Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹19.7 LAccepted-AOC | L1 | Accepted-AOC Since L1 admitted | |
| 2 | L2₹20.5 L+₹82,972 (4.21%)Rejected-AOC | L2 | Rejected-AOC Since L2 rejected | |
| 3 | L3₹20.8 L+₹1.1 L (5.67%)Rejected-AOC | L3 | Rejected-AOC Since L3 rejected | |
| 4 | L4₹21.1 L+₹1.4 L (6.95%)Rejected-Finance | L4 | Rejected-Finance Since L4 rejected | |
| 5 | L5₹21.7 L+₹2.0 L (10.3%)Rejected-Finance MAVAZHIKATHU VILA KANNIMEL CHERRY KAVANAD P O KOLLAM 691003 | KOLLAM | KOLLAM | KERALA | 691003 | L5 | Rejected-Finance Since L5 rejected |
Tender Value
₹21.1 L
EMD Value
₹50,000
Closing Date
24 Aug 2024, 6:00 pmClosed
Executive Engineer
Office Of the Executive Engineer Harbour Engineering Division Kollam
building with outer size 8.00mX15.00m with stair room (First Floor) is proposed. The building was proposed as RCC framed structure
2024_HED_685846_1
HED/CEHED/TR/181/2024_5_1_1/1
Open Tender
Civil Works - Buildings
Item Rate
180 days
chavara
Please refer Tender documents.
7 documents required · 7 mandatory
₹2,760
₹50,000
Yes
9 Oct 2024
14 Aug 2024
27 Aug 2024
14 Aug 2024
24 Aug 2024
14 Aug 2024
Amount
Construction of building
2.32:Clearing grass and removal of the rubbish up to a distance of 50 m outside the periphery of the area cleared.
2.6.1:Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.All kinds of soil
60.7.2:DR PACKING Under foundation - Dry stone packing under foundation with good quality blasted rubble including conveyance of material and labour charges etc. complete as per direction of departmental officers at site.
4.1.8:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size)
5.1.2:Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:1:5:3 (1 cement 1.5 coarse sand :3 graded stone aggregate 20 mm nominal size
5.2.2:Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. up tot floor five level excluding cost of centering, shuttering, finishing and reinforcement :1:1.5:3( 1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size)
5.3:Reinforced cement concrete work in beams, suspended floors, roofs, having slope up to 150 landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases up to floor five level excluding the cost of centering, shuttering, finishing and reinforcement, with1:1.5:3 (1 cement : 1.5 coarse sand (Zone III) : 3 graded stone aggregate 20 mm nominal size).
5.22.6:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more
5.9.1:Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete
5.9.5:Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers
5.9.6:Centering and shuttering including strutting, etc. and removal of form for:Columns, Pillars, Piers, Abutments, Posts and Struts
5.9.3:Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platform
50.2.26.1:Filling with contractor own earth (excluding rock) in open areas in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m as per direction of site Engineer-in-charge.
7.1.1:Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) up to plinth level with:Cement mortar 1:6 (1 cement : 6 coarse sand)
50.6.1.2:Solid block masonry using pre cast solid blocks (Factory made) of size 40x20x20cm or nearest available size confirming to IS 2185 part I of 1979 for super structure up to floor two level thickness 20cm and above in: CM 1:6 ( 1 cement: 6 coarse sand) etc complete.
50.10.1:Steel work in built up G I tubular ( round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting,fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete
13.52.1:Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete.On steel work
OD3858/2024-2025:Providing and fixing precoated Aluminium trafford sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.46 mm overall thickness . Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling/self tapping screws of size (5.5x110mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.
Abdul Khalam
G.Rajeevan Pillai
VALIYATHU BUILDERS
T K SANKARA NARAYAN KURUP
Panmana Labour Contract Co-operative Society
Bidder Name
G.Rajeevan Pillai
Abdul Khalam
T K SANKARA NARAYAN KURUP
Panmana Labour Contract Co-operative Society
ABDUL RASHEED
VALIYATHU BUILDERS
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_1067201.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .