Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Accepted-Technical | Accepted-Technical Qualified. |
| 2 | Accepted-Technical | Accepted-Technical Qualified. |
| 3 | Accepted-Technical 285 N PARUI DAS PARA ROAD KOLKATA 700061 | KOLKATA | KOLKATA | WEST BENGAL | 700061 | Accepted-Technical Qualified. |
| 4 | Accepted-Technical | Accepted-Technical Qualified. |
| 5 | Accepted-Technical | Accepted-Technical Qualified. |
Tender Value
₹4.8 L
EMD Value
₹9,691
Closing Date
17 Aug 2026, 11:00 amClosed
Assistant Engineer, BNWSD-II, VYBK
The Office of The Assistnt Engineer, Bidhannagar West Sub Division-II, Public Works Directorate, Government of West Bengal, Room No. 123, 1st Floor, Purta Bhavan, DF Block, Sector - I, Salt Lake, Kolkata - 700 091.
Urgent Repair of Ladies and Gents Toilet of League Office at Competition Zone within the compound of Vivekananda Yuba Bharati Krirangan during the year 2026 2027
2026_WBPWD_5017732_2
NIeT-08/AE/BNWSD-II of 2026-2027
Open Tender
CIVIL WORKS
Percentage
15 days
SALT LAKE
Please refer Tender documents.
6 documents required · 6 mandatory
₹9,691
Yes
14 Oct 2026
31 Jul 2026
19 Aug 2026
31 Jul 2026
17 Aug 2026
31 Jul 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Dismantling all types of plain cement concrete works, stacking serviceable materials at site and
removing rubbish as directed within a lead of 75
m. In ground floor including roof.
(a) upto 150 mm. thick. | 3.92 | Cu. M. | - | - |
| 2 | Ordinary Cement concrete (mix 1:1.5:3) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement,if any, in ground floor as per relevant IS codes.
a) Pakur Variety. | 4.36 | Cu. M. | - | - |
| 3 | Supplying and laying true to line and level Double Charge Vitrified Tiles of approved brand conforming to IS 15622: 2006 (Group B I a) and tested as per IS 13630:2006 (relevant parts) [Non-modular sizes for tiles with Water Absorption (av.) ≤0.08 %] in floor, skirting etc. set in 20 mm thick sand cement mortar (1:4) bed prepared after application of slurry using 1.75Kg of cement per Sqm over the base and 2mm thick cement slurry using cement @ 2.91Kg./sqm at the back side of the tiles and laid over the mortar bed using 0.2 kg/sqm of White cement used for joint filling with approved pigment as directed and removal of wax coating of top surface of tiles with warm water and polishing the tiles using soft and dry cloth upto mirror finish complete including the cost of materials,Iabour and all other incidental charges complete true to the manufacturer's specification and direction of Engineer-in-Charge. (Note: This work should not be executed without specific permission of Superintending Engineer) (a) ln Ground FIoor:(size not Iess than 600mmX 600 mm X 9.5 mm thick). | 20.88 | Sq. M. | - | - |
| 4 | Supplying, fitting and fixing fibre reinforced polymer (FRP) Composite door frame as per approved section with glass fibre reinforced plastic moulded skins and a special sandwich core, so as to impart monolitaheic composite structure as per approved technology of Department of Science and Technology (DST) to
safisfy IS: 4020 door testing performance criteria. (i) 66mm x 90mm. | 14.55 | Mtr. | - | - |
| 5 | Supplying, fitting & fixing fibre reinforced polymer (FRP) Composite door shutters as per approved design with glass fibre reinforced plastic moulded skins and a special sandwich core, so as to impart monolitaheic composite structure as per approved technology of Department of Science and Technology (DST) to satisfy IS:4020 door testing performance criteria. In ground floor. (i) 32 mm thick. | 4.2 | Sq. M. | - | - |
| 6 | Supplying, fitting & fixing 1st quality Ceramic tiles in walls and floors to match with the existing work & 4 nos. of key stones (10mm) fixed with araldite at the back of each tile & finishing the joints with white cement mixed with colouring oxide if required to match the colour of tiles including roughening of concrete surface, if necessary or by synthetic adhesive & grout materials etc. (B) Wall. With Sand Cement Mortar (1:3) 15 mm thick & 2 mm thick cement slurry at back side of tiles using cement @ 2.91 Kg/Sq.m & joint filling using white cement slurry @ 0.20kg/Sq.m. (b) Area of each tile above 0.09 Sq.m. (i) Coloured decorative. | 19.35 | Sq. M. | - | - |
| 7 | Supplying, fitting and fixing boiling water proof ply conforming to IS: 710-1977 bonded with phenol formaldehyde synthetic resin conforming to IS: 848-1974 of approved make and brand fitted and fixed as per design as per approval and direction of Engineer-in-Charge. [excluding the cost of supporting frame work and teak wood batten/Lipping] In Ground Floor. (iv) 12 mm. | 8.92 | Sq. M. | - | - |
| 8 | Supplying fitting, fixing decorative lamination conforming to IS: 2046 : 1995 as per approved make, brand, finish and thickness with fitting, fixing the same on Particle/MDF / Ply Boards with recommended / approved adhesive with proper clipping the sides for better attachment as per direction of Engineer-incharge. The rate includes the cost of labour, adhesive and all incidental charges thereof. In ground floor. Glossy/Matt/ Suede excluding surface texture or metallic lustre. (i) Thickness of laminate 1.5mm. | 17.84 | Sq. M. | - | - |
| 9 | M.F. suspended ceiling made with 12.5 mm thick Gypsum plaster board including G.I. perimeter channel of 0.55 mm flush (having two flanges 20 mm and 30 mm respectively and web 27 mm ) along with perimeter of ceiling with G.I. intermediate channel of 0.9 mm thick size 45 mmx15mm placed at 750 mm c/c with G.I. ceiling angle of size 25 mmx10mmx0.55 mm thick fixed to the ceiling with G.I. Cleat and steel expansion fastener ceiling section 0.55 mm thick of size 51.50 mmx26mm fixed to the intermediate channels with the help of connecting clip and in the direction of perpendicular to the intermediate channel of 300 mm c/c 12.5 mm thick Gypsum plastered board are to be fixed under ceiling section as above by machine screws. The boards are to be joined and finished with jointing compound, paper tape and application of top coat etc. as per the direction of Engineer-in-charge. (The rate includes of cost of all materials including taxes,
cost of accessories, fittings and fixtures, scaffolding and labour charges etc. complete)
In ground floor. | 11.25 | Sq. M. | - | - |
| 10 | P.V.C- False Ceiling : Providing False Ceiling made with framework of steel tube of 40mm x 20mm of not less than 18 gauge,the long and cross section will be welded with each other 1000mm to 1200mm apart the entire framework will be fixed in wall using rawlplug or gutties or screws etc. and suspended from ceiling with M.S flat 19mmx3mm as necessary,the entire frame will be painted with red oxide. PRINTED LAMINATED P.V.C Section 150mm x 12mmx 1.00mm (+/- 0.01mm) of approved quality and colour will be fixed on the frame so that the entire framework will not be visible from below P.V.C Section will be fixed with the frame with the help of self tapping steel screws including all materials and labour charges including fitting,fixing the same and hoisting including mending the damages in all respect and cost of paint as required as per direction of Engineerin-Charge. In ground floor. | 48.93 | Sq. M. | - | - |
stage.html
html • 0.10 MB
tech_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.74 MB
2911.pdf
Tender Documents • 1.86 MB
BOQ_5088144.xls
BOQ • 0.30 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .