB - II, MPPTF, ASH - I & ASH - II Package Plant 300 TR (Blue star)
(b) All as per Item 45.00 here-in-above but MS bldg 60 TR capacity
(c) All as per Item 45.00 here-in-above but central type AC Plant of 140 TR (MCC Bldg) capacity
Taking down cement, any description on wire mesh of Chilled water pipe line etc. including raking out joints, hacking for key, scrubbing down with water all as specified and directed.
M & L for cement plaster of ratio 1:3 Rendering 10mm thick on fair faces of brick work or concrete surfaces all as specified and directed by Engr in Charge.
Supply and fix in replacement Butterfly valve 200 mm dia including taking down u/s existing butterfly valve complete all as specified and directed.
Supply and fix in replacement Butterfly valve 150 mm dia including taking down u/s existing butterfly valve complete all as specified and directed.
Excavation in trenches not exceeding 1.5 metre wide and not exc 1.5 metre in depth for foundation of pole or laying of pipein trenches etc and getting out in hard/dense soil complete all as specified and as directed by the Engr-in-Charge. (for MS pipe)
Returning, filling in, including spreading levelling, watering and well ramming in layers not exceeding 25 cm in soft / loose soil complete all as specified and as directed by the Engineer-in-Charge.
Removing excavated materials to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.5 metre above the starting point all as specified and as directed by the Engineer-in-Charge.
M & L for dismantling the GI duct and Supply , assembly and erection of GI sheet with TDF flange rectangular/square duct made out of 'L' shaped hollow profile, duly factory boxed, incl all accessories such as Corner, Cleat, Carriage bolt, Gasket and appropriate sealant on longitudinal joints etc complete of size 24 Gauge.
Supply only HRC fuses suitable for Screw compressor control panel of capacity 60 TR to 300 TR suitable all as specified and directed.
Taking down unserviceable indication lamp and supply, fix and testing indication lamp (LED type) with showing red, yellow and green in colour of 22.5mm dia monitor on LT panel board suitable for 240V AC supply all as specified and directed. Make :- L&T / Binay
SRIVALLI ENGINEERS
suresh electricals
ANAND ENTERPRISES AND ENGINEERS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .