Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.0 LAdmitted-Finance | ₹2.0 L | L1 | Admitted-Finance |
| 2 | L2₹2.1 LAdmitted-Finance | ₹2.1 L | L2 | Admitted-Finance |
| 3 | L3₹2.1 LAdmitted-Finance | ₹2.1 L | L3 | Admitted-Finance |
| Sl No | Description | Qty | Unit | M/S ISHAN ELECTRICAL and MECH. ENGG. WORKS L1 | VEE AUTO TRADERS L2 | M/S UK MECH AND ELECT ENGG WORKS L3 |
|---|---|---|---|---|---|---|
| 2.00 | Repairs of Air Conditioning System of 17 TR capacity DX coil and Air Handling Unit including allied works Eye Operation Theatre of GMC&H, Jammu by way of dismantling of the damaged scroll compressor – 01 No. of 8.5 TR capacity from package Outer unit after closing all required valves, disconnecting all electrical connections from the main panel and disengaging all piping connections etc. The job includes replacement of damaged/sheared ducting sheet of 24 SWG in the AHU about 65 sq.ft with new one by unlocking/dismantling 2 sides of the AHU for making access for working in the AHU Chamber. Then removing/taking out the blower carefully in open area so that repairs works can be carried out. The damaged sheet of blower is carefully taken out from its position and fixing of the new sheet of same guage at its place is done with help of interlocking joints and screws. The job includes taking out the damaged blower and sending it to workshop for realigning of its shaft and replacing its wobbled bearings .Then the blower is assembled and sent at site . The job includes replacement of damaged 01 No Motor of Outer Unit with new one of 7.5 HP capacity. The job also includes replacement of damaged copper pipes of size 7/8” and ½” dia about 10 ft length along with insulations and copper elbows, copper sockets etc from the OD ductable units in the designated area by way of Brazing process. The job includes leak detection test by filling Nitrogen gas in the system at the pressure of 1.5 times its operating pressure. The entire Unit is first tested at low pressure to make sure there are no leaks in system and then at high pressure. This pressure testing is repeated until there are no more leaks, flushing the lines and then making electrical connections. Replacement of 63 Amp MCCB 01No, contactors 02 No’s and Connecters 02 No”s, air filters 04 No’s and both pulleys along with V-Belts in place of damaged ones and also replacement of damaged internal wiring of panel and testing and commissioning of the unit on full load. Complete job includes cost of material, taxes, skilled labour charges, to and fro charges and all types of taxes etc. Complete Job. | 1 | job | 0.02 ₹2.0 L | 0.01 ₹2.1 L | 0.01 ₹2.1 L |
Tender Value
₹2.1 L
EMD Value
₹5,000
Closing Date
26 Feb 2026, 4:00 pmClosed
XEN MECHANICAL AND HOSPITAL DIVISION JAMMU
XEN MECHANICAL AND HOSPITAL DIVISION JAMMU
Repairs of Air Conditioning System of 17 TR capacity DX coil and Air Handling Unit including allied works Eye Operation Theatre of GMCH, Jammu
2026_PWDJK_303629_1
MHDJ/e-NIT 363 of 2025-26
Open Tender
Repair and Maintenance Services
10 days
GMCH JAMMU
as per e nit
2 documents required · 2 mandatory
₹200
XEN MECHANICAL AND HOSPITAL DIVISION JAMMU
₹5,000
29 Apr 2026
17 Feb 2026
27 Feb 2026
17 Feb 2026
26 Feb 2026
21 Feb 2026
17 Feb 2026 - 26 Feb 2026
Select, Excess (+), Less (-) Less (-)
Tender Inviting Authority: Executive Engineer, Mechanical & Hospital Division GMCH Jammu.
Repairs of Air Conditioning System of 17 TR capacity DX coil and Air Handling Unit including allied works Eye Operation Theatre of GMC&H, Jammu
MHDJ/e-NIT 363 of 2025-26 Dated: 17.02.2026 Due : 26.02.2026
Sl. No. Item Code / Make Quantity Units Estimated Rate Addition / Deduction Rate including GST to be quoted by the bidder Rs. P Currency Convertion against each Item Quoted Currency in INR / Other Currency Rebate on old parts in Percentage (%) if any Excise Duty VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category Net Cost of item Rs. P
2 Repairs of Air Conditioning System of 17 TR capacity DX coil and Air Handling Unit including allied works Eye Operation Theatre of GMC&H, Jammu by way of dismantling of the damaged scroll compressor – 01 No. of 8.5 TR capacity from package Outer unit after closing all required valves, disconnecting all electrical connections from the main panel and disengaging all piping connections etc. The job includes replacement of damaged/sheared ducting sheet of 24 SWG in the AHU about 65 sq.ft with new one by unlocking/dismantling 2 sides of the AHU for making access for working in the AHU Chamber. Then removing/taking out the blower carefully in open area so that repairs works can be carried out. The damaged sheet of blower is carefully taken out from its position and fixing of the new sheet of same guage at its place is done with help of interlocking joints and screws. The job includes taking out the damaged blower and sending it to workshop for realigning of its shaft and replacing its wobbled bearings .Then the blower is assembled and sent at site . The job includes replacement of damaged 01 No Motor of Outer Unit with new one of 7.5 HP capacity. The job also includes replacement of damaged copper pipes of size 7/8” and ½” dia about 10 ft length along with insulations and copper elbows, copper sockets etc from the OD ductable units in the designated area by way of Brazing process. The job includes leak detection test by filling Nitrogen gas in the system at the pressure of 1.5 times its operating pressure. The entire Unit is first tested at low pressure to make sure there are no leaks in system and then at high pressure. This pressure testing is repeated until there are no more leaks, flushing the lines and then making electrical connections. Replacement of 63 Amp MCCB 01No, contactors 02 No’s and Connecters 02 No”s, air filters 04 No’s and both pulleys along with V-Belts in place of damaged ones and also replacement of damaged internal wiring of panel and testing and commissioning of the unit on full load. Complete job includes cost of material, taxes, skilled labour charges, to and fro charges and all types of taxes etc. Complete Job. job Excess(+) Full Conversion INR
Total in Figures
Quoted Rate in Figures Select
Please Enable Macros to View BoQ information
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.57 MB
BOQ_986030.xls
BOQ • 0.28 MB
Download all tender documents and submit your bid