Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹80.2 LAccepted-Finance 447 A DHALITITHA BASIRHAT NORTH 24 PARGANAS PIN 743412 WEST BENGAL | BASIRHAT | NORTH 24 PARGANAS | WEST BENGAL | 743412 | L1 | Accepted-Finance L1 | |
| 2 | L2₹80.5 L+₹20,635.89 (0.26%)Rejected-Finance 499 A HELABATTALA BARRAKPORE ROAD N 24 PGS KOLKATA 125 | KOLKATA | NORTH 24 PARGANAS | WEST BENGAL | 125 | L2 | Rejected-Finance L2 | |
| 3 | L3₹80.6 L+₹40,225.19 (0.50%)Rejected-Finance | L3 | Rejected-Finance L3 | |
| 4 | L4₹1.0 Cr+₹24.1 L (30.1%)Rejected-Finance | L4 | Rejected-Finance L4 | |
| 5 | L5₹1.1 Cr+₹28.1 L (35.1%)Rejected-Finance 8 DR ASHUTOSH SARANI KOLKATA WEST BENGAL 700010 | KOLKATA | KOLKATA | WEST BENGAL | 700010 | L5 | Rejected-Finance L5 |
Tender Value
₹77.9 L
EMD Value
₹1.6 L
Closing Date
13 Apr 2023, 6:00 pmClosed
District Project Director Tech DPMU WBADMIP NADIA
At 3rd Floor Administrative Building WRID Road Station Krishnagar Dist Nadia Pin 741101
Installation commissioning and maintenance of 28 NOS 2 HP surface Solar Irrigation pumping system at existing WDS Canal at HINGALGANJ SANDESHKHALI I AND SANDESHKHALI II BLOCK in the district of North 24 pgs under DPMU NORTH 24 PGS WBADMI Project
2023_WRDD_483565_1
01/22-23/NADIA/WBADMIP/PHASE II
Open Tender
CIVIL AND ELECTRICAL WORKS
Item Rate
180 days
NADIA
Please refer Tender documents.
4 documents required · 4 mandatory
₹1.6 L
Yes
22 May 2023
1 Mar 2023
17 Apr 2023
1 Mar 2023
13 Apr 2023
1 Mar 2023
1 Mar 2023 - 22 Mar 2023
Amount
2HP SOLAR PHOTOVOLTAIC Pumping System with Surface Pump
Solar Module: Supply , transport , installation and commissioning of ISI marked as per IS 14286 and IEC 61853(1), 61730(1&2), 61710 certified Solar Module of Monocrystalline PERC/bifacial cell with min. efficiency of 15% and fill factor more than 70%, laminated between sheet of -Ethylene Vinyl Acetate (EVA) and high transmissivity 3.2/4.0 mm tempered glass , framed in anodized aluminium frame .The power output of individual PV modules used in the PV array, under STC, should be a minimum of 300 Watt peak, with adequate provision for measurement tolerances.Modules supplied with the SPV system should have warranty for output wattage, which should not be less than 90% at the end of 10 years and 80% at the end of 25 years. Necessary test certificate also to be supplied. a) For 2 HP Off-grid Solar Water Pumping System with Monocrystallinel PERC SPV modules
Module Mounting Structure ( For 2HP Solar Water Pumping System): Supply , transportation & installation of G.I fixed structure made of MS hollow sections, pipes, plates, angles etc as per IS 1161/1239, 1079/2062, to hold min 540 Wp SPV Module as per drawing and specification of MNRE . The steel structure is to be protected with minimum 80 micron galvanisation(hot dip) and provided the fixed structure making most favorable angle in winter season. The weight of the fixed Module Mounting Structure should be approx. 210Kgs,
Foundation of Module Mounting Structure: Suitable and stable Reinforced Cement Concrete foundation for fixed structure SPV Module structure as per approved drawing. Note:- Rate may vary for different District.
Power conditioning unit with IP54 enclosure : Supply , transport , installation and commissioning of IP 54 protected enclosured Inverter Unit qualifying IEC 61683-Efficiency measurement and IEC 60068-2-Environment Standard , safety standard suitable for 3 Phase A.C. motor, IGBT based high voltage switching inverter with MPPT technology, to take care of the variation of Sun light and will be suitably mounted inside the metal enclosure. Inverter should have protection against Dry run, Over current, Under current, Over voltage, Under voltage, Short circuit etc. System should be able to run at low sunshine and minimum 7 to 8 hours a day run should be possible during normal sunshine.condition. Inverter should have option to auto start for any short trip off due to low light/ cloudy situation except for dry run. Inverter should be provided with a display to show the various parameter by the user such as Voltage, Current, Solar panel DC voltage, Inverter IGBT temperature, Out put AC voltage, Output frequency, Pump flow (direct or calculated method), Irradiation etc . The system should store the data at a set interval, be capable to transfer it to external storage device and support communication of its operational parameters and logs over Modbus protocol . It should also monitor and save total run time, total water pumped etc . There should be provision for interfacing GPRS based data transmission. a) For 2 HP capacity Pump-motor set
Cable and Accessories : Supplying, fitting and fixings of UV rated Copper Cable laid inside HDPE conduit and other accessories as per followings with necessary connection with the Solar PV Module, MPPT etc. i. 4.0 Sq mm single core multi studs - 5m(for 2HP) & 20m(for 3/5 HP) ii. Lugs, HDPE Pipe, Flexible Pipe, Saddle, Cable tie etc a) For 2 HP per structure
Earthing: (IS : 3034) Earthing with 40 mm dia GI pipe 3.64 mm thick 1 x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level as below: By ISI-Medium GI pipe including excavation of soil for installation of Earth Electrode and filling & ramming and connecting to individual structure to earth electrode including S&F 20 mm x 3 mm galvanised (Hot Dip) MS flat on wall/floor with GI saddles as required and connection to equipments incl. drilling holes, with bolts, nuts, washers etc.
Connecting the equipments to earth busbar including S & F GI (Hot Dip) wire of 8 swg on wall/floor with staples buried inside wall/floor as required and making connection to equipments with bolts, nuts, washers, cable lugs etc. as required and mending good damages
Lightning protection (Pole mounted): Lightning protection with 3'' X 1.5" G.I pipe of 3 m + 0.75 mts height with base flange in proper RCC foundation and S & F Lightning Conductor Air Terminal made of 20 mm dia 1000 mm long GI pipe (ISI Medium) having five discharge prongs of 4 SWG GI (Hot Dip) wire at top duly soldered with 7/16 stranded GI (Hot Dip) wire and 85 mm dia 6 mm thick GI base plate at bottom incl. necessary holes etc. Earthing with 65 mm dia GI pipe (Medium) 3.0 Mts. long and 1 x 19/10 stranded GI (Hot Dip) wire (4 Mts. long), 20 mm dia x 125 mm long galvanized bolt, double nuts, double washers including socketing at both ends of stranded GI (Hot Dip) wire by crimping sockets/ thimbles and S & F 65 mm dia GI pipe (ISI-Medium) protection (3 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level to an average depth of 3.65 Mts. (Provision of one lightning protection for each structure)
Supply and installation of 3 phase electromotor pump-motor set suitable for Solar operation covering 5 years warranty for the following conditions including loading, unloading, transportation etc.:- a) 2 HP ISI marked as per IS 9079 surface mounted Monoblock Pump-motor set with 2.60 - 2.78 Lps discharge at 26 mts. total head suitable for 2.0 Ha CCA Sprinkler / Drip operation with foot valve, required quantity of flexible suction pipe(15m), clamps, bend, footvalves and all other accessories to complete connection of suction and delivery side .
Testing and commissioning of scheme after completion of all work
Comprehensive maintenance charges for 4 years beyond 1 year warranty period (which cover monthly inspection, Yearly training to WUA, to attend breakdown within 3 days and to keep the scheme in operation without lapse of time) a) For 2 HP surface pump Note:1 Total comprehensive maintenance charge is to be withheld in addition to Securirty Deposit . Security Deposit will be released after expiry of warranty period of 1 year & Comprehensive maintenance charges will be released @ i) Rs 1.00 for 2 HP, ii) Rs.1.00 for 3 HP, iii) Rs.0.75 for 5 HP Submersible & Surface per Wp per year at the end of each maintenance period i.e.at the end of 2nd year, 3rd year, 4th year, 5th year. In case the “Bidder” does not provide service during the warranty & comprehensive maintenance period, the amount so held up will be forfeited
Insurance @ 2% for Item No. 2, 5, and 10 for a period of 5 years. Note:2 Ist year's Insurance charge is to be paid on production of Original Receipt of premium payment. Remaining 4 years Insurance payment is to be withheld which will be released during 2nd, 3rd , 4th & 5th year on production of Original Receipt of premium payment.
Remote monitoring for 5 years: Provision for remote monitoring for the pumps must be made in the pump controller through an integral arrangement having following basic functions: a. Controller must be assigned with a unique serial number and its live status must be observed remotely on online portal through login credentials. b. Live status must indicate whether controller is ON/ OFF The parameter i.e. the water output, water flow rate, in fault condition, array input voltage/ current, power and motor frequency should at logged at an interval of 10 minutes c. Controller must have a back up to store the data locally ( at least for 1 year) supply & installation of GSM/GPRS based Data Transmitter or Modem and to provide remote monitoring service to transmit the parameters to central server from the solar pumping system with time stamp at user-defined interval and report generation at the buyer end. (Refer Technical Spec.)
Polyester reinforced PVC lay flat Hose pipes. 100mm dia
FOR 01 NOS 2HP SOLAR PHOTOVOLTAIC Pumping System with Surface Pump
FOR 28 NOS 2HP SOLAR PHOTOVOLTAIC Pumping System with Surface Pump
SUPPLIERS SYNDICATE
UJJAL KANTI DAS
EQUIPMENTS AND SPARES AGENCIES
B.K. ENTERPRISE
Bingas Electrical Electronics and Solar System
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .