| 1 | L1₹21.0 LAccepted-AOC | L1 | Accepted-AOC Being L1 bidder | |
| 2 | L2₹22.6 L+₹74,484 (3.40%)Rejected-Finance | L2 | Rejected-Finance Being other than L1 bidder | |
| 3 | L3₹25.6 L+₹3.7 L (17.1%)Rejected-Finance | L3 | Rejected-Finance Being other than L1 bidder |
Tender Value
₹36 L
EMD Value
₹72,000
Closing Date
5 Nov 2024, 6:00 pmClosed
GE 862 EWS
GE 862 EWS Rajouri
REPAIR REPLACEMENT OF PUMP, MOTOR, STARTER, CONTROL PANELS, APFC PANELS AND CONNECTED WORK AT RAJOURI UNDER AGE EM OF GE 862 EWS
2024_MES_670604_2
GER-50/2024-25
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE 862 EWS Rajouri
As per NIT
9 documents required · 9 mandatory
₹500
GE 862 EWS
₹72,000
Yes
25 Nov 2024
11 Oct 2024
7 Nov 2024
11 Oct 2024
5 Nov 2024
19 Oct 2024
11 Oct 2024 - 18 Oct 2024
Amount
Disconnecting the 150 HP centrifugal pump of any make from the motor after disconnection of mechanical tyre coupling, suction/discharge pipe line and unbolting from foundation base plate, loading/unloading of pump on vehicle and transportation of the pump from E/M installation to workshop as directed by Engineer-in-Charge for repair/replacement/maintenance of unserviceable parts including strip opening and dismantling of pump for repair, with necessary oiling and greasing and again transportation of the pump through vehicle from workshop to E/M installations after necessary repair/ replacement/ maintenance and loading/ unloading the pump and re-coupling the pump with motor on base frame, after checking of the alignment with motor, testing, commissioning complete all as directed by Engr-in-Charge.
S&F of mechanical seal/ gland packing suitable for 150 HP capacity pump, complete all as specified and directed
S&F of bronze impeller suitable for 150 HP capacity pump, complete all as specified and directed
S&F of neck ring suitable for 150 HP capacity pump, complete all as specified and directed
S&F of bush suitable for 150 HP capacity pump, complete all as specified and directed
S&Fof CI key suitable for 150 HP capacity pump, complete all as specified and directed
S&F of pump sleeves suitable for 150 HP capacity pump, complete all as specified and directed
S&F of stainless steel shaft suitable for 150HP capacity pump, complete all as specified and directed
S&F of pump coupling complete by drilling grinding etc for 150HP capacity pump, complete all as specified and directed
S&F of pump casing for 150 HP capacity pump, complete all as specified and directed
S&F of impeller lock nut for 150HP capacity pump, complete all as specified and directed
S&F of water deflector for 150HP capacity pump, complete all as specified and directed
S&F of oil seal for 150HP capacity pump, complete all as specified and directed
S&F of stuffing box for 150HP capacity pump, complete all as specified and directed
S&F of bearing housing for 150HP capacity pump, complete all as specified and directed
Disconnecting the 40 to 50 HP centrifugal pump of any make from the motor after disconnection of mechanical tyre coupling, suction/discharge pipe line and unbolting from foundation base plate, loading/unloading of pump on vehicle and transportation of the pump from Rajouri E/M installation to workshop as directed by Engineer-in-Charge for repair/replacement/maintenance of unserviceable parts including strip opening and dismantling of pump for repair, with necessary oiling and greasing and again transportation of the pump through vehicle from workshop to Rajouri E/M installations after necessary repair/ replacement/ maintenance and loading/ unloading the pump and re-coupling the pump with motor on base frame, after checking of the alignment with motor, testing, commissioning complete all as directed by Engr-in-Charge.
S&F of mechanical seal/ gland packing suitable for 40 to 50 HP capacity pump, complete all as specified and directed
S&F of bronze impeller suitable for 40 HP to 50 HP capacity pump complete all as per specified and directed.
S&F of neck ring suitable for 40 HP to 50 HP capacity pump complete all as per specified and directed.
S&F of bush suitable for 40 HP to 50 HP capacity pump complete all as per specified and directed.
S&F of CI key suitable for 40 HP to 50 HP capacity pump complete all as per specified and directed.
S&F of pump sleeves suitable for40 HP to 50 HP capacity pump complete all as per specified and directed.
S&F of stainless steel shaft suitable for40 HP to 50 HP capacity pump complete all as per specified and directed.
S&F of pump coupling complete by drilling grinding etc for 40 HP to 50 HP capacity pump complete all as per specified and directed.
S&F of pump casing for 40 HP to 50 HP capacity pump complete all as per specified and directed.
S&F of impeller lock nut for 40 HP to 50 HP capacity pump complete all as per specified and directed.
S&F of water deflector for 40 HP to 50 HP capacity pump complete all as per specified and directed.
S&F of oil seal for 40 HP to 50 HP capacity pump complete all as per specified and directed.
S&F of stuffing box for 40 HP to 50 HP capacity pump complete all as per specified and directed.
S&F of bearing housing for 40 HP to 50 HP capacity pump complete all as per specified and directed.
Disconnecting the 15 to 30 HP centrifugal pump of any make from the motor after disconnection of mechanical tyre coupling, suction/discharge pipe line and unbolting from foundation base plate, loading/unloading of pump on vehicle and transportation of the pump from Rajouri E/M installation to workshop as directed by Engineer-in-Charge for repair/replacement/maintenance of unserviceable parts including strip opening and dismantling of pump for repair, with necessary oiling and greasing and again transportation of the pump through vehicle from workshop to Rajouri E/M installations after necessary repair/ replacement/ maintenance and loading/ unloading the pump and re-coupling the pump with motor on base frame, after checking of the alignment with motor, testing, commissioning, complete all as directed by Engr-in-Charge.
S&F of mechanical seal/ gland packing suitable for 15 to 30 HP capacity pump, complete all as specified and directed
S&F of bronze impeller suitable for 15 HP to 30 HP capacity pump complete all as per specified and directed.
S&F of neck ring suitable for 15 HP to 30 HP capacity pump complete all as per specified and directed.
S&Fof bush suitable for 15 HP to 30 HP capacity pump complete all as per specified and directed.
S&F of CI key suitable for 15 HP to 30 HP capacity pump complete all as per specified and directed.
S&F of pump sleeves suitable for 15 HP to 30 HP capacity pump complete all as per specified and directed.
S&F of stainless steel shaft suitable for 15 HP to 30 HP capacity pump complete all as per specified and directed.
S&F of pump coupling complete by drilling grinding etc for 15 HP to 30 HP capacity pump complete all as per specified and directed.
S&F of pump casing for 15 HP to 30 HP capacity pump complete all as per specified and directed.
S&F of impeller lock nut for 15 HP to 30 HP capacity pump complete all as per specified and directed.
S&F of water deflector for 15 HP to 30 HP capacity pump complete all as per specified and directed.
S&F of oil seal for 15 HP to 30 HP capacity pump complete all as per specified and directed.
S&F of stuffing box for 15 HP to 30 HP capacity pump complete all as per specified and directed.
S&F of bearing housing for 15 HP to 30 HP capacity pump complete all as per specified and directed.
Disconnecting the 5 to 10 HP centrifugal pump of any make from the motor after disconnection of mechanical tyre coupling, suction/discharge pipe line and unbolting from foundation base plate, loading/unloading of pump on vehicle and transportation of the pump from Rajouri E/M installation to workshop as directed by Engineer-in-Charge for repair/replacement/maintenance of unserviceable parts including strip opening and dismantling of pump for repair, with necessary oiling and greasing and again transportation of the pump through vehicle from workshop to Rajouri E/M installations after necessary repair/ replacement/ maintenance and loading/ unloading the pump and re-coupling the pump with motor on base frame, after checking of the alignment with motor, testing, commissioning, complete all as directed by Engr-in-Charge.
S&F of mechnical seal/ gland packing suitable for 5 to 10 HP capacity pump, complete all as specified and directed
S&F of bronze impeller suitable for 5 to 10HP capacity pump complete all as per specified and directed.
S&F of neck ring suitable for 5 to 10HP capacity pump complete all as per specified and directed.
S&F of bush suitable for 5 to 10HP capacity pump complete all as per specified and directed.
S&F of CI key suitable for 5 to 10HP capacity pump complete all as per specified and directed.
S&F of pump sleeves suitable for 5 to 10HP capacity pump complete all as per specified and directed.
S&F of stainless steel shaft suitable for 5 to 10HP capacity pump complete all as per specified and directed.
S&F of pump coupling complete by drilling grinding etc for 5 to 10HP capacity pump complete all as per specified and directed.
S&F of pump casing for 5 to 10HP capacity pump complete all as per specified and directed.
S&F of impeller lock nut for 5 to 10HP capacity pump complete all as per specified and directed.
S&F of water deflector for 5 to 10HP capacity pump complete all as per specified and directed.
S&F of oil seal for 5 to 10HP capacity pump complete all as per specified and directed.
S&F of stuffing box for 5 to 10HP capacity pump complete all as per specified and directed.
S&F of bearing housing for 5 to 10HP capacity pump complete all as per specified and directed.
M&L for rewinding with super enamelled copper winding wire of existing gauge/ size / quality to match with the existing as comply including all insulating material such insulating paper, sleeves, varnish etc drying the copper winding after varnish with blower or heater including soldering all internal connection and testing complete all as specified and directed.
M&L for replacement of ball bearing No SKF/NBC-6303 to 6307 for motor including refixing of nuts, bolts, washer and sleeves etc, complete all as specified and directed.
All as per srl item No-62 here in before but ball bearing No SK/NBCF-6308 to 6311, complete all as specified and directed.
All as per srl item No-62 here in before but ball bearing No SKF/NBC-6312 & 6313, complete all as specified and directed.
All as per srl item No-62 here in before but roller bearing No SKF/NBC-NU-6314 to 6319, complete all as specified and directed.
All as per srl item No-62 here in before but roller bearing No SKF/NBC-NU-7307 & 7308, complete all as specified and directed.
All as per srl item No-62 here in before but roller bearing No SKF/NBC-NU-7309 to 7311, complete all as specified and directed.
All as per srl item No-62 here in before but roller bearing No SKF/NBC-NU-319, complete all as specified and directed.
Lifting out and lowering of submersible pump set Capacity 03 HP to 25 HP of any make from bore well for carrying out repair in civil workshop including transportation and dismantling/repair of pumpset by taking out old unserviceable parts and lowering the same after repair/replacement and testing complete all as directed. (Note : Spare parts of pump/motor i.e. ball bearing, stainless steel shaft, bush, cast iron keys, re-winding wire of new super enamelled coper wire of existing gauge/size/quality will be measured and paid separately under respective items.)
M&L for cutting and removing burnt winding of submersible motor of capacity of 3 HP, rewinding of motor with super enamelled subersible copper winding wire of original gauge and size including insulation etc & testing, complete all as specified and directed. Note: The rate quoted above this item including copper winding complete.
M&L for cutting and removing burnt winding of submersible motor of capacity of 25 HP, rewinding of motor with super enamelled subersible copper winding wire of original gauge and size including insulation etc & testing, complete all as specified and directed. Note: The rate quoted above this item including copper winding complete.
S&F for neck ring of submersiable pump of 3HP capacity of any make, complete all as specified and directed
S&F for coupling for pump and motor of submersiable pump of 3HP capacity of any make, complete all as specified and directed
S&F for stainless steel sleave for pump shaft of submersiable pump of 3HP capacity of any make, complete all as specified and directed
S&F for bowl assembly of any size pump of submersiable pump of 3HP capacity of any make, complete all as specified and directed
S&F for impeller of submersiable pump of 3HP capacity of any make, complete all as specified and directed
S&F for body bush of submersiable pump of 3HP capacity of any make, complete all as specified and directed
S&F for stainless steel shaft of submersiable pump of 3HP capacity of any make, complete all as specified and directed
S&F for neck ring submersiable pump of any make capacity of 25 HP, complete all as specified and directed
S&F for coupling for pump and motor of submersiable pump of 3HP capacity of any make, complete all as specified and directed
S&F for stainless steel sleave for pump shaft of submersiable pump of 25HP capacity of any make, complete all as specified and directed
S&F for bowl assembly of any size pump of submersiable pump of 25HP capacity of any make, complete all as specified and directed
S&F for impeller of submersiable pump of 25HP capacity of any make, complete all as specified and directed
S&F for body bush of submersiable pump of 25HP capacity of any make, complete all as specified and directed
S&F for stainless steel shaft of submersiable pump of 25HP capacity of any make, complete all as specified and directed
S&F for old/ existing burnt/ worn out contact point for fixed and moving type contact suitable size/ shape for star delta starter of 15 to 40 HP capacity motor complete all as specified
Description all as per srl item No-84 here-in-before but capacity of motor 50 HP, complete all as specified and directed.
Description all as per srl item No-84 here-in-before but capacity of motor 100 HP to 150 HP, complete all as specified and directed.
M&L for cleaning, scrubbing the surface to remove dust and rust of pump motor set and iron base frame inclusive of one primer coat, one under coat and one finishing coat of smoke grey paint to pump set and black paint to iron base frame to the pump set of any capacity in different location any capacity, complete all as specified and directed.
S&F for replacement of broken cooling fan of centerifugal motor capacity 150 HP, make kirloskar as per existing fitted, complete all as specified and directed by Engr-in-Charge.
Supply and applying grease LG-240/280 as requirement for centerifugale pump, complete all as specified and directed by Engr-in-Charge. (Make Castrol/HP/Gulf)
Supply,laying, jointng and testing, XLPE insulated, armoured heavy duty electric cable with aluminium conductor 1100 volts grade of size 70 Sqmm 3.5 core laid in trenches, ducts, pipes, on poles and connection with necessary cables lugs, glands nut bolts including removing old unserviceable cable complete all as specified and directed. (Note :- Excavation of earth work, removing, returning filling in, sand cushoining, concrete cable cover and protection GI pipe shall be measured and paid separetly and length of calbe shall be one length unless otherwise as directed by GE)
Supply,laying, jointng and testing, XLPE insulated, armoured heavy duty electric cable with aluminium conductor 1100 volts grade of size 150 Sqmm 3.5 core laid in trenches, ducts, pipes, on poles and connection with necessary cables lugs, glands nut bolts including removing old unserviceable cable complete all as specified and directed. (Note :- Excavation of earth work, removing, returning filling in, sand cushoining, concrete cable cover and protection GI pipe shall be measured and paid separetly and length of calbe shall be one length unless otherwise as directed by GE)
Excavation in trenches not exc 1.5m wide and and not exc. 1.5m depth wide in hard/dense soil for laying electric cables/pipes etc including getting out excavated earth and trimming the sides and bottoms of trenches complete all as specified and directed.
Supply and filling sand for cushioning of cable protection in two layers ie. First layer 18cm before laying of cable and second layer 15 cm thick after laying of cable in trenches/ duct including spreading, levelling, punning down complete all as specified and directed.
M&L for brick covering with width equal to length of brick as mechanical protection to cable using sub class ‘B’ bricks laid flat, size 230mm x 115mm x 75mm, complete all as specified and as directed.
Returning, filling in including spreading, leveling, watering and well ramming in layers not exc. 25cm in hard and dence soil complete all as specified and directed.
Removal of surplus soil to a distance not exc. 50m and depositing where directed at a level not ex. 1.5m above the starting point complete all as specified and directed.
S&F in replacement for On/ off load change over switch of sheet steel enclosure confirming SS Enclosure, front operated four Pole 415 V, 50 Hz of Capacity 100Amps, complete all as specified and directed.
S&F in replacement for On/ off load change over switch of sheet steel enclosure confirming SS Enclosure, front operated four Pole 415 V, 50 Hz of Capacity 160 to 200 Amps, complete all as specified and directed.
S&F in replacement for On/ off load change over switch of sheet steel enclosure confirming SS Enclosure, front operated four Pole 415 V, 50 Hz of Capacity 400Amps, complete all as specified and directed.
S&F in replacment of change over switch of schnider model No Easy Pact CVS630F 50/60 HZ Cat Part No A IEC/EN 60947-2 4 Pole 415 V, as per existing make and size fitted at Div Pump of capacity 630 AMPS, complete all as specified and directed.
S&F in repair moulded case circuit breakers with fixed thermal magnetic setting. MCCB 3Pole, 100 Amps, 36KA, 415 V, 50 Hz, complete all as specified and directed. .
S&F in repair for moulded case circuit breakers with fixed thermal magnetic setting. MCCB 3Pole, 125 Amps, 36KA, 415 V, 50 Hz, complete all as specified and directed.
S&F in repair for moulded case circuit breakers with fixed thermal magnetic setting. MCCB 3Pole, 160 Amps, 36KA, 415 V, 50 Hz, complete all as specified and directed.
S&F in repair for moulded case circuit breakers with fixed thermal magnetic setting. MCCB 3Pole, 200 Amps, 36KA, 415 V, 50 Hz, complete all as specified and directed.
S&F in repair for moulded case circuit breakers with fixed thermal magnetic setting. MCCB 4Pole, 200 Amps, 36KA, 415 V, 50 Hz, complete all as specified and directed.
S&F in repair for moulded case circuit breakers with fixed thermal magnetic setting. MCCB 4Pole, 250 Amps, 36KA, 415 V, 50 Hz, complete all as specified and directed.
S&F in repair for moulded case circuit breakers with fixed thermal magnetic setting. MCCB 4Pole, 400 Amps, 36KA, 415 V, 50 Hz, complete all as specified and directed.
S&F in repair for moulded case circuit breakers with fixed thermal magnetic setting. MCCB 4Pole, 630 Amps, 36KA, 415 V, 50 Hz, complete all as specified and directed.
Earthing complete with galvanised steel earth plate electrode 600x600x6mm thick burried directly in ground earth pit not less than 2.25m deep below ground level with top edge of the plate not less than 1.5m deep below normal ground level connected to and including 32X6mm thick galvanised iron strip by means of bolts, nuts, checknuts and washers of galvanised iron or steel all as specified in electrical plate No 3 of SSR (2009) part-I including 40mm bore GI pipe light grade for protection of earth strip and PCC 1:2:4 type B-1 as in pit, Precast RCC earth pit cover 8 cm thick reinforced with 8mm dia TMT bars @150mmc/c and two handles, excavation and earth work in any type of soil and alternate layers of charcoal, common salt and 20mm bore galvanised medium grade steel tubing for watering with one end fixed with cast iron funnel and wire mesh and testing on completion complete inclulding taking down existing unserviceable earthing all as specified and directed. (Note:-Earth strip and protection pipe upto 7.5mtr is included in the rate quoted)
S&F for galvanised iron strip 32x6 mm buried in ground and on wall surface as per site requirement (for additional earthing lead beyond 7.5 meters per earth, if so required at site ) and interconnection of earth pits complete including removal of old unserviceable all as specified and directed.
S&F in repair for DOL starter, AC 3 phase, 415 Volt, 50 Hz with sheet metal enclosure type suitable for 7 HP motor including making connection complete all as sepcified and directed.
S&F in repair for fully Automatic Star-delta starter, AC 3 phase, 415 Volt, 50 Hz with voltage & ampere meter, sheet metal enclosure type suitable for 10 HP motor including making connections, complete all as specified and directed.
All as per srl item No 112 above but for 30 to 35 HP motor, complete all as specified and directed.
All as per srl item No. 112 above but for 50 HP motor, complete all as specified and directed.
All as per srl item No. 112 above but for 150 HP motor, complete all as specified and directed.
M&L in repair for mild steel work including cutting, bending to shape, welding drilling holes, jointing by nuts, bolts, washers etc using MS chanel, equal angle, flat iron, sheet steel etc including two coats of synthetic enamel paint over a coat of red oxide primer, complete all as directed.
S&F in repair for 20 mm bore gun metal gate valve (ISI marked) heavy duty with iron wheel head, screwed both ends for GI iron pipe, complete all as specified and directed.
All as per serial item No-117 here-in-before but size 25 mm bore, complete all as specified and directed.
M&L in repair of aluminium tubular lugs of size 95 Sqmm to 120 Sqmm (cable size), complete all as specified and directed.
M&L in repair for painting of pump control panel internally as well as external surfaces complete with two coat of synthetic enameled paint over a coat of red oxide primer of approved colour including of preparation of old surface of panel, complete all as specified and directed.
M&L for 16 Sqmm, 3 core submersible copper conductor multistranded cable, LT 1100volt grade,water proof lowering with the column pipe into the bore/ well and testing complete after taking down old unserviceable cable, complete all as specified and directed.
M&L for 10 Sqmm, 3 core submersible copper conductor multistranded cable, LT 1100volt grade,water proof lowering with the column pipe into the bore/ well and testing complete after taking down old unserviceable cable, complete all as specified and directed.
Supply and laying or fixing or passing through pipe, 1100 volts grade heavy duty cable with PVC insulated multi strand copper conductor cable size 70 Sqmm, single core unsheathed flexible complete after taking down old unserviceable cable all as specified and directed.
Supply and laying or fixing or passing through pipe, 1100 volts grade heavy duty cable with PVC insulated multi strand copper conductor cable size 35 Sqmm, single core unsheathed flexible complete after taking down old unserviceable cable all as specified and directed.
Supply, installation, commissioning and testing of LT Feeder pillar of size 2Mx2Mx0.60M (3.15 mm MS Sheet) factory made (CPRI approved), outdoor cubical compartmental type, double door, both side openable with hinged doors & locking arrangement, outgoing cable chamber with same rated aluminium strip from cable chamber to MCCB output, made out of 3.15 mm thick mild steel CRCA sheet supported and fixed on structural frame of angle iron of size 50 x50 x 6mm angle iron frame including painting to all internal & external exposed steel surfaces with powder coating paint (5 stage process) with duly fixed in ground but PCC foundation (1:2:4) type B1, with danger notice plate (02 Nos) of 1.6mm thick mild steel sheet of size 20cmx15cm, vitreous enamelled (white), with letters, figures and conventional skull and bones in signal red colour, suitable for 3 phase 4 wire system 415 volts grade consisting of alaminium bus bar capacity of 400 Amps with necessary wiring with PVC sheathed stranded copper conductor of 1100 volts of appropriate length size with and including fixing lugs, bolts, screws etc complete including taking out old LT panel and comprising of the following accessories:- INCOMING :- (a) MCCB, 250 Amp, 4 Pole,36 KA - 01 No. (b) Digital Combimeter (7in1) with 4 digit LED Display -01 No (c) Indicating lamp LED type one set in incoming phase. (d) Internal wiring with PVC insulated copper conductor multi stranded cable 1100 volt grade IS 694 maked of appropriate gauge including all copper lugs. OUTGOING:- (a) MCCB, 160 Amp, 3 Pole, 36 KA - 03 No. (b) MCCB, 32 Amp, 4 Pole, 16 KA - 02 No.(c) Changover switch capacity 200 Amp 4 pole -01 No. (Notes : Make of panel, size and drawing shall be got approved from GE before placing order for procurement)
S&F in repair openwell submersible pump motor 1.5HP single phase 230 volt maintain head from 70 feet to 90 feet with all connected fitting, complete all as specified and directed
S&F in repair for analoge control panel stater with complete fitting for single phase submersible motor 1.5 HP, complete all as specified and directed.
S&F in repair self priming monoclock pump motor 1.5 HP single phase 230 volt maintain head from 70 feet to 90 feet with all connected fitting, complete all as specified and directed by Engr-in-Charge.
S&F in repair for analoge control panel stater with complete fitting for single phase monoblock motor 1.5 HP, complete all as specified and directed.
S&F in repair for self priming monoblock pump motor capacity 1 HP single phase 230 volt maintian haed from 60 feet to 90 feet with all connecting fitting, complete all as specified and directed by Engr-in-Charge.
S&F in repair for fully automatic water pressure pump of capacity 0.5HP auto cut and auto on with all fittings for connection of pump, complete all as specified and directed
S&F in repair of GI perfortage cable tray of iron and galvanised coating, side rail height 75mm with electrolytic polishing filling wall or ground, complete all as specified and directed by the Engr-in-Charge.
S&F in repair for auxiliary power contactor conforming to IEC 60947-4-1, 440 volt AC supply type AC-3 rating for current rating 160 Amp capacity, complete all as specified and directed.
All as per serial item No-133 here-in-before but capacity of 63 Amp, complete all as specified and directed.
All as per serial item No-133 here-in-before but capacity of 50 Amp, complete all as specified and directed.
All as per serial item No-133 here-in-before but capacity of 40 Amp, complete all as specified and directed.
All as per serial item No-133 here-in-before but capacity of 32 Amp, complete all as specified and directed.
S&F in repair bucket grease gun with trolley capacity 5 kg, useful for cleaning greasing of pump and machinery high pressure hand operated pump, pump has steel construction with cast head solid steel pump chamber with 2.2 m of high pressure hose fitted with accessories, complete all as specified and directed.
S&F in replacement for MCB two pole, 415 volts, 32 amps, 'C' series/curve with rupturing capacity 10 KA, including providing thimble for out going cables complete all as specified and directed.
S&F in replacement for MCB two pole, 415 volts, 63 amps, 'C' series/curve with rupturing capacity 10 KA, including providing thimble for out going cables complete all as specified and directed.
S&F in repair over load relay of three phase 440 volt AC confromance to IEC 60947-4-1, CE marking rating up to 124 to 198 Amp, complete all as specified and directed .
All as per Srl Item No. 141 here-in-before but capacity of 62 to 99 Amp.
All as per Srl Item No. 141 here-in-before but capacity of 55 to 70 Amp.
All as per Srl Item No. 141 here-in-before but capacity of 37 to 50 Amp.
S&F in repair for spreader links suitable for 440 volt MCCB 4 pole capacity of 200 Amp, complete all as specified and directed.
M/S PARSHOTAM KUMAR GUPTA (BID ID -3148990)
narayan construction (BID ID -3158086)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .