Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹38.5 LAccepted-AOC | L1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L2₹43.1 L+₹4.3 L (11.1%)Rejected-Finance 2 B KRISHNA NAGAR AMBALA CANTT | AMBALA | HARYANA | 133001 | L2 | Rejected-Finance Other than lowest bidder | |
| 3 | L3₹57.2 L+₹18.4 L (47.6%)Rejected-Finance 231 JAGGI GARDEN BALDEV NAGAR AMBALA CITY 134003 | AMBALA CITY | AMBALA | HARYANA | 134003 | L3 | Rejected-Finance Other than lowest bidder |
Tender Value
₹50.0 L
EMD Value
₹99,900
Closing Date
12 Nov 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE UTILITY
GE UTILITY AMBALA CANTT 133001
REPAIR MAINT OF DEEP TRUNK SEWAGE LINES IN SECTOR A B AND C UNDER GE UTILITY AMBALA CANTT
2021_MES_481684_1
CA NO GE U AMB 45 OF 2021 22
Open Tender
Civil Works
Item Rate
270 days
GE UTILITY AMBALA CANTT
As per Tender Documents
8 documents required · 8 mandatory
₹500
GE UTILITY AMBALA CANTT
₹99,900
Yes
23 Nov 2021
13 Oct 2021
15 Nov 2021
13 Oct 2021
12 Nov 2021
27 Oct 2021
13 Oct 2021 - 20 Oct 2021
60 days
Amount
Demolition concrete of any description and in any position not otherwise specifically provided for cement concrete (unreinforced) complete all as specified and as directed by Engineer-in-Charge.
Demolition of brick work or stone/boulder masonry, built in cement mortar including all quoins,arches, pillars, etc but excluding ashlar facing, dressed stonework and precast concrete articles complete all as specified and as directed by Engineer-in-Charge.
Excavating in trenches in soft/loose soil and getting out, not exc 1.5 mtr wide and n.exc 1.5 mtr in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n. exc 10 sqm on plan and n.exc 1.5 mtr in depth complete all as specified and directed.
Description all as per item No 3 here in before but exc 1.5m deep & not exc 3.00m deep .
Excavating over areas, n exc 1.5 m deep and getting out in soft/loose soil complete all as specified and directed.
Description all as per item No 5 here in before but exc. 1.5 mtr and not exc.3.00 mtr deep.
Description all as per item No 5 but exc. 3 mtr and not exc. 4.5 mtr deep.
Excavation over areas and getting out complete all as specifieddirected exc. 4.5 mtr and not exc. 6 mtr deep in mud.
Use and waste of timbering as planking and strutting for excavations in trenches in soil, including wales, struts, open poling boards, etc. as may be necessary and fixing and removal n exc 1.5 m deep complete all as specified and directed by Engr-in-Charge.
Description all as per item No 9 here in before but exc. 1.5 mtr and not exc.3.00 mtr deep.
Description all as per item No 9 here in before but exc. 3.00 mtr and not exc. 5.00 mtr deep. Notes for Ser Item No. 3 to 11 : (i) Bailing and Pumping out of water where required shall be carried out as per clause 3.17 & 3.18 of SSR (Part-I) of 2009. (ii) Timbering, planking and strutting if required shall be carried out as per clause 3.24, 3.24.1 & 3.24.6 of SSr (Part-I) of 2009 and paid separetely in item No 10 to 11 as above. (iii) The earth work shall be calculated based on the level register record duly signed by the contractor and Engr-in-Charge. (iv) Sand cushioning/lean conrete will be provided for stablizing of mud strata if required (v) The rates quoted by contractor for Srl Item No. 4 to 8 shall deemed to be included for provisions described in note (i),( ii), (iii),(iv) here-in-before. Nothing extra shall be paid on this account.
Demolition & breaking up drain pipes (Salt glazed ware, AC or Reinforced concrete) set in CM Internal dia of pipe 300 mm
Demolition & breaking up drain pipes (Salt glazed ware, AC or Reinforced concrete) set in CM Internal dia of pipe 250 mm
M&L PCC 1:3:6 type C-2 using 40mm graded curshed stgone agg bed to 300mm dia drain pipes including packing under, & haunching against the sides of pipes after they are laid & tested all as specified as directed by Engr-In-Charge.
M&L 1:3:6 type C-2 using 40mm graded curshed stgone agg bed to 250mm dia drain pipes including packing under, & haunching against the sides of pipes after they are laid & tested all as specified as directed by Engr-In-Charge.
M&L DWC(Double wall corrugated) HDPE pipes of size 300mm (dia) confirming to IS -16098 Part-II of strength/stiffness class SN 8 laid in trenches on conrete bed to level/gradient , jointing as per manufacturers instructions including jointing accessories as required complete all as specified and directed by Engr-In-Charge.
M&L DWC (Double wall corrugated) HDPE pipes of size 250mm (dia) confirming to IS -16098 Part-II of strength/stiffness class SN 8 laid in trenches on conrete bed to level/gradient, jointing as per manufacturers instructions including jointing accessories as required complete all as specified as directed by Engr-In-Charge.
Returning, filling in foundation/trenches including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick in soft/loose soil complete all as specified and directed by Engineer-in-Charge.
Removing surplus excavated soil/materials to a distance not exceeding 100 Mtr and depositing where directed at a level not exceeding 1.5 Mtr from the starting point, complete all as specified and as directed by Engineer-in-Charge.
M&L plain cement concrete 1:3:6 type C-2 using 40mm graded curshed stgone agg, as in foundations filling and mass concrete over rammed earth complete all as specified and as directed by Engineer-in-Charge.
Use and waste of form work to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) plinth beams, and similar work, vertical or to batter (Flat rough finished) complete all as specified and as directed by Engineer-in-Charge.
Use and waste form work to faces of walls, retaining walls, RCC circular manholes, parapets and stair cases rough finished curved surfaces of manholes etc all as specified and directed.
Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings & similar work, not exc. 200mm thick (Horizontal or sloping) Rough finished surfaces of concrete flat complete all as specified and directed.
Formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor & roofs n exc 20 cm wide & sides of RCC/PCC bands in walls, horizintal or sloping & similar work exc 10cm but n exc 20cm wide Rough finished surface of concrete complete all as specified and directed.
S&F mild steel TMT bars 10 mm dia and over cut to length, bent to shape required, including cranking bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and directed.
Description all as per Ser Item No 25 here-in before but 6 mm to 8 mm dia.
M&L RCC M-25 design mix using 20 mm graded crushed stone aggregate in Foundations, including rafts, footings, foundation beams, plinth beams, bases for columns, etc, basement slabs, under-reamed piles and mass concrete all as specified and directed by Engr-in-Charge.
M&L reinforced cement concrete M-25, 20 mm graded crushed stone aggregates (design mix) in walls, retaining walls, basement walls, ballast walls and the like, any thickness; above top of footings, including attached pilasters and buttresses complete all as specified and directed by Engr-in-Charge.
M&L RCC M-25 design mix using 20 mm graded crushed stone aggregate in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs, shelves and the like all as specified and directed by Engr-in-Charge.
Cutting into existing manholes for connecting new drains 200/250mm dia, making good to pipe & rendering, cutting out existing benching for forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-1 smooth finished, reforming benching as required all as specified and directed by Engr-in-Charge.
Cutting existing road incl repairing after laying of pipe line with premix carpet, WBM and hardcore complete as per existing specifications all as specified and directed by Engr-in-Charge.
M&L PCC type B1 (1:2:4) using 20 mm graded stone aggregate in surface channels,benching in sewers,drains etc all as specified and directed by Engr-in-Charge.
Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete using extra cement including forms, moulds, mitred/stopped ends etc complete all specified and directed.
S&F manhole cover SFRC factory made of size 560 mm dia with steel frame heavy duty all as specified and directed.
S&F Rolled mild steel Stairs (framed) including stringers, treades, landing, balusters, hand rails cleats, brackets, etc. complete (GDE Fe 410-W or Grade E-250) complete all specified and directed.
M&L PCC in sub base, foundations, filling and mass-concrete type D2 (1:4:8) using 40 mm graded crushed stone aggregate complete all specified and directed.
M&L Machine pressed precast concrete interlocking paver block (50% grey and 50% coloured) any shape and size confirming to IS 15658-2006 of 60 mm thickness, M-35 Grade with grey cement and no pigment over and including 50 mm sand cushion all as specified and as directed.
Labour only for brick work with sub class ’B’ old size brick (For raising man holes)straight or curved on plan exceeding 6 mtr mean radius built in cement mortar 1:4 complete all as specified and directed by Engr-in Charge. (Bricks shall be used obtained from ser Item No 2 here in before).
M&L 15 mm thick rendering in cement mortor 1:4 with water proofing compound (2% by weight of cement)finished even and smooth without using extra cement on fair faces of brick work or concrete surfaces omplete all specified and directed. (Note- WPC shall be measured and paid separetely)
Supply only water proofing compound.
M & L providing cement concrete (1:2:4) type B1 (20 mm graded crushed stone aggregate) in lintels upto 1.5 m clear span , cills, steps; seimic and other similar bands , plinth courses, string courses, lacing courses, parapets and railing upto 60 cm in height, copings, benching, kneelers, apex stones, bed plates,water troughs and the like including weathering, slightly rounded or chamfered angles and throating and necessary form work complete all as specified and directed.
M&L pre-cast cement concrete 1:2:4 type B-1 (using 20mm graded crushed stone aggregate) as in man hole cover, with plain fair faces including chamfers, weathering throating etc and set in cement mortor (1:4) complete with joint to match including necessary form work complete all as specified and as directed by Engr-in-Charge
Note:- Amount of credit of Rs. 0.00 for retrieved materials as mentioned in Schedule of Credit attached in tender documents in pdf form which will be deducted offline while acceptance of tender.
Puneet Sharma
Bairagi Builders
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .