| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1st₹5.1 LAccepted-AOC GANDHI CHOWK LANSDOWNE 246155 | PAURI GARHWAL | UTTARAKHAND | 246155 | 1st | Accepted-AOC L1 | |
| 2 | 2nd₹6.3 L+₹99,076 (18.5%)Rejected-AOC GANDHI CHOWK LANSDOWNE DISTT PAURI GARHWAL 246155 | LANSDOWNE | PAURI GARHWAL | UTTARAKHAND | 246155 | 2nd | Rejected-AOC L2 | |
| 3 | 3rd₹7.0 L+₹1.6 L (30.7%)Rejected-AOC P O BALASAUR ROAD KOTDWAR OPP PRINCE WEDDING POINT DISTT PAURI GARHWAL KOTDWAR UTTARAKHAND 246149 | PAURI GARHWAL | UTTARAKHAND | 246149 | 3rd | Rejected-AOC L3 | |
| 4 | 4th₹8.7 L+₹3.4 L (62.6%)Rejected-AOC B 50A VIKAS NAGAR EXTN UTTAM NAGAR NEW DELHI 110059 | NEW DELHI | WEST DELHI | DELHI | 110059 | 4th | Rejected-AOC L4 |
Tender Value
₹10 L
EMD Value
₹20,000
Closing Date
14 Apr 2025, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
AGE I Lansdowne
Asst Garrison Engineer (I) Lansdowne, Disst- Pauri Garhwal Pin-246155
REPAIR TO SEWAGE LINES, SEPTIC TANK AND SOAK WELLS AT ZONE I, II AND III AT LANSDOWNE.
2025_MES_701478_1
9015/E8
Open Tender
Civil Works
Item Rate
330 days
AGE I Lansdowne
All as per NIT and Tender Documents
6 documents required · 6 mandatory
₹500
AGE I Lansdowne
₹20,000
Yes
17 May 2025
15 Mar 2025
16 Apr 2025
15 Mar 2025
14 Apr 2025
31 Mar 2025
Amount
Demolition of brick masonry built in cm incl quoins arches pillars etc. complete all as specified and directed.
Demolition of cement concrete, unreinforced in ground floors and paving and not exc 15 cm thick (below or above ground level) complete all as specified and directed.
Demolition of cement concrete, reinforced in any description and in any position not otherwise specifically provided for complete all as specified and directed.
Demolition and breaking up drain pipe (SGSW /reinforced/CI /PVC etc)) of 150 mm nominal bore laid in trenches, set & jointed in cement morter, complete all as specified and directed by the Engr-in-Charge.
Demolition and breaking up drain pipe (SGSW /reinforced/CI /PVC etc)) of 100 mm nominal bore laid in trenches, set & jointed in cement morter, complete all as specified and directed by the Engr-in-Charge.
M & L for 75mm thick Cement concrete type D-2 , 1:4:8 (40mm gradede aggregate) as in sub base complete all as specified and directed.
M & L for brick work with Sub class 'B' bricks straight or curved on plan exc 6m mean radius built in cement mortor 1:4.all as specified and directed by the Engr-in-Charge
M & L for PCC 1:2:4, type B-1, using 20mm graded crushed stone aggregate as in coping, weathering slighly rounded or chamfered angles etc including use of necessary form work complete all as specified and directed.
Taking down cement plaster on stone/brick walls incl raking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed.
M & L for Rendering 15mm thick on brick walling in CM (1:4) ,finished even and smooth w/o using extra cement all as specified and directed.
Excavating in trenches not exceeding 1.5 mtr wide and not exceeding 1.5 mtr in depth for foundation and getting out in hard/dense soil complete all as directed by Engr-in-charge.
Returning filling in soil including spreading, leveling, watering and well ramming in layers not exceeding 25 cm thick complete all as directed by Engr-in-charge.
Removal of excavated soil to a distance exceeding 250m but n. exc. 500 mtr and depositing where directed by Engr-in-charge.
M & L for mild steel TMT bars 10 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and directed.
M & L for Reinforced cement concrete 1:2:4 type B-1 (using 20 mm graded crushed stone aggregate) as in cover slabs set in cm (1:4) including necessary form work all as specified and as directed.
M & L for Salt-glazed stone ware drain pipes laid in trenches and jointed as specified of 150 mm internal dia of pipe complete all as specified and directed.
M & L for Salt-glazed stone ware drain pipes laid in trenches and jointed as specified of 100 mm internal dia of pipe complete all as specified and directed.
M & L for PCC 1:3:6 type C-2 using 40 mm graded crushed stone aggrs as in packing under and haunching against the sides of pipe or as required at site after the pipes are laid over the existing bed and tested for 150 mm bore of pipe all as specified and as directed by the Engr-in-Charge.
M & L for PCC 1:3:6 type C-2 using 40 mm graded crushed stone aggrs as in packing under and haunching against the sides of pipe or as required at site after the pipes are laid over the existing bed and tested for 100 mm bore of pipe all as specified and as directed by the Engr-in-Charge.
Dismantling of PVC/cast iron pipes of 75/100mm jointed in cement mortar Complete all as specified and directed.
M & L for PVC (SWR) pipe single socketed in any length with rubber ring joints fixed/floor, trenches to wall 110mm bore, incl taking down of existing complete all as specified and directed.
M & L for PVC (SWR) pipe single socketed in any length with rubber ring joints fixed to wall/floor 75mm bore, incl taking down of existing complete all as specified and directed.
S & F PVC (SWR) bends any radius 110 mm bore complete all as specified and directed.
S & F PVC (SWR) bends any radius 75 mm bore complete all as specified and directed.
S & F PVC (SWR) Vent cowl 75 mm bore complete all as specified and directed.
S & F PVC (SWR) Vent cowl 110 mm bore complete all as specified and directed.
S & F MS galvanised clamp of size 20x 0.80 mm made out of MS GI sheet suitable for 110/75 mm dia including drilling holes & fixed to wall with nails complete all as specified and directed.
S & F in repairs PVC (SWR) Nahani trap 75 mm dia with grating including jointing with solvent cement complete all as specified and directed.
S & F in repair Vitreous china squatting pan Orissa pattrn size 580x440mm white with integral foot rests including connection to trap and to flushing pipe anti-syphonage pipe etc complete including provn of lime concrete bedding and making good to floor (excluding flushing cistern and flush pipe) complete all as specified and directed.
S & F in repair vitreous china wash down water closet pan (pedestal pattern), white (excluding fixing bolts, flushing cistern and flush pipe) including PVC seat cover complete all as specified and directed.
S&F in repair PVC valve less syphonic action type flushing cistern 10ltr capacity low level, white/coloured with inlet ball valve flaot and handle including bracket (incl.taking down old cistern ) and fixing of PVC flush pipe 32 mm dia and PVC connection pipes complete all as specified and directed.
Dismantling floor, hearth or wall tiling incl cement mortar bedding (but not backing) removing serviceable tiles to store and rubbish off the premises complete all as specified and directed.
S & F glazed ceramic coloured tiles of size 450mmx300mmx 8 to 9mm thick on vertical surface such as skirting, dados, risers to steps etc set & jointed in neat cement slurry and pointed in white or coloured cement to match the colour of tiles over and including 10mm thick cement plaster in CM (1:4) all as specified and directed by Engineer-in-charge. Tiles shall be confirming to IS-15622-2017, Group B III with average water absorption between 10% to 15% length, width and strightness of sides +0.20% (Max deviation) Thickness + 4.0% (Max deviation) straightness of sides and rectangularity +0.15% (Max deviation) surface flatness +0.22% (max deviation). Breaking strength 500 N (Minimum) and minimum 95% tiles shall be free from visible defects complete all as specified and directed. Note :- Shade of the tiles including colour, design and pattern shall be approved by AGE (I)
M & L Non skid light colour ceramic tiles of any design and pattern 7 to 8mm thick (square/rectangular) area of each tile exceeding 0.11 Sqm but not exceeding 0.18 sqm in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match including 15 mm thick screed bed or bedding layer in CM 1:6. finished fair and even for laying floor finishes/tiles etc complete all as specified and directed. Tiles shall be conforming to IS-15622-2006, Group B II with average water absorption between 3% to 6% length, width and strightness of sides +0.10% (Max deviation). thickness + 5.0% (Max deviation). Centre & edge curvature and warpage +0.50% (Max deviation). breaking strength 1000N (Minimum) and minimum 95% tiles shall be free from visible defects complete all as specified and directed. Note :- Shade of the tiles including colour, design and pattern shall be approved by AGE (I)
M & L for Cutting into existing manholes for connecting new drains, making good to walling and rendering, cutting out branch chhanel and making good benching for and forming branch chhanel (1/2 round 3/4section ) in cement concrete 1:2:4 type B-1 smooth finished and reforming benching as required for 150 mm dia of pipe all as specified and as directed.
M & L for Cutting into existing manholes for connecting new drains, making good to walling and rendering, cutting out branch chhanel and making good benching for and forming branch chhanel (1/2 round 3/4section ) in cement concrete 1:2:4 type B-1 smooth finished and reforming benching as required for 100 mm dia of pipe all as specified and as directed.
Opening of manhole covers, taking out sludge from septic tanks, inspection chambers, man holes & septik tank etc. manually or mechanically , of any depth, burrying in nearby pit, distance not exc 50 m including necessary earth work all as specified and as directed by Engr-in-charge.
Cleaning sewage lines, carefully by rodding manually or mechanically between two inspection chambers, manholes or septic tank,dia of pipe is 100 /150 mm bore sewer lines all as specified and as directed by the Engr-in-Charge.
Cleaning of blockage in WCs traps,floor traps,gully traps and CI/PVC pipes fixed vertically with wall / floor up to Ist MH/Chamber etc.manualy by washing out blocked sludge etc. all as specified and directed.
PIONEER REFRIGERATION AND ELECTRICALS (BID ID -3277966)
sunshine engineering (BID ID -3277198)
vineet pal (BID ID -3281524)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .