Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹17.0 LAccepted-AOC 256 MUNDHELA KHURD NEW DELHI 73 | 1 | Accepted-AOC L1 bidder | |
| 2 | 2₹17.0 L+₹1,224 (0.07%)Rejected-Finance | 2 | Rejected-Finance L2 | |
| 3 | 3₹17.2 L+₹23,344 (1.38%)Rejected-Finance 508 1ST FLOOR DR MUKHERJEE NAGAR DELHI 110009 | NORTH | DELHI | 110009 | 3 | Rejected-Finance L3 |
Tender Value
₹19.1 L
EMD Value
₹38,192
Closing Date
5 Jan 2024, 10:00 amClosed
Executive Engineer
Office of the Executive Engineer,EE(Elec) Division,CSPZ, MLUG Car Parking, Asaf Ali Road, Delhi-110002
Improvement of Electrical installations, Wiring and other allied works in proposed skill Lab behind Dean office, Medical College at Hindu Rao Hospital
2023_MCD_179540_1
MCD/TR/9355/2023_6_1_1/1
Open Tender
Electrical Works
Item Rate
90 days
City- SP, CIVIL LINES
2 documents required · 2 mandatory
₹590
₹38,192
14 Mar 2024
28 Dec 2023
5 Jan 2024
28 Dec 2023
5 Jan 2024
29 Dec 2023
Amount
Wiring Work
OD19572/2023-2024:1.3.3 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Group C
OD19573/2023-2024:1.15.3 Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/PVC conduit including dismantling as required. (a) Group C
OD19574/2023-2024:1.5 Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit along with 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
OD19575/2023-2024:19.1 Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CM/M/W) minimum 6.00, Air delivery minimum 210 Cum/Min , 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required.
OD19576/2023-2024: SITC of window type Air conditioner fitted with rotary compressor of 1.5 ton capacity, BEE 5 star rating complete as required.
OD19577/2023-2024:1.27.6. Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc as required. d) 12 Module (200mm X 150mm)
OD19578/2023-2024:1.27.5. Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc as required. c) 8 Module (125mm X 125mm)
OD19579/2023-2024:1.27.4. Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc as required. b) 6 Module (200mmX75mm)
OD19580/2023-2024:1.27.2. Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc as required. (a) 3 Module (125mmX75mm)
OD19581/2023-2024:1.26. Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.
OD19582/2023-2024:1.24.5. Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. d) 6 pin 15/16 amp socket outlet
OD19583/2023-2024:1.24.3. Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. c) 15/16 amp switch
OD19590/2023-2024:2.18. Supplying and fixing 20 amps, 240 volts, SPN industrial type, socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 amps "C" curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.
OD19584/2023-2024:1.24.4. Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. b) 3 pin 5/6 amp socket outlet
OD19585/2023-2024:1.24.1. Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. (a) 5/6 amps switch
OD19586/2023-2024:1.7.2.Wiring for circuit/submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit as reqd. a) 2 x 2.5 sq.mm + 1 x 2.5 sq.mm earth wire.
OD19587/2023-2024:2.10.1. Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required a.Single pole
OD19639/2023-2024:7.7.1 Laying and fixing of one number PVC insulated and PVC sheathed/XLPE power cable of 1.1KV grade of following size on wall surface as required. upto 35 sq. mm ( clamped with 1mm thick shaddle)
OD19640/2023-2024:7.7.2. Laying and fixing of one number PVC insulated and PVC sheathed/XLPE power cable of 1.1 KV grade of following size on wall surface as required . above 35 sq. mm and upto 95 sq. mm ( clamped with 25x3 mm MS flat clamp)
OD19591/2023-2024:2.5.3. Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as required . 12 way (4 + 36), Double door
Cable, LED's
122.1.30:Supply of XLPE insulated PVC sheathed Al. Conductor Armoured Cable 1.1KV grade conforming to IS-7098 of following size:-4C*25 sqmm
122.1.31:Supply of XLPE insulated PVC sheathed Al. Conductor Armoured Cable 1.1KV grade conforming to IS-7098 of following size:-4C*35 sqmm
122.1.33:Supply of XLPE insulated PVC sheathed Al. Conductor Armoured Cable 1.1KV grade conforming to IS-7098 of following size:-4C*70 sqmm
122.1.34:Supply of XLPE insulated PVC sheathed Al. Conductor Armoured Cable 1.1KV grade conforming to IS-7098 of following size:-4C*95 sqmm
122.2.38:S/I/T/C of Surface mounting CRCA housing 36W LED luminaire with acrylic cover diffuser with following specifications including fixing on existing wall/recess with connections as reqd. (a)Total system wattage = 36 watt +/- 5% (b )Luminous efficacy >=95 lumens /watt. (c)Power factor >=0.95
122.2.39:S/I/T/C of LED Tube type luminaire 20 Watt rating complete with polycarbonate housing batten integrated electronic driver prewired with high efficient LEDs with the following:(a) Total system wattage 20 watt +/- 5%(b )Luminous efficacy lumens/watt >=95 (c)Power Factor >=0.95
122.2.112: Supply, Installation, Testing and Commissioning of inverter split air rotary air compressor (R32/R290/R410A refrigerant) 100% copper condenser, rating 2 ton complete with outer unit as required (5 star rated)
122.2.114:S/I/T/C of stand for split AC
122.2.116:S/I/T/C of 5 KVA Voltage Stabilizer having input voltage 150V-270V and output voltage 195-245V
122.2.117:S/I/T/C of copper pipe for split AC
122.2.118:S/I/T/C of Drain Pipe
OD19588/2023-2024:2.2.16 Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections as reqd. 250 A, 36KA, FPMCCB
122.2.126:SITC of wall mounted fan 400mm sweep rated voltage 220-230 AC rated frequency 50HZ speed 1280-1350 RPM with desired color
OD19589/2023-2024:2.2.14 Providing & Fixing following rating and breaking capacity MCCB in the existing cubical panel board including drilling the hole in cubical panel making the connection etc. as required. (a) 125 Amp, 36KA, FPMCCB
M/s Gyan Enterprises
M. CHHIBBA & CO.
Bidder Name
M/s Gyan Enterprises
DEV ENGINEERS
M. CHHIBBA & CO.
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .