Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹10.1 LAccepted-AOC MANNAPARA MONIRAMPUR P O P S BARRACKPORE DIST 24 PARGANAS N KOLKATA 743101 WB | 743101 | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹10.5 L+₹2,475 (0.24%)Rejected-AOC 296 N 183 2 JOGEN GANGULY STREET MONIRAMPUR BARRACKPORE DIST 24 PARGANAS N KOLKATA 700 120 W B | 24 PARAGANAS NORTH | WEST BENGAL | 700120 | L2 | Rejected-AOC High Rate | |
| 3 | L3₹10.6 L+₹18,755 (1.79%)Rejected-AOC 32 LOOTERY MOHAL ORDERLY BAZAR PO BARRACKPORE DIST 24 PARGANAS NORTH KOLKATA 700 120 W B | KOLKATA | 24 PARGANAS NORTH | WEST BENGAL | 700120 | L3 | Rejected-AOC High Rate | |
| 4 | L4₹11.0 L+₹51,042 (4.88%)Rejected-AOC 100 KUNJRA MAHAL SADAR BAZAR PO P S BARRACKPORE DIST 24 PARGANAS N KOLKATA 700120 | KOLKATA | 24 PARGANAS N | WEST BENGAL | 700120 | L4 | Rejected-AOC High Rate | |
| 5 | L5₹11.0 L+₹54,308 (5.19%)Rejected-AOC | L5 | Rejected-AOC High Rate |
Tender Value
₹10 L
EMD Value
₹20,000
Closing Date
28 Dec 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE AF Barrackpore
GE AF Barrackpore Post Barrackpore Dist 24 Parganas North Kolkata 700120
REPAIR / MAINT / REPLACEMENT OF LT FEEDER PILLARS / PANELS AND CONNECTED WORKS AT 6 WING AF UNDER GE (AF) BARRACKPORE
2022_MES_558526_2
8384/BKP/AF OF 2022-23
Open Tender
Civil Works
Item Rate
180 days
GE AF Barrackpore
Class-E,
Category-b(i)
2 documents required · 2 mandatory
₹500
GE AF Barrackpore
₹20,000
Yes
11 Jan 2023
2 Dec 2022
31 Dec 2022
2 Dec 2022
28 Dec 2022
9 Dec 2022
Amount
Material and labour for disconnecting of APFC panel from all incomming / outgoing connection of any capacity, checking the serviceability of all components i.e. existing capacitors, contactors, MCB, MCCB, indicator lights, power factor controller, replacement of burnt out PVC insulated copper wire of existing size, copper thimble, MCB SPN 'C' Series (6-32Amp) 10KA, re-connect the same after throughly clean, and fixed the spare parts and testing complete all as specified and as directed. Note:- Spare parts as required shall be measured & paid separately under respective items as supply only.
Supply only heavy duty resin filled capacitor 440 volt, 3 phase 50 Hz of capacity 5 KVAR complete all as specified and as directed.
Supply only heavy duty resin filled capacitor 440 volt, 3 phase 50 Hz of capacity 7.5 KVAR complete all as specified and as directed.
Supply only heavy duty resin filled capacitor 440 volt, 3 phase 50 Hz of capacity 10 KVAR complete all as specified and as directed.
Supply only heavy duty resin filled capacitor 440 volt, 3 phase 50 Hz of capacity 12.5 KVAR complete all as specified and as directed.
Supply only heavy duty resin filled capacitor 440 volt, 3 phase 50 Hz of capacity 15 KVAR complete all as specified and as directed.
Supply only heavy duty resin filled capacitor 440 volt, 3 phase 50 Hz of capacity 20 KVAR complete all as specified and as directed.
Supply only heavy duty resin filled capacitor 440 volt, 3 phase 50 Hz of capacity 25 KVAR complete all as specified and as directed.
Supply only capacitor duty contactors of cap 5 KVAR rating @ 415 Volt 3 phase (including 1 NO + 1 NC) complete all as specified and as directed.
Supply only capacitor duty contactors of cap 8.5 KVAR rating @ 415 Volt 3 phase (including 1 NO + 1 NC) complete all as specified and as directed.
Supply only capacitor duty contactors of cap for 12.5 KVAR rating @ 415 Volt 3 phase (including 1 NO + 1 NC) complete all as specified and as directed.
Supply only indicator lamp LED type colour (Red/Yellow/Blue/Green of any) complete all as specified and as directed.
Supply only power factor controller of capacity 8 step 440 volt, 3 phase 50 Hz complete all as specified and as directed.
Material and labour for repair to LT feeder pillar box by dismantling of burnt-out cable connections, bus-bars, MCCBs etc and painting to external surfaces with one coat of synthetic enamel paint and re-fixing of bus-bars, replacement of epoxy coated busbar insulators, serviceable MCCBs, all cable connection from busbar to terminals at both ends etc. including patch repair with electric welding for replacement of hinges, refixing of broken doors, replacement of locking arrangement with sliding bolts including PCC for reconstruction of foundation / coping etc. complete all as specified and directed. NOTE : MCCB / cable connector required for replacement and required PCC for reconstruction of foundation / coping will be measured and paid separately under respective items.
Supply only cable connector of length 0.5 m, made out of 35sqmm multistranded copper conductor single core PVC inner sheathed unarmoured cable including copper lugs, copper nut bolts etc., complete all as specified and directed.
Supply only cable connector of length 0.5 m, made out of 25sqmm multistranded copper conductr single core PVC inner sheathed unarmoured cable including copper lugs, copper nut bolts etc., complete all as specified and directed.
Supply only cable connector of length 0.5 m, made out of 16 sqmm multistranded copper conductr single core PVC inner sheathed unarmoured cable including copper lugs, copper nut bolts etc., complete all as specified and directed.
Suplly and fix in repair MCCB, 630 Amps, 4 pole, 415 Volt, 50 Hz, breaking capacity 36 KA, adjustable thermal and magnetic type complete all as specified and directed.
Suplly and fix in repair MCCB, 400 Amps, 4 pole, 415 Volt, 50 Hz, Breaking capacity 36 KA, adjustable thermal and magnetic type complete all as specified and directed.
Suplly and fix in repair MCCB, 320 Amps, 4 pole, 415 Volt, 50 Hz, breaking capacity 36 KA, adjustable thermal and magnetic type complete all as specified and directed.
Suplly and fix in repair MCCB, 250 Amps, 4 pole, 415 Volt, 50 Hz, breaking capacity 36 KA, adjustable thermal and magnetic type complete all as specified and directed.
Suplly and fix in repair MCCB, 160 Amps, 4 pole, 415 Volt, 50 Hz, breaking capacity 36 KA, adjustable thermal and magnetic type complete all as specified and directed.
Suplly and fix in repair MCCB, 4 pole, 125 Amps, 415 Volts, breaking capacity 25 KA, adjustable thermal and magnetic type complete all as specified and directed.
Suplly and fix in repair MCCB, 4 pole, 100 Amps, 415 Volts, breaking capacity 25 KA, adjustable thermal and magnetic type complete all as specified and directed.
Suplly and fix in repair MCCB, 4 pole, 63 Amps, 415 Volts, breaking capacity 25 KA, adjustable thermal and magnetic type complete all as specified and directed.
Suplly and fix in repair switch disconnector fuse unit complete with HRC fuse of capacity 250 Amp, 415 Volt, 4 pole, 50 Hz in open execution type with fuse complete all as specified and directed.
Suplly and fix in repair switch disconnector fuse unit complete with HRC fuse of capacity 200 Amp, 415 Volt, 4 pole, 50 Hz in open execution type with fuse complete all as specified and directed.
Suplly and fix in repair switch disconnector fuse unit complete with HRC fuse of capacity 160 Amp, 415 Volt, 4 pole, 50 Hz in open execution type with fuse complete all as specified and directed.
Suplly and fix in repair on load change over switch (open execution) complete with of capacity 200 Amp, 415 Volt, 4 pole, 50 HZ complete all as specified and directed.
Suplly and fix in repair on load change over switch (SS enclosure) complete with of capacity 100 Amp, 415 Volt, 4 pole, 50 HZ complete all as specified and directed.
Suplly and fix in repair lugs made of aluminium, long barrel size for LT cable size 50 sqmm x 3.5 core with E-bolt hole complete all as specified and directed.
Suplly and fix in repair lugs made of aluminium, long barrel size for LT cable size 70 sqmm x 3.5 core with E-bolt hole complete all as specified and directed.
Suplly and fix in repair lugs made of aluminium, long barrel size for LT cable size 95 sqmm x 3.5 core with E-bolt hole complete all as specified and directed.
Suplly and fix in repair lugs made of aluminium, long barrel size for LT cable size 120 sqmm x 3.5 core with E-bolt hole complete all as specified and directed.
Suplly and fix in repair lugs made of aluminium, long barrel size for LT cable size 185 sqmm x 3.5 core with E-bolt hole complete all as specified and directed.
Suplly and fix in repair lugs made of aluminium, long barrel size for LT cable size 240 sqmm x 3.5 core with E-bolt hole complete all as specified and directed.
Suplly and fix in repair lugs made of aluminium, long barrel size for LT cable size 400 sqmm x 4 core with E-bolt hole complete all as specified and directed.
Material and labour for shifting of indoor / outdoor type LT panel board of any size with all accessories after disconection of outgoing and incomming cables, earth strips etc. and taking away from existing location and re-installation on the P.C.C./ brick platform duly grouted in the new platform constructed within 15 mtr from the existing location including reconnection of all outgoing and incomming cables, complete all as specified and directed. Note:PCC/brick work to be measured and paid under respective items.
Material and labour for applying one coat of synthetic enamel paint by spray painting including preparation of body of panel board of any description complete all as specified and directed.
Demolition of brick work or stone boulder masonry, built in cement mortar including all quoins, arches, pillars etc. complete all as specified and directed.
Demolition/ taking out tiles of any description or thickness in floors, aprons etc. complete all as specified and directed.
Material and labour for brick work with sub class `B` bricks, old size, straight or curved on plan exc 6m mean radius built in cement mortar (1:6) complete all as specified and directed.
Material and labour for cement concrete (1:3:6) type C2 (using 40mm graded stone aggregate) as in kerbs, coping, etc. chamfered edges including necessary formwork if required including demolition of existing cement concrete complete all as specified and directed.
Material and labour for 100mm thick cement concrete (1:4:8) type D2 (using 40mm graded stone aggregate) as in paving / footpath / sub stn) including making the surface clean by cutting any type of vegetation including demolition of old damaged existing PCC surface complete all as specified and directed.
M&L for refixing of old serviceable precast concrete interlocking paver block of any size and type, complete all as specified and directed.
Material and labour for 60mm thick and M-35 Grade machine pressed precast cement concrete interlocking paver blocks of any shape and size confirming to IS-15658-2006 laid over and including 50mm thick sand cushioning complete all as specified and directed.
M/S A. J. CONSTRUCTION
Das and Brothers
BOSE ENTERPRISE INDEX NO.E 106 2010 BKP
Oenix and associates
APOLLO TRADERS
ROY CONSTRUCTION
ONIEL SALES
stage.html
html • 0.06 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .