Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹9.1 CrAccepted-AOC N 65 MIDC HINGNA INDUSTRIAL AREA HINGNA NAGPUR MAHARASHTRA 440016 | NAGPUR | MAHARASHTRA | 440016 | ₹9.1 Cr Quoted ₹9.2 Cr | L-1 | Accepted-AOC L-1 Bidder. |
| 2 | L-2₹9.5 Cr+₹32.6 L (3.56%)Rejected-Finance CHALIHA NAGAR DIST TINSUKIA ASSAM | TINSUKIA | ASSAM | ₹9.5 Cr+₹32.6 L (3.56%) | L-2 | Rejected-Finance Rejected. Other than L-1. |
| 3 | L-3₹10.0 Cr+₹84.6 L (9.25%)Rejected-Finance | ₹10.0 Cr+₹84.6 L (9.25%) | L-3 | Rejected-Finance Rejected. Other than L-1. |
| 4 | L-4₹10.9 Cr+₹1.8 Cr (19.3%)Rejected-Finance | ₹10.9 Cr+₹1.8 Cr (19.3%) | L-4 | Rejected-Finance Rejected. Other than L-1. |
Tender Value
Refer Docs
EMD Value
₹8.3 L
Closing Date
4 Apr 2023, 6:00 pmClosed
CE Siliguri Zone
HQ CE Siliguri Zone, MES, Sevoke Road, PO Salugara, Jalpaiguri, 734008 (WB)
PROVN OF TECHNICAL BUILDING AT MISSAMARI UNDER GE MISSAMARI
2023_MES_581417_1
CA No. CESZ/MISM/18 OF 2021-2022 (98728/MISM/SZ)
Open Tender
Civil Works
Lump-sum
780 days
MISSAMARI
As per NIT
7 documents required · 7 mandatory
₹3,000
GE MISSAMARI
₹8.3 L
Yes
HQ CE Siliguri Zone
28 Jun 2023
16 Feb 2023
11 Apr 2023
16 Feb 2023
4 Apr 2023
21 Mar 2023
23 Feb 2023 - 2 Mar 2023
28 Feb 2023
Amount
BUILDINGS & STRUCTURE (Sch 'A' PART-I)
Lump sum price worked out by the Contractor for “BUILDINGS & STRUCTURE” as listed in Schedule ‘A’ Part-I Representing ** ___ % ______ percent *Above / Below the lump sum price of Rs. 3,90,00,000.00 inserted by the MES in Schedule ‘A’ Part-I.
PILE FOUNDATION (Sch 'A' PART-I(A))
Lump sum price worked out by the Contractor for “PILE FOUNDATION” as listed in Schedule ‘A’ Part-I(A) Representing ** ___ % ______ percent *Above / Below the lump sum price of Rs. 1,44,79,364.03 inserted by the MES in Schedule ‘A’ Part-I.
SITE CLEARANCE AND SITE DEVELOPMENT (Sch 'A' PART-II)
Lump sum price worked out by the Contractor for “SITE CLEARANCE AND SITE DEVELOPMENT” as listed in Schedule ‘A’ Part-II. Representing ** ___ % ______ percent *Above / Below the lump sum price of Rs. 25,66,306.61 inserted by the MES in Schedule ‘A’ Part-II.
INTERNAL WATER SUPPLY (Sch 'A' PART-III)
Lump sum price worked out by the Contractor for “INTERNAL WATER SUPPLY” as listed in Schedule ‘A’ Part-III. Representing ** ___ % ______ percent *Above / Below the lump sum price of Rs. 19,991.98 inserted by the MES in Schedule ‘A’ Part-III.
INTERNAL ELECTRIFICATION (Sch 'A' PART-IV)
Lump sum price worked out by the Contractor for “(INTERNAL ELECTRIFICATION)” as listed in Schedule ‘A’ Part-IV. Representing ** ___ % ______ percent *Above / Below the lump sum price of Rs. 3,47,141.05 inserted by the MES in Schedule ‘A’ Part-IV.
EXTERNAL WATER SUPPLY (Sch 'A' Part-V)
Lump sum price worked out by the Contractor for “(EXTERNAL WATER SUPPLY)” as listed in Schedule ‘A’ Part-V. Representing ** ___ % ______ percent *Above / Below the lump sum price of Rs. 9,714.5 inserted by the MES in Schedule ‘A’ Part-V.
EXTERNAL ELECTRIFICATION (Sch 'A' PART-VI)
Lump sum price worked out by the Contractor for “(EXTERNAL ELECTRIFICATION)” as listed in Schedule ‘A’ Part-VI. Representing ** ___ % ______ percent *Above / Below the lump sum price of Rs. 5,65,794.79 inserted by the MES in Schedule ‘A’ Part-VI.
ROAD, PATH & CULVERT (Sch 'A' Part-VII)
Lump sum price worked out by the Contractor for “(ROAD, PATH & CULVERT)” as listed in Schedule ‘A’ Part-VII. Representing ** ___ % ______ percent *Above / Below the lump sum price of Rs. 39,40,560.79 inserted by the MES in Schedule ‘A’ Part-VII.
PCC HARDSTANDING (Sch 'A' Part-VIII)
Lump sum price worked out by the Contractor for “(PCC HARDSTANDING)” as listed in Schedule ‘A’ Part-VIII. Representing ** ___ % ______ percent *Above / Below the lump sum price of Rs. 27,15,605.96 inserted by the MES in Schedule ‘A’ Part-VIII.
DUNNAGE BLOCK (Sch 'A' PART-IX)
Lump sum price worked out by the Contractor for “(DUNNAGE BLOCK)” as listed in Schedule ‘A’ Part-IX. Representing ** ___ % ______ percent *Above / Below the lump sum price of Rs. 1,30,737.6 inserted by the MES in Schedule ‘A’ Part-IX.
FIRE FIGHTING POINT (Sch 'A' Part-X)
Lump sum price worked out by the Contractor for “(FIRE FIGHTING POINT)” as listed in Schedule ‘A’ Part-X. Representing ** ___ % ______ percent *Above / Below the lump sum price of Rs.18,274.04 inserted by the MES in Schedule ‘A’ Part-X.
RCC RETAINING WALL (Sch 'A' Part-XI)
Lump sum price worked out by the Contractor for “(RCC RETAINING WALL)” as listed in Schedule ‘A’ Part-XI. Representing ** ___ % ______ percent *Above / Below the lump sum price of Rs. 74,67,067.16 inserted by the MES in Schedule ‘A’ Part-XI.
BRICK MASONRY RETAINING WALL (Sch 'A' Part-XII)
Lump sum price worked out by the Contractor for “(BRICK MASONRY RETAINING WALL)” as listed in Schedule ‘A’ Part-XII. Representing ** ___ % ______ percent *Above / Below the lump sum price of Rs. 56,77,070.64 inserted by the MES in Schedule ‘A’ Part-XII.
FIRE ALARM SYSTEM (Sch 'A' Part-XIII)
Lump sum price worked out by the Contractor for “(FIRE ALARM SYSTEM)” as listed in Schedule ‘A’ Part-XIII. Representing ** ___ % ______ percent *Above / Below the lump sum price of Rs. 2,47,036.00 inserted by the MES in Schedule ‘A’ Part-XIII.
FIRE FIGHTING SYSTEM (Sch 'A' Part-XIV)
Lump sum price worked out by the Contractor for “(FIRE FIGHTING SYSTEM)” as listed in Schedule ‘A’ Part-XIV. Representing ** ___ % ______ percent *Above / Below the lump sum price of Rs. 19,48,005.00 inserted by the MES in Schedule ‘A’ Part-XIV.
LIGHTNING PROTECTION (Sch 'A' Part-XV)
Lump sum price worked out by the Contractor for “(LIGHTNING PROTECTION)” as listed in Schedule ‘A’ Part-XV. Representing ** ___ % ______ percent *Above / Below the lump sum price of Rs. 11,84,558.5 inserted by the MES in Schedule ‘A’ Part-XV.
MISCELLANEOUS ITEMS REQUIRED FOR B/R & E/M SERVICES (Sch 'A' Part-XVI)
SITE CLEARANCE AND SITE DEVELOPMENT Bringing approved earth (as approved by GE) from a distance of 5 km, outside defence land including all cost such as royalty, if any, transportation complete all as specified and directed.
INTERNAL ELECTRIFICATION S&F Explosion proof for Zone 1 & 2 Gas Groups IIA, IIB & IIC (FLP-WP) MCB DB distribution board 4 way complete all as specified and directed.
S&F Explosion proof for Zone 1 & 2 Gas Groups IIA, IIB & IIC (FLP-WP) MCB DB distribution board 12 way complete all as specified and directed.
S & F of MCB Double Pole 20 Amps 240/415 Volt, confirms to IS/IEC 60898 Braeking Capacity of 10 kA, C-curve, complete all as specified and directed.
S & F of MCB Double Pole 10 Amps 240/415 Volt, confirms to IS/IEC 60898 Braeking Capacity of 10 kA, C-curve, complete all as specified and directed.
S & F of MCB SP, 240 volts, 6A Amps 50 Hz ,confirms to IS/IEC 60898 Braeking Capacity of 10 kA, C-curve, complete all as specified and directed.
S&F of LED light fitting 1 x 24 W, 6500 K, 230 V, wall mounted Decorative ultra slim round profie LED lighting fixture with extruded polycarbonate diffuser, environmental friendly, energy efficient LED batten with integrated electronic driver, fixed on and including 02 Nos. of PVC round / square block, screws,etc complete with all accessories internally prewired and including connecting up with and including twin core twisted flexible copper conductor cable with suitable size complete all as specified and as directed. Make : E-Lite LED Pride Plus nxt Cat No. LHEXACP7IN1S024 Havells or equivalent make as specified in PS.
S & F of Energy saving new generation environmental friendly long life versatile presure die cast aluminium IP 66 security light fitting luminaire with high power LEDs as light source and PC Cover having TOP opening seperate driver compartment with IP 66 Protection and impact resistance of IK07 with electronic driver of capacity 25 watts with pre wired and necessary mounting arrangements, provision of new 3 core multistranded copper conductor of size 23/0.193 from ceiling rose to fitting and GI pipe bracket made out of GI pipe medium grade 32 mm dia 1.5 mtr long bend to required shape complete all as specified and as directed. MAKE : Havells, Model No - ENDURAPEARLSL25WLED757SASYTOPCMP Or Equivalent make as specified in PS.
M&L for earthing complete with galvanised steel earth plate electrode size 600x600x6.0mm thick buried directly in ground vertically in a pit of depth not less than 2.25 mtr below ground levels with top edge of the earth plate not less than 1.5 mtr below normal ground level surrounded from all sides by mixture of charcoal and common salt and electrode connected to and including galvanised earth lead wire 4.0 mm dia means of bolts, nuts, check nuts and washers of galvanised steel and GI pipe light grade 20mm dia bore for watering funnel with wire mesh refilling with vegetable soil without bolders and stones, gravels and aggregate etc,and CI cover with frame, PCC chamber pit with PCC 1:3:6 type C-2 excavation and earth work all as shown in electrical plate No 5 connected to earthing test point all as specified or indicated including testing on completion. NOTE : The unit rate includes for protection pipe and GI strip dia from top of earth plate up to 5.00 meter above ground level.
EXTERNAL WATER SUPPLY Supply, laying, jointing & testing of Ductile Iron (DI) Pressure 80 mm bore (dia) with Spigot & Socket Ends, Centrifugally Cast (Spun) with Cement Mortar Lining in Inner Side confirming to IS : 8392 /2000 in standard length for classification K-7 and other relevant standards and Metallic Zinc Coating followed by a finishing layer of Epoxy Paint in outer side, suitable for Push-on Joint (Rubber Gasket Joint) in any length and laid in Trenches, complete all as specified and as directed. NOTE :- (a) Excavation, DI Specials shall be measured and paid separately. (b) Rate of rubber gasket joint shall be included in quoted rate.
S&F of DI Bends tapers, Tees, pieces (Single or double branch) any Type and angle/ radius and straight connecting pieces for Pipe upto 300mm bore complete all as specified and as directed.
EXTERNAL ELECTRIFICATION M&L for Boring holes horizontally under Road without damaging the surface of Road of any type (minimum 1.0 METRE below the Road Surface with the help of GI Tubing not exceeding 40mm bore for passing of UG Cable, complete all as specified and as directed. NOTE: GI Pipe laid will be measured and paid separately under appropriate Item.
Supply, install, test and commission step down transformer, outdoor type, plinth mounted HT 11 KV, 3 phase 433 volts, 4 wire, 50 Hz, delta/star connected, vector group DYN -11 double copper wound, ONAN, manual type off load tap changing facility on HT side to vary secondary voltage from minus 7.5% to plus 7.5% in steps of 2.5 %, continuous rating, Level-02 of capacity 100 KVA incl bushing on HT end cable box on LT side. The transformer shall be complete with all standard fittings and accessories, gauges, first fill of transformer oil, etc, and conforming to IS 1180 Part-1:2014 duly mounted on plinth and all as specified and as directed. (a) Oil conservator with filling hole, cap and drain plug (b) Silica gel breather with oil seal and first fills of dehydrating agent (c) Adequate Nos of thermometer pockets incl one No for accomodating bulb type thermometer (d) Drain cum bottom filter valve (e) Top filter valve (f) Prisomatic oil level gauge (g) Inspection cover (h) Cover fitting lugs (j) Jacking and fitting lugs (k) Separate neutral bushing brought out for earthing on LV side (l) Earthing terminal Note :- (a) Cost of platform will be included in the quoted rate.
FIRE ALARM SYSTEM Supply, laying testing and commissioning of XLPE insulated, heavy duty electric cable of size 2 x 2.5 Sqmm with copper conductor armoured with working voltage upto & incl 1100 Volts conforming to IS:7098 Part-I to be laid in trenches/ pipes/roof/ walls/ceiling etc twested , FRLS fire survival cable wrapped in 950 Mica tape for connecting Fire Alarm System including necessary fixing arrangement complete all as specified and as directed.
All as per Item No 16.15 above but unarmoured single core 2.5 sqmm unarmoured with PVC insulation , conforming to IS 1554 Part-I , drawn through ISI marked ERW steel conduit with conduit accessories complete all as specified. NOTE : Steel Conduit with conduit accessories shall be measured and paid separately.
S&F of UPS for 30 min backup Single phase AC input 160 to 240 V and output 230 V of capacity 2 KVA complete all as specified and directed.
S&F of Fault Isolator Module I-300A complete all as specified and directed. MAKE : Honeywell Automation or equivalent make as approved by GE.
FIRE FIGHTING SYSTEM Supply, laying, jointing & testing of Ductile Iron (DI) Pressure pipe 80 mm bore (dia) with flanged ends from both side, Centrifugally Cast (Spun) with Cement Mortar Lining in Inner Side confirming to IS : 8392 /2000 in standard length for classification K-9 and other relevant standards and Metallic Zinc Coating followed by a finishing layer of Epoxy Paint in outer side, suitable for Push-on Joint (Rubber Gasket Joint) in any length and laid in Trenches, complete all as specified and as directed. NOTE : (a) Excavation, DI Specials shall be measured and paid separately. (b) Rate of rubber gasket, nuts and bolts and washer shall be included in quoted rate.
Supply, laying, jointing & testing of Ductile Iron (DI) Pressure pipe 150 mm bore (dia) with flanged ends from both side, Centrifugally Cast (Spun) with Cement Mortar Lining in Inner Side confirming to IS : 8392 /2000 in standard length for classification K-9 and other relevant standards and Metallic Zinc Coating followed by a finishing layer of Epoxy Paint in outer side, suitable for Push-on Joint (Rubber Gasket Joint) in any length and laid in Trenches, complete all as specified and as directed. NOTE :- (a) Excavation, DI Specials shall be measured and paid separately. (b) Rate of rubber gasket, nuts and bolts and washer shall be included in quoted rate.
Supply, laying, jointing & testing of Ductile Iron (DI) Pressure pipe 200 mm bore (dia) with flanged ends from both side, Centrifugally Cast (Spun) with Cement Mortar Lining in Inner Side confirming to IS : 8392 /2000 in standard length for classification K-9 and other relevant standards and Metallic Zinc Coating followed by a finishing layer of Epoxy Paint in outer side, suitable for Push-on Joint (Rubber Gasket Joint) in any length and laid in Trenches, complete all as specified and as directed. NOTE :- (a) Excavation, DI Specials shall be measured and paid separately. (b) Rate of rubber gasket, nuts and bolts and washer shall be included in quoted rate.
S&F of Cast iron Air release Valves with two air outlets, 150mm dia bore and fixing up in cast iron supply mains complete all as specified and as directed.
Supply, installing, testing and commissioning indoor cubical type LT control panel made out of 2 mm thick CRCA sheet with top canopy with locking arrangements of suitable size, pedestal mounted, CPRI approved factory made totally enclosed, with suitable neoprene rubber gasket to make it completely dust and vermin proof & degree of protection not less than IP -43/42 and general construction conforming to IS -13947 front and back openable, double leaf shutter in front and single leaf shutter in rear side , having proper locking arrangement in both front and rear door and painted with powder coating paint and suitable for 415 volts, 50 Hz, 3 phase 4 wire system and comprising with and including following accessories and mounted on PCC Plat form all around the panel board complete all as specified and directed with the following items housed :- (a) 400 Amps rated copper bus bar TPN duly insulated with coloured PVC sleeve as per standard colour code (b) Incommer MCCB 4 Pole 200 Amps, thermal magnetic type DN2-250D with breaking capacity 36 KA with thermal magnetic release at 415 volts,including spreader terminal, make: L&T Cat part No. CM92109OOP1OG or equivalent as approved by GE. -01 No (c) Outgoing MCCB TP 160 Amps, thermal magnetic type DN2-250D with breaking capacity 36 KA with thermal magnetic release at 415 volts, including spreader terminal,for main fire Pump. make: L&T Cat part No. CM92009OOM1OG or equivalent as approved by GE. (01 No + 01 spare) Item continued as 16.24
Supplying, laying, termination & testing of copper conductor of size 3Core x 35 sq.mm, XLPE insulated unarmoured both inner and outer sheath, PVC sheathed and sleeved 1.1 KV grade power distribution cables conforming to relevant IS code and laying through and clamping the wall or laid in ducts including dressing and clamping the cable with M.S. zinc passivated clamps etc. as required complete all as specified and as directed.
Supplying, laying, termination & testing of copper conductor of size 3Core x 16 sq.mm XLPE insulated unarmoured both inner and outer sheath, PVC sheathed and sleeved 1.1 KV grade power distribution cables conforming to relevant IS code and laying through and clamping the wall or laid in ducts including dressing and clamping the cable with M.S. zinc passivated clamps etc. as required complete all as specified and as directed.
S&F of Foot Valve of size 150 mm conforming to IS 4038 complete all as specified and as directed.
M&L Construction Brick Masonry Valve Pit of size 900x900x900 mm (Internal Dimension) one Brick thick Wall in Cement Mortar 1:4 on 100mm thick PCC 1:4:8 (40mm graded aggre-gate) in Foundation, Rendering 15mm thick internally and externally upto 150mm below GL, providing 3.0mm thick MS Sheet Valve Pit Cover, welded with 40x5mm Flat Iron Frame alround including provision of Hinges, Handle with Locking Arrangement and 40x40 x6mm Angle Iron Frame fixed on top of Valve Pit by means of holdfast 150mm long, embedd -ed in PCC 1:2:4 (20mm graded aggregate) Block of size 230x200x100 mm, applying two coats of Anti-corrosive Paint to all exposed Steel Surfaces over a coat of red oxide zinc chrome Primer after preparation of Surfaces and necessary Earth Work in Soft/ Loose Soil including demolition of unserviceable Valve Pit, complete all as specified and as directed.
M&L for earthing complete with galvanised steel earth plate electrode size 600x600x6.0mm thick buried directly in ground vertically in a pit of depth not less than 2.25 mtr below ground levels with top edge of the earth plate not less than 1.5 mtr below normal ground level surrounded from all sides by mixture of charcoal and common salt and electrode connected to and including galvanised Iron strip of size 32 x 6 mm by means of bolts, nuts, check nuts and washers of galvanised steel and GI Protection pipe light grade 40 mm dia bore for watering funnel with wire mesh refilling with vegetable soil without bolders and stones, gravels and aggregate etc,and CI cover with frame, PCC chamber pit with PCC 1:3:6 type C-2 excavation and earth work all as shown in electrical plate No 5 connected to earthing test point all as specified or indicated including testing on completion all as specified and as directed. NOTE : The unit rate includes for protection pipe and GI strip dia from top of earth plate up to 5.00 meter above ground level.
FIRE SYMBOL BOARD S & F for fire reflective sign board of size 1800mmx1200mm with writing (as required) on board made by 4 mm thick aluminium composite panel sheet finished of size required with high intensity reflecting type on both side duly framed on 60mm dia and 25 mm dia stainless steel pipe of 304 grade, post of height 2.60 m from GL fitted with 16 gauge steel duly fitted with round on top and fixed post with PCC 1:2:4 in ground upto 60 cm depth and necessary earth work incl. returning filling and removal of surplus soil and make good as directed complete all as specified and as directed.
LIGHTNING PROTECTION S&F of Porcelain insulator of suitable size for proper securing to roof conductor of aluminium strip including dismantaling of unserviceable insulator complete all as specified and as directed.
PILE FOUNDATION Initial test of pile foundation complete all as specified and as directed.
Test of working pile complete all as specified and as directed.
Integrity test of pile complete all as specified and as directed.
Sub total
VIJAY AGARWAL & SONS
Jasvit Constructions Private Limited
M/s AGAM CONSTRUCTION
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .