Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
Tender Value
Refer Docs
EMD Value
₹15,733
Closing Date
15 May 2020, 6:00 pmClosed
EXECUTIVE ENGINEER ELECTRICAL BSNL
Office of THE EXECUTIVE ENGINEER Electrical BSNL ELECTRICAL DIVISION I Floor Central Telephone Exchange Press Road Statue Trivandrum - 695001 Tele 0471-23 298 66
SITC of 19 Nos. Inverter type 1.5 TR AC units for DTS Ernakulam -14 Nos and DTS Trivandrum - 5 Nos in BSNL Kerala Circle (Rate Contract)
2020_BSNL_46780_1
NIT NO 01_EDT_2020_21
Open Tender
Electrical Works
Item Rate
45 days
Trivandrum and Ernakulam
Please refer Tender documents.
2 documents required · 2 mandatory
₹590
A O Cash Office of GM STR Ernakulam
₹15,733
20 May 2020
5 May 2020
19 May 2020
5 May 2020
15 May 2020
5 May 2020
Amount
PART A: Supply of AC Unit
Supplying of 1.5 TR inverter type split AC unit operating on 230 V, 50 Hz AC supply having nominal cooling capacity of 4500 Kcal/hr (5.2 KW) or better, minimum Indian Seasonal Energy Efficient Ratio (ISEER) of 3.5, minimum 3 star rated filled with R 410/R 32 refrigerant gas,refregerent flow in copper pipes, including supplying of standard lengths (up to 3 mtrs) of external copper refrigerant pipes, thermal insulation material,63 mm PVC flexible pipe,copper cable and flexible drainage pipe as per manufacturer standards etc as per scope, specifications, terms and conditions attached as required. (Make of unit : Panasonic / Universal comfort (voltas) /Hitachi / LG / Carrier / Daikin / Mitsubishi / O-General/ Blue star /Samsung. Units shall be with Rotary compressor of make Matsushita / Hitachi / Toshiba / Carrier / Emerson / LG / Tecumseh / Danfoss / GMCC as per specification ) The firms should offer unit and compressor as per specified makes above only failing which offer is liable to be rejected with full forfeiture of EMD.
PART B : ITC of of AC Unit, Wiring, MCBs & DBs etc
Installation of 1.5 TR inverter type AC unit including outdoor and indoor unit on the existing frame along with fixing of standard quantity of materails Vide item No. I above i/c leak testing, giving electrical connections, testing and commissioning etc, complete as per site requirements.
Supplying and fixing additional copper piping suitable for the above AC units, over and above 3 mtrs. length i/c thermal insulation , 3x2.5 sq.mm ISI marked PVC insulated copper conductor cable (or size as per manufacturer standard) , 63 mm dia. Flexible PVC pipe ,gas charging etc. as required.
Supplying and fixing of powder coated heavy duty iron stand for mounting outdoor unit of the above AC i/c providing necessary hardware support etc complete as required.
S/F of following size of rigid ISI marked pvc pipe with accessories for protection of refrigerent pipe and for drain water i/c connections testing commissioning etc as reqd.
50 mm dia PVC Pipe
20mm dia PVC Pipe
Providing and fixing following sizes of MS angle iron members i/c cutting,welding, painting, etc as reqd
25mmx25mmx 5mm
25 mmX 5mm Flat
Wiring
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.
(a) 2 X 4 sq. mm + 1 X 4 sq. mm earth wire
(b) 4 X 4 sq. mm + 2 X 4 sq. mm earth wire
(c) 4 X 10 sq. mm + 2 X 6 sq. mm earth wire
MCBs & DBs
Supplying and fixing following way, horizontal type three poleand neutral, sheet steel, MCB distribution board, 415 V, onsurface/ recess, complete with tinned copper bus bar, neutralbus bar, earth bar, din bar, interconnections, powder paintedincluding earthing etc. as equired. (But without MCB/ RCCB/ Isolator) (a) 4 way (4 + 12), Double door
Supplying and fixing DP sheet steel enclosure on surface/ recess along with 25/32 A 240 V "C" curve DP MCB complete with connections, testing and commissioning etc. as required.
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C"curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.(a) Single pole
Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.
Supplying and fixing following rating, four pole, 415 V, isolatorin the existing MCB DB complete with connections, testing andcommissioning etc. as required. (a)100 A
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .