| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Admitted-Finance | Admitted-Finance |
| 4 | Admitted-Finance KARUKAPPILLY THATTATHUKUDIYIL BUILDING KOLENCHERY 682311 | KOLENCHERY | ERNAKULAM | KERALA | 682311 | Admitted-Finance |
| 5 | Admitted-Finance | Admitted-Finance |
Tender Value
₹12.2 L
EMD Value
₹24,400
Closing Date
25 Apr 2025, 6:00 pmClosed
Director
NIT Calicut, NIT Calicut Campus PO, Kerala, 673601
Proposal for lighting up the cricket nets and pathway and electrical renovation of the pavilion
2025_NITC_855662_1
Engg/EMU/JEII/015/12th Mile Ground/2024-25
Open Tender
Electrical Works
Item Rate
75 days
NIT Calicut, NIT Calicut Campus PO, 673601
Please refer Tender documents.
4 documents required · 4 mandatory
₹0
₹24,400
Yes
8 May 2025
4 Apr 2025
28 Apr 2025
4 Apr 2025
25 Apr 2025
4 Apr 2025
Amount
WIRING IN STEEL & PVC CONDUIT
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.
Group C
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.
2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
2 X 4 sq. mm + 1 X 4 sq. mm earth wire
4 X 16 sq. mm + 2 X 6 sq. mm earth wire
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.
3 x 2.5 sq. mm
3 x 4 sq. mm
Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required.
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required.
6 Module (200mmX75mm)
8 Module (125mmX125mm)
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required.
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required.
MCCB, MCB & DB'S
Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required.
125A, 16kA, 4 pole , 415 V MCCB
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
12 way , Double door
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MOB DB complete with connections, testing and commissioning etc. as required.
Single pole
Triple pole
Supplying and fixing single pole blanking plate in the existing MOB DB complete etc. as required.
Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Supplying and fixing 40 A to 63 A rating, 415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MOB DB complete with connections, testing and commissioning etc. as required.
Supplying and fixing 40 A to 63 A rating, 240 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
40-63 A Double pole
40-63 A Single pole
Supplying and fixing 3 phase following way double door, suface/recess mounting, vertical type, 415 V, TPN distribution board with provision for fixing MCCB as incomer and TP MCB as out going, complete with 200 A tinned copper bus bar, common neutral link, earth link, din bar for mounting MCBs, detachable gland plate, interconnections, earthing, phosphatized and powder painted, fixing using bolt and nut, giving connections etc. as required. (But without MCCB, MCB)
Outdoor box
Supplying and fixing of weather proof outdoor junction box for outdoor installation of size 205 x 255 x 112 mm^3 with knockouts for cable entry including din bar, suitable connectorsfor connecting Al cable to copper cable of suitable size, provision for fixing one number of single pole MCB, wether proof Grommets, glands, clamps, screws of required length fastners connections for surface/ recess fixing etc. as required.
EARTHING
Supply and laying of one number 8 SWG good quality bare copper conductor for loop earthing along with existing XLPE insulated PVC sheathed armoured power cable as required.
Earthing with G.I. earth pipe 2.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement, watering pipe and with suitable amount (30kg) of earthing compound (EXCEL compound or equivalent) etc. as required.
MV CABLE LAYING
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation and refilling the trench etc as required, but excluding sand cushioning and protective covering.
Upto 35 sq. mm
Laying of one number additional PVC insulated and PVC sheathed! XLPE power cable of 1.1 KV grade of following size direct in ground in the same trench in one tier horizontal formation including excavation and refilling the trench etc as required, but excluding sand cushioning and protective covering.
Upto 35 sq. mm
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.
Upto 35 sq. mm (clamped with 1mm thick saddle)
MV CABLE JOINTING & END TERMINATION
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.
2 X 10 sq. mm (19mm)
2 X 16 sq. mm (22mm)
Supplying and making end termination with copper reducer/bottle lugs/terminal lugs for following size of PVC insulated copper stranded cable of 1.1 KV grade as required.
MISC. CIVIL ITEMS
Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. in the existing trench, complete as required.
63 mm dia (00-63 mm & ID-51 mm nominal)
Pole foundation
Concreting with 45 x 45 x 100 cm up to ground level and 40 cm above ground level using 8 mm steel reinforcement as per drawing with cement concrete of 1:2:4, after excavation and plastering the sides including a neat cement flushing coat,tapering the top of the plinth for prventing water setting. painting with cement paint, fixing concealed PVC/DWC pipe for incommer cable etc, as required.
Supply and fixing of 40 mm class B, GI pipe including painting on the wall wall, complete connections, testing and commissioning etc as required.
Supply, fabrication, conveyance of 32 mm class B, GI pipe cut and welded to shape fixing the same to wall including painting, suitable iron clamps, nuts, bolts, washers etc on the wall / parapet using suitable clamps, painting, making good the damages,etc as required.
Pump Accessoroes
Supplying nylone rope 12mm thick suitable for supporting submesible pump for use in borewell.
Supply of 32mm HDPE Pipe withstanding 8Kg Pressure
Laying of one number 32mm HDPE Pipe (8Kg) direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.
Installation testing commitioning of submersible pump including connecting HDPE pipe to the pump using horse shoe clamp, attaching rope to the pump. (Pump will be supplied by the institute)
Installation testing commitioning of submersible pump starter including connecting, clamping etc as required. (Starter will be supplied by the institute)
Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLOC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CM/M/W) minimum 6.00, Air delivery minimum 235 Cum/Min , 380 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required.
ELECTRICAL FIXTURES
Indoor Lighting
Supply and fixing of following LED Luminaires
18/20 watt 4 feet T8 LED tube with efficacy 100lm/W. (T8 LED-Crompton LGT8-20-865-2 or compatible)
Box type tube fittings (Batten ), complete with side holders etc, as required.(Batten- Crompton ECO DIJB12LT8-20 1XT8 or compatible)
LED Bulk head Luminaires 10W (Crompton SUNRISE, LBHE-10-WW/T/CDL or equvalent) with Efficacy >100 lm/W, CCT>3400K (WW/CDL/T) ANSI, IP 65 Protected.Including necessory clamps, screws, fastners etc. as required.
Outdoor Lighting
Supply, installation, testing and commissioning of 200 W LED flood light fitting made of pressure die-cast aluminium housing, with optimal heat sink, with a rated life of L70 @50000 Hours, CRI> 70 % with system efficacy greater than or equal to 120 lumens/.watts, PF>0.95, THD @240 V AC <10% , built in surge protection 4 KV and external surge protection 10 KV the light fitting shall be with all required accessories suitable for mounting in arm.with heat resistant toughened clear glass and weather proof gasket for LEDs and control gear compartments, IP 66. LED specification make- Bajaj/Equivalent ,colour temp- 5000K to 6000K. Input AC voltage range 140V-280V , driver efficiency >85% . with all accessories complete with connection etc as required.(Bajaj model PRAZE F 240L WH ND-A5 TG SD/Equivalent)
Supply, installation, testing and commissioning of 45 W LED street light fitting made of pressure die-cast housing, with optimal heat sink, with a rated life of L70 @50000 Hours, CRI> 70 % with system efficacy greater than or equal to 120 lumens/.watts, PF>0.95, THD @240 V AC <10% , built in surge protection 4 KV and external surge protection 10 KV the light fitting shall be with all required accessories suitable for mounting in arm.with heat resistant toughened clear glass and weather proof gasket for LEDs and control gear compartments, IP 66. LED specification make- Bajaj/Crompton/Philips or Equivalent ,colour temp- 5000K to 6000K. Input AC voltage range 140V-280V , driver efficiency >85% . with all accessories complete with connection etc as required.(Bajaj model NEXO 54L WH PO PC SD/Equivalent)
Poles
Supplying and fixing of Hot dipped Galvanised continously tapered octagonal pole made from 3 mm thick sheet of overall length 8 Metre, Provision for fixing flood light fitting with 330 x 275 x 85 mm size MS 'C' channel of 240 cm length, supporting with two numbers of 32mm GI pipe (class 'B') neatly welded to the C channel at the top of the pole and an adjustable base plate of required size and gauge for fixing the light fitting , with standard arm cap. The bottom dia of the pole shall be minimum 130 mm and top 70 mm with inbuilt cable loop in loop out box with flush door and locking facility. The pole shall be with base plate of 200x200x12mm and 4 Nos M24 x 600 mm long foundation bolt. The Pole should be with c type clamp welded on the top for connecting the safety belt. The pole shall be mounted on suitable size foundation and provision for fixing 3 Nos of 6-32A SP C curve MCB for phase distribution for each circuit and thereby load balancing, loop in loop out 3 phase terminals block, required dia PVC/DWC pipe in the foundation for taking cable in & out from the pole, 4Cx2.5 sqmm flexible unarmoured PVC insulated round copper cable from loop in loop out to light fixture, 6-32A SP C curve MCB(3 circuit per pole ) etc with all required accessories. (The cost of the civil foundation is not considered in this item.)
Supplying and fixing of Hot dipped Galvanised continously tapered octagonal pole made from 3 mm thick sheet of overall length 6 Metre, Provision for fixing flood light fitting with 330 x 275 x 85 mm size MS 'C' channel of 240 cm length, supporting with two numbers of 32mm GI pipe (class 'B') neatly welded to the C channel at the top of the pole and an adjustable base plate of required size and gauge for fixing the light fitting , with standard arm cap. The bottom dia of the pole shall be minimum 130 mm and top 70 mm with inbuilt cable loop in loop out box with flush door and locking facility. The pole shall be with base plate of 200x200x12mm and 4 Nos M24 x 600 mm long foundation bolt. The Pole should be with c type clamp welded on the top for connecting the safety belt. The pole shall be mounted on suitable size foundation and provision for fixing 3 Nos of 6-32A SP C curve MCB for phase distribution for each circuit and thereby load balancing, loop in loop out 3 phase terminals block, required dia PVC/DWC pipe in the foundation for taking cable in & out from the pole, 4Cx2.5 sqmm flexible unarmoured PVC insulated round copper cable from loop in loop out to light fixture, 6-32A SP C curve MCB (3 circuit per 6 mtr. pole ) etc with all required accessories. (The cost of the civil foundation is not considered in this item.)
CABLE
Supply of PVC/ XLPE Aluminium Armoured Cable, 650/1100V. Grade confirming to IS:7098 (Pt-1)1988
2x10 Sq.mm
2x16 Sq.mm
Supplying and fixing of following size ISI marked PVC insulated and PVC unsheathed copper single core and multi-core shaethed bright annealed bare copper flexible cables for voltage grade 1.1 KV grade as required.(Make:Finolex,RR cable,KEI or equvalent) including necessory clamps, screw etc. as required.
3x1.5 sqmm
LABOUR
Removing of following items and handing over to EMU safely.
Removing tube light and fixture with/with out rad/clamp from cealing/wall handing over to EMU store safely as required.
Removing cealing fan with rad, regulator from switch board, handing over to EMU store safely including stacking of fan leafs as required.
Removing of point wiring including cealing rose, conduit, wires, switches(modular/piano type) switch board, clamps etc. as required and handing over to the store/yard.
Removing of submain wiring including conduit, wires, clamps etc. as required and handing over to the store/yard.
Removing of Vertical type TPN MCCB/MCB DB including connections MCBs MCCB's, Insulating open terminals etc. as required and handing over to the store/yard.
LAMOS TECHNOLOGY SOLUTIONS PVT LTD (BID ID -3206415)
MAHESH KR (BID ID -3206538)
Sivaprathapan KB (BID ID -3206634)
Power Care Electrical (BID ID -3206629)
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .