Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹10.9 LAccepted-AOC | L1 | Accepted-AOC Lowest | |
| 2 | L2₹12.1 L+₹1.2 L (10.7%)Rejected-AOC | L2 | Rejected-AOC Not Lowest | |
| 3 | L3₹12.1 L+₹1.2 L (10.9%)Rejected-AOC LUDHIANA | LUDHIANA | PUNJAB | 141001 | L3 | Rejected-AOC Not Lowest |
Tender Value
₹13.0 L
EMD Value
₹26,100
Closing Date
4 Dec 2024, 1:00 pmClosed
Executive Engineer (Elect.)
Executive Engineer (Elect.), Thapar Hall, PAU, Ludhiana
Providing and Installation of Air Conditioning in Khem Singh Gill Committee room (Directorate of Extention Education) at PAU, Ludhiana
2024_PAU_130244_2
Endst. No. 1973-78 Dated- 22.11.2024
Open Tender
Electrical Works
Multi-stage
183 days
PAU
Please refer Tender documents.
3 documents required · 3 mandatory
₹1,180
₹26,100
Yes
10 Dec 2024
23 Nov 2024
5 Dec 2024
23 Nov 2024
4 Dec 2024
23 Nov 2024
Amount
A. ELECTRICAL ACCESSORIES S/E of LED Tube light highly durable surface mounted with T-8 LED, 20 watt Tubular Lamp and decorative end caps etc. ,with 2 year onste warranty ,complete (Fitting & Tube lamp ) in all respect as desired by Engineer-in-charge (Make: Crompton / Havells / Wipro/ Phillips/ Jaquar)
Supply & Erection of 600mmx600mm 36/40watt recessed mounted LED Fixture with full diffuser with minimum lumens efficiency of 100 Lm/watt with APFC constant current driver for proper driving of LED. The input voltage range shall be150 V to 270V.The LED driver shall be of isolated type with constant current and constant voltage topology to ensure optimum driving of LEDs .The LED driver shall be have minimum 2.5 KV of surge protection including clamps complete in all respect as desired by Engineer-in-charge at site. (Make: Crompton/ Wipro/ Havell's/ Phillips/ Jaquar)
Dismantle existing Air Conditioners , pipes, outdoor units,electrical material wiring,switches etc & shift to desired location complete in all respect as desired by Engineer -In -Charge at site.
S/E and laying of CAT-6 Cable complete in all respect as approved by the Engineer-in-charge at site. ( Make: AMP, Schenider, MOLEX)
B. AIR CONDITIONING S/E of 4.0 TR 4 way inverter Cassette Air conditioner with minimum BEE rating of 3 star should be operate at 52°C Ambient temperature to be installed in grid type false ceiling complete in all respect as desired by Engineer -In -Charge at site. (Make:- O General, Daikin, Hitachi, Mitsubishi, LG)
S/E of copper refrigerant piping(19.6mm*9.53mm) complete with proper 9 mm insulation, fittings, elbow, bends, with supporting arrangement for walls, civil work etc for 4 TR split air conditioner complete in all respect as desired by Engineer -In -Charge at Site. Make:- Totalline,Ryoku,VRV/Maxwell
S/E hard PVC Pipe of 25 mm dia to withstand pressure of 6kg/cm² for drain of Airconditioners complete fitting and duly insulated with 6mm thick Nitrile Rubber insulation complete in all respect as desired by Engineer-In -Charge at Site (Make-: Supreme/ JINDAL/ FINOLEX/ DIPLAST)
S/E hard PVC Pipe of 32 mm dia to withstand pressure of 6kg/cm² for drain of Airconditioners complete fitting and duly insulated with 6mm thick Nitrile Rubber insulation complete in all respect as desired by Engineer-In -Charge at Site (Make-: Supreme/ JINDAL/ FINOLEX/ DIPLAST)
BHATIA ELECTRICALS (BID ID -599579)
RAJNISH ELECTRICALS (BID ID -600554)
RAJNISH ELECTRICALS (BID ID -600554)
HARAMAN ENTERPRISES (BID ID -600728)
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .