Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.6 LAccepted-AOC 7 32 1 PRASANTHI NAGAR GOPALAPATNAM VISAKHAPATNAM 530 027 | VISAKHAPATANAM | ANDHRA PRADESH | 530027 | L1 | Accepted-AOC HENCE L1 | |
| 2 | L2₹9.4 L+₹1.4 L (18.1%)Rejected-Finance | L2 | Rejected-Finance HENCE L2 | |
| 3 | L3₹9.7 L+₹1.8 L (22.5%)Rejected-Finance | L3 | Rejected-Finance HENCE L3 | |
| 4 | L4₹12.6 L+₹4.7 L (59.1%)Rejected-Finance D NO 58 22 34 9 PYDIMAMBA NILAYAM BUTCHIRAJUPALEM VISAKHAPATNAM 530 027 | VISAKHAPATANAM | ANDHRA PRADESH | 530027 | L4 | Rejected-Finance HENCE L4 |
Tender Value
Refer Docs
EMD Value
₹23,400
Closing Date
19 Oct 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
NITIN SHARMA
GE SERVICES
COMPRENHSIVE MAINTENANCE OF COOLING APPLIANCES AND CONNECTED WORKS AT DGNP VISAKHAPATNAM
2020_MES_379578_1
GE S TOKEN 08 OF 2020 2121
Open Tender
Electrical and Maintenance Works
Works
240 days
DGNP V GE SERVICE
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
DGNP
₹23,400
1 Jan 2021
22 Sept 2020
21 Oct 2020
22 Sept 2020
19 Oct 2020
5 Oct 2020
22 Sept 2020 - 5 Oct 2020
60 days
Amount
SCHEDULE 'A' PART-II
Repairs and comprehensive maintenance of the cooling appliances like AC's, Water Coolers, Refrigerators etc, including manning and replacement of defective spare parts and making the units functional as per requirement and emergency maintenance complete all as specified and directed by Engineer-in-Charge. Note:- 1. The unit job contains deployement of manpower as mentioned below for 08 hours per day for complete month excluding sundays and holidays. Requirement of manpower on sundays and holidays is required on emergency shall be provided by the contractor at no extra cost to department. 2. The rate deems to be inclusive of periodical maintenance including Chemical cleaning of condenser tubes and cooling coils by cleaning with fresh water there after spraying with diluted caustic soda solution to remove complete scale for window ACs / Split AC's of any capacity all as directed by the Engr-in-Charge. 2. Spare parts will be measured and paid separately under sch 'A' Pt-II,III & IV 3. Approximate No of units are as under:- (a) Split Type AC's =46 Nos (b) Window Type AC's =33 Nos (c )Cassete Type AC's =04 Nos (d) Water Coolers =13 Nos (e) Refrigerators =03 Nos
Refrigeration mechanic (Skilled) - 02 Nos
Helper (Un Skilled) - 02 Nos
SCHEDULE 'A' PART-II
Supply only compressor of following AC's/Water Coolers/Refrigerators all as specified and directed by the Engr-in-Charge, Make- TECUMSEH/KIRLOSKAR/DAIKIN Note:- (i) Desired sound decibel check to be obtained after replacement of sealed compressors. (ii) Warranty of compressor to be of 01 (One) Years and necessary warranty certificate to be submitted. (iii) Gas N-2 for pressure testing, after removing defective compr and fixing re-conditioned compressor
1.5 Ton Window type AC
1.5/2 Ton capacity split/Cassette type AC
40/80 Ltr capacity Water coolers
60/120/150 Ltr capacity water coolers
165/180/230 Ltr Capacity Refrigerator
Supply only Refrigerant R-12/R-22/R-410A/R-134A all as required at site for any type of AC and water coolers/Refrigerators complete all as directed by the Engr-in-Charge. Make Floron/ Hongwell/Dupont
Supply only thermostat 230 V AC suitale for 1.5 Ton Window type AC complete all as directed by the Engr-in-Charge make: RANUTROL/DANFOSS/ INDFORM
Supply only thermostat 230 V AC suitale for Water Cooler of any capacity complete all as directed by the Engr-in-Charge make: RANUTROL/DANFOSS/ INDFORM
Supply only Temperature Sensor with cod assembly 230 V AC suitale for Split type/cassetter Ac of 1.5/2 Ton cap complete all as directed by the Engr-in-Charge make: RANUTROL/DANFOSS /INDFORM
Supply only Air filter suitale for 1.5 Ton/2 Ton split AC as per sample complete all as directed by the Engr-in-Charge.
Supply only copper capiliary tube suitable for window/split type AC's/Water Coolers complete all as directed by the Engr-in-Charge.
Supply only Over load protector suitable for Water Cooler of40/80,60/120/150 Ltrs cap of water Cooler complete all as directed by the Engr-in-Charge. Make: Shriram/Ranutrol
Supply only fan motor capacitor suitable for Water Cooler of40/80,60/120/150 Ltrs cap of water Cooler complete all as directed by the Engr-in-Charge
Supply only fan motor capacitor suitable for W/Type/Split/Cassette type Ac of any capacity complete all as directed by the Engr-in-Charge
Supply only runing capacitor 230 V AC suitable for 1.5 Ton/ ACs of capacity 36/40 mfd complete all as directed by the Engr-in-Charge. Make: SIEMENS/SHARADA/ASIAN
Supply only running capacitor suitable for 1.5/2 Ton split/Cassette type AC of capacity 40mfd & 45 mfd complete all as directed by the Engr-in-Charge. Make: BAJAJ/SHARADA/EPOC/SIEMENS
Supply only running capacitor suitable for Water Cooler of cap 40/80/60/120/150 Ltrs complete all as directed by the Engr-in-Charge
Supply only starting capacitor 80/100 mfd, 230 V AC suitale for 1.5 Ton W/type AC complete all as directed by the Engr-in-Charge. Make: TESLA/SHARADA/ASIAN
Supply only starting capacitor 100/120 mfd, 230 V AC suitale for 1.5 Ton/2 Ton split AC complete all as directed by the Engr-in-Charge. Make: TESLA/SHARADA/ASIAN
Supply only Starting capacitor suitable for Water Cooler of cap 40/80/60/120/150 Ltrs complete all as directed by the Engr-in-Charge
Supply only starting relay suitable for 1.5 Ton Window type AC complete all as directed by the Engr-in-Charge Make: SHRIRAM/RANUTROL/FEDDERS LLOYD
Supply only Starting relay suitable for Water Cooler of cap 40/80/60/120/150 Ltrs complete all as directed by the Engr-in-Charge
Supply only wiring kit for Window type AC's 2.5/4.0 Sqmm copper wire full set including clips complete all as directed by the Engr-in-Charge.
Supply only wiring kit for Split/Cassette type AC of any cap 4.0/6.0 Sqmm copper wire full set including clips complete all as directed by the Engr-in-Charge.
Supply only wiring kit for Water cooler 2.5/4.0 Sqmm copper wire full set including clips complete all as directed by the Engr-in-Charge.
Supply only fan motor blade assembly for window type AC's 1.5 TR complete all as directed by the Engr-in-Charge
Supply only fan motor blade assembly for split type AC's 1.5/2.0 TR complete all as directed by the Engr-in-Charge
Supply only fan blade assembly suitable for 40/80/60/120/150 Ltrs Cap Water coolers complete all as directed by the Engr-in-Charge
Supply only blower drum assembly suitable for 1.5 Ton capacity of window type Acs for any make /model complete all as directed by the Engr-in-Charge.
Supply only blower drum assembly suitable for 1.5/2 Ton Split type AC complete all as directed by the Engr-in-Charge
Supply only fan Motor assembly suitable for 1.5 Ton window type AC complete all as directed by the Engr-in-Charge
Supply only Condenser fan motor assembly suitable for 1.5/2 Ton Split/Cassette type AC complete all as directed by the Engr-in-Charge
Supply only Condenser fan motor assembly suitable for Water cooler of any capacity complete all as directed by the Engr-in-Charge
Supply only front grill for window type Acs suitable for any of make/model as pe sample complete all as directed by the Engr-in-Charge. VOLTAS/VIDEOCON/FEDDERS LLOYD/SAMSUNG
Supply only Swing motor with blade assembly for 1.5 Ton window type Acs complete all as directed by the Engr-in-Charge
Supply only Swing motor with blade assembly for 1.5/2 Ton Capacity split type ACs complete all as directed by the Engr-in-Charge
Supply only Remote assembly kit including PCB Board suitable for 1.5 Ton Cap window Type AC of any make/model complete all as directed by the Engr-in-Charge
Supply only Remote assembly kit including PCB Board suitable for 1.5/2 Ton Cap Split/Cassette Type AC of any make/model complete all as directed by the Engr-in-Charge
Supply only hard drawn copper tube of size 1/2'' for split type ACs 1.5/2 Ton complete all as directed by the Engr-in-Charge .
Supply only hard drawn copper tube of size 1/4'' for split type ACs 1.5/2 Ton complete all as directed by the Engr-in-Charge
Supply only hard drawn copper tube of size 3/8'' for split type ACs 1.5/2 Ton complete all as directed by the Engr-in-Charge
Supply only hard drawn copper tube of size 5/8'' for split type ACs 1.5/2 Ton complete all as directed by the Engr-in-Charge
Supply only PVC drain pipe with clamps set of size 40mm dia upto 2 Mtrs complete all as directed by the Engr-in-Charge
Supply only PVC drain pipe with clamps set of size 20mm dia upto 2 Mtrs complete all as directed by the Engr-in-Charge
Supply only Burntile rubber/foam insulation upto 32mm suitable for split type AC's of any make/model complete all as directed by the Engr-in-Charge
Supply only Cordless Remote suitable for 1.5 Ton Cap window Type AC of any make/model complete all as directed by the Engr-in-Charge
Supply only Cordless Remote suitable for 1.5/2 Ton Cap Split/Cassette Type AC of any make/model complete all as directed by the Engr-in-Charge
Supply only Power Contactor suitable for 1.5/2 Ton Cap Split Type AC of any make/model complete all as directed by the Engr-in-Charge
Supply only Power Contactor suitable for 1.5/2 Ton Cap Cassette Type AC of any make/model complete all as directed by the Engr-in-Charge
Supply only Brass Suction Valve 5/8" suitable for Cassette/Split AC complete all as directed by the Engr-in-Charge.
Supply only Brass Suction Valve 1/2" suitable for Cassette/Split AC complete all as directed by the Engr-in-Charge.
Supply only Brass Discharge Valve3/8" suitable for Cassette/Split AC complete all as directed by the Engr-in-Charge.
Supply only Brass Discharge Valve 1/4" suitable for Cassette/Split AC complete all as directed by the Engr-in-Charge.
Supply only Brass Flare Nut 5/8" suitable for Cassette/Split AC complete all as directed by the Engr-in-Charge.
Supply only Brass Flare Nut 1/2" suitable for Cassette/Split AC complete all as directed by the Engr-in-Charge.
Supply only Brass Flare Nut 3/8" suitable for Cassette/Split AC complete all as directed by the Engr-in-Charge.
Supply only Brass Flare Nut 1/4" suitable for Cassette/Split AC complete all as directed by the Engr-in-Charge.
Supply only PVC sheathed insulated 3 core copper flexible cable of 2.5 Sqmm complete all as directed by the Engr-in-Charge.
Supply only PVC sheathed insulated 3 core copper flexible cable of 4 Sqmm complete all as directed by the Engr-in-Charge.
Supply only Sheet Metal Enclosure with Single pole and neutral with two pin and earth plug and socket complete with one single pole MCB 20 Amps complete all as directed by the Engr-in-Charge
Supply only Copper condensing coil suitable for existing Split AC's 1.5/2 Ton of any capacity complete all as directed by the Engr-in-Charge
Supply only Copper cooling coil suitable for existing Window AC's 1.5/2 Ton of any capacity complete all as directed by the Engr-in-Charge
Dismantling of Voltage stabilizer of capacity 4/5 KVA from position and rewinding the same at workshop and replacement of worn out parts of the stabilizer and fixing the same to the existing position and tesing for proper outgoing of the stabilizer as per satisfaction of engineer-in-charge
Supply and fixing of new Voltage stabilizer for 1.5/2 Ton window / split type ac in repairs for input range 170 to 240 Volt and output 230 Volt all as per direction of engineer-in charge
Supply and fixing of split AC 1.5 ton indoor unit with necessary remote complete incl taking down old unserviceable one and deposited to Store. All as specified and directed by Engr-in-charge. Make - Blue Star/Voltas/Hitachi/LG
Supply and fixing of split AC 1.5 ton outdoor unit with necessary fixing arrengments complete incl taking down old unserviceable one and deposited to Store. All as specified and directed by Engr-in-charge. Make - Blue Star/Voltas/Hitachi/LG
Supply and fixing of split AC 2 ton indoor unit with necessary remote complete incl taking down old unserviceable one and deposited to Store. All as specified and directed by Engr-in-charge. Make - Blue Star/Voltas/Hitachi/LG
Supply and fixing of split AC 2 ton outdoor unit with necessary fixing arrengments complete incl taking down old unserviceable one and deposited to Store. All as specified and directed by Engr-in-charge. Make - Blue Star/Voltas/Hitachi/LG
SCHEDULE 'A' PART-III
Annual Comprehensive Maintenance for Water Purifier of any make/model including replacement of defective spare parts and making the units functional as per requirement and emergency maintenance complete all as directed by the Engr-in-Charge. Note:-Spare parts will be measured and paid separately
Supply only PCB (Power Circuit Board) suitable for any make/model of Water Purifier complete all as directed by the Engr-in-Charge.
Supply only Filter candle suitable for any make/model of Water Purifier complete all as directed by the Engr-in-Charge.
Supply only Carbon for Filter suitable for any make/model of Water Purifier complete all as directed by the Engr-in-Charge.
Supply installation, commissioning water purifier (RO+UF+UV+TDS control) fixed on wall equip with hydro static tank of cap 15 Ltr/hr including with all accessories complete all as specified and directed. Make- KENT/Aquaguard/Livpure
Supply only Inlet Pipe 15 mm with nuts & washers suitable for any make/model of Water Purifier complete all as directed by the Engr-in-Charge.
Supply only Outlet Pipe 15 mm with nuts & washers suitable for any make/model of Water Purifier complete all as directed by the Engr-in-Charge.
Supply only Filter bowl including clamps suitable for any make/model of Water Purifier complete all as directed by the Engr-in-Charge.
R AND A ASSOCIATES ENGINEERS CONTRACTORS
VARADHI ENTERPRISES
P VENKATA RAO
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .